DC24V 온-오프 타입 액추에이터(전동 밸브)의 작동 원리

When you install a DCL 24V ON-OFF type electric control valve on a pipeline, you can control it using a relay, ON-OFF control, or PLC (DCS), enabling the opening or shutting off of fluid flow. This guide explains how the DCL 24V ON-OFF type electric actuators function using relays, PLCs, or ON-OFF control for valve […]

AC220V 온-오프 타입 액추에이터(전동 밸브)의 작동 원리

When you install a DCL AC220V ON-OFF type electric control valve on a pipeline, you can control it using a relay, ON-OFF control, or PLC (DCS), enabling the opening or shutting off of fluid flow. This guide explains how the DCL AC220V ON-OFF type electric actuators function using relays, PLCs, or ON-OFF control for valve […]

기술 문의

service@dcl-controls.com Phone (+86) 130 2633 1611 WhatsApp Ken Bryan In site chat Click on the icon at the bottom right corner to chat with us…

액추에이터의 입력 신호를 보정하는 방법은 무엇인가요?

액추에이터의 입력 신호를 보정하는 방법은 무엇인가요?

When the actuator’s valve position does not match the 4–20mA input signal (resulting in a discrepancy between the feedback signal and the input signal), you can calibrate the input signal to eliminate this deviation. 6 Simple Steps for Calibration: Turn the S-A switch to position 2. Press and hold the Set button until the L2 […]

IoT를 사용하여 간헐적인 액추에이터 오류 모니터링 및 분석하기

Customer Feedback: The Three-Way Valve in the Cooling System Failed to Reach the Designated Position A nuclear power customer reported an intermittent failure of the actuator. Specifically, after the control system issued an opening command via a 4-20mA signal, the actuator’s feedback position remained unchanged. Upon cutting off the power and inspecting the site, the […]

Common faults & troubleshooting for DC24V Modulating Actuators

This guide is applicable to the DCL Explosion-proof Series / Weather-proof Series / Quick-Turning Series of modulating actuators powered by DC24V, with the following models: Weather-proof Actuator: DCL-02GEY, DCL-05GEY, DCL-10GEY, DCL-20GEY, DCL-40GEY, DCL-60GEY Explosion-proof Actuator: DCL-Ex05GEY, DCL-Ex10GEY, DCL-Ex20GEY, DCL-Ex40GEY, DCL-Ex60GEY Let me know if you need further assistance with this guide! Open the Electric Chamber […]

Common faults & troubleshooting for DCL-02 ON-OFF actuators

This guide is applicable to the DCL Ultra-Small Series actuators, with the following models: DCL-02A DCL-02B DCL-02G Common Faults and Troubleshooting Methods   Fault Possible Causes Troubleshooting Methods Actuator does not open or close on initial start 1. Incorrect wiring Check the wiring according to the actuator’s wiring diagram.   2. Incorrect power supply Ensure […]

Common faults & troubleshooting for DCL-02 modulating actuators

This guide applies to the DCL ultra small modulating actuators, model as follows: DCL-02E Common Faults and Troubleshooting Methods   Fault Possible Cause Troubleshooting Method Actuator will not open or close at startup 1. Incorrect wiring Check the wiring according to the actuator wiring diagram to confirm it is correct.   2. Incorrect power supply […]

Common faults & troubleshooting for Modulating Actuators

This guide applies to the modulating actuators of the DCL explosion-proof series, weather-proof series, and quick-turn series. The models are as follows: Weather-proof actuator: DCL-05, DCL-10, DCL-20, DCL-40, DCL-60, DCL-100, DCL-160, DCL-250Explosion-proof actuator: DCL-Ex05, DCL-Ex10, DCL-Ex20, DCL-Ex40, DCL-Ex60Quick-turn actuator: DCL-K05, DCL-K10, DCL-K20, DCL-K40, DCL-K100 Common Faults and Fault Exclusion Methods   Fault Possible Causes Fault […]

Common faults & troubleshooting for ON-OFF actuators

Common faults & troubleshooting for ON-OFF actuators

This guide applies to the switch-type actuators of the DCL explosion-proof series, standard series, and quick-open series. The models are as follows: Weather-proof Actuator: DCL-05, DCL-10, DCL-20, DCL-40, DCL-60, DCL-100, DCL-160, DCL-250Explosion-Proof Actuator: DCL-Ex05, DCL-Ex10, DCL-Ex20, DCL-Ex40, DCL-Ex60Quick-Turn Actuator: DCL-K05, DCL-K10, DCL-K20, DCL-K40, DCL-K100 Common Faults and Troubleshooting Methods   Fault Possible Causes Troubleshooting Methods […]

견적 요청

지금 '보내기'를 누르시면 나중에 제품 모델 번호와 현지 유통업체를 확인한 후 견적을 보내드리겠습니다.

WhatsApp

지금 QR을 스캔하여 엔지니어와 채팅하세요...

견적 요청

지금 '보내기'를 누르시면 나중에 제품 모델 번호와 현지 유통업체를 확인한 후 견적을 보내드리겠습니다.

WhatsApp

지금 QR을 스캔하여 엔지니어와 채팅하세요...

견적 요청

지금 '보내기'를 누르시면 나중에 제품 모델 번호와 현지 유통업체를 확인한 후 견적을 보내드리겠습니다.

WhatsApp

지금 QR을 스캔하여 엔지니어와 채팅하세요...

🤝 Let’s Build Your Brand Together

✅ ODM

  • Your logo & packaging
  • Custom output formats (4-20mA, RS485 Modbus, HART, etc.)
  • Housing color or label changes
  • Cloud-ready versions (optional)

✅ OEM

  • Strictly follow your design & specifications
  • Full confidentiality & IP protection
  • High-quality production at competitive cost
  • Small-batch or large-scale production
  • 🏭 In-House R&D & Manufacturing: From PCB to enclosure, all under one roof.
  • 💬 Multilingual Support: English-speaking engineers and sales staff.

  • ⚙️ Flexible MOQ: Support for both startups and global brands.

  • 🚀 Fast Prototyping: Sample delivery in 7–10 days.

 Contact us today to request a product catalog or get a free consultation.

견적 요청

문의 보내기

WhatsApp

지금 QR을 스캔하여 엔지니어와 채팅하세요...

문의하기

전화

(+86) 130 2633 1611

WhatsApp

켄 브라이언

실시간 고객 서비스 아이콘 | 실시간 메시지 아이콘

사이트 채팅에서

오른쪽 하단에 있는 아이콘을 클릭하여 채팅하세요...