Common faults & troubleshooting for DCL-02 ON-OFF actuators
This guide is applicable to the DCL Ultra-Small Series actuators, with the following models: DCL-02A DCL-02B DCL-02G Common Faults and Troubleshooting Methods Fault Possible Causes Troubleshooting Methods Actuator does not open or close on initial start 1. Incorrect wiring Check the wiring according to the actuator’s wiring diagram. 2. Incorrect power supply Ensure […]
Common faults & troubleshooting for DCL-02 modulating actuators
This guide applies to the DCL ultra small modulating actuators, model as follows: DCL-02E Common Faults and Troubleshooting Methods Fault Possible Cause Troubleshooting Method Actuator will not open or close at startup 1. Incorrect wiring Check the wiring according to the actuator wiring diagram to confirm it is correct. 2. Incorrect power supply […]
Common faults & troubleshooting for Modulating Actuators
This guide applies to the modulating actuators of the DCL explosion-proof series, weather-proof series, and quick-turn series. The models are as follows: Weather-proof actuator: DCL-05, DCL-10, DCL-20, DCL-40, DCL-60, DCL-100, DCL-160, DCL-250Explosion-proof actuator: DCL-Ex05, DCL-Ex10, DCL-Ex20, DCL-Ex40, DCL-Ex60Quick-turn actuator: DCL-K05, DCL-K10, DCL-K20, DCL-K40, DCL-K100 Common Faults and Fault Exclusion Methods Fault Possible Causes Fault […]
Common faults & troubleshooting for ON-OFF actuators

This guide applies to the switch-type actuators of the DCL explosion-proof series, standard series, and quick-open series. The models are as follows: Weather-proof Actuator: DCL-05, DCL-10, DCL-20, DCL-40, DCL-60, DCL-100, DCL-160, DCL-250Explosion-Proof Actuator: DCL-Ex05, DCL-Ex10, DCL-Ex20, DCL-Ex40, DCL-Ex60Quick-Turn Actuator: DCL-K05, DCL-K10, DCL-K20, DCL-K40, DCL-K100 Common Faults and Troubleshooting Methods Fault Possible Causes Troubleshooting Methods […]
DCL 액추에이터 모드버스 애플리케이션 노트

DCL actuators support the Modbus-RTU protocol. Referring to this application manual, you can connect DCL actuators to Modbus. Panel SF-LC/MB SF-ZC/MB 1. Interface Definition P1:220VAC NP2:220VAC LP3:4-20mA Input –P4:4-20mA Input+P5:4-20mA Output-P6:4-20mA Output+P7:RS485 AP8:RS485 B 2. Button Open: Used in setting mode. Press this button to open the actuator while release it to stop. Press Set […]
10년간 무결점으로 작동하는 DCL-250 액추에이터

Customer Reached Out to Us Again A customer contacted us to place a new order for electric actuators. However, the nameplates on the previously installed actuators had been corroded, making it impossible to identify the product model. The customer sent site photos for model confirmation. 13 Years of Reliable Operation with DCL-250 Actuators After analyzing […]
Types of Actuators and How to Choose the Right One
Actuators can be classified based on their driving method into the following categories: 1. Electric Actuators Electric actuators use an electric motor as the power source, converting electrical energy into mechanical motion to drive the valve. Advantages: ✔ Adjustable speed✔ High positioning accuracy✔ Large torque output Disadvantages: ✖ Thermal effects of the motor may trigger […]
How Humidity Reduces the Lifespan of Actuators (Electric Valves)?
Humidity is well known to cause damage to electronic components. One of the primary ways humidity reduces the lifespan of electric actuators is through ionic migration short circuits. 1. What is Ionic Migration Short Circuit? Ionic migration occurs when moisture and contaminants on a circuit board facilitate the movement of ions between conductors, leading to […]
What Does the S2 Duty Cycle Mean in Actuators (Electric Valves)?
Many people have questions about the S2 duty cycle in actuators or electric valves. What does it mean, and why is it defined this way? 1. The Origin of S1, S2, S3, and S6 Duty Cycles The S1, S2, S3, and S6 duty cycles originate from electric motor classifications, with a primary focus on thermal […]
Can DCL Actuators Be Used in High-Altitude Areas?
High-altitude environments present unique challenges that can impact the performance of DCL electric actuators. This report evaluates their usage at 3,000 meters above sea level. 1. How High Altitude Affects Electrical Products As altitude increases:✔ Air density and pressure decrease, leading to lower insulation strength and increased risk of electrical breakdown.✔ Cooling efficiency decreases, causing […]