DCLアクチュエータを使い始めるための5つのステップ
1. Install actuator onto the valve Turn the valve in fully closed position. Install the bracket on the valve. Connect the coupling on the valve shaft. Drive the actuator to the fully closed position with manual handle. Insert the actuator output shaft into the square hole of the coupling. Tighten the connecting between these parts. Drive the actuator with manual handle to in the travel range, checking if turning smooth. Attention: make sure the concentricity of connection shaft in the mounting process and do not use excessive force. More Details > 2. Check mechanical limiter The mechanical limiter has been set in the right position after manufacturing. Normally we […]
vaTestTool_DCL.exeによるDCLアクチュエータのModbus制御方法

1.Open vaTestTool_DCL-v1.31.exe. 2.The application will popup a “Connect to” dialog to set the target device id and local computer RS232 port parameters as follow. Choose the COM port which connected to the USB-RS485 connector. Select the modbus baud rate (the default baudrate on DCL actuator now is 9600). Click on “CONNECT”button to connect to the actuator. 3.Close the “Connect to” windows and now you are in operation windows. Now you can click on “OPEN/CLOSE/STOP”button to control the actuator. Your can input in “Set position”text frame and then click on “SET POS” button to let actuator drive the valve to the position as you wish. You can click on “4-20mA INPUT”to let […]
JB/T 8219-2016 工業用プロセス制御システムに使用される普通およびインテリジェント電気アクチュエータの規格
Table of Contents Preface 1 Scope 2 Normative References 3 Terms and Definitions 4 Product Classification and Basic Parameters 4.1 Product Classification 4.2 Basic Parameters 5 Basic Functions of Intelligent Actuators 5.1 Display Function 5.2 Parameter Setting Function 5.3 On-Site Configuration Function 5.4 Fault Self-Diagnosis and Alarm Function 5.5 Communication Function 5.6 Other Functions 6 Requirements 6.1 Basic Performance Requirements 6.2 Performance Requirements Affected by Influencing Factors 6.3 Appearance 6.4 Protection Level of the Enclosure 6.5 Explosion-Proof Performance 7 Test Methods 7.1 Test Conditions 7.2 General Test Provisions 7.3 Basic Error 7.4 Basic Deviation of Position Output Signal 7.5 Hysteresis 7.6 Dead Zone 7.7 Time Delay 7.8 Rated Stroke Time […]
電動アクチュエータ用の一般的な中古バス
より多くのセンサーやアクチュエーターを制御するために、フィールドバスを導入する産業用制御システムが増加している。流体制御プロセスにおける重要なアクチュエータとして、電動アクチュエータは産業用アプリケーションで一般的に使用されています。電動アクチュエータに最も頻繁に使用されるバスシステムには、Modbus、CAN、Profibus、DeviceNet、Foundation Fieldbus、HART、Ethernetがあります。電動アクチュエータ用の一般的なバスシステムModbus CAN Profibus DeviceNet Foundation Fieldbus (FF) HART Ethernet Modbus 他のフィールドバス技術と比較して、Modbusはシンプルですが多機能です。単純なバイナリ情報、アナログ値、デバイスパラメータ、診断データの交換など、ファクトリーオートメーションに必要なすべてのサービスを提供します。ファクトリーオートメーションやProfibusのようなデバイスには、シンプルな[...]が必要です。
EN15714-2 電動アクチュエータ制御(デューティ)の分類
Control Duty Classifications: Class A: ON-OFF Type (On/Off) Function: The actuator is required to drive the valve through its entire stroke from fully open to fully closed (and vice versa). Typical Use: Applications where valves are either fully open or fully closed. Class B: Fine-Tuning/Positioning Adjustment Type Function: The actuator occasionally moves the valve to any position (fully open, intermediate, or fully closed). Typical Use: Applications requiring occasional adjustment but not continuous movement. Class C: Modulating Type Function: The actuator frequently moves the valve between fully open and fully closed positions. Typical Use: Applications that require continuous and frequent modulation of valve position. Class D: Continuous Modulating Type Function: The […]
プロセス制御アクチュエータはいつ選ぶべきか?
プロセス制御用アクチュエータの応用背景 多くのプロセス制御システムでは、自動制御システム(PLC/DCS)を通して液体や気体の流量を高精度で一貫して制御する必要があります。高い精度が要求されるため、このようなシステムでは、閉ループ制御を実施する際に、制御弁を連続的かつ正確に微調整する必要が生じることがよくあります。このような場合、制御バルブはプロセス制御システムの中核となります。可変流量システムでは、液体や気体の流量は、流量、圧力、温度などの変数に基づいて調整されます。コントロールバルブ用のアクチュエータを構成する場合、プロセスコントロール用アクチュエータを選択する必要があります。これらのアクチュエータは [...]...
電動アクチュエータの電磁干渉試験(EFT)
産業現場における過酷さを増す電磁環境 産業の電化と知能化が進むにつれ、産業プロセス制御システムに統合される大電力電気機器(キロワットレベルのモーター、周波数変換器、インバーターなど)の数が増えています。その結果、産業現場の電磁環境はより複雑になっています。このような厳しい電磁環境において、電動アクチュエータの干渉防止性能を向上させ、信頼性の高い安定した動作を確保するにはどうすればよいのでしょうか。実際のアプリケーションにおける電子制御装置やセンサーの信頼性を確保するために、IECは産業現場で最も一般的で結合しやすい電気干渉パルスを研究し、分類しました。彼らは、周波数、[...]などの典型的な波形特性を定義した。
電動バルブのデジタル化とネットワーク化の発展動向
RotorkRotork talks about digitalization of electric valves Rotork talks about the digitalization of electric valvesRotork recently discussed the importance of digitalization to valve automation and control in the European Control Engineering magazine. Industrial Internet of Things (IIoT) technology uses electronic devices such as sensors to collect and share data, and uses the computing power of cloud platforms to deeply mine and utilize data. This technology has spawned the gradual development of industrial process control towards networking and intelligence. Modern technological innovation is no longer limited to the innovation of product functions; it is about how to save and utilize the data generated in the product application process to achieve faster […]
一般的なバルブの種類とその特徴
バタフライバルブの動作原理:バタフライバルブは、ディスクを使用して流体または気体の流れを制御します。ディスクはシャフトに取付けられ、ハンドルが回されるとき、ディスクは流れを許可するか、または妨げるために 90 度回ります。特徴シンプルな構造、コンパクトなサイズ、低い流体抵抗、一般的に大流量と低圧のアプリケーションで使用されます。ボールバルブの動作原理:ボールバルブは、中空で穴の開いた、回転可能な球状のバルブエレメントを使用して、流体または気体の流れを制御します。ハンドルを回すと、ボールが90度回転して流れを制御します。特徴高信頼性、低メンテナンス、高圧・高温用途に適し、[...]広く使用されている。
エンクロージャ保護定格(UL、CSA、NEMA)

UL、CSA、NEMAが定めるエンクロージャの保護等級は以下のように分類されています。これらの分類は一般的に類似していますが、細部には細かな違いがあるため、より正確な情報については各規格を参照することをお勧めします。タイプ 分類 定義 1 一般 屋内用で、異常な使用環境を伴わない通常の条件下で、密閉された部品を保護する。2 防滴 屋内用で、落下する水やほこりの量が制限された環境での保護。3 防雨、防塵、防みぞれ(氷) 屋外用で、風による粉塵、雨、みぞれから保護します。3S 防雨、防塵、防みぞれ。