Compare parameters between DCL explosion-proof actuators
| Model | Ángulo de oscilación | Par/Tiempo de funcionamiento | Duty Type | Tensión de alimentación | Señal de entrada/salida | Additional Option |
|---|---|---|---|---|---|---|
| DCL-Ex05 | 0 - 360 ° | 50 Nm/20 S Optional with 20Nm/4S 30Nm/10S 50Nm/60S | ON - OFF Modulación Avance lento - Posicionamiento | 24 V CC 24 V CA CA 110V CA 220V CA 380V | 4-20 mA 0-10V Interfaz de E/S Optional with field bus Modbus-RTU Modbus-ASCII CAN Ethernet | Over torque protection Fail Safe Return Deshumidificación Autobús de campo |
| DCL-Ex10 | 0 - 90 ° | 100 Nm/30 s Optional with 50Nm/15S 100Nm/60S | ON - OFF Modulación Avance lento - Posicionamiento | 24 V CC 24 V CA CA 110V CA 220V CA 380V | 4-20 mA 0-10V Interfaz de E/S Optional with field bus Modbus-RTU Modbus-ASCII CAN Ethernet | Over torque protection Fail Safe Return Deshumidificación Autobús de campo |
| DCL-Ex20 | 0 - 90 ° | 200 Nm/30 s Optional with 100Nm/15S 200Nm/60S | ON - OFF Modulación Avance lento - Posicionamiento | 24 V CC CA 110V CA 220V CA 380V | 4-20 mA 0-10V Interfaz de E/S Optional with field bus Modbus-RTU Modbus-ASCII CAN Ethernet | Over torque protection Fail Safe Return Deshumidificación Autobús de campo |
| DCL-Ex40 | 0 - 90 ° | 400 Nm/30 s Optional with 200Nm/15S 400Nm/60S | ON - OFF Modulación Avance lento - Posicionamiento | 24 V CC CA 110V CA 220V CA 380V | 4-20 mA 0-10V Interfaz de E/S Optional with field bus Modbus-RTU Modbus-ASCII CAN Ethernet | Over torque protection Fail Safe Return Deshumidificación Autobús de campo |
| DCL-Ex60 | 0 - 90 ° | 600 Nm/45 S | ON - OFF Modulación Avance lento - Posicionamiento | 24 V CC CA 110V CA 220V CA 380V | 4-20 mA 0-10V Interfaz de E/S Optional with field bus Modbus-RTU Modbus-ASCII CAN Ethernet | Over torque protection Fail Safe Return Deshumidificación Autobús de campo |
Recommend actuator to drive a butterfly valve
Recommend actuator to drive a Ball valve
Recommend actuator to drive a ventilation valve
Recommend valve to be driven by DCL explosion-proof actuator
Note: The recommendations in the above table is for reference only in common application scenario, the specific torque needed to drive the valve is depended up on the real application case.
It is recommended to choose an actuator with 1.1-1.3 times of torque than the value that was finalized after evaluation of torque requirement of valve and liquid pressure in the pipe. This would improve the robust performance in most worst case.
View actuators with different torque
50 Nm/20 S
————————–
Optional with
20Nm/4S
30Nm/10S
50Nm/60S
100 Nm/30 s
————————–
Optional with
50Nm/15S
100Nm/60S
200 Nm/30 s
————————–
Optional with
100Nm/15S
200Nm/60S
400 Nm/30 s
————————–
Optional with
200Nm/15S
400Nm/60S