Productos

Technical Parameters

Explosion Proof GradeExd II CT4Gb
Power SupplyDC24V, AC24V, AC110V, AC220V, AC380V
Standard Torque/Time50 Nm/20 S
Optional Torque/Time20Nm/4S, 30Nm/10S, 50Nm/60S
Rotation Angle Range0~360 ° adjustable
Motor Power/CurrentDC24V: 13W/1.82A
AC24V: 10W/1.50A
AC110V: 10W/0.24A
AC220V: 10W/0.15A
AC380V: 6W /0.07A
Control CircuitType A/B/C/D/E/F/G/H
Weight3.0kg
Insulation Resistance DC24V/AC24V: 100MΩ/250VDC
AC110V/AC220V/AC380V: 100MΩ/500VDC
Withstand VoltageDC24V/AC24V: 500VAC for 1 minute
Water Proof LevelIP68
Installation360 ° installation at any angle
Electrical Interface2-M20x1.5 explosion-proof plug, users should install corresponding explosion-proof cable connectors according to the selected cable during use
Working Temperature-20℃~+60℃
Optional FunctionDehumidification heater
Modulation Parameters
Señal de entrada4~20mA, 0~10V arbitrary calibration
output Signal4~20mA, 0~10V arbitrary calibration
Bus485/Modbus/CAN
Internet of ThingsWIFI/LoRA/4G
Basic Error≤±1%
Return Error≤1%
HysteresisAdjustable from 0.5% to 5.0%
Reposition Times0 times
Repeatability Error≤1%

Dimensions

华易防爆执行器安装形式 | DCL Explosion-Proof Actuator Installation Demension
华易防爆电动执行器DCL-Ex05 外型安装尺寸

Application Circuit

Modulación

E - Modulating with a control unit

  • Input: 4~20mA / 0~10V
  • Output: 4~20mA / 0~10V
  • Field Bus:Modbus / CAN
  • IIot:WIFI/LoRA/4G DTU

 

Connecting Details:

  1. Connecting AC85-220V supply power line to L and neutral to N.
  2. Connecting 4-20mA/2-10V input signal source from control system to input-/+.
  3. Connecting Output -/+ to the system to send out the real-time valve position.

Inching and positioning

F - With a positioning unit

  • Control actuator to open or close with K
  • The real-time valve position will be send out as a 4-20mA signal.

 

Connecting Details:

  1. Connecting AC85-220V supply power line to L and neutral to N.
  2. Switch AC85-220V line to CLOSE(P2) to close the valve.
  3. Switch AC85-220V line to OPEN(P3) to open the valve.
  4. Connecting Output -/+ to the system to send out the real-time valve position.

C - With a 1KΩ/500Ω potentiometer

  • Control actuator to open or close with K
  • The real-time valve position will be send out as a potentiometer resistance value

 

Connecting Details:

  1. Connecting AC85-220V supply power neutral to P1.
  2. Switch AC85-220V line to CLOSE(P2) to close the valve
  3. Switch AC85-220V line to OPEN(P3) to open the valve.
  4. P4 is the low side of potentiometer that is normally connected to signal GND.
  5. Connecting signal input of  control system to P5. The resistance value between P4 and P5 will become higher as actuator opening the valve, while the value between P5 and P6 will become lower.
  6. P6 is the high side of potentiometer that is normally connected to signal power.
  7. Connect earth to P7.

D - With a potentiometer and end-position feedback

  • Control actuator to open or close with K
  • The real-time valve position will be send out as a potentiometer resistance value
  • The output terminal of end-position OPEN/CLOSE will send out the event as a passive signal form when the end-position was reached.

 

Connecting Details:

  1. Connecting AC85-220V supply power neutral to P1.
  2. Switch AC85-220V line to CLOSE(P2) to close the valve
  3. Switch AC85-220V line to OPEN(P3) to open the valve.
  4. P4 is the COM for passive contact signal of end-position OPEN/CLOSE which is normally connected to signal GND.
  5. P5 is end-position OPEN terminal which will be connected to COM when actuator reached end-position of open.
  6. P6 is end-position CLOSE terminal which will be connected to COM when actuator reached end-position of close.
  7. P7 is the low side of potentiometer that is normally connected to signal GND.
  8. Connecting signal input of  control system to P8. The resistance value between P7 and P8 will become higher as actuator opening the valve, while the value between P8 and P9 will become lower.
  9. P9 is the high side of potentiometer that is normally connected to signal power.
  10. Connect earth to P12.

ON - OFF

A - With 2 active end-position signal outputs

  • Control actuator to open or close with K
  • The output terminal of end-position OPEN/CLOSE will send out the event as a 220VAC active signal form when the end-position was reached.

 

Connecting Details:

  1. Connecting AC85-220V supply power neutral to P1.
  2. Switch AC85-220V line to CLOSE(P2) to close the valve
  3. Switch AC85-220V line to OPEN(P3) to open the valve.
  4. P5 is end-position OPEN terminal which will output a AC220V source which can be used to drive an Indication light when actuator reached end-position of open.
  5. P6 is end-position OPEN terminal which will output a AC220V source which can be used to drive an Indication light when actuator reached end-position of close.
  6. Connect earth to P7.

B - With 2 passive end-position switches

  • Control actuator to open or close with K
  • The output terminal of end-position OPEN/CLOSE will send out the event as a passive signal form when the end-position was reached.

 

Connecting Details:

  1. Connecting AC85-220V supply power neutral to P1.
  2. Switch AC85-220V line to CLOSE(P2) to close the valve
  3. Switch AC85-220V line to OPEN(P3) to open the valve.
  4. P4 is the COM for passive contact signal of end-position OPEN/CLOSE which is normally connected to signal GND.
  5. P5 is end-position OPEN terminal which will be connected to COM when actuator reached end-position of open.
  6. P6 is end-position CLOSE terminal which will be connected to COM when actuator reached end-position of close.
  7. Connect earth to P7.

G - DC motor with 2 end-position switches

  • Control actuator to open or close by the supply power direction between the terminal 1 and 2
  • The output terminal of end-position OPEN/CLOSE will send out the event as a passive signal form when the end-position was reached.

 

Connecting Details:

  1. Connecting DC24V+ to P1 and DC24V- to P2 to close the valve.
  2. Connecting DC24V+ to P2 and DC24V- to P1 to close the valve.
  3. P3 is the COM for passive contact signal of end-position OPEN/CLOSE which is normally connected to signal GND.
  4. P4 is end-position OPEN terminal which will be connected to COM when actuator reached end-position of open.
  5. P5 is end-position CLOSE terminal which will be connected to COM when actuator reached end-position of close.
  6. Connect earth to P7.

H - 3 phase 380VAC motor with 2 end-position switches

  • Control actuator to open or close by an external inverter to change the phase of supply power.
  • The output terminal of end-position OPEN/CLOSE will send out the event as a passive signal form when the end-position was reached.

 

Connecting Details:

  1. Connecting a 3 phase AC380V inverter output to P1, P2 and P3, then the actuator can be controlled to open or close the valve by change the 3 phase order.
  2. Connecting AC380V neutral to N(P4).
  3. P5 is used for cooperating with an external switch to control the inverter 3 phase order. This terminal is connected to N(P4) when actuator is not in end-position of CLOSE and disconnected from N(P4) after actuator reached end-position of CLOSE.
  4. P6 is used for cooperating with an external switch to control the inverter 3 phase order. This terminal is connected to N(P4) when actuator is not in end-position of OPEN and disconnected from N(P4) after actuator reached end-position of OPEN.
  5. P7 is the COM for passive contact signal of end-position OPEN/CLOSE which is normally connected to signal GND.
  6. P8 is end-position OPEN terminal which will be connected to COM when actuator reached end-position of open.
  7. P9 is end-position CLOSE terminal which will be connected to COM when actuator reached end-position of close.
  8. Connect earth to P12.

Note:

  • The circuit inside the dashed box is the internal circuit of actuator. While the circuit outside is a demonstration of electrical connection for using actuator.
  • If you have other specific requirements about connecting circuit, please feel free to contact our technical support. 

Choose another actuator with different torque​

50 Nm/20 S

————————–

Optional with

20Nm/4S

30Nm/10S

50Nm/60S

100 Nm/30 s

————————–

Optional with

50Nm/15S

100Nm/60S

 

200 Nm/30 s

————————–

Optional with

100Nm/15S

200Nm/60S

 

400 Nm/30 s

————————–

Optional with

200Nm/15S

400Nm/60S

 

Solicitud de cotización

Pulse "Enviar" ahora; más adelante le confirmaremos el número de modelo del producto y el distribuidor local, y luego le enviaremos el presupuesto.

WhatsApp

Escanea el código QR para chatear con nuestro ingeniero ahora...

Solicitud de cotización

Pulse "Enviar" ahora; más adelante le confirmaremos el número de modelo del producto y el distribuidor local, y luego le enviaremos el presupuesto.

WhatsApp

Escanea el código QR para chatear con nuestro ingeniero ahora...

Solicitud de cotización

Pulse "Enviar" ahora; más adelante le confirmaremos el número de modelo del producto y el distribuidor local, y luego le enviaremos el presupuesto.

WhatsApp

Escanea el código QR para chatear con nuestro ingeniero ahora...

🤝 Construyamos tu marca juntos

✅ ODM

  • Su logotipo y embalaje
  • Formatos de salida personalizados (4-20 mA, RS485 Modbus, HART, etc.)
  • Cambios en el color o la etiqueta de la carcasa
  • Versiones preparadas para la nube (opcional)

✅ OEM

  • Siga estrictamente su diseño y especificaciones.
  • Confidencialidad absoluta y protección de la propiedad intelectual.
  • Producción de alta calidad a un precio competitivo.
  • Producción en lotes pequeños o a gran escala
  • 🏭 Investigación y desarrollo y fabricación internasDesde la placa de circuito impreso hasta la carcasa, todo bajo un mismo techo.
  • 💬 Soporte multilingüeIngenieros y personal de ventas que hablen inglés.

  • ⚙️ Cantidad mínima de pedido flexible: Apoyo tanto para empresas emergentes como para marcas globales.

  • 🚀 Prototipado rápidoEntrega de muestras en 7-10 días.

 Contáctanos hoy Para solicitar un catálogo de productos o una consulta gratuita.

Solicitud de cotización

Enviar consulta

WhatsApp

Escanea el código QR para chatear con nuestro ingeniero ahora...

Contáctanos

Teléfono

(+86) 130 2633 1611

WhatsApp

Ken Bryan

即时客服图标 | Icono de mensaje en vivo

Chat en el sitio

Haz clic en el icono de la esquina inferior derecha para chatear con nosotros...