Technical Parameters
Range | -0.1 ~ 100MPa |
Pressure type | Gauge pressure; Sealed gauge pressure; Absolute pressure |
Accuracy | 0.1/0.25/0.5% optional |
Long-term Stability | ≤± 0.25%/year |
Overload Pressure | 2 times the full Range pressure or 110MPa |
Supply Voltage | 9 ~ 30VDC |
output Signal | 4~20mA; 0~5V/10V; RS485 · Modbus-RTU · ASCII |
Working Temperature | -30 ~ 80℃ |
Storage Temperature | -40 ~ 85℃ |
Vibration | 20g, 20 ~ 2000Hz |
Shock | 10g, 11ms |
Water Proof Level | IP65 |
Dimension
Unit: mm

Materials
Contact Parts to Measuring Object
Isolation Membrane: Stainless Steel 316L/Tantalum
Connection Interface: Stainless Steel 304/Stainless Steel 316L/Hastelloy C
Process Connection
M20×1.5 Male thread, face seal

M20×1.5 Male Thread, Waterline Seal

M20×1.5 Flush Membrane

G1/4 Male Thread, Face Seal

G1/2 Male Thread, Face Seal

G1/2 Flush Membrane

Cable Gland
Hussman Plug

Common cable: cable diameter ranging from 5.5mm to 6.5mm
Electrical Connection
4-20mA with 2 Wire

0-10V | 2-10V | 0-5V | 1-5V

RS485 | Modbus_RTU | Modbus_ASCII

Output Signal Capacity
4-20mA : ≤ (U-10)/0.02 (Ω)
RS485 : 99 Nodes