Standards – ISO/EU/GB
Application Notes of DCL Actuator
Previous : User Manual of DCL Actuator
Hvordan styre DCL-aktuatoren via modbus med vaTestTool_DCL.exe

1. Åpne vaTestTool_DCL-v1.31.exe. 2. Programmet viser en "Koble til"-dialogboks for å angi målenhetens id og den lokale datamaskinens RS232-portparametere på følgende måte. Velg COM-porten som er koblet til USB-RS485-kontakten. Velg modbus baudrate (standard baudrate på DCL-aktuatoren er nå 9600). Klikk på "CONNECT"-knappen for å koble til [...].
How to choose an actuator?
Determining Specific Valve Drive Parameters For precise fluid control applications, it is essential to define the final valve drive parameters based on factors such as fluid pressure, media type, and control method. This ensures that the selected electric actuator meets the operational requirements. The following parameters should be determined before finalizing the actuator model: Choose […]
DCL-aktuator med FSR Brukerhåndbok
DCL-aktuator med FSR-betjeningspanel Tilkobling P1:DC24V strøm + P3:DC24V strøm - P5:4-20mA inngang - P7:4-20mA inngang + P9:4-20mA utgang - P11:4-20mA utgang - P11:4-20mA Output + P2:ON/OFF Input COM P4:ON/OFF Input Open P6:ON/OFF Input Close P8:ON/OFF Output COM P10:ON/OFF Output Open P12:ON/OFF Output Close Knapp KO: Brukes i innstillingsmodus. Trykk på denne knappen for å åpne [...]
DCL Actuator Modbus Application Manual(Envision Version)
Service & Support The DCL series actuators support the Modbus-RTU protocol. By referring to this application manual, you can connect the DCL actuator to Modbus. Panel Description 1. Interface Definition P1: 220VAC Neutral (N) P2: 220VAC Live (L) P3: 4-20mA Input – P4: 4-20mA Input + P5: 4-20mA Output – P6: 4-20mA Output + […]
DC-FB3 Brukerhåndbok
The DC-FB3 module, when installed in the DCL electric actuator, allows for controlling the valve’s position using Modbus-TCP/IP. The installation is shown below: 1. Controlling DCL Electric Actuator via Modbus-TCP/IP Using Default Parameters The DC-FB3 is pre-configured in Client mode. Using the default MAC, IP, Gateway, Server, and Port parameters, you can control the […]
DC-FB1 Brukerhåndbok
The DC-FB1 is a USB to RS485 converter, enabling communication between a computer and a device using the RS485 protocol. This manual provides the necessary steps to get your DC-FB1 up and running, enabling you to communicate with RS485 devices from your computer. Here’s how to set it up: Connecting DC-FB1 to the Computer 1.Plug […]
JB/T 8219—2016 Standard for Ordinary and Intelligent Electric Actuators Used in Industrial Process Control Systems
Table of Contents Preface 1 Scope 2 Normative References 3 Terms and Definitions 4 Product Classification and Basic Parameters 4.1 Product Classification 4.2 Basic Parameters 5 Basic Functions of Intelligent Actuators 5.1 Display Function 5.2 Parameter Setting Function 5.3 On-Site Configuration Function 5.4 Fault Self-Diagnosis and Alarm Function 5.5 Communication Function 5.6 Other Functions 6 […]
GB/T 3369.1—2008/IEC 60381-1:1982
The standard for the 4-20mA current signal used in electric actuators is as follows: Standard: GB/T 3369.1—2008/IEC 60381-1:1982 Title: Analogue signals for process control systems — Part 1: Direct current signals (IEC 60381-1:1982, IDT) This standard defines the specifications for analog signals, specifically for the use of direct current (DC) signals in process control systems, […]