How many years have you been making actuators? How is the product quality?DCL was founded in 2001 and has been specializing in the design, production, and sales of reliable, durable, and compact electric actuators for 22 years. So far, DCL actuators have been used in 13 countries, by over 270 customers, and in more than […]
User Manual of DCL Actuator
Previous : How-tos of DCL Actuator Next : Application Notes of DCL Actuator
How the DC24V ON-OFF Type Actuator (Electric Valve) Works
When you install a DCL 24V ON-OFF type electric control valve on a pipeline, you can control it using a relay, ON-OFF control, or PLC (DCS), enabling the opening or shutting off of fluid flow. This guide explains how the DCL 24V ON-OFF type electric actuators function using relays, PLCs, or ON-OFF control for valve […]
How the AC220V ON-OFF Type Actuator (Electric Valve) Works
When you install a DCL AC220V ON-OFF type electric control valve on a pipeline, you can control it using a relay, ON-OFF control, or PLC (DCS), enabling the opening or shutting off of fluid flow. This guide explains how the DCL AC220V ON-OFF type electric actuators function using relays, PLCs, or ON-OFF control for valve […]
Richiesta tecnica
[email protected] Phone (+86) 130 2633 1611 WhatsApp Ken Bryan In site chat Click on the icon at the bottom right corner to chat with us…
Come calibrare il segnale di ingresso dell'attuatore?

When the actuator’s valve position does not match the 4–20mA input signal (resulting in a discrepancy between the feedback signal and the input signal), you can calibrate the input signal to eliminate this deviation. 6 Simple Steps for Calibration: Turn the S-A switch to position 2. Press and hold the Set button until the L2 […]
Utilizzo dell'IoT per monitorare e analizzare i guasti intermittenti degli attuatori.
Feedback del cliente: La valvola a tre vie nel sistema di raffreddamento non raggiunge la posizione designata Un cliente del settore nucleare ha segnalato un guasto intermittente dell'attuatore. Nello specifico, dopo che il sistema di controllo ha emesso un comando di apertura tramite un segnale 4-20mA, la posizione di feedback dell'attuatore è rimasta invariata. Dopo aver interrotto l'alimentazione e ispezionato il sito, […]
Guasti comuni e risoluzione dei problemi per attuatori modulanti a 24 V CC
This guide is applicable to the DCL Explosion-proof Series / Weather-proof Series / Quick-Turning Series of modulating actuators powered by DC24V, with the following models: Weather-proof Actuator: DCL-02GEY, DCL-05GEY, DCL-10GEY, DCL-20GEY, DCL-40GEY, DCL-60GEY Explosion-proof Actuator: DCL-Ex05GEY, DCL-Ex10GEY, DCL-Ex20GEY, DCL-Ex40GEY, DCL-Ex60GEY Let me know if you need further assistance with this guide! Open the Electric Chamber […]
Guasti comuni e risoluzione dei problemi per gli attuatori ON-OFF DCL-02
This guide is applicable to the DCL Ultra-Small Series actuators, with the following models: DCL-02A DCL-02B DCL-02G Common Faults and Troubleshooting Methods Fault Possible Causes Troubleshooting Methods Actuator does not open or close on initial start 1. Incorrect wiring Check the wiring according to the actuator’s wiring diagram. 2. Incorrect power supply Ensure […]
Guasti comuni e risoluzione dei problemi per gli attuatori modulanti DCL-02
This guide applies to the DCL ultra small modulating actuators, model as follows: DCL-02E Common Faults and Troubleshooting Methods Fault Possible Cause Troubleshooting Method Actuator will not open or close at startup 1. Incorrect wiring Check the wiring according to the actuator wiring diagram to confirm it is correct. 2. Incorrect power supply […]