Products

Ultra Small Actuator

DCL-02

  • Small size same as a cola can
  • High-strength aluminum alloy shell for strong protection.
  • High EMI performance.
华易精巧型执行器 | Very Small Actuator
华易精巧型执行器 特点 | DCL-02 Features

Bewegungsrichtung

Teildrehung
Dämpfer
0 - 270°

Drehmoment/Betriebszeit

9~18Nm
7~60S

Art der Tätigkeit

Modulieren
On - Off

Versorgungsspannung

24 V DC
AC110V
AC220V

Eingangs-/Ausgangssignal

4 - 20 mA
0 - 10 V
E/A-Schnittstelle

Zusätzliche Optionen

Entfeuchtung

Art der Tätigkeit

Modulieren

华易调节型执行器 控制示意图

The actuator read the target position value from control system through 4-20mA, 2-10V or field bus such as modbus, ethernet and etc.

Then actuator drive the valve to the target position with interior control algorithm.

The actuator will always output the real-time valve position through 4-20mA, 2-10V or field bus.

Operated in type of duty S4, the actuator can starts 1200 times per hour.

On - Off

DCL 华易开关型执行器 控制示意图

The actuator read the open or close requirement from control system through IO interface such as passive signal or 24VDC/220VAC active signal.

Then actuator drive the valve to the end-position of OPEN or CLOSE as input signal required.

The actuator will output a feedback signal of OPEN or CLOSE when end-position been reached.

Operated in type of duty S2, the actuator can drive valve continuously for 15 minutes.

Features

Motor with Over Temperature Protection

DCL 华易普通型执行器 过热保护

DCL specially design the motor to fit the actuator requirement so that the motor in DCL actuator can supply a high start torque while maintain a high efficiency in the start phase to make the temperature rise as low as possible. In the meantime the motor have a small moment of inertia to make sure the high precision in modulation.

There is an over temperature protection device mounted in the motor which will cut the power supply when the motor temperature goes higher then the limited temperature(105℃/85℃ can be selected up on the application scenario) and connect the power supply again when the temperature recovered below the Normal temperature.

Dual Position Limiter

DCL 华易执行器限位示意图

There are 2 position limit devices to protect valve from damage by operation over swing angle.

Electric limit switch are mounted on the both end-position of OPEN and CLOSE. So the power supply to motor will be cut off to stop driving the valve after limited end-position was reached.

Also there are 2 mechanical limiters  mounted on the output shaft to protect the valve from swing over stroke range. The mechanical limiter will not take effect in normal operation cause the electric limit switch is ahead of the mechanical limiter and will be triggered before the output shaft can reach the mechanical limited positon. 

Technical Parameters

Power SupplyDC24V, AC24V, AC110V, AC220V
Standard Torque/Time18Nm/15S
Optional Torque/Time9Nm/7S, 18Nm/60S
Rotation Angle Range0~90°
Motor Power/CurrentDC24V:8W / 0.7A
AC24V:6W / 1.3A
AC110V: 6W / 0.3A
AC220V:6W / 0.15A
Control CircuitDC24V: E-type/G-type
Weight1.2kg
Insulation Resistance DC24V/AC24V:100MΩ/250VDC
AC110V/AC220V:100MΩ/500VDC
Withstand VoltageDC24V/AC24V: 500VAC for 1 minute
Water Proof LevelIP67
Installation orientation360 ° installation at any angle
Electrical Interface7-core cable connection
Working Temperature-25℃ ~ +55℃
Selection of fusesDC24V:2A
AC24V:3A
AC110V/AC220V:1A
DCL-02 Adjustable Control Parameters
Eingangssignal4~20mA, 0~10V arbitrary calibration
output Signal4~20mA, 0~10V arbitrary calibration
Bus485/Modbus/CAN
Internet of ThingsWIFI/LoRA/4G
Basic Error≤±1%
Check back≤1%
HysteresisAdaptive Hysteresis, customized
Reposition Times0 times
Repeatability Error≤1%

Dimensions

华易DCL-02 外型安装尺寸图

Application Circuit

Modulieren

E - Modulating with a control unit

  • Input: 4~20mA / 0~10V
  • Output: 4~20mA / 0~10V

 

Connecting Details:

  1. Connecting AC85-220V supply power line to L and neutral to N.
  2. Connecting 4-20mA/2-10V input signal source from control system to input-/+.
  3. Connecting Output -/+ to the system to send out the real-time valve position.

On - Off

A - With 2 active end-position signal outputs

  • Control actuator to open or close with K
  • The output terminal of end-position OPEN/CLOSE will send out the event as a 220VAC active signal form when the end-position was reached.

 

Connecting Details:

  1. Connecting AC85-220V supply power neutral to P1.
  2. Switch AC85-220V line to CLOSE(P2) to close the valve
  3. Switch AC85-220V line to OPEN(P3) to open the valve.
  4. P5 is end-position OPEN terminal which will output a AC220V source which can be used to drive an Indication light when actuator reached end-position of open.
  5. P6 is end-position OPEN terminal which will output a AC220V source which can be used to drive an Indication light when actuator reached end-position of close.
  6. Connect earth to P7.

B - With 2 passive end-position switche

  • Control actuator to open or close with K
  • The output terminal of end-position OPEN/CLOSE will send out the event as a passive signal form when the end-position was reached.

 

Connecting Details:

  1. Connecting AC85-220V supply power neutral to P1.
  2. Switch AC85-220V line to CLOSE(P2) to close the valve
  3. Switch AC85-220V line to OPEN(P3) to open the valve.
  4. P4 is the COM for passive contact signal of end-position OPEN/CLOSE which is normally connected to signal GND.
  5. P5 is end-position OPEN terminal which will be connected to COM when actuator reached end-position of open.
  6. P6 is end-position CLOSE terminal which will be connected to COM when actuator reached end-position of close.
  7. Connect earth to P7.

G - DC motor with 2 end-position switches

  • Control actuator to open or close by the supply power direction between the terminal 1 and 2
  • The output terminal of end-position OPEN/CLOSE will send out the event as a passive signal form when the end-position was reached.

 

Connecting Details:

  1. Connecting DC24V+ to P1 and DC24V- to P2 to close the valve.
  2. Connecting DC24V+ to P2 and DC24V- to P1 to close the valve.
  3. P3 is the COM for passive contact signal of end-position OPEN/CLOSE which is normally connected to signal GND.
  4. P4 is end-position OPEN terminal which will be connected to COM when actuator reached end-position of open.
  5. P5 is end-position CLOSE terminal which will be connected to COM when actuator reached end-position of close.
  6. Connect earth to P7.

Note:

  • The circuit inside the dashed box is the internal circuit of actuator. While the circuit outside is a demonstration of electrical connection for using actuator.
  • If you have other specific requirements about connecting circuit, please feel free to contact our technical support. 

Angebotsanfrage

Drücken Sie jetzt auf „Senden“. Wir bestätigen Ihnen später die Produktmodellnummer und den lokalen Händler und senden Ihnen dann das Angebot zu.

WhatsApp

Scannen Sie den QR-Code, um jetzt mit unserem Techniker zu chatten...

Angebotsanfrage

Drücken Sie jetzt auf „Senden“. Wir bestätigen Ihnen später die Produktmodellnummer und den lokalen Händler und senden Ihnen dann das Angebot zu.

WhatsApp

Scannen Sie den QR-Code, um jetzt mit unserem Techniker zu chatten...

Angebotsanfrage

Drücken Sie jetzt auf „Senden“. Wir bestätigen Ihnen später die Produktmodellnummer und den lokalen Händler und senden Ihnen dann das Angebot zu.

WhatsApp

Scannen Sie den QR-Code, um jetzt mit unserem Techniker zu chatten...

🤝 Lass uns gemeinsam deine Marke aufbauen.

✅ ODM

  • Ihr Logo & Ihre Verpackung
  • Benutzerdefinierte Ausgabeformate (4-20mA, RS485 Modbus, HART usw.)
  • Änderungen der Gehäusefarbe oder der Etiketten
  • Cloudfähige Versionen (optional)

✅ OEM

  • Halten Sie sich strikt an Ihre Konstruktionsvorgaben und Spezifikationen.
  • Vollständige Vertraulichkeit und Schutz des geistigen Eigentums
  • Hochwertige Produktion zu wettbewerbsfähigen Kosten
  • Kleinserien- oder Großserienproduktion
  • 🏭 Eigene Forschung und Entwicklung & FertigungVon der Leiterplatte bis zum Gehäuse – alles unter einem Dach.
  • 💬 Mehrsprachige UnterstützungEnglischsprachige Ingenieure und Vertriebsmitarbeiter.

  • ⚙️ Flexible MindestbestellmengeUnterstützung für Startups und globale Marken.

  • 🚀 Schnelles Prototyping: Musterlieferung in 7–10 Tagen.

 Kontaktieren Sie uns noch heute. Um einen Produktkatalog anzufordern oder eine kostenlose Beratung zu erhalten.

Angebotsanfrage

Anfrage senden

WhatsApp

Scannen Sie den QR-Code, um jetzt mit unserem Techniker zu chatten...

Kontaktieren Sie uns

Telefon

(+86) 130 2633 1611

WhatsApp

Ken Bryan

即时客服图标 | Symbol für Live-Nachricht

Chat auf der Website

Klicken Sie auf das Symbol unten rechts, um mit uns zu chatten...