How to control DCL actuator through modbus by vaTestTool_DCL.exe

How to control DCL actuator through modbus by vaTestTool_DCL.exe

1.Open vaTestTool_DCL-v1.31.exe. 2.The application will popup a “Connect to” dialog to set the target device id and local computer RS232 port parameters as follow. Choose the COM port which connected to the USB-RS485 connector. Select the modbus baud rate (the default baudrate on DCL actuator now is 9600). Click on “CONNECT”button to connect to the […]

Wie wählt man einen Aktor aus?

Determining Specific Valve Drive Parameters For precise fluid control applications, it is essential to define the final valve drive parameters based on factors such as fluid pressure, media type, and control method. This ensures that the selected electric actuator meets the operational requirements. The following parameters should be determined before finalizing the actuator model: Choose […]

DCL Actuator with FSR User Manual

DCL Actuator with FSR Operation Panel Connection P1:DC24V Power + P3:DC24V Power – P5:4-20mA Input – P7:4-20mA Input + P9:4-20mA Output – P11:4-20mA Output + P2:ON/OFF Input COM P4:ON/OFF Input Open P6:ON/OFF Input Close P8:ON/OFF Output COM P10:ON/OFF Output Open P12:ON/OFF Output Close Button KO: Used in setting mode. Press this button to open the […]

DCL Actuator Modbus Application Manual(Envision Version)

Service & Support The DCL series actuators support the Modbus-RTU protocol. By referring to this application manual, you can connect the DCL actuator to Modbus. Panel Description   1. Interface Definition P1: 220VAC Neutral (N) P2: 220VAC Live (L) P3: 4-20mA Input – P4: 4-20mA Input + P5: 4-20mA Output – P6: 4-20mA Output + […]

DC-FB3 User Manual

The DC-FB3 module, when installed in the DCL electric actuator, allows for controlling the valve’s position using Modbus-TCP/IP. The installation is shown below:   1. Controlling DCL Electric Actuator via Modbus-TCP/IP Using Default Parameters The DC-FB3 is pre-configured in Client mode. Using the default MAC, IP, Gateway, Server, and Port parameters, you can control the […]

DC-FB1 User Manual

The DC-FB1 is a USB to RS485 converter, enabling communication between a computer and a device using the RS485 protocol. This manual provides the necessary steps to get your DC-FB1 up and running, enabling you to communicate with RS485 devices from your computer. Here’s how to set it up: Connecting DC-FB1 to the Computer 1.Plug […]

JB/T 8219—2016 Standard für gewöhnliche und intelligente elektrische Stellantriebe, die in industriellen Prozessleitsystemen verwendet werden

Table of Contents Preface 1 Scope 2 Normative References 3 Terms and Definitions 4 Product Classification and Basic Parameters 4.1 Product Classification 4.2 Basic Parameters 5 Basic Functions of Intelligent Actuators 5.1 Display Function 5.2 Parameter Setting Function 5.3 On-Site Configuration Function 5.4 Fault Self-Diagnosis and Alarm Function 5.5 Communication Function 5.6 Other Functions 6 […]

GB/T 3369.1—2008/IEC 60381-1:1982

The standard for the 4-20mA current signal used in electric actuators is as follows: Standard: GB/T 3369.1—2008/IEC 60381-1:1982 Title: Analogue signals for process control systems — Part 1: Direct current signals (IEC 60381-1:1982, IDT) This standard defines the specifications for analog signals, specifically for the use of direct current (DC) signals in process control systems, […]

Angebotsanfrage

Drücken Sie jetzt auf „Senden“. Wir bestätigen Ihnen später die Produktmodellnummer und den lokalen Händler und senden Ihnen dann das Angebot zu.

WhatsApp

Scannen Sie den QR-Code, um jetzt mit unserem Techniker zu chatten...

Angebotsanfrage

Drücken Sie jetzt auf „Senden“. Wir bestätigen Ihnen später die Produktmodellnummer und den lokalen Händler und senden Ihnen dann das Angebot zu.

WhatsApp

Scannen Sie den QR-Code, um jetzt mit unserem Techniker zu chatten...

Angebotsanfrage

Drücken Sie jetzt auf „Senden“. Wir bestätigen Ihnen später die Produktmodellnummer und den lokalen Händler und senden Ihnen dann das Angebot zu.

WhatsApp

Scannen Sie den QR-Code, um jetzt mit unserem Techniker zu chatten...

🤝 Lass uns gemeinsam deine Marke aufbauen.

✅ ODM

  • Ihr Logo & Ihre Verpackung
  • Benutzerdefinierte Ausgabeformate (4-20mA, RS485 Modbus, HART usw.)
  • Änderungen der Gehäusefarbe oder der Etiketten
  • Cloudfähige Versionen (optional)

✅ OEM

  • Halten Sie sich strikt an Ihre Konstruktionsvorgaben und Spezifikationen.
  • Vollständige Vertraulichkeit und Schutz des geistigen Eigentums
  • Hochwertige Produktion zu wettbewerbsfähigen Kosten
  • Kleinserien- oder Großserienproduktion
  • 🏭 Eigene Forschung und Entwicklung & FertigungVon der Leiterplatte bis zum Gehäuse – alles unter einem Dach.
  • 💬 Mehrsprachige UnterstützungEnglischsprachige Ingenieure und Vertriebsmitarbeiter.

  • ⚙️ Flexible MindestbestellmengeUnterstützung für Startups und globale Marken.

  • 🚀 Schnelles Prototyping: Musterlieferung in 7–10 Tagen.

 Kontaktieren Sie uns noch heute. Um einen Produktkatalog anzufordern oder eine kostenlose Beratung zu erhalten.

Angebotsanfrage

Anfrage senden

WhatsApp

Scannen Sie den QR-Code, um jetzt mit unserem Techniker zu chatten...

Kontaktieren Sie uns

Telefon

(+86) 130 2633 1611

WhatsApp

Ken Bryan

即时客服图标 | Symbol für Live-Nachricht

Chat auf der Website

Klicken Sie auf das Symbol unten rechts, um mit uns zu chatten...