Compare parameters between DCL explosion-proof actuators
| Model | Schwenkwinkel | Drehmoment/Betriebszeit | Duty Type | Versorgungsspannung | Eingangs-/Ausgangssignal | Additional Option |
|---|---|---|---|---|---|---|
| DCL-Ex05 | 0 - 360 ° | 50 Nm/20 s Optional mit 20 Nm/4S 30 Nm/10 s 50 Nm/60 s | ON - OFF Modulieren Schrittweise Positionierung | 24 V DC AC24V AC110V AC220V AC380V | 4-20 mA 0-10 V E/A-Schnittstelle Optional with field bus Modbus-RTU Modbus-ASCII CAN Ethernet | Over torque protection Ausfallsichere Rückkehr Entfeuchtung Feldbus |
| DCL-Ex10 | 0 - 90 ° | 100 Nm/30 s Optional mit 50 Nm/15 s 100 Nm/60 s | ON - OFF Modulieren Schrittweise Positionierung | 24 V DC AC24V AC110V AC220V AC380V | 4-20 mA 0-10 V E/A-Schnittstelle Optional with field bus Modbus-RTU Modbus-ASCII CAN Ethernet | Over torque protection Ausfallsichere Rückkehr Entfeuchtung Feldbus |
| DCL-Ex20 | 0 - 90 ° | 200 Nm/30 s Optional mit 100 Nm/15 s 200 Nm/60 s | ON - OFF Modulieren Schrittweise Positionierung | 24 V DC AC110V AC220V AC380V | 4-20 mA 0-10 V E/A-Schnittstelle Optional with field bus Modbus-RTU Modbus-ASCII CAN Ethernet | Over torque protection Ausfallsichere Rückkehr Entfeuchtung Feldbus |
| DCL-Ex40 | 0 - 90 ° | 400 Nm/30 s Optional mit 200 Nm/15 s 400 Nm/60 s | ON - OFF Modulieren Schrittweise Positionierung | 24 V DC AC110V AC220V AC380V | 4-20 mA 0-10 V E/A-Schnittstelle Optional with field bus Modbus-RTU Modbus-ASCII CAN Ethernet | Over torque protection Ausfallsichere Rückkehr Entfeuchtung Feldbus |
| DCL-Ex60 | 0 - 90 ° | 600 Nm/45 s | ON - OFF Modulieren Schrittweise Positionierung | 24 V DC AC110V AC220V AC380V | 4-20 mA 0-10 V E/A-Schnittstelle Optional with field bus Modbus-RTU Modbus-ASCII CAN Ethernet | Over torque protection Ausfallsichere Rückkehr Entfeuchtung Feldbus |
Recommend actuator to drive a butterfly valve
Recommend actuator to drive a Ball valve
Recommend actuator to drive a ventilation valve
Recommend valve to be driven by DCL explosion-proof actuator
Note: The recommendations in the above table is for reference only in common application scenario, the specific torque needed to drive the valve is depended up on the real application case.
It is recommended to choose an actuator with 1.1-1.3 times of torque than the value that was finalized after evaluation of torque requirement of valve and liquid pressure in the pipe. This would improve the robust performance in most worst case.
View actuators with different torque
50 Nm/20 s
————————–
Optional mit
20 Nm/4S
30 Nm/10 s
50 Nm/60 s
100 Nm/30 s
————————–
Optional mit
50 Nm/15 s
100 Nm/60 s
200 Nm/30 s
————————–
Optional mit
100 Nm/15 s
200 Nm/60 s
400 Nm/30 s
————————–
Optional mit
200 Nm/15 s
400 Nm/60 s