{"id":5380,"date":"2023-06-05T16:19:39","date_gmt":"2023-06-05T08:19:39","guid":{"rendered":"http:\/\/www.dcl-controls.com\/?p=5380"},"modified":"2025-03-31T09:18:37","modified_gmt":"2025-03-31T09:18:37","slug":"why-voltage-signal-oscillate","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/zh_hk\/%e6%94%af%e6%8f%b4\/ta-acutator\/why-voltage-signal-oscillate","title":{"rendered":"\u70ba\u4ec0\u9ebc\u96fb\u58d3\u8f38\u51fa\u4fe1\u865f\u6703\u5728\u67d0\u4e9b\u689d\u4ef6\u4e0b\u632f\u76ea\uff1f"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"5380\" class=\"elementor elementor-5380\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-1893469 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"1893469\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-61d5be0\" data-id=\"61d5be0\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f64e7bf elementor-widget elementor-widget-text-editor\" data-id=\"f64e7bf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>\u00a0<\/h3><h2><strong>1. Voltage Signal Transmission Path<\/strong><\/h2><figure style=\"width: 960px\" class=\"wp-caption alignnone\"><img fetchpriority=\"high\" decoding=\"async\" src=\"\/wp-content\/uploads\/2023\/06\/voltage-signal-path.webp\" alt=\"Fig. 1 Transmission path of voltage source signals\" width=\"960\" height=\"299\" \/><figcaption class=\"wp-caption-text\">Fig. 1 Transmission path of voltage source signals<\/figcaption><\/figure><p>As shown in <strong>Figure 1<\/strong>, a voltage signal transmission system consists of three key components:<\/p><ol><li><p><strong>Negative feedback voltage output circuit<\/strong><\/p><\/li><li><p><strong>Signal transmission cable<\/strong><\/p><ul><li><p>Includes <strong>parasitic capacitance (C1)<\/strong> \u548c <strong>parasitic inductance (L1)<\/strong>, which depend on <strong>cable length<\/strong> \u548c <strong>wiring layout<\/strong>.<\/p><\/li><\/ul><\/li><li><p><strong>Input signal acquisition circuit<\/strong><\/p><ul><li><p>May include a <strong>low-pass filter (L2, C2)<\/strong>.<\/p><\/li><\/ul><\/li><\/ol><hr \/><h2><strong>2. Why Does Oscillation Occur?<\/strong><\/h2><p>In a negative feedback voltage signal system, the input signal is calculated as:<\/p><p><span class=\"katex\">\u2223Xi\u2032\u2223=\u2223Xi\u2223\u2212\u2223Xf\u2223|X_i&#8217;| = |X_i| &#8211; |X_f|<\/span><\/p><p>However, if the <strong>feedback signal (|Xf|) is phase-shifted by 180\u00b0<\/strong>, the equation changes to:<\/p><p><span class=\"katex\">\u2223Xi\u2032\u2223=\u2223Xi\u2223+\u2223Xf\u2223|X_i&#8217;| = |X_i| + |X_f|<\/span><\/p><p>This means that even if <strong>no input signal<\/strong> is applied (<strong>|Xi| = 0<\/strong>), the <strong>feedback signal sustains the output<\/strong>\u5c0e\u81f4 <strong>self-sustaining oscillation<\/strong>.<\/p><p>For oscillation to occur, two conditions must be met:<\/p><ol><li><p><strong>Loop gain is greater than 1:<\/strong> <strong>|AF| &gt; 1<\/strong><\/p><\/li><li><p><strong>Phase shift satisfies:<\/strong> <strong>\u03c6A + \u03c6F = (2n+1)\u03c0<\/strong><\/p><\/li><\/ol><p>\u7684 <strong>phase shift<\/strong> in the loop comes from multiple sources:<br \/>\u2714 <strong>Parasitic capacitance (C1) and inductance (L1) in the transmission cable<\/strong><br \/>\u2714 <strong>Low-pass filter components (L2, C2) in the input circuit<\/strong><br \/>\u2714 <strong>Filter capacitors in the output circuit<\/strong><\/p><p>\u5982\u679c <strong>total phase shift reaches 180\u00b0<\/strong>, self-oscillation can occur.<\/p><hr \/><h2><strong>3. How to Prevent Oscillation?<\/strong><\/h2><p>To prevent oscillation, <strong>one of the two conditions above must not be met<\/strong> within the operational frequency range.<\/p><figure style=\"width: 417px\" class=\"wp-caption alignnone\"><img decoding=\"async\" class=\"size-medium\" src=\"\/wp-content\/uploads\/2023\/06\/self-excited-oscilation-factor.webp\" alt=\"Fig. 2 Condition of negative feedback loop without oscillation\" width=\"417\" height=\"415\" \/><figcaption class=\"wp-caption-text\">Fig. 2 Condition of negative feedback loop without oscillation<\/figcaption><\/figure><p>As shown in <strong>Figure 2<\/strong>, two critical frequencies are considered:<\/p><ul><li><p><strong>fc:<\/strong> The frequency where loop gain <strong>|AF| drops to 0 dB<\/strong>.<\/p><\/li><li><p><strong>fo:<\/strong> The frequency where loop phase shift exceeds <strong>-180\u00b0<\/strong>.<\/p><\/li><\/ul><p>To maintain stability, the <strong>gain should be below 0 dB<\/strong> when the phase shift reaches -180\u00b0.<\/p><hr \/><h2><strong>4. Why Current Output Signals Are More Stable<\/strong><\/h2><figure style=\"width: 600px\" class=\"wp-caption alignnone\"><img decoding=\"async\" class=\"size-medium\" src=\"\/wp-content\/uploads\/2023\/06\/current-signal-feedback-path.webp\" alt=\"Fig. 3 Current source feedback loop\" width=\"600\" height=\"406\" \/><figcaption class=\"wp-caption-text\">Fig. 3 Current source feedback loop<\/figcaption><\/figure><figure style=\"width: 586px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium\" src=\"\/wp-content\/uploads\/2023\/06\/voltage-signal-feedback-path.webp\" alt=\"Fig. 4 Voltage source feedback loop\" width=\"586\" height=\"425\" \/><figcaption class=\"wp-caption-text\">Fig. 4 Voltage source feedback loop<\/figcaption><\/figure><p><strong>Current signal output circuits<\/strong> are less prone to oscillation because:<br \/>\u2714 <strong>Their feedback path is confined to internal components<\/strong> (as shown in <strong>Figure 3<\/strong>).<br \/>\u2714 <strong>External load variations have little effect on phase shift or gain<\/strong>.<\/p><p>In contrast, <strong>voltage output circuits<\/strong> (Figure 4) take feedback from the <strong>output point<\/strong>, meaning that <strong>external cables and sampling circuits<\/strong> can influence phase shift and gain. If their parameters change, the system <strong>may meet the oscillation conditions<\/strong>, leading to instability.<\/p><hr \/><h3><strong>5.Conclusion<\/strong><\/h3><p>Voltage-type output signals can oscillate when:<br \/>\u2714 <strong>Parasitic components introduce a 180\u00b0 phase shift.<\/strong><br \/>\u2714 <strong>Loop gain remains greater than 1 at this phase shift.<\/strong><\/p><p>To avoid oscillation:<br \/>\u2714 <strong>Ensure loop gain is reduced below 0 dB before phase shift reaches 180\u00b0.<\/strong><br \/>\u2714 <strong>Minimize parasitic capacitance\/inductance in transmission cables.<\/strong><br \/>\u2714 <strong>Use appropriate filtering to stabilize the feedback loop.<\/strong><\/p><p>In contrast, <strong>current-type outputs<\/strong> are more stable since their <strong>feedback loop is less affected by external load conditions<\/strong>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>\u00a0 1. \u96fb\u58d3\u8a0a\u865f\u50b3\u8f38\u8def\u5f91 \u5982\u5716 1 \u6240\u793a\uff0c\u96fb\u58d3\u8a0a\u865f\u50b3\u8f38\u7cfb\u7d71\u7531\u4e09\u500b\u95dc\u9375\u7d44\u4ef6\u69cb\u6210\uff1a\u8ca0\u56de\u6388\u96fb\u58d3\u8f38\u51fa\u96fb\u8def\u3001\u8a0a\u865f\u50b3\u8f38\u96fb\u7e9c\uff08\u5305\u62ec\u5bc4\u751f\u96fb\u5bb9 (C1) \u548c\u5bc4\u751f\u96fb\u611f (L1)\uff0c\u5176\u503c\u53d6\u6c7a\u65bc\u96fb\u7e9c\u9577\u5ea6\u548c\u4f48\u7dda\u4f48\u5c40\uff09\u3001\u8f38\u5165\u8a0a\u865f\u64f7\u53d6\u96fb\u8def\uff08\u53ef\u80fd\u5305\u62ec\u4f4e\u901a\u6ffe\u6ce2\u5668 (L2, [\u2026]\uff09\u3002<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[8],"tags":[49],"class_list":["post-5380","post","type-post","status-publish","format-standard","hentry","category-ta-acutator","tag-input-signal"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/zh_hk\/wp-json\/wp\/v2\/posts\/5380","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/zh_hk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/zh_hk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/zh_hk\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/zh_hk\/wp-json\/wp\/v2\/comments?post=5380"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/zh_hk\/wp-json\/wp\/v2\/posts\/5380\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/zh_hk\/wp-json\/wp\/v2\/media?parent=5380"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/zh_hk\/wp-json\/wp\/v2\/categories?post=5380"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/zh_hk\/wp-json\/wp\/v2\/tags?post=5380"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}