{"id":5363,"date":"2023-05-31T13:47:30","date_gmt":"2023-05-31T05:47:30","guid":{"rendered":"http:\/\/www.dcl-controls.com\/?p=5363"},"modified":"2025-03-23T06:24:14","modified_gmt":"2025-03-23T06:24:14","slug":"setting-switch-actuator","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/zh_cn\/%e6%94%af%e6%8c%81\/%e5%a6%82%e4%bd%95%e5%88%b6%e5%8a%a8%e5%99%a8\/setting-switch-actuator","title":{"rendered":"\u5982\u4f55\u901a\u8fc7\u4f4d\u7f6e\u53d8\u9001\u5668\u914d\u7f6e ON-OFF \u6267\u884c\u673a\u6784\uff1f"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"5363\" class=\"elementor elementor-5363\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-9d3f5d6 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"9d3f5d6\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-cc56700\" data-id=\"cc56700\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-583b268 elementor-widget elementor-widget-heading\" data-id=\"583b268\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"step1\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">1. Mechanical Installation<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be92113 elementor-widget elementor-widget-text-editor\" data-id=\"be92113\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><h4 class=\"\" data-start=\"75\" data-end=\"112\"><strong data-start=\"80\" data-end=\"110\">1. Mechanical Installation<\/strong><\/h4><p class=\"\" data-start=\"113\" data-end=\"288\">Refer to the <strong data-start=\"126\" data-end=\"174\">&#8220;How to Install the Actuator onto the Valve&#8221;<\/strong> section to correctly install the actuator onto the valve and manually operate it to confirm proper functioning.<\/p><p class=\"\" data-start=\"290\" data-end=\"475\">Follow the guidelines in <strong data-start=\"315\" data-end=\"357\">&#8220;How to Set the ON-OFF Electric Valve&#8221;<\/strong> to properly adjust the actuator\u2019s <strong data-start=\"392\" data-end=\"413\">electrical limits<\/strong> (close limit CLS and open limit OLS) and mechanical limits.<\/p><h4 class=\"\" data-start=\"477\" data-end=\"504\"><strong data-start=\"482\" data-end=\"502\">Important Notes:<\/strong><\/h4><ul data-start=\"505\" data-end=\"1061\"><li class=\"\" data-start=\"505\" data-end=\"661\"><p class=\"\" data-start=\"507\" data-end=\"661\">Unless specified otherwise, the actuator\u2019s stroke angle between the fully closed and fully open positions is typically <strong data-start=\"626\" data-end=\"633\">90\u00b0<\/strong> during factory debugging.<\/p><\/li><li class=\"\" data-start=\"662\" data-end=\"755\"><p class=\"\" data-start=\"664\" data-end=\"755\">The output current corresponds to <strong data-start=\"698\" data-end=\"705\">4mA<\/strong> when fully closed and <strong data-start=\"728\" data-end=\"736\">20 \u6beb\u5b89<\/strong> when fully open.<\/p><\/li><li class=\"\" data-start=\"756\" data-end=\"991\"><p class=\"\" data-start=\"758\" data-end=\"991\">\"(\u300a\u4e16\u754c\u4eba\u6743\u5ba3\u8a00\u300b) <strong data-start=\"762\" data-end=\"788\">position potentiometer<\/strong> has been calibrated during the valve matching process, accounting for potential position changes at full open and full close, so users should generally avoid adjusting the potentiometer and its gears.<\/p><\/li><li class=\"\" data-start=\"992\" data-end=\"1061\"><p class=\"\" data-start=\"994\" data-end=\"1061\">Follow the wiring diagram below for correct terminal connections.<\/p><\/li><\/ul><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bff35e6 elementor-widget elementor-widget-heading\" data-id=\"bff35e6\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"step2\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">2. Position Transmitter Panel Explanation<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-198ff2d elementor-widget elementor-widget-image\" data-id=\"198ff2d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"797\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/position-feedback-setting.webp\" class=\"attachment-full size-full wp-image-5365\" alt=\"\u5982\u4f55\u8bbe\u7f6e\u6b66\u6c49\u534e\u6613\u4f4d\u53d1\u578b \u6267\u884c\u5668\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2aab9a9 elementor-widget elementor-widget-text-editor\" data-id=\"2aab9a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li data-start=\"1122\" data-end=\"1154\"><strong data-start=\"1122\" data-end=\"1152\">Adjustable Potentiometers:<\/strong><\/li><li style=\"list-style-type: none;\"><ul data-start=\"1155\" data-end=\"1352\"><li class=\"\" data-start=\"1155\" data-end=\"1352\"><p class=\"\" data-start=\"1157\" data-end=\"1352\"><strong data-start=\"1157\" data-end=\"1176\">\u201cFull Position\u201d<\/strong> \u548c <strong data-start=\"1181\" data-end=\"1200\">\u201cZero Position\u201d<\/strong> potentiometers are used to adjust the corresponding output current to <strong data-start=\"1271\" data-end=\"1279\">20 \u6beb\u5b89<\/strong> \u6216\u8005 <strong data-start=\"1283\" data-end=\"1290\">4mA<\/strong> when the valve is fully open or fully closed, respectively.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"1155\" data-end=\"1352\"><p class=\"\" data-start=\"1157\" data-end=\"1352\"><strong data-start=\"1354\" data-end=\"1369\">Indicators:<\/strong><\/p><\/li><\/ul><ul><li style=\"list-style-type: none;\"><ul data-start=\"1372\" data-end=\"1575\"><li class=\"\" data-start=\"1372\" data-end=\"1461\"><p class=\"\" data-start=\"1374\" data-end=\"1461\"><strong data-start=\"1374\" data-end=\"1387\">L1 (Red):<\/strong> Power indicator, lights up when the position transmitter is powered on.<\/p><\/li><li class=\"\" data-start=\"1462\" data-end=\"1518\"><p class=\"\" data-start=\"1464\" data-end=\"1518\"><strong data-start=\"1464\" data-end=\"1479\">L2 (Green):<\/strong> Lights up when the valve is opening.<\/p><\/li><li class=\"\" data-start=\"1519\" data-end=\"1575\"><p class=\"\" data-start=\"1521\" data-end=\"1575\"><strong data-start=\"1521\" data-end=\"1536\">L3 (Green):<\/strong> Lights up when the valve is closing.<\/p><\/li><\/ul><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8e4bc95 elementor-widget elementor-widget-heading\" data-id=\"8e4bc95\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"step3\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">3. Debugging and Settings<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-671e7a0 elementor-widget elementor-widget-text-editor\" data-id=\"671e7a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><strong data-start=\"1620\" data-end=\"1664\">Potentiometer Mid-Position Determination<\/strong><\/li><li><strong data-start=\"1667\" data-end=\"1698\">Output Current Calibration:<\/strong><br data-start=\"1698\" data-end=\"1701\" \/>The position transmitter is factory-calibrated and typically does not require user adjustment. However, if the output current at full open or full close is not <strong data-start=\"1861\" data-end=\"1869\">20 \u6beb\u5b89<\/strong> \u6216\u8005 <strong data-start=\"1873\" data-end=\"1880\">4mA<\/strong> with an error greater than <strong data-start=\"1908\" data-end=\"1914\">1%<\/strong>, calibration is needed. The following steps can be followed for calibration:<ul><li class=\"\" data-start=\"1993\" data-end=\"2056\"><p class=\"\" data-start=\"1996\" data-end=\"2056\">Connect a <strong data-start=\"2006\" data-end=\"2025\">20mA DC ammeter<\/strong> to the output signal terminal.<\/p><\/li><li class=\"\" data-start=\"2057\" data-end=\"2367\"><p class=\"\" data-start=\"2060\" data-end=\"2367\">Set the valve to <strong data-start=\"2077\" data-end=\"2093\">fully closed<\/strong>, then use a small flathead screwdriver to adjust the <strong data-start=\"2147\" data-end=\"2180\">\u201cZero Position\u201d potentiometer<\/strong> while observing the ammeter. Rotate the potentiometer <strong data-start=\"2235\" data-end=\"2248\">\u987a\u65f6\u9488\u65b9\u5411<\/strong> if the current is greater than <strong data-start=\"2280\" data-end=\"2287\">4mA<\/strong> \u6216\u8005 <strong data-start=\"2291\" data-end=\"2311\">\u9006\u65f6\u9488\u65b9\u5411<\/strong> if it is less, until the ammeter reads <strong data-start=\"2351\" data-end=\"2366\">4mA (\u00b10.02)<\/strong>.<\/p><\/li><li class=\"\" data-start=\"2368\" data-end=\"2621\"><p class=\"\" data-start=\"2371\" data-end=\"2621\">Set the valve to <strong data-start=\"2388\" data-end=\"2402\">fully open<\/strong>, then adjust the <strong data-start=\"2420\" data-end=\"2453\">\u201cFull Position\u201d potentiometer<\/strong> in a similar manner, rotating it <strong data-start=\"2487\" data-end=\"2507\">\u9006\u65f6\u9488\u65b9\u5411<\/strong> if the current is greater than <strong data-start=\"2539\" data-end=\"2547\">20 \u6beb\u5b89<\/strong> \u6216\u8005 <strong data-start=\"2551\" data-end=\"2564\">\u987a\u65f6\u9488\u65b9\u5411<\/strong> if it is less, until the ammeter reads <strong data-start=\"2604\" data-end=\"2620\">20mA (\u00b10.02)<\/strong>.<\/p><\/li><li class=\"\" data-start=\"2622\" data-end=\"2670\"><p class=\"\" data-start=\"2625\" data-end=\"2670\"><strong data-start=\"2625\" data-end=\"2655\">\u8f93\u51fa\u7535\u6d41\u6821\u51c6<\/strong> is complete.<\/p><\/li><\/ul><\/li><\/ul><p class=\"\" data-start=\"2672\" data-end=\"2804\"><strong data-start=\"2672\" data-end=\"2681\">\u7b14\u8bb0\uff1a<\/strong><br data-start=\"2681\" data-end=\"2684\" \/>Always adjust the <strong data-start=\"2702\" data-end=\"2721\">\u201cZero Position\u201d<\/strong> first and then the <strong data-start=\"2741\" data-end=\"2760\">\u201cFull Position\u201d<\/strong> to avoid damaging the position transmitter.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>1. \u673a\u68b0\u5b89\u88c5 \u8bf7\u53c2\u9605\u201c\u5982\u4f55\u5c06\u6267\u884c\u5668\u5b89\u88c5\u5230\u9600\u95e8\u4e0a\u201d\u90e8\u5206\uff0c\u4ee5\u6b63\u786e\u5b89\u88c5\u6267\u884c\u5668\u5230\u9600\u95e8\u4e0a\uff0c\u5e76\u624b\u52a8\u64cd\u4f5c\u4ee5\u786e\u8ba4\u5176\u529f\u80fd\u6b63\u5e38\u3002\u8bf7\u6309\u7167\u201c\u5982\u4f55\u8bbe\u7f6e\u5f00\u5173\u5f0f\u7535\u52a8\u9600\u201d\u4e2d\u7684\u6307\u5357\u6b63\u786e\u8c03\u6574\u6267\u884c\u5668\u7684\u7535\u6c14\u9650\u4f4d\uff08\u5173\u95ed\u9650\u4f4d CLS [\u2026]<\/p>","protected":false},"author":1,"featured_media":10943,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[100],"tags":[53],"class_list":["post-5363","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-how-to-actuator","tag-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/zh_cn\/wp-json\/wp\/v2\/posts\/5363","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/zh_cn\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/zh_cn\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/zh_cn\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/zh_cn\/wp-json\/wp\/v2\/comments?post=5363"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/zh_cn\/wp-json\/wp\/v2\/posts\/5363\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/zh_cn\/wp-json\/wp\/v2\/media\/10943"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/zh_cn\/wp-json\/wp\/v2\/media?parent=5363"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/zh_cn\/wp-json\/wp\/v2\/categories?post=5363"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/zh_cn\/wp-json\/wp\/v2\/tags?post=5363"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}