{"id":9985,"date":"2025-02-10T03:28:44","date_gmt":"2025-02-10T03:28:44","guid":{"rendered":"https:\/\/dclcontrols.com\/?p=9985"},"modified":"2025-03-28T10:36:19","modified_gmt":"2025-03-28T10:36:19","slug":"fsr-um","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/tr_tr\/destek\/um-aktuator\/fsr-um","title":{"rendered":"DCL Akt\u00fcat\u00f6r ve FSR Kullan\u0131m K\u0131lavuzu"},"content":{"rendered":"<p><strong>FSR \u00f6zellikli DCL Akt\u00fcat\u00f6r<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"size-medium alignleft\" src=\"https:\/\/dclcontrols.com\/dam\/actuator\/fsr\/images\/dcl-actuator-with-fsr.webp\" width=\"6912\" height=\"5028\" \/><\/p>\n<h5>\u00c7al\u0131\u015ft\u0131rma Paneli<\/h5>\n<p><img decoding=\"async\" class=\"size-medium alignleft\" src=\"https:\/\/dclcontrols.com\/dam\/actuator\/fsr\/images\/dcl-actuator-fsr-panel.webp\" width=\"1920\" height=\"1964\" \/><\/p>\n<ul>\n<li><strong>Ba\u011flant\u0131<\/strong>\n<p><strong>P1<\/strong>: DC24V G\u00fc\u00e7 +<\/p>\n<p><strong>P3<\/strong>DC24V G\u00fc\u00e7 Kayna\u011f\u0131<\/p>\n<p><strong>P5<\/strong>\uff1a4-20mA Giri\u015f \u2013<\/p>\n<p><strong>P7<\/strong>\uff1a4-20mA Giri\u015f +<\/p>\n<p><strong>P9<\/strong>\uff1a4-20mA \u00c7\u0131k\u0131\u015f \u2013<\/p>\n<p><strong>P11<\/strong>\uff1a4-20mA \u00c7\u0131k\u0131\u015f +<\/p>\n<p><strong>P2<\/strong>: A\u00c7IK\/KAPALI Giri\u015f COM<\/p>\n<p><strong>P4<\/strong>A\u00e7ma\/Kapama Giri\u015fi A\u00e7\u0131k<\/p>\n<p><strong>P6<\/strong>\uff1aA\u00c7MA\/KAPATMA Giri\u015fi Kapatma<\/p>\n<p><strong>P8<\/strong>: A\u00c7IK\/KAPALI \u00c7\u0131k\u0131\u015f COM<\/p>\n<p><strong>P10<\/strong>\uff1aA\u00c7MA\/KAPATMA \u00c7\u0131k\u0131\u015f\u0131 A\u00e7\u0131k<\/p>\n<p><strong>P12<\/strong>\u00c7\u0131k\u0131\u015f\u0131 Kapat\/A\u00e7\/Kapat<\/li>\n<li><strong>D\u00fc\u011fme<\/strong>\n<p><strong>KO<\/strong>Ayar modunda kullan\u0131l\u0131r. Akt\u00fcat\u00f6r\u00fc a\u00e7mak i\u00e7in bu d\u00fc\u011fmeye bas\u0131n.<br \/>\nDurdurmak i\u00e7in b\u0131rak\u0131n. &quot;Ayarla&quot; ve &quot;A\u00e7&quot; d\u00fc\u011fmelerine ayn\u0131 anda bas\u0131n.<br \/>\nTam a\u00e7\u0131k pozisyona ayarlay\u0131n.<\/p>\n<p><strong>KC:<\/strong> Ayar modunda kullan\u0131l\u0131r. Akt\u00fcat\u00f6r\u00fc kapatmak i\u00e7in bu d\u00fc\u011fmeye bas\u0131n.<br \/>\nDurdurmak i\u00e7in b\u0131rak\u0131n. &quot;Ayarla&quot; ve &quot;Kapat&quot; tu\u015flar\u0131na ayn\u0131 anda bas\u0131n.<br \/>\nTamamen kapal\u0131 konuma getirin.<\/p>\n<p><strong>KS:<\/strong> Ayarlar modunda kullan\u0131l\u0131r. Bu d\u00fc\u011fmeyi a\u015fa\u011f\u0131daki kombinasyonlarla kullan\u0131n.<br \/>\nDi\u011ferleri parametreleri yap\u0131land\u0131rabilir.<\/li>\n<li><strong>Anahtar<\/strong>\n<p><strong>SA<\/strong>\u00c7al\u0131\u015fma modunu ayarlay\u0131n (Varsay\u0131lan de\u011fer 1&#039;dir):<\/li>\n<\/ul>\n<blockquote><p><strong>1<\/strong>\u2013Normal Mod\u00fclasyon <strong>2<\/strong>\u2013Ayarlar Modu <strong>3<\/strong>\u2013Ters Mod\u00fclasyon<\/p><\/blockquote>\n<p><strong>SB<\/strong>G\u00fcvenlik Pozisyonunu Ayarlay\u0131n (Varsay\u0131lan de\u011fer 1&#039;dir):<\/p>\n<blockquote><p><strong>1<\/strong>\u2013Tamamen A\u00e7\u0131k Konuma S\u00fcr\u00fc\u015f <strong>2<\/strong>\u2013Pozisyonunuzu koruyun <strong>3<\/strong>\u2013Tamamen S\u00fcr\u00fc\u015fe<br \/>\nKapat<\/p><\/blockquote>\n<ul>\n<li><strong>G\u00f6sterge<\/strong>\n<p><strong>L1<\/strong>Ye\u015fil, G\u00fc\u00e7 G\u00f6stergesi;<\/p>\n<p><strong>L2<\/strong>K\u0131rm\u0131z\u0131, Giri\u015f sinyali hatas\u0131, giri\u015f sinyali a\u015f\u0131ld\u0131\u011f\u0131nda yanar.<br \/>\nmenzil;<\/p>\n<p><strong>L3<\/strong>K\u0131rm\u0131z\u0131, Potansiyometre hatas\u0131, potansiyometre a\u00e7\u0131kken yanar.<br \/>\nAnormal durum veya ba\u011flant\u0131 kablosu kopmu\u015f;<\/p>\n<p><strong>L4<\/strong>K\u0131rm\u0131z\u0131, S\u0131k\u0131\u015fm\u0131\u015f hatas\u0131, akt\u00fcat\u00f6r hareket ettirilemedi\u011finde yanar.<br \/>\na\u00e7mak veya kapatmak.<\/li>\n<\/ul>\n<p><strong>Ayarlar<\/strong><\/p>\n<blockquote><p>SA&#039;y\u0131 2 konumuna getirerek ayar moduna girin. Ard\u0131ndan ayarlar\u0131 yapabilirsiniz.<br \/>\n\u00c7al\u0131\u015fma d\u00f6n\u00fc\u015f aral\u0131\u011f\u0131n\u0131 ayarlay\u0131n, emniyet konumunu ayarlay\u0131n, giri\u015fi kalibre edin.<br \/>\nve \u00e7\u0131k\u0131\u015f sinyali ve benzeri.<\/p><\/blockquote>\n<ul>\n<li><strong>\u00c7al\u0131\u015fma Aral\u0131\u011f\u0131<\/strong>\n<p><strong>Tamamen Kapal\u0131 Konumu Yap\u0131land\u0131r<\/strong>:<\/li>\n<\/ul>\n<ol>\n<li>Vanay\u0131 tamamen kapatmak i\u00e7in A\u00e7ma\/Kapama d\u00fc\u011fmesine bas\u0131n.<br \/>\nkonum.<\/li>\n<li>L2 a\u00e7\u0131lana kadar Ayar d\u00fc\u011fmesini ve ard\u0131ndan Kapat d\u00fc\u011fmesini bas\u0131l\u0131 tutun.<br \/>\nyakla\u015f\u0131k 3-4 saniye sonra, yani tamamen kapal\u0131 pozisyona ge\u00e7ilir.<br \/>\nYap\u0131land\u0131rma tamamland\u0131.<\/li>\n<li>\u015eimdi bu iki d\u00fc\u011fmeyi b\u0131rakabilirsiniz.\n<p><strong>Tamamen A\u00e7\u0131k Pozisyonu Yap\u0131land\u0131r<\/strong>:<\/li>\n<\/ol>\n<p><!-- --><\/p>\n<ol>\n<li>Vanay\u0131 tamamen a\u00e7mak i\u00e7in A\u00e7ma\/Kapama d\u00fc\u011fmesine bas\u0131n.<br \/>\nkonum.<\/li>\n<li>L2 a\u00e7\u0131lana kadar Ayar d\u00fc\u011fmesini ve ard\u0131ndan A\u00e7 d\u00fc\u011fmesini bas\u0131l\u0131 tutun.<br \/>\nyakla\u015f\u0131k 3-4 saniye sonra, yani tamamen a\u00e7\u0131k pozisyona ge\u00e7iyor.<br \/>\nYap\u0131land\u0131rma tamamland\u0131.<\/li>\n<li>\u015eimdi bu iki d\u00fc\u011fmeyi b\u0131rakabilirsiniz.\n<p><em>[Not: Tamamen a\u00e7\u0131k ve kapal\u0131 konum yap\u0131land\u0131r\u0131ld\u0131\u011f\u0131nda]<br \/>\nAyn\u0131 konumda, yap\u0131land\u0131rma ba\u015far\u0131yla tamamlanacakt\u0131r. Ancak<br \/>\nAkt\u00fcat\u00f6r mod\u00fclasyon modunda d\u00f6nmeyecektir.<\/em><\/li>\n<\/ol>\n<ul>\n<li><strong>G\u00fcvenlik Pozisyonunu Ayarlay\u0131n<\/strong><\/li>\n<\/ul>\n<p>G\u00fc\u00e7 kesintisi durumunda, SB ile istedi\u011finiz gibi g\u00fcvenlik konumunu ayarlay\u0131n.<br \/>\nGiri\u015f sinyalinde ar\u0131za vard\u0131 veya sinyalde bir sorun olu\u015fmu\u015ftu.<\/p>\n<ul>\n<li>Akt\u00fcat\u00f6r\u00fcn vanay\u0131 tamamen a\u00e7mas\u0131n\u0131 sa\u011flamak i\u00e7in SB&#039;yi 1 konumuna getirin.<br \/>\nkonum.<\/li>\n<li>Akt\u00fcat\u00f6r\u00fcn mevcut valf konumunu korumas\u0131n\u0131 sa\u011flamak i\u00e7in SB&#039;yi 2 konumuna getirin.<\/li>\n<li>Akt\u00fcat\u00f6r\u00fcn vanay\u0131 tamamen kapatmas\u0131n\u0131 sa\u011flamak i\u00e7in SB&#039;yi 3 konumuna getirin.<br \/>\nkonum.<\/p>\n<p>Bu yap\u0131land\u0131rma b\u00f6l\u00fcm\u00fc normalde gereksizdir, yeniden yap\u0131land\u0131r\u0131n.<br \/>\nE\u011fer ger\u00e7ekten \u00f6nemliyse bunlar.<\/li>\n<\/ul>\n<p><!-- --><\/p>\n<ul>\n<li><strong>4-20mA \u00c7\u0131k\u0131\u015f Kalibrasyonu<\/strong><\/li>\n<\/ul>\n<ol>\n<li>SA&#039;y\u0131 2&#039;ye \u00e7evirin<\/li>\n<li>Ak\u0131m\u0131 izlemek i\u00e7in sinyal \u00e7\u0131k\u0131\u015f\u0131na bir ampermetre ba\u011flay\u0131n.<\/li>\n<li>Ayar d\u00fc\u011fmesini bas\u0131l\u0131 tutun, ard\u0131ndan L2 g\u00f6r\u00fcnene kadar ayn\u0131 anda a\u00e7\u0131p kapat\u0131n.<br \/>\nA\u00e7\u0131ld\u0131, bu da 4mA kalibrasyon moduna girildi\u011fi anlam\u0131na gelir. \u015eimdi siz<br \/>\nBu 3 d\u00fc\u011fmeyi b\u0131rakabilirdi.<\/li>\n<li>4mA&#039;y\u0131 ayarlamak i\u00e7in A\u00e7ma (art\u0131rma) veya Kapatma (azaltma) d\u00fc\u011fmesine bas\u0131n.<\/li>\n<li>L2 kapan\u0131p tekrar a\u00e7\u0131lana kadar ayar d\u00fc\u011fmesini bas\u0131l\u0131 tutun, ard\u0131ndan<br \/>\n20mA kalibrasyonuna girmek i\u00e7in d\u00fc\u011fmeyi b\u0131rak\u0131n.<\/li>\n<li>20mA&#039;y\u0131 ayarlamak i\u00e7in A\u00e7 (art\u0131r) veya Kapat (azalt) d\u00fc\u011fmesine bas\u0131n.<\/li>\n<li>L2 kapan\u0131p tekrar a\u00e7\u0131lana kadar ayar d\u00fc\u011fmesini bas\u0131l\u0131 tutun, ard\u0131ndan<br \/>\nKalibrasyon i\u015flemini tamamlamak i\u00e7in d\u00fc\u011fmeyi b\u0131rak\u0131n.<\/li>\n<\/ol>\n<ul>\n<li><strong>4-20mA Giri\u015f Kalibrasyonu<\/strong><\/li>\n<\/ul>\n<ol>\n<li>SA&#039;y\u0131 2&#039;ye \u00e7evirin<\/li>\n<li>Sinyal giri\u015fine 4-20mA&#039;lik bir ak\u0131m kayna\u011f\u0131 ba\u011flayarak sinyal \u00fcretin.<br \/>\nreferans.<\/li>\n<li>L2 yan\u0131p s\u00f6nmeye ba\u015flayana kadar Set d\u00fc\u011fmesini bas\u0131l\u0131 tutun, ard\u0131ndan Set d\u00fc\u011fmesini b\u0131rak\u0131n. A\u00e7\u0131k konumda tutun.<br \/>\nve L3 yan\u0131p s\u00f6nmeye ba\u015flayana kadar ayn\u0131 anda kapat\u0131n, bu da \u015funu g\u00f6sterir:<br \/>\nKalibrasyon moduna girildi\u011finde, \u015fimdi bu 2 d\u00fc\u011fmeyi b\u0131rak\u0131n.<\/li>\n<li>Giri\u015fe 4mA referans olu\u015fturun, ayar\u0131 tutun ve L4&#039;e kadar kapat\u0131n.<br \/>\nA\u00e7\u0131ld\u0131\u011f\u0131nda, mevcut giri\u015fin kalibre edildi\u011fini g\u00f6sterir.<br \/>\n4mA referans. \u015eimdi 2 d\u00fc\u011fmeyi b\u0131rakabilirsiniz.<\/li>\n<li>Giri\u015fe 20mA referans olu\u015fturun, Ayar d\u00fc\u011fmesini bas\u0131l\u0131 tutun ve L4&#039;e kadar kapat\u0131n.<br \/>\nA\u00e7\u0131ld\u0131\u011f\u0131nda, mevcut giri\u015fin kalibre edildi\u011fini g\u00f6sterir.<br \/>\n20mA referans de\u011feri. \u015eimdi 2 d\u00fc\u011fmeyi b\u0131rakabilirsiniz.<\/li>\n<li>Kalibrasyonun tamamland\u0131\u011f\u0131n\u0131 g\u00f6steren L3 yan\u0131p s\u00f6nmeyi b\u0131rakana kadar Ayarla d\u00fc\u011fmesini bas\u0131l\u0131 tutun.<br \/>\ntamamlanm\u0131\u015f.<\/li>\n<\/ol>\n<p><strong>Kullanmaya Ba\u015flay\u0131n<\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignleft size-medium\" src=\"https:\/\/dclcontrols.com\/dam\/actuator\/fsr\/images\/dcl-actuator-fsr-plug.webp\" width=\"1920\" height=\"2083\" \/><\/p>\n<ul>\n<li><strong>4-20mA ile Mod\u00fclasyon<\/strong><\/li>\n<\/ul>\n<p>Mod\u00fclasyonu ba\u015flatmak i\u00e7in SA&#039;y\u0131 1&#039;e \u00e7evirin.<\/p>\n<ul>\n<li>Akt\u00fcat\u00f6r, vanay\u0131 belirli bir konuma do\u011fru hareket ettirecektir.<br \/>\n4-20mA giri\u015f sinyali atand\u0131.<\/li>\n<li>4-20mA \u00e7\u0131k\u0131\u015f sinyali, valf konumunu ger\u00e7ek zamanl\u0131 olarak verecektir.<br \/>\nzaman.<\/li>\n<li>\u201cA\u00c7MA\/KAPATMA \u00c7\u0131k\u0131\u015f\u0131 A\u00e7\u0131k\u201d oldu\u011funda bir sinyal g\u00f6nderir (COM&#039;a ba\u011flan\u0131r)<br \/>\nVana tamamen a\u00e7\u0131k konuma getirildi.<\/li>\n<li>\u201cA\u00c7MA\/KAPATMA \u00c7\u0131k\u0131\u015f\u0131 Kapatma\u201d i\u015flevi, bir sinyal \u00e7\u0131k\u0131\u015f\u0131 (COM&#039;a ba\u011flanma) sa\u011flad\u0131\u011f\u0131nda devreye girer.<br \/>\nVana tamamen kapal\u0131 konuma getirildi.<\/li>\n<li>Akt\u00fcat\u00f6r, su verildi\u011finde vanay\u0131 emniyet konumuna getirecektir.<br \/>\nG\u00fc\u00e7 kayna\u011f\u0131nda kesinti oldu veya giri\u015f sinyalinde ar\u0131za vard\u0131.<\/li>\n<li>Akt\u00fcat\u00f6r, g\u00fc\u00e7 verildikten sonra mod\u00fclasyon moduna geri d\u00f6necektir.<br \/>\nGiri\u015f sinyali geri kazan\u0131ld\u0131.<\/p>\n<p><em>[Not: Ters i\u015flemi etkinle\u015ftirmek i\u00e7in SA&#039;y\u0131 3&#039;e \u00e7evirebilirsiniz.]<br \/>\nBu durumda, 4mA giri\u015f de\u011feri 20mA&#039;e d\u00f6n\u00fc\u015ft\u00fcr\u00fclecek ve 20mA da...<br \/>\n4mA olarak aktar\u0131ld\u0131. Yani mod\u00fclasyon t\u0131pk\u0131 \u015f\u00f6yle:<br \/>\ntersine \u00e7evrilmi\u015f.]{.alt\u0131 \u00e7izili}<\/em><\/p>\n<p><img decoding=\"async\" src=\"media\/image4.png\" alt=\"1714094198309\" \/>{geni\u015flik=\u201d6,720833333333333in\u00e7\u201d<br \/>\ny\u00fckseklik=\u201d1.070138888888889in\u201d}<\/li>\n<\/ul>\n<p><!-- --><\/p>\n<ul>\n<li><strong>Pasif Dijital Giri\u015fli A\u00e7ma\/Kapama<\/strong><\/li>\n<\/ul>\n<p>Mod\u00fclasyonu ba\u015flatmak i\u00e7in SA&#039;y\u0131 1&#039;e \u00e7evirin.<\/p>\n<ul>\n<li>Akt\u00fcat\u00f6r, vanay\u0131 tamamen a\u00e7\u0131k konuma getirecektir.<br \/>\n&quot;A\u00c7MA\/KAPATMA \u00c7\u0131k\u0131\u015f\u0131 A\u00e7\u0131k&quot; i\u015flevi etkinle\u015fti (COM&#039;a ba\u011fland\u0131).<\/li>\n<li>Akt\u00fcat\u00f6r, vanay\u0131 tamamen kapal\u0131 konuma getirecektir.<br \/>\n\u201cA\u00c7MA\/KAPATMA \u00c7\u0131k\u0131\u015f\u0131 Kapatma\u201d i\u015flemi ba\u015far\u0131l\u0131 oldu (COM&#039;a ba\u011fland\u0131).<\/li>\n<li>\u201cA\u00c7MA\/KAPATMA \u00c7\u0131k\u0131\u015f\u0131 A\u00e7\u0131k\u201d oldu\u011funda bir sinyal g\u00f6nderir (COM&#039;a ba\u011flan\u0131r)<br \/>\nVana tamamen a\u00e7\u0131k konuma getirildi.<\/li>\n<li>\u201cA\u00c7MA\/KAPATMA \u00c7\u0131k\u0131\u015f\u0131 Kapatma\u201d i\u015flevi, bir sinyal \u00e7\u0131k\u0131\u015f\u0131 (COM&#039;a ba\u011flanma) sa\u011flad\u0131\u011f\u0131nda devreye girer.<br \/>\nVana tamamen kapal\u0131 konuma getirildi.<\/li>\n<li>4-20mA \u00e7\u0131k\u0131\u015f sinyali, valf konumunu ger\u00e7ek zamanl\u0131 olarak verecektir.<br \/>\nzaman.<\/li>\n<li>Akt\u00fcat\u00f6r, su verildi\u011finde vanay\u0131 emniyet konumuna getirecektir.<br \/>\nElektrik kesintisi ya\u015fand\u0131.<\/li>\n<li>Besleme g\u00fcc\u00fc kesildikten sonra akt\u00fcat\u00f6r mod\u00fclasyon moduna geri d\u00f6necektir.<br \/>\niyile\u015fti.<\/li>\n<\/ul>\n<p><!-- --><\/p>\n<ul>\n<li><strong>Modbus-RTU\/RS485 ile Mod\u00fclasyon<\/strong><\/li>\n<\/ul>\n<p>Daha fazla bilgi i\u00e7in bizimle ileti\u015fime ge\u00e7in\u2026<\/p>\n<p><strong>Ar\u0131za G\u00f6stergesi<\/strong><\/p>\n<ul>\n<li><strong>L2: Giri\u015f Sinyali Hatas\u0131<\/strong>\n<p>Giri\u015f sinyali kesildi veya aral\u0131\u011f\u0131n d\u0131\u015f\u0131na \u00e7\u0131kt\u0131 (&lt;2,5mA veya &gt; 21,5mA)<\/li>\n<li><strong>L3: Konum \u00d6l\u00e7\u00fcm Hatas\u0131<\/strong>\n<p>Potansiyometre veya ba\u011flant\u0131 kablosu kopmu\u015f.<\/li>\n<li><strong>L4: Tak\u0131lma Hatas\u0131<\/strong>\n<p>Vana s\u0131k\u0131\u015fm\u0131\u015f ve akt\u00fcat\u00f6r vanay\u0131 hareket ettiremiyordu.<br \/>\nBeklenen pozisyon.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>FSR \u00c7al\u0131\u015ft\u0131rma Paneli Ba\u011flant\u0131l\u0131 DCL Akt\u00fcat\u00f6r P1: DC24V G\u00fc\u00e7 + P3: DC24V G\u00fc\u00e7 \u2013 P5: 4-20mA Giri\u015f \u2013 P7: 4-20mA Giri\u015f + P9: 4-20mA \u00c7\u0131k\u0131\u015f \u2013 P11: 4-20mA \u00c7\u0131k\u0131\u015f + P2: A\u00e7ma\/Kapama Giri\u015f COM P4: A\u00e7ma\/Kapama Giri\u015f A\u00e7\u0131k P6: A\u00e7ma\/Kapama Giri\u015f Kapal\u0131 P8: A\u00e7ma\/Kapama \u00c7\u0131k\u0131\u015f COM P10: A\u00e7ma\/Kapama \u00c7\u0131k\u0131\u015f A\u00e7\u0131k P12: A\u00e7ma\/Kapama \u00c7\u0131k\u0131\u015f Kapal\u0131 D\u00fc\u011fme KO: Ayar modunda kullan\u0131l\u0131r. Bu d\u00fc\u011fmeye basarak [\u2026]&#039;\u0131 a\u00e7\u0131n<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[9],"tags":[],"class_list":["post-9985","post","type-post","status-publish","format-standard","hentry","category-um-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/tr_tr\/wp-json\/wp\/v2\/posts\/9985","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/tr_tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/tr_tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/tr_tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/tr_tr\/wp-json\/wp\/v2\/comments?post=9985"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/tr_tr\/wp-json\/wp\/v2\/posts\/9985\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/tr_tr\/wp-json\/wp\/v2\/media?parent=9985"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/tr_tr\/wp-json\/wp\/v2\/categories?post=9985"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/tr_tr\/wp-json\/wp\/v2\/tags?post=9985"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}