{"id":4284,"date":"2023-04-23T20:40:31","date_gmt":"2023-04-23T12:40:31","guid":{"rendered":"http:\/\/www.dcl-controls.com\/?p=4284"},"modified":"2025-03-31T09:27:20","modified_gmt":"2025-03-31T09:27:20","slug":"why-explosion-proof-actuator","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/sl_si\/podpora\/aktuator-2\/zakaj-eksplozijsko-odporen-aktuator","title":{"rendered":"Zakaj nekateri aktuatorji potrebujejo protieksplozijsko za\u0161\u010dito?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"4284\" class=\"elementor elementor-4284\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-ef26768 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"ef26768\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-cb6e5dd\" data-id=\"cb6e5dd\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a724f46 elementor-widget elementor-widget-text-editor\" data-id=\"a724f46\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0<\/p><h2><strong>1. Kaj je eksplozija?<\/strong><\/h2><p>Do eksplozije pride, ko <strong>vnetljive snovi se me\u0161ajo s kisikom<\/strong> in se v\u017egejo pod dolo\u010denimi pogoji. \u010ce <strong>hitrost reakcije presega hitrost zvoka<\/strong>, to ima za posledico <strong>uni\u010dujo\u010d eksplozijski val<\/strong>.<\/p><hr \/><h2><strong>2. Kaj je protieksplozijska za\u0161\u010dita?<\/strong><\/h2><p>Do <strong>prepre\u010diti eksplozije<\/strong>, je treba nadzorovati vsaj enega od treh klju\u010dnih dejavnikov:<\/p><ol><li><p><strong>Vnetljive snovi<\/strong><\/p><\/li><li><p><strong>Kisik<\/strong><\/p><\/li><li><p><strong>Vir v\u017eiga<\/strong><\/p><\/li><\/ol><p>Odkar <strong>vnetljivim snovem in kisiku se pogosto ni mogo\u010de izogniti<\/strong> v industrijskih okoljih, <strong>vir v\u017eiga je treba nadzorovati<\/strong>.<\/p><p>Elektri\u010dna oprema je <strong>potencialni vir v\u017eiga<\/strong> zaradi:<br \/>\u2714 <strong>Povr\u0161insko segrevanje med delovanjem<\/strong><br \/>\u2714 <strong>Elektrostati\u010dna razelektritev<\/strong><br \/>\u2714 <strong>Iskre zaradi elektri\u010dnih tokov<\/strong><\/p><p>Eksplozijsko varna elektri\u010dna oprema je <strong>zasnovano za prepre\u010devanje prekomernih povr\u0161inskih temperatur in elektri\u010dnih isker<\/strong>, s \u010dimer se zagotovi, da <strong>ne postane vir v\u017eiga<\/strong>.<\/p><p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/faq\/actuator\/why-select-a-explosion-proof-actuator\/images\/dcl-explosion-3-factors.webp\" width=\"1033\" height=\"620\" \/><\/p><hr \/><h2><strong>3. Razvrstitev nevarnih okolij<\/strong><\/h2><p>Eksplozijsko varna elektri\u010dna oprema je razvr\u0161\u010dena v dve kategoriji:<\/p><ul><li><p><strong>Kategorija I<\/strong>Oprema za <strong>premogovniki<\/strong><\/p><\/li><li><p><strong>Kategorija II<\/strong>Oprema za <strong>druga eksplozivna plinska okolja<\/strong><\/p><\/li><\/ul><h3><strong>Oprema kategorije II<\/strong><\/h3><ol><li><p><strong>Eksplozivne skupine (na podlagi varnostne re\u017ee in v\u017eignega toka)<\/strong><\/p><ul><li><p><strong>Medinstitucionalni sporazum<\/strong><\/p><\/li><li><p><strong>IIB<\/strong> (lahko se uporablja v pogojih IIA)<\/p><\/li><li><p><strong>IIC<\/strong> (lahko se uporablja v pogojih IIA in IIB)<\/p><\/li><\/ul><\/li><li><p><strong>Temperaturne skupine (na podlagi najvi\u0161je temperature povr\u0161ine)<\/strong><\/p><ul><li><p><strong>T1 (450 \u00b0C)<\/strong><\/p><\/li><li><p><strong>T2 (300 \u00b0C)<\/strong><\/p><\/li><li><p><strong>T3 (200 \u00b0C)<\/strong><\/p><\/li><li><p><strong>T4 (135 \u00b0C)<\/strong><\/p><\/li><li><p><strong>T5 (100 \u00b0C)<\/strong><\/p><\/li><li><p><strong>T6 (85 \u00b0C)<\/strong><\/p><\/li><\/ul><\/li><\/ol><p>Ve\u010d kot <strong>90% eksplozivnih plinov<\/strong> pasti pod <strong>Skupine IIA, IIB<\/strong> in <strong>Temperaturne klasifikacije T1\u2013T4<\/strong>.<\/p><p><img decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/faq\/actuator\/why-select-a-explosion-proof-actuator\/images\/dcl-explosion-level.webp\" width=\"1323\" height=\"400\" \/><\/p><hr \/><h2><strong>4. Kako se dose\u017ee protieksplozijska za\u0161\u010dita?<\/strong><\/h2><p>Ve\u010d metod zagotavlja, da je elektri\u010dna oprema <strong>varno za eksplozivna okolja<\/strong>, kot je opredeljeno z <strong>GB3836, IEC60079, EN50014<\/strong> standardi.<\/p><p><img decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/elementor\/thumbs\/dcl-explosion-no-fire-q66rupb0ie91afmk9gkhl6y0ri81l2banhzo5pk1fo.webp\" width=\"500\" height=\"314\" \/><\/p><h3><strong>Eksplozijsko varna (Exd) zasnova<\/strong><\/h3><p>Eksplozijsko varni aktuatorji DCL so izdelani v skladu z:<br \/>\u2714 <strong>GB3836.1-2010, GB3836.2-2010<\/strong><br \/>\u2714 <strong>IEC 60079-0, IEC 60079-1, IEC 60079-31<\/strong><br \/>\u2714 <strong>ISO\/IEC 80079-36, ISO\/IEC 80079-37<\/strong><\/p><h4><strong>Na\u010dela ognjevarnega (Exd) na\u010drtovanja<\/strong><\/h4><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/faq\/actuator\/why-select-a-explosion-proof-actuator\/images\/dcl-explosion-proof.webp\" width=\"1163\" height=\"661\" \/><\/p><p>\u2714 <strong>V notranjosti naprave lahko pride do eksplozije<\/strong>, vendar ohi\u0161je prepre\u010duje v\u017eig zunanjega okolja.<br \/>\u2714 <strong>Ognjevarni spoji<\/strong> so zasnovani s pravilnimi <strong>vrzel in dol\u017eina<\/strong> za zadr\u017eevanje notranjih eksplozij.<br \/>\u2714 <strong>Mo\u010dna ohi\u0161ja<\/strong> vzdr\u017eati <strong>visok notranji tlak<\/strong> brez zloma.<\/p><h3><strong>Eksplozijsko varne komponente DCL<\/strong><\/h3><p>\u2714 <strong>Motorni prostor<\/strong><br \/>\u2714 <strong>Predal za elektri\u010dne komponente<\/strong><br \/>\u2714 <strong>Predal za o\u017ei\u010denje<\/strong><\/p><hr \/><h2><strong>5. Certifikat DCL za eksplozijsko varne aktuatorje<\/strong><\/h2><h3><strong>Stopnja eksplozijske za\u0161\u010dite: Exd IIC T4 Gb<\/strong><\/h3><p>\u2714 <strong>Biv\u0161i<\/strong> \u2013 Oznaka protieksplozijske za\u0161\u010dite<br \/>\u2714 <strong>d<\/strong> \u2013 Negorljiva vrsta (\u00bbExd\u00ab)<br \/>\u2714 <strong>Drugi<\/strong> \u2013 Aplikacije, ki niso povezane z rudarjenjem<br \/>\u2714 <strong>C<\/strong> \u2013 Eksplozijska skupina (vi\u0161je varnostne zahteve)<br \/>\u2714 <strong>T4<\/strong> \u2013 Najvi\u0161ja temperatura povr\u0161ine <strong>135 \u00b0C<\/strong><br \/>\u2714 <strong>VB<\/strong> \u2013 Raven za\u0161\u010dite opreme<\/p><hr \/><h3><strong>Zaklju\u010dek<\/strong><\/h3><p>Eksplozijsko varni aktuatorji so bistveni pri <strong>nevarna okolja<\/strong> prepre\u010diti <strong>v\u017eig eksplozivnih plinov<\/strong>DCL-ji <strong>Pogoni z oznako Exd IIC T4 Gb<\/strong> zagotovite varnost z:<br \/>\u2714 <strong>Vsebuje notranje eksplozije<\/strong><br \/>\u2714 <strong>Prepre\u010devanje iskrenja in prekomerne vro\u010dine<\/strong><br \/>\u2714 <strong>Odpornost na visok tlak brez razpok<\/strong><\/p><p>Ti oblikovni ukrepi omogo\u010dajo <strong>Zanesljivi in varni DCL aktuatorji<\/strong> za <strong>industrijske aplikacije v eksplozivnih atmosferah<\/strong>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>\u00a0 1. Kaj je eksplozija? Do eksplozije pride, ko se vnetljive snovi zme\u0161ajo s kisikom in se pod dolo\u010denimi pogoji vnamejo. \u010ce hitrost reakcije prese\u017ee hitrost zvoka, nastane uni\u010dujo\u010d eksplozijski val. 2. Kaj je eksplozijska za\u0161\u010dita? Da bi prepre\u010dili eksplozije, je treba nadzorovati vsaj enega od treh klju\u010dnih dejavnikov: [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[91],"tags":[53,66,39],"class_list":["post-4284","post","type-post","status-publish","format-standard","hentry","category-an-actuator","tag-actuator","tag-explosion-proof-actuator","tag-faq"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/sl_si\/wp-json\/wp\/v2\/posts\/4284","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/sl_si\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/sl_si\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/sl_si\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/sl_si\/wp-json\/wp\/v2\/comments?post=4284"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/sl_si\/wp-json\/wp\/v2\/posts\/4284\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/sl_si\/wp-json\/wp\/v2\/media?parent=4284"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/sl_si\/wp-json\/wp\/v2\/categories?post=4284"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/sl_si\/wp-json\/wp\/v2\/tags?post=4284"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}