{"id":6393,"date":"2023-08-31T19:23:28","date_gmt":"2023-08-31T11:23:28","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6393"},"modified":"2025-03-31T07:02:40","modified_gmt":"2025-03-31T07:02:40","slug":"en15714-2-actuator-duty-classification","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/sk_sk\/podpora\/pohon-ts\/klasifikacia-vykonu-pohonu-podla-en15714-2","title":{"rendered":"Klasifik\u00e1cia ovl\u00e1dania elektrick\u00fdch aktu\u00e1torov (prev\u00e1dzka) pod\u013ea EN15714-2"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6393\" class=\"elementor elementor-6393\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-c4425ee elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"c4425ee\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-592bf2f\" data-id=\"592bf2f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5ac9aa3 elementor-widget elementor-widget-image\" data-id=\"5ac9aa3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"646\" height=\"914\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/08\/en15714-2-en.webp\" class=\"attachment-full size-full wp-image-6403\" alt=\"\u7535\u52a8\u6267\u884c\u5668\u63a7\u5236\u65b9\u5f0f (povinnos\u0165)\u7684\u5206\u7c7b\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2d2988c elementor-widget elementor-widget-text-editor\" data-id=\"2d2988c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2><strong>Klasifik\u00e1cia kontroln\u00fdch povinnost\u00ed:<\/strong><\/h2><ul><li><h4><strong>Trieda A: Typ ON-OFF (zapnut\u00e9\/vypnut\u00e9)<\/strong><\/h4><\/li><\/ul><ul><li style=\"list-style-type: none;\"><ul><li><p><strong>Funkcia<\/strong>Pohon mus\u00ed poh\u00e1\u0148a\u0165 ventil po\u010das cel\u00e9ho jeho zdvihu z \u00faplne otvoren\u00e9ho do \u00faplne zatvoren\u00e9ho stavu (a naopak).<\/p><\/li><li><p><strong>Typick\u00e9 pou\u017eitie<\/strong>Aplik\u00e1cie, kde s\u00fa ventily bu\u010f \u00faplne otvoren\u00e9 alebo \u00faplne zatvoren\u00e9.<\/p><\/li><\/ul><\/li><li><h4><strong>Trieda B: Typ s jemn\u00fdm doladen\u00edm\/nastaven\u00edm polohy<\/strong><\/h4><ul><li><p><strong style=\"font-size: 16px;\">Funkcia<\/strong><span style=\"font-size: 16px;\">Pohon ob\u010das presunie ventil do \u013eubovo\u013enej polohy (\u00faplne otvoren\u00fd, stredn\u00fd alebo \u00faplne zatvoren\u00fd).<\/span><\/p><\/li><li><p><strong style=\"font-size: 16px;\">Typick\u00e9 pou\u017eitie<\/strong><span style=\"font-size: 16px;\">Aplik\u00e1cie vy\u017eaduj\u00face ob\u010dasn\u00e9 nastavenie, ale nie nepretr\u017eit\u00fd pohyb.<\/span><\/p><\/li><\/ul><\/li><li><h4><strong>Trieda C: Modula\u010dn\u00fd typ<\/strong><\/h4><ul><li><p><strong>Funkcia<\/strong>Pohon \u010dasto pohybuje ventilom medzi \u00faplne otvorenou a \u00faplne zatvorenou polohou.<\/p><\/li><li><p><strong>Typick\u00e9 pou\u017eitie<\/strong>Aplik\u00e1cie, ktor\u00e9 vy\u017eaduj\u00fa nepretr\u017eit\u00fa a \u010dast\u00fa modul\u00e1ciu polohy ventilu.<\/p><\/li><\/ul><\/li><li><h4><strong>Trieda D: Typ s kontinu\u00e1lnou modul\u00e1ciou<\/strong><\/h4><ul><li><p><strong>Funkcia<\/strong>Pohon plynule pohybuje ventilom do \u013eubovo\u013enej polohy medzi \u00faplne otvoren\u00fdm a \u00faplne zatvoren\u00fdm.<\/p><\/li><li><p><strong>Typick\u00e9 pou\u017eitie<\/strong>Aplik\u00e1cie s nepretr\u017eit\u00fdm alebo ve\u013emi \u010dast\u00fdm nastavovan\u00edm.<\/p><\/li><\/ul><\/li><\/ul><hr \/><h2><strong>Po\u017eiadavky na \u017eivotn\u00fd cyklus aktu\u00e1tora:<\/strong><\/h2><p>Kon\u0161trukcia pohonu mus\u00ed sp\u013a\u0148a\u0165 stanoven\u00e9 normy prev\u00e1dzkovej \u017eivotnosti. V pr\u00edpade modula\u010dn\u00fdch a kontinu\u00e1lne modula\u010dn\u00fdch pohonov je ich \u017eivotnos\u0165 zalo\u017een\u00e1 na nepretr\u017eit\u00fdch rozbehoch v r\u00e1mci 30% ich zdvihu.<\/p><h4><strong>Sk\u00fa\u0161ka \u017eivotnosti oto\u010dn\u00fdch aktu\u00e1torov:<\/strong><\/h4><table><thead><tr><th>Menovit\u00fd rozsah kr\u00fatiaceho momentu (Nm)<\/th><th>Trieda A\/B (ZAP-VYP)<\/th><th>Trieda C (modula\u010dn\u00e1)<\/th><th>Trieda D (kontinu\u00e1lna modul\u00e1cia)<\/th><\/tr><\/thead><tbody><tr><td>&lt;= 125<\/td><td>10 000 cyklov<\/td><td>1 800 000 cyklov<\/td><td>10 000 000 cyklov<\/td><\/tr><tr><td>126-1000<\/td><td>10 000 cyklov<\/td><td>1 200 000 cyklov<\/td><td>10 000 000 cyklov<\/td><\/tr><tr><td>1001-4000<\/td><td>5 000 cyklov<\/td><td>500 000 cyklov<\/td><td>5 000 000 cyklov<\/td><\/tr><tr><td>4001-32000<\/td><td>5 000 cyklov<\/td><td>250 000 cyklov<\/td><td>Bude dohodnut\u00e9<\/td><\/tr><tr><td>&gt; 32000<\/td><td>1 000 cyklov<\/td><td>Bude dohodnut\u00e9<\/td><td>Bude dohodnut\u00e9<\/td><\/tr><\/tbody><\/table><ul><li><p><strong>Prev\u00e1dzkov\u00e9 cykly<\/strong>Cyklus zah\u0155\u0148a dva smery 90\u00b0 zdvihu (otvorenie 90\u00b0 + zatvorenie 90\u00b0), na z\u00e1klade priemern\u00e9ho za\u0165a\u017eenia menovit\u00fdm kr\u00fatiacim momentom najmenej 30%, s menovit\u00fdm kr\u00fatiacim momentom najmenej 5% na ka\u017edom konci zdvihu.<\/p><\/li><li><p><strong>\u0160tartovacie cykly<\/strong>Jedno spustenie zah\u0155\u0148a posunutie aktu\u00e1tora o minim\u00e1lne 11 TP3T jeho zdvihu s menovit\u00fdm kr\u00fatiacim momentom minim\u00e1lne 301 TP3T.<\/p><\/li><\/ul><hr \/><h4><strong>Testovanie \u017eivotnosti viacot\u00e1\u010dkov\u00fdch pohonov:<\/strong><\/h4><table><thead><tr><th>Menovit\u00fd rozsah kr\u00fatiaceho momentu (Nm)<\/th><th>Maxim\u00e1lny \u0165ah (kN)<\/th><th>Trieda A\/B (ZAP-VYP)<\/th><th>Trieda C (modula\u010dn\u00e1)<\/th><th>Trieda D (kontinu\u00e1lna modul\u00e1cia)<\/th><\/tr><\/thead><tbody><tr><td>&lt;= 100<\/td><td>&lt;= 40<\/td><td>10 000 cyklov<\/td><td>1 800 000 cyklov<\/td><td>10 000 000 cyklov<\/td><\/tr><tr><td>101-700<\/td><td>&lt;= 150<\/td><td>10 000 cyklov<\/td><td>1 200 000 cyklov<\/td><td>10 000 000 cyklov<\/td><\/tr><tr><td>701-2500<\/td><td>&lt;= 325<\/td><td>5 000 cyklov<\/td><td>500 000 cyklov<\/td><td>5 000 000 cyklov<\/td><\/tr><tr><td>2501-10000<\/td><td>&lt;= 1100<\/td><td>5 000 cyklov<\/td><td>250 000 cyklov<\/td><td>Bude dohodnut\u00e9<\/td><\/tr><tr><td>&gt; 10 000<\/td><td>&gt; 1100<\/td><td>1 000 cyklov<\/td><td>Bude dohodnut\u00e9<\/td><td>Bude dohodnut\u00e9<\/td><\/tr><\/tbody><\/table><hr \/><h4><strong>Testovanie \u017eivotnosti line\u00e1rnych aktu\u00e1torov:<\/strong><\/h4><table><thead><tr><th>Menovit\u00fd rozsah \u0165ahu (kN)<\/th><th>Trieda A\/B (ZAP-VYP)<\/th><th>Trieda C (modula\u010dn\u00e1)<\/th><th>Trieda D (kontinu\u00e1lna modul\u00e1cia)<\/th><\/tr><\/thead><tbody><tr><td>&lt;= 20<\/td><td>10 000 cyklov<\/td><td>1 800 000 cyklov<\/td><td>10 000 000 cyklov<\/td><\/tr><tr><td>21-70<\/td><td>10 000 cyklov<\/td><td>1 200 000 cyklov<\/td><td>10 000 000 cyklov<\/td><\/tr><tr><td>71-150<\/td><td>5 000 cyklov<\/td><td>500 000 cyklov<\/td><td>5 000 000 cyklov<\/td><\/tr><tr><td>151-325<\/td><td>2 500 cyklov<\/td><td>250 000 cyklov<\/td><td>Bude dohodnut\u00e9<\/td><\/tr><tr><td>&gt; 325<\/td><td>1 000 cyklov<\/td><td>Bude dohodnut\u00e9<\/td><td>Bude dohodnut\u00e9<\/td><\/tr><\/tbody><\/table><hr \/><h2><strong>Po\u017eiadavky na frekvenciu \u00faprav (za hodinu):<\/strong><\/h2><h4><strong>\u010ciasto\u010dne oto\u010dn\u00e9 pohony:<\/strong><\/h4><table><thead><tr><th>Menovit\u00fd rozsah kr\u00fatiaceho momentu (Nm)<\/th><th>Trieda A (ZAP-VYP)<\/th><th>Trieda B (ZAP-VYP)<\/th><th>Trieda C (modula\u010dn\u00e1)<\/th><th>Trieda D (kontinu\u00e1lna modul\u00e1cia)<\/th><\/tr><\/thead><tbody><tr><td>&lt;= 125<\/td><td>15 cyklov\/hod.<\/td><td>120 \u0161tartov\/hod.<\/td><td>1 200 \u0161tartov\/hod.<\/td><td>3 600 \u0161tartov\/hod.<\/td><\/tr><tr><td>126-1000<\/td><td>10 cyklov\/hod.<\/td><td>60 \u0161tartov\/hod.<\/td><td>600 \u0161tartov\/hod.<\/td><td>1 800 \u0161tartov\/hod.<\/td><\/tr><tr><td>1001-4000<\/td><td>5 cyklov\/hod.<\/td><td>30 \u0161tartov\/hod.<\/td><td>300 \u0161tartov\/hod.<\/td><td>600 \u0161tartov\/hod.<\/td><\/tr><tr><td>4001-32000<\/td><td>5 cyklov\/hod.<\/td><td>15 \u0161tartov\/hod.<\/td><td>60 \u0161tartov\/hod.<\/td><td>NA<\/td><\/tr><tr><td>&gt; 32000<\/td><td>5 cyklov\/hod.<\/td><td>5 \u0161tartov\/hod.<\/td><td>30 \u0161tartov\/hod.<\/td><td>NA<\/td><\/tr><\/tbody><\/table><hr \/><h4><strong>Viacot\u00e1\u010dkov\u00e9 pohony:<\/strong><\/h4><table><thead><tr><th>Menovit\u00fd rozsah kr\u00fatiaceho momentu (Nm)<\/th><th>Trieda A (ZAP-VYP)<\/th><th>Trieda B (ZAP-VYP)<\/th><th>Trieda C (modula\u010dn\u00e1)<\/th><th>Trieda D (kontinu\u00e1lna modul\u00e1cia)<\/th><\/tr><\/thead><tbody><tr><td>&lt;= 100<\/td><td>15 min\u00fat\/hod.<\/td><td>30 \u0161tartov\/hod.<\/td><td>1 200 \u0161tartov\/hod.<\/td><td>3 600 \u0161tartov\/hod.<\/td><\/tr><tr><td>101-700<\/td><td>15 min\u00fat\/hod.<\/td><td>20 \u0161tartov\/hod.<\/td><td>600 \u0161tartov\/hod.<\/td><td>1 800 \u0161tartov\/hod.<\/td><\/tr><tr><td>701-2500<\/td><td>15 min\u00fat\/hod.<\/td><td>15 \u0161tartov\/hod.<\/td><td>300 \u0161tartov\/hod.<\/td><td>600 \u0161tartov\/hod.<\/td><\/tr><tr><td>2501-10000<\/td><td>15 min\u00fat\/hod.<\/td><td>10 \u0161tartov\/hod.<\/td><td>60 \u0161tartov\/hod.<\/td><td>NA<\/td><\/tr><tr><td>&gt; 10 000<\/td><td>15 min\u00fat\/hod.<\/td><td>5 \u0161tartov\/hod.<\/td><td>30 \u0161tartov\/hod.<\/td><td>NA<\/td><\/tr><\/tbody><\/table><hr \/><h4><strong>Line\u00e1rne aktu\u00e1tory:<\/strong><\/h4><table><thead><tr><th>Menovit\u00fd rozsah \u0165ahu (kN)<\/th><th>Trieda A (ZAP-VYP)<\/th><th>Trieda B (ZAP-VYP)<\/th><th>Trieda C (modula\u010dn\u00e1)<\/th><th>Trieda D (kontinu\u00e1lna modul\u00e1cia)<\/th><\/tr><\/thead><tbody><tr><td>&lt;= 20<\/td><td>15 cyklov\/hod.<\/td><td>30 \u0161tartov\/hod.<\/td><td>1 200 \u0161tartov\/hod.<\/td><td>3 600 \u0161tartov\/hod.<\/td><\/tr><tr><td>21-70<\/td><td>10 cyklov\/hod.<\/td><td>15 \u0161tartov\/hod.<\/td><td>600 \u0161tartov\/hod.<\/td><td>1 800 \u0161tartov\/hod.<\/td><\/tr><tr><td>&gt; 70<\/td><td>5 cyklov\/hod.<\/td><td>5 \u0161tartov\/hod.<\/td><td>30 \u0161tartov\/hod.<\/td><td>Bude ozn\u00e1men\u00e9<\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-192baa1 elementor-widget elementor-widget-text-editor\" data-id=\"192baa1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Relevantn\u00e9 normy:<\/p><p><em>EN15714-1<\/em><\/p><p><em>EN 12570, Priemyseln\u00e9 ventily \u2013 met\u00f3da ur\u010denia ve\u013ekosti ovl\u00e1dacieho prvku<\/em><br \/><em>EN 60529\uff0c\u5916\u58f3\u9632\u62a4\u7b49\u7ea7\uff08IP\u4ee3\u7801\uff09\uff09(IEC 60529:1989\uff09<\/em><br \/><em>EN ISO 5210:1996\uff0c\u5de5\u4e1a\u9600\u95e8\u2014\u2014\u591a\u56de\u8f6c\u9600\u95e8\u6267\u884c\u673a\u6784\u9644\u4ef6\uff081SO 5210:1991\uff09<\/em><br \/><em>EN ISO 5211\uff0c\u5de5\u4e1a\u9600\u95e8-\u90e8\u5206\u56de\u8f6c\u9600\u95e8\u6267\u884c\u673a\u6784\u9644\u4ef6\uff08ISO 5211-2001\uff09<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Klasifik\u00e1cia ovl\u00e1dacej funkcie: Trieda A: Typ ZAP-VYP (Zap\/Vyp) Funkcia: Pohon mus\u00ed ovl\u00e1da\u0165 ventil po\u010das cel\u00e9ho jeho zdvihu z \u00faplne otvoren\u00e9ho do \u00faplne zatvoren\u00e9ho stavu (a naopak). Typick\u00e9 pou\u017eitie: Aplik\u00e1cie, kde s\u00fa ventily bu\u010f \u00faplne otvoren\u00e9, alebo \u00faplne zatvoren\u00e9. Trieda B: Typ jemn\u00e9ho ladenia\/nastavenia polohy Funkcia: Pohon ob\u010das pos\u00fava ventil do [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[3],"tags":[53,66,57,52,55,65],"class_list":["post-6393","post","type-post","status-publish","format-standard","hentry","category-ts-actuator","tag-actuator","tag-explosion-proof-actuator","tag-general-actuator","tag-fast-move-actuator","tag-tech-ref","tag-very-small-actuator-tag"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/sk_sk\/wp-json\/wp\/v2\/posts\/6393","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/sk_sk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/sk_sk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/sk_sk\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/sk_sk\/wp-json\/wp\/v2\/comments?post=6393"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/sk_sk\/wp-json\/wp\/v2\/posts\/6393\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/sk_sk\/wp-json\/wp\/v2\/media?parent=6393"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/sk_sk\/wp-json\/wp\/v2\/categories?post=6393"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/sk_sk\/wp-json\/wp\/v2\/tags?post=6393"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}