{"id":6537,"date":"2023-09-18T18:49:43","date_gmt":"2023-09-18T10:49:43","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6537"},"modified":"2025-03-28T10:33:47","modified_gmt":"2025-03-28T10:33:47","slug":"gb-t-3369-1-2008-iec-60381-1-1982","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/ro_ro\/sprijin\/actuator-ts\/gb-t-3369-1-2008-iec-60381-1-1982","title":{"rendered":"Standarde de semnal de tensiune pentru actuatoare electrice \u2013 GB\/T 3369.2\u20142008\/IEC 60381-2:1978"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6537\" class=\"elementor elementor-6537\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4ad6800 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"4ad6800\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-448b26a\" data-id=\"448b26a\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-2d2988c elementor-widget elementor-widget-text-editor\" data-id=\"2d2988c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h4 class=\"\" data-start=\"243\" data-end=\"339\">Standarde aplicabile pentru semnalele de tensiune ale actuatoarelor electrice (1-5V, 2-10V, 0-5V, 0-10V):<\/h4><p class=\"\" data-start=\"340\" data-end=\"485\"><strong data-start=\"340\" data-end=\"457\">Semnale analogice pentru sisteme de control al proceselor \u2013 Partea 2: Semnale de tensiune continu\u0103 (GB\/T 3369.2\u20142008\/IEC 60381-2:1978)<\/strong><br data-start=\"457\" data-end=\"460\" \/><em data-start=\"460\" data-end=\"483\">IEC 60381-2-1978, IDT<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6d95a9b elementor-widget elementor-widget-image\" data-id=\"6d95a9b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"678\" height=\"1028\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/09\/gbt3369-1-2008-IEC-60381-1-1982.png\" class=\"attachment-full size-full wp-image-6539\" alt=\"GB\/T 3369.1\u20142008\/IEC 60381-1:1982 - \u8fc7\u7a0b\u63a7\u5236\u7cfb\u7edf\u7528\u6a21\u62df\u4fe1\u53f7-\u7b2c1\u90e8\u5206\uff1a\u76f4\u6d41\u7535\u6d41\u4fe1\u53f7\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-314b810 elementor-widget elementor-widget-heading\" data-id=\"314b810\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Prefa\u0163\u0103<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-303746d elementor-widget elementor-widget-text-editor\" data-id=\"303746d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"501\" data-end=\"618\">GB\/T 3369.2\u20142008\/IEC 60381-2:1978 \u2013 <em data-start=\"537\" data-end=\"616\">Semnale analogice pentru sisteme de control al proceselor \u2013 Partea 2: Semnale de tensiune continu\u0103<\/em><\/p><p class=\"\" data-start=\"620\" data-end=\"681\">Standardul GB\/T 3369 este alc\u0103tuit din urm\u0103toarele dou\u0103 p\u0103r\u021bi:<\/p><ul data-start=\"682\" data-end=\"764\"><li class=\"\" data-start=\"682\" data-end=\"725\"><p class=\"\" data-start=\"684\" data-end=\"725\"><strong data-start=\"684\" data-end=\"695\">Partea 1:<\/strong> Semnale de curent continuu (CC)<\/p><\/li><li class=\"\" data-start=\"726\" data-end=\"764\"><p class=\"\" data-start=\"728\" data-end=\"764\"><strong data-start=\"728\" data-end=\"739\">Partea a 2-a:<\/strong> Semnale de tensiune continu\u0103<\/p><\/li><\/ul><p class=\"\" data-start=\"766\" data-end=\"817\">Acest document reprezint\u0103 <strong data-start=\"791\" data-end=\"801\">Partea a 2-a<\/strong> din GB\/T 3369.<\/p><p class=\"\" data-start=\"819\" data-end=\"957\">Adopt\u0103 pe deplin <strong data-start=\"835\" data-end=\"855\">IEC 60381-2:1978<\/strong>, <em data-start=\"857\" data-end=\"955\">Semnale analogice pentru sisteme de control al proceselor \u2013 Partea 2: Semnale de tensiune continu\u0103 (versiunea \u00een limba englez\u0103).<\/em><\/p><p class=\"\" data-start=\"959\" data-end=\"1401\">Conform <strong data-start=\"972\" data-end=\"989\">GB\/T 1.1\u20142000<\/strong> (<em data-start=\"991\" data-end=\"1066\">Ghid de standardizare \u2013 Partea 1: Structura standard \u0219i regulile de scriere<\/em>), urm\u0103toarele modific\u0103ri editoriale au fost aduse standardului IEC 60381-2:1978:<br data-start=\"1137\" data-end=\"1140\" \/>a) Termenul <strong data-start=\"1152\" data-end=\"1171\">\u201eacest standard\u201d<\/strong> a fost schimbat \u00een <strong data-start=\"1187\" data-end=\"1203\">\u201epartea asta.\u201d<\/strong><br data-start=\"1203\" data-end=\"1206\" \/>b) Prefa\u021ba la IEC 60381-2:1978 a fost eliminat\u0103.<br data-start=\"1253\" data-end=\"1256\" \/>c) Orice referire la <strong data-start=\"1276\" data-end=\"1291\">\u201eIEC 60381\u201d<\/strong> a fost \u00eenlocuit cu <strong data-start=\"1310\" data-end=\"1326\">\u201eGB\/T 3369.\u201d<\/strong><br data-start=\"1326\" data-end=\"1329\" \/>d) Virgula zecimal\u0103 <strong data-start=\"1350\" data-end=\"1357\">&#8220;,&#8221;<\/strong> a fost \u00eenlocuit cu o virgul\u0103 zecimal\u0103 <strong data-start=\"1392\" data-end=\"1399\">&#8220;.&#8221;<\/strong><\/p><p class=\"\" data-start=\"1403\" data-end=\"1511\">Aceast\u0103 parte \u00eenlocuie\u0219te <strong data-start=\"1422\" data-end=\"1440\">GB\/T 3370\u20141989<\/strong> (<em data-start=\"1442\" data-end=\"1507\">Semnale analogice de tensiune continu\u0103 pentru instrumente de automatizare industrial\u0103<\/em>).<\/p><h3 data-start=\"1513\" data-end=\"1559\">\u00a0<\/h3><h3 data-start=\"1513\" data-end=\"1559\">Principalele modific\u0103ri comparativ cu GB\/T 3370-1989:<\/h3><ul data-start=\"1560\" data-end=\"2575\"><li class=\"\" data-start=\"1560\" data-end=\"1756\"><p class=\"\" data-start=\"1562\" data-end=\"1756\">Numele standard a fost schimbat din <strong data-start=\"1597\" data-end=\"1666\">\u201eSemnale analogice de tensiune continu\u0103 pentru instrumente de automatizare industrial\u0103\u201d<\/strong> la <strong data-start=\"1670\" data-end=\"1754\">\u201eSemnale analogice pentru sisteme de control al proceselor \u2013 Partea 2: Semnale de tensiune continu\u0103.\u201d<\/strong><\/p><\/li><li class=\"\" data-start=\"1757\" data-end=\"1824\"><p class=\"\" data-start=\"1759\" data-end=\"1824\">Termenul <strong data-start=\"1768\" data-end=\"1787\">\u201eacest standard\u201d<\/strong> a fost \u00eenlocuit cu <strong data-start=\"1806\" data-end=\"1822\">\u201epartea asta.\u201d<\/strong><\/p><\/li><li class=\"\" data-start=\"1825\" data-end=\"2119\"><p class=\"\" data-start=\"1827\" data-end=\"1854\"><strong data-start=\"1827\" data-end=\"1852\">Domeniu de aplicare:<\/strong><\/p><ul data-start=\"1857\" data-end=\"2119\"><li class=\"\" data-start=\"1857\" data-end=\"1967\"><p class=\"\" data-start=\"1859\" data-end=\"1967\"><strong data-start=\"1859\" data-end=\"1877\">GB\/T 3370\u20131989<\/strong> se baza pe <strong data-start=\"1891\" data-end=\"1911\">IEC 60381-2:1979<\/strong> \u0219i aplicat la <strong data-start=\"1927\" data-end=\"1965\">instrumente de automatizare industrial\u0103.<\/strong><\/p><\/li><li class=\"\" data-start=\"1970\" data-end=\"2119\"><p class=\"\" data-start=\"1972\" data-end=\"2119\"><strong data-start=\"1972\" data-end=\"1992\">GB\/T 3369.2\u20142008<\/strong> este un <strong data-start=\"1999\" data-end=\"2022\">adop\u021bie echivalent\u0103<\/strong> de <strong data-start=\"2026\" data-end=\"2046\">IEC 60381-2:1979<\/strong> \u0219i se aplic\u0103 la <strong data-start=\"2062\" data-end=\"2117\">sisteme de m\u0103surare \u0219i control al proceselor industriale.<\/strong><\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"2120\" data-end=\"2205\"><p class=\"\" data-start=\"2122\" data-end=\"2205\">Termenul <strong data-start=\"2131\" data-end=\"2170\">\u201einstrumente de automatizare industrial\u0103\u201d<\/strong> a fost schimbat \u00een <strong data-start=\"2186\" data-end=\"2203\">\u201ecomponente\u201d.<\/strong><\/p><\/li><li class=\"\" data-start=\"2206\" data-end=\"2501\"><p class=\"\" data-start=\"2208\" data-end=\"2328\">The <strong data-start=\"2212\" data-end=\"2232\">\u201econ\u021binut Ripple\u201d<\/strong> \u015fi <strong data-start=\"2237\" data-end=\"2262\">\u201ecomponent\u0103 de curent alternativ de ie\u0219ire\u201d<\/strong> defini\u021biile au fost eliminate, \u00een timp ce au fost ad\u0103ugate noi defini\u021bii pentru:<\/p><ul data-start=\"2331\" data-end=\"2501\"><li class=\"\" data-start=\"2331\" data-end=\"2392\"><p class=\"\" data-start=\"2333\" data-end=\"2392\"><strong data-start=\"2333\" data-end=\"2390\">\u201eValoarea m\u0103surat\u0103 a unui semnal analogic de tensiune continu\u0103\u201d<\/strong><\/p><\/li><li class=\"\" data-start=\"2395\" data-end=\"2419\"><p class=\"\" data-start=\"2397\" data-end=\"2419\"><strong data-start=\"2397\" data-end=\"2417\">\u201eImpedan\u021ba de sarcin\u0103\u201d<\/strong><\/p><\/li><li class=\"\" data-start=\"2422\" data-end=\"2446\"><p class=\"\" data-start=\"2424\" data-end=\"2446\"><strong data-start=\"2424\" data-end=\"2444\">\u201eCon\u021binut Ripple\u201d<\/strong><\/p><\/li><li class=\"\" data-start=\"2449\" data-end=\"2472\"><p class=\"\" data-start=\"2451\" data-end=\"2472\"><strong data-start=\"2451\" data-end=\"2470\">\u201eSemnal comun\u201d<\/strong><\/p><\/li><li class=\"\" data-start=\"2475\" data-end=\"2501\"><p class=\"\" data-start=\"2477\" data-end=\"2501\"><strong data-start=\"2477\" data-end=\"2499\">\u201eIzolarea semnalului\u201d<\/strong><\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"2502\" data-end=\"2575\"><p class=\"\" data-start=\"2504\" data-end=\"2575\">Tabelul 1 include acum intervalele de semnal <strong data-start=\"2539\" data-end=\"2552\">0 p\u00e2n\u0103 la +10V<\/strong> \u015fi <strong data-start=\"2557\" data-end=\"2573\">-10 p\u00e2n\u0103 la +10V.<\/strong><\/p><\/li><\/ul><h3 data-start=\"2577\" data-end=\"2609\">\u00a0<\/h3><h3 data-start=\"2577\" data-end=\"2609\">Organiza\u021bii responsabile:<\/h3><ul data-start=\"2610\" data-end=\"3176\"><li class=\"\" data-start=\"2610\" data-end=\"2666\"><p class=\"\" data-start=\"2612\" data-end=\"2666\"><strong data-start=\"2612\" data-end=\"2628\">Propus de:<\/strong> Federa\u021bia Industriei Ma\u0219inilor din China<\/p><\/li><li class=\"\" data-start=\"2667\" data-end=\"2799\"><p class=\"\" data-start=\"2669\" data-end=\"2799\"><strong data-start=\"2669\" data-end=\"2684\">Gestionat de:<\/strong> Comitetul Tehnic Na\u021bional pentru Standardizarea M\u0103sur\u0103rii \u0219i Controlului Proceselor Industriale (Subcomitetul al Doilea)<\/p><\/li><li class=\"\" data-start=\"2800\" data-end=\"2882\"><p class=\"\" data-start=\"2802\" data-end=\"2882\"><strong data-start=\"2802\" data-end=\"2828\">Institu\u021bii de redactare:<\/strong> Universitatea Southwest, China Silian Instrument Group<\/p><\/li><li class=\"\" data-start=\"2883\" data-end=\"3052\"><p class=\"\" data-start=\"2885\" data-end=\"2918\"><strong data-start=\"2885\" data-end=\"2916\">Institu\u021bii participante:<\/strong><\/p><ul data-start=\"2921\" data-end=\"3052\"><li class=\"\" data-start=\"2921\" data-end=\"2992\"><p class=\"\" data-start=\"2923\" data-end=\"2992\">Institutul de Cercetare Economic\u0103 \u0219i Instrumente pentru Industria Ma\u0219inilor din China<\/p><\/li><li class=\"\" data-start=\"2995\" data-end=\"3052\"><p class=\"\" data-start=\"2997\" data-end=\"3052\">Institutul de Automatizare a Industriei Ma\u0219inilor din Beijing<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"3053\" data-end=\"3125\"><p class=\"\" data-start=\"3055\" data-end=\"3125\"><strong data-start=\"3055\" data-end=\"3083\">Personal principal de redactare:<\/strong> Liu Feng, Pan Dongbo, Zhang Yu, Liu Jin<\/p><\/li><li class=\"\" data-start=\"3126\" data-end=\"3176\"><p class=\"\" data-start=\"3128\" data-end=\"3176\"><strong data-start=\"3128\" data-end=\"3145\">Contribuitori:<\/strong> Feng Xiaosheng, Xie Bingbing<\/p><\/li><\/ul><p class=\"\" data-start=\"3178\" data-end=\"3218\">Aceast\u0103 parte \u00eenlocuie\u0219te standardele anterioare:<\/p><ul data-start=\"3219\" data-end=\"3262\"><li class=\"\" data-start=\"3219\" data-end=\"3239\"><p class=\"\" data-start=\"3221\" data-end=\"3239\"><strong data-start=\"3221\" data-end=\"3237\">GB 3370\u20141982<\/strong><\/p><\/li><li class=\"\" data-start=\"3240\" data-end=\"3262\"><p class=\"\" data-start=\"3242\" data-end=\"3262\"><strong data-start=\"3242\" data-end=\"3260\">GB\/T 3370\u20141989<\/strong><\/p><\/li><\/ul><h2 data-start=\"3269\" data-end=\"3355\">\u00a0<\/h2><h2 data-start=\"3269\" data-end=\"3355\"><strong data-start=\"3272\" data-end=\"3353\">Semnale analogice pentru sisteme de control al proceselor \u2013 Partea 2: Semnale de tensiune continu\u0103<\/strong><\/h2><h3 data-start=\"3357\" data-end=\"3375\">\u00a0<\/h3><h3 data-start=\"3357\" data-end=\"3375\"><strong data-start=\"3361\" data-end=\"3373\">1. Domeniu de aplicare<\/strong><\/h3><p class=\"\" data-start=\"3376\" data-end=\"3553\">Aceast\u0103 parte se aplic\u0103 <strong data-start=\"3397\" data-end=\"3432\">semnale analogice de tensiune continu\u0103<\/strong> utilizat pentru transmiterea informa\u021biilor \u00eentre componentele sistemului <strong data-start=\"3496\" data-end=\"3551\">sisteme de m\u0103surare \u0219i control al proceselor industriale.<\/strong><\/p><p class=\"\" data-start=\"3555\" data-end=\"3733\">Spre deosebire de <strong data-start=\"3566\" data-end=\"3601\">semnale analogice de curent continuu<\/strong> specificat \u00een <strong data-start=\"3615\" data-end=\"3635\">GB\/T 3369.1-2008<\/strong>, <strong data-start=\"3637\" data-end=\"3672\">semnale analogice de tensiune continu\u0103<\/strong> ar trebui <strong data-start=\"3680\" data-end=\"3687\">nu<\/strong> fi folosit pentru <strong data-start=\"3700\" data-end=\"3731\">transmitere la distan\u021b\u0103 lung\u0103.<\/strong><\/p><p class=\"\" data-start=\"3735\" data-end=\"3821\">Aceast\u0103 parte <strong data-start=\"3745\" data-end=\"3757\">nu<\/strong> se aplic\u0103 semnalelor utilizate \u00een \u00eentregime <strong data-start=\"3789\" data-end=\"3819\">\u00een cadrul unei singure componente.<\/strong><\/p><h3 data-start=\"3828\" data-end=\"3862\">\u00a0<\/h3><h3 class=\"\" data-start=\"3828\" data-end=\"3862\"><strong data-start=\"3832\" data-end=\"3860\">2. Termeni \u0219i defini\u021bii<\/strong><\/h3><h4 class=\"\" data-start=\"3864\" data-end=\"3943\"><strong data-start=\"3869\" data-end=\"3941\">2.1 Componentele sistemelor de m\u0103surare \u0219i control al proceselor industriale<\/strong><\/h4><p class=\"\" data-start=\"3944\" data-end=\"4123\">Unit\u0103\u021bi func\u021bionale \u0219i dispozitive combinate integrate utilizate pentru <strong data-start=\"4004\" data-end=\"4121\">converti, transmite sau procesa valori m\u0103surate, m\u0103rimi de control, variabile controlate \u0219i variabile de referin\u021b\u0103.<\/strong><\/p><h4 class=\"\" data-start=\"4125\" data-end=\"4170\"><strong data-start=\"4130\" data-end=\"4168\">2.2 Semnal analogic de tensiune continu\u0103<\/strong><\/h4><p class=\"\" data-start=\"4171\" data-end=\"4316\">O <strong data-start=\"4173\" data-end=\"4194\">Semnal de tensiune continu\u0103<\/strong> care variaz\u0103 continuu \u00een func\u021bie de una sau mai multe m\u0103rimi fizice, utilizat\u0103 pentru <strong data-start=\"4271\" data-end=\"4314\">transmiterea sau prelucrarea informa\u021biilor.<\/strong><\/p><h4 class=\"\" data-start=\"4318\" data-end=\"4384\"><strong data-start=\"4323\" data-end=\"4382\">2.3 Valoarea m\u0103surat\u0103 a unui semnal analogic de tensiune continu\u0103<\/strong><\/h4><p class=\"\" data-start=\"4385\" data-end=\"4476\">The <strong data-start=\"4389\" data-end=\"4406\">valoare medie<\/strong> unui semnal analogic de tensiune continu\u0103 <strong data-start=\"4444\" data-end=\"4474\">pe o durat\u0103 specificat\u0103.<\/strong><\/p><h4 class=\"\" data-start=\"4478\" data-end=\"4504\"><strong data-start=\"4483\" data-end=\"4502\">2.4 Limita inferioar\u0103<\/strong><\/h4><p class=\"\" data-start=\"4505\" data-end=\"4575\">The <strong data-start=\"4509\" data-end=\"4520\">minim<\/strong> valoarea tensiunii semnalului analogic de tensiune continu\u0103.<\/p><h4 class=\"\" data-start=\"4577\" data-end=\"4603\"><strong data-start=\"4582\" data-end=\"4601\">2.5 Limita superioar\u0103<\/strong><\/h4><p class=\"\" data-start=\"4604\" data-end=\"4674\">The <strong data-start=\"4608\" data-end=\"4619\">maxim<\/strong> valoarea tensiunii semnalului analogic de tensiune continu\u0103.<\/p><h4 class=\"\" data-start=\"4676\" data-end=\"4733\"><strong data-start=\"4681\" data-end=\"4731\">2.6 Intervalul unui semnal analogic de tensiune continu\u0103<\/strong><\/h4><p class=\"\" data-start=\"4734\" data-end=\"4819\">Intervalul definit de <strong data-start=\"4759\" data-end=\"4774\">limit\u0103 inferioar\u0103<\/strong> \u015fi <strong data-start=\"4779\" data-end=\"4794\">limit\u0103 superioar\u0103<\/strong> a tensiunii semnalului.<\/p><h4 class=\"\" data-start=\"4821\" data-end=\"4850\"><strong data-start=\"4826\" data-end=\"4848\">2.7 Impedan\u021ba sarcinii<\/strong><\/h4><p class=\"\" data-start=\"4851\" data-end=\"4904\">Impedan\u021ba total\u0103 a tuturor <strong data-start=\"4878\" data-end=\"4902\">receptoare conectate.<\/strong><\/p><h4 class=\"\" data-start=\"4906\" data-end=\"4935\"><strong data-start=\"4911\" data-end=\"4933\">2.8 Con\u021binut Ripple<\/strong><\/h4><p class=\"\" data-start=\"4936\" data-end=\"5059\">Raportul dintre <strong data-start=\"4953\" data-end=\"4995\">valoarea v\u00e2rf-v\u00e2rf a componentei de curent alternativ<\/strong> c\u0103tre <strong data-start=\"5003\" data-end=\"5018\">limit\u0103 superioar\u0103<\/strong> a semnalului analogic de tensiune continu\u0103.<\/p><h4 class=\"\" data-start=\"5061\" data-end=\"5089\"><strong data-start=\"5066\" data-end=\"5087\">2.9 Semnal comun<\/strong><\/h4><p class=\"\" data-start=\"5090\" data-end=\"5192\">O conexiune electric\u0103 comun\u0103 partajat\u0103 de mai multe circuite de semnal, care pot fi sau nu legate la mas\u0103.<\/p><h4 class=\"\" data-start=\"5194\" data-end=\"5226\"><strong data-start=\"5199\" data-end=\"5224\">2.10 Izolarea semnalului<\/strong><\/h4><p class=\"\" data-start=\"5227\" data-end=\"5339\">Absen\u021ba <strong data-start=\"5242\" data-end=\"5268\">conexiuni electrice<\/strong> \u00eentre <strong data-start=\"5281\" data-end=\"5299\">circuit de semnal<\/strong> \u0219i alte circuite sau <strong data-start=\"5326\" data-end=\"5337\">sol.<\/strong><\/p><h3 data-start=\"5346\" data-end=\"5381\">\u00a0<\/h3><h3 class=\"\" data-start=\"5346\" data-end=\"5381\"><strong data-start=\"5350\" data-end=\"5379\">3. Cerin\u021be tehnice<\/strong><\/h3><h4 class=\"\" data-start=\"5383\" data-end=\"5438\"><strong data-start=\"5388\" data-end=\"5436\">3.1 Gama semnalelor analogice de tensiune continu\u0103<\/strong><\/h4><p class=\"\" data-start=\"5439\" data-end=\"5493\">Tabelul 1 prezint\u0103 intervalele standard ale semnalelor de tensiune.<\/p><div class=\"overflow-x-auto contain-inline-size\"><table data-start=\"5495\" data-end=\"5720\"><thead data-start=\"5495\" data-end=\"5534\"><tr data-start=\"5495\" data-end=\"5534\"><th data-start=\"5495\" data-end=\"5513\">Limit\u0103 inferioar\u0103 (V)<\/th><th data-start=\"5513\" data-end=\"5534\">Limita superioar\u0103 (V)<\/th><\/tr><\/thead><tbody data-start=\"5573\" data-end=\"5720\"><tr data-start=\"5573\" data-end=\"5609\"><td>+1<\/td><td>+5<\/td><\/tr><tr data-start=\"5610\" data-end=\"5646\"><td>0<\/td><td>+5<\/td><\/tr><tr data-start=\"5647\" data-end=\"5683\"><td>0<\/td><td>+10<\/td><\/tr><tr data-start=\"5684\" data-end=\"5720\"><td>-10<\/td><td>+10<\/td><\/tr><\/tbody><\/table><\/div><p class=\"\" data-start=\"5722\" data-end=\"5734\"><strong data-start=\"5722\" data-end=\"5732\">Note:<\/strong><\/p><ul data-start=\"5735\" data-end=\"5938\"><li class=\"\" data-start=\"5735\" data-end=\"5845\"><p class=\"\" data-start=\"5737\" data-end=\"5845\">Semnale de tensiune <strong data-start=\"5753\" data-end=\"5771\">poate fi derivat<\/strong> din semnale analogice de curent continuu specificate \u00een <strong data-start=\"5822\" data-end=\"5843\">GB\/T 3369.1\u20142008.<\/strong><\/p><\/li><li class=\"\" data-start=\"5846\" data-end=\"5938\"><p class=\"\" data-start=\"5848\" data-end=\"5938\">Semnale de tensiune <strong data-start=\"5864\" data-end=\"5871\">poate<\/strong> reprezint\u0103 m\u0103rimi fizice folosind <strong data-start=\"5908\" data-end=\"5936\">caracteristici bipolare.<\/strong><\/p><\/li><\/ul><h4 class=\"\" data-start=\"5945\" data-end=\"5974\"><strong data-start=\"5950\" data-end=\"5972\">3.2 Con\u021binut Ripple<\/strong><\/h4><p class=\"\" data-start=\"5975\" data-end=\"6057\">C\u00e2nd se utilizeaz\u0103 <strong data-start=\"5986\" data-end=\"6019\">surse de alimentare CC f\u0103r\u0103 ondula\u021bii<\/strong>, trebuie specificate urm\u0103toarele:<\/p><ul data-start=\"6058\" data-end=\"6274\"><li class=\"\" data-start=\"6058\" data-end=\"6124\"><p class=\"\" data-start=\"6060\" data-end=\"6124\"><strong data-start=\"6060\" data-end=\"6092\">Con\u021binutul \u0219i frecven\u021ba Ripple<\/strong> \u00een cadrul componentelor sistemului.<\/p><\/li><li class=\"\" data-start=\"6125\" data-end=\"6192\"><p class=\"\" data-start=\"6127\" data-end=\"6192\"><strong data-start=\"6127\" data-end=\"6150\">Zgomot \u0219i frecven\u021b\u0103<\/strong> generate \u00een cadrul componentelor sistemului.<\/p><\/li><li class=\"\" data-start=\"6193\" data-end=\"6274\"><p class=\"\" data-start=\"6195\" data-end=\"6274\">Con\u021binutul Ripple cauzat de <strong data-start=\"6220\" data-end=\"6246\">Ondula\u021bia aliment\u0103rii cu curent continuu<\/strong> ar trebui, de asemenea, specificate.<\/p><\/li><\/ul><h4 class=\"\" data-start=\"6281\" data-end=\"6314\"><strong data-start=\"6286\" data-end=\"6312\">3.3 Linie comun\u0103 de semnal<\/strong><\/h4><ul data-start=\"6315\" data-end=\"6705\"><li class=\"\" data-start=\"6315\" data-end=\"6511\"><p class=\"\" data-start=\"6317\" data-end=\"6511\">Pentru <strong data-start=\"6321\" data-end=\"6341\">semnale unipolare<\/strong>, cel\/cea\/cei\/cele <strong data-start=\"6347\" data-end=\"6368\">terminal negativ<\/strong> serve\u0219te ca linie comun\u0103 de semnal. Dac\u0103 este conectat la un <strong data-start=\"6421\" data-end=\"6440\">Surs\u0103 de alimentare de curent continuu<\/strong>, ar trebui s\u0103 se conecteze la <strong data-start=\"6467\" data-end=\"6488\">terminal negativ<\/strong> al sursei de alimentare.<\/p><\/li><li class=\"\" data-start=\"6512\" data-end=\"6705\"><p class=\"\" data-start=\"6514\" data-end=\"6705\">Pentru <strong data-start=\"6518\" data-end=\"6537\">semnale bipolare<\/strong>, cel\/cea\/cei\/cele <strong data-start=\"6543\" data-end=\"6563\">terminal neutru<\/strong> serve\u0219te ca linie comun\u0103 de semnal. Dac\u0103 este conectat la un <strong data-start=\"6616\" data-end=\"6635\">Surs\u0103 de alimentare de curent continuu<\/strong>, ar trebui s\u0103 se conecteze la <strong data-start=\"6662\" data-end=\"6682\">terminal neutru<\/strong> al sursei de alimentare.<\/p><\/li><\/ul><h4 class=\"\" data-start=\"6712\" data-end=\"6736\"><strong data-start=\"6717\" data-end=\"6734\">3.4 \u00cemp\u0103m\u00e2ntare<\/strong><\/h4><ul data-start=\"6737\" data-end=\"7033\"><li class=\"\" data-start=\"6737\" data-end=\"6888\"><p class=\"\" data-start=\"6739\" data-end=\"6888\">Pentru <strong data-start=\"6743\" data-end=\"6763\">semnale unipolare<\/strong>, dac\u0103 componenta este <strong data-start=\"6785\" data-end=\"6797\">pedepsit<\/strong>, cel\/cea\/cei\/cele <strong data-start=\"6803\" data-end=\"6824\">terminal negativ<\/strong> a semnalului \u0219i\/sau a sursei de alimentare CC trebuie, de asemenea, conectate la mas\u0103.<\/p><\/li><li class=\"\" data-start=\"6889\" data-end=\"7033\"><p class=\"\" data-start=\"6891\" data-end=\"7033\">Pentru <strong data-start=\"6895\" data-end=\"6914\">semnale bipolare<\/strong>, dac\u0103 componenta este <strong data-start=\"6936\" data-end=\"6948\">pedepsit<\/strong>, cel\/cea\/cei\/cele <strong data-start=\"6954\" data-end=\"6974\">terminal neutru<\/strong> a semnalului \u0219i\/sau a sursei de alimentare CC trebuie s\u0103 fie legate la p\u0103m\u00e2nt.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Standarde aplicabile pentru semnalele de tensiune ale actuatoarelor electrice (1-5V, 2-10V, 0-5V, 0-10V): Semnale analogice pentru sisteme de control al proceselor \u2013 Partea 2: Semnale de tensiune continu\u0103 (GB\/T 3369.2\u20142008\/IEC 60381-2:1978)IEC 60381-2-1978, IDT Prefa\u021b\u0103 GB\/T 3369.2\u20142008\/IEC 60381-2:1978 \u2013 Semnale analogice pentru sisteme de control al proceselor \u2013 Partea 2: Semnale de tensiune continu\u0103 Standardul GB\/T 3369 este alc\u0103tuit din urm\u0103toarele dou\u0103 p\u0103r\u021bi: [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[3],"tags":[49],"class_list":["post-6537","post","type-post","status-publish","format-standard","hentry","category-ts-actuator","tag-input-signal"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/posts\/6537","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/comments?post=6537"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/posts\/6537\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/media?parent=6537"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/categories?post=6537"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/tags?post=6537"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}