{"id":6422,"date":"2023-09-13T21:13:49","date_gmt":"2023-09-13T13:13:49","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6422"},"modified":"2025-03-31T07:17:39","modified_gmt":"2025-03-31T07:17:39","slug":"actuator-communication","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/ro_ro\/sprijin\/ta-acutator\/comunicarea-actuatorului","title":{"rendered":"Autobuze utilizate \u00een mod obi\u0219nuit pentru actuatoare electrice"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6422\" class=\"elementor elementor-6422\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-c4425ee elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"c4425ee\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-592bf2f\" data-id=\"592bf2f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-2d2988c elementor-widget elementor-widget-text-editor\" data-id=\"2d2988c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un num\u0103r tot mai mare de sisteme de control industrial implementeaz\u0103 magistrale de c\u00e2mp pentru a controla mai mul\u021bi senzori \u0219i actuatoare. Fiind un actuator cheie \u00een procesele de control al fluidelor, actuatoarele electrice sunt utilizate \u00een mod obi\u0219nuit \u00een aplica\u021biile industriale. Cele mai frecvent utilizate sisteme de magistral\u0103 pentru actuatoarele electrice includ Modbus, CAN, Profibus, DeviceNet, Foundation Fieldbus, HART \u0219i Ethernet.<\/p><h3>Sisteme magistrale comune pentru actuatoare electrice:<\/h3><ul><li><p><strong>Modbus<\/strong><\/p><\/li><li><p><strong>POATE<\/strong><\/p><\/li><li><p><strong>Profibus<\/strong><\/p><\/li><li><p><strong>DeviceNet<\/strong><\/p><\/li><li><p><strong>Foundation Fieldbus (FF)<\/strong><\/p><\/li><li><p><strong>CERB<\/strong><\/p><\/li><li><p><strong>Ethernet<\/strong><\/p><\/li><\/ul><hr \/><h3><strong>Modbus<\/strong><\/h3><p>Comparativ cu alte tehnologii de magistral\u0103 de c\u00e2mp, Modbus este simplu, dar multifunc\u021bional. Ofer\u0103 toate serviciile necesare pentru automatizarea fabricii, cum ar fi schimbul de informa\u021bii binare simple, valori analogice, parametri ai dispozitivului sau date de diagnosticare.<\/p><p>Pentru automatizarea fabricilor \u0219i dispozitive precum Profibus, se utilizeaz\u0103 de obicei un strat fizic simplu \u0219i robust, RS-485. Pe baza acestui strat fizic, Modbus accept\u0103 diverse formate de telegrame, cum ar fi Modbus RTU sau Modbus ASCII. Utilizarea versiunii Modbus TCP\/IP bazat\u0103 pe Ethernet permite integrarea vertical\u0103 cu sistemele de automatizare gazd\u0103.<\/p><p><strong>Caracteristici:<\/strong><\/p><ul><li><p>Protocol simplu<\/p><\/li><li><p>Potrivit pentru medii simple de automatizare industrial\u0103<br \/><a href=\"http:\/\/www.modbus.org\/\" target=\"_blank\" rel=\"noopener\">www.modbus.org<\/a><\/p><\/li><\/ul><hr \/><h3><strong>CAN (Re\u021bea de zon\u0103 a controlerului)<\/strong><\/h3><p>CAN este un protocol de comunica\u021bie serial\u0103 standardizat de ISO \u0219i a fost propus pentru prima dat\u0103 de Bosch \u00een 1986. Este utilizat pe scar\u0103 larg\u0103 \u00een electronica auto, automatiz\u0103ri industriale, industria marin\u0103, dispozitive medicale \u0219i echipamente industriale.<\/p><p>CAN are dou\u0103 protocoale standardizate: ISO11898 pentru comunica\u021bii de mare vitez\u0103 (125 Kbps\u20131 Mbps) \u0219i ISO11519-2 pentru comunica\u021bii de mic\u0103 vitez\u0103 (sub 125 Kbps). CAN este extrem de fiabil \u0219i accept\u0103 control multi-master, viteze mari de transmisie \u0219i ad\u0103ug\u0103ri flexibile de noduri.<\/p><p><strong>Caracteristici:<\/strong><\/p><ul><li><p>Control multi-master<\/p><\/li><li><p>Vitez\u0103 mare de transmisie<\/p><\/li><li><p>Ad\u0103ugarea flexibil\u0103 de noduri<\/p><\/li><\/ul><hr \/><h3><strong>Profibus<\/strong><\/h3><p>PROFIBUS este un standard interna\u021bional, deschis \u0219i independent de dispozitiv pentru magistral\u0103 de c\u00e2mp. Viteza sa de transmisie variaz\u0103 de la 9,6 kbaud la 12 Mbaud. PROFIBUS este utilizat pe scar\u0103 larg\u0103 \u00een automatizarea produc\u021biei, automatizarea industriei proceselor \u0219i automatizarea cl\u0103dirilor.<\/p><p>PROFIBUS este alc\u0103tuit din trei p\u0103r\u021bi compatibile:<\/p><ul><li><p><strong>PROFIBUS-DP<\/strong> (Periferie descentralizat\u0103) pentru comunicarea \u00eentre sistemele de control la nivel de dispozitiv \u0219i I\/O distribuite.<\/p><\/li><li><p><strong>PROFIBUS-PA<\/strong> (Automatizare de Procese) pentru conectarea senzorilor \u0219i actuatoarelor pe aceea\u0219i magistral\u0103, cu standarde de siguran\u021b\u0103 intrinsec\u0103.<\/p><\/li><li><p><strong>PROFIBUS-FMS<\/strong> (Specifica\u021bia mesajelor Fieldbus) pentru monitorizare la nivel de atelier cu re\u021bea multi-master \u00een timp real.<\/p><\/li><\/ul><p><strong>Caracteristici:<\/strong><\/p><ul><li><p>Arhitectur\u0103 deschis\u0103<\/p><\/li><li><p>Fiabilitate<\/p><\/li><li><p>Flexibilitate<\/p><\/li><li><p>Performan\u021b\u0103 \u00een timp real<\/p><\/li><\/ul><hr \/><h3><strong>DeviceNet<\/strong><\/h3><p>DeviceNet este o magistral\u0103 de comunica\u021bii cu cost redus care conecteaz\u0103 dispozitive industriale precum \u00eentrerup\u0103toare de limit\u0103, senzori, valve, demaroare de motor \u0219i multe altele, elimin\u00e2nd costurile mari de cablare. \u00cembun\u0103t\u0103\u021be\u0219te comunicarea dintre dispozitive \u0219i ofer\u0103 func\u021bii semnificative de diagnosticare la nivel de dispozitiv, care sunt dificil de realizat cu interfe\u021bele I\/O tradi\u021bionale.<\/p><p>DeviceNet se bazeaz\u0103 pe protocolul CAN, oferind transmisie de date \u00een timp real. Accept\u0103 comunicare punct-la-punct, multi-master sau master\/slave \u0219i poate conecta p\u00e2n\u0103 la 64 de noduri. Vitezele sale de transmisie sunt de 125kb\/s, 250kb\/s \u0219i 500kb\/s.<\/p><p><strong>Caracteristici:<\/strong><\/p><ul><li><p>Comunicare cu costuri reduse<\/p><\/li><li><p>Solu\u021bie simpl\u0103 de re\u021bea<\/p><\/li><li><p>Standard deschis pentru hardware \u0219i software<\/p><\/li><li><p>Capacit\u0103\u021bi de diagnosticare<\/p><\/li><\/ul><hr \/><h3><strong>Foundation Fieldbus (FF)<\/strong><\/h3><p>Foundation Fieldbus este special conceput pentru automatizarea proceselor, cu protocolul FF H1 pentru transmisie la nivel de c\u00e2mp. FF accept\u0103 diverse topologii \u0219i permite comunicarea direct\u0103 \u00eentre dispozitive atunci c\u00e2nd este echipat cu un planificator activ de leg\u0103tur\u0103 (LAS).<\/p><p><strong>Caracteristici:<\/strong><\/p><ul><li><p>Flexibilitate \u00een topologie<\/p><\/li><li><p>Suport\u0103 control digital descentralizat<\/p><\/li><li><p>Comunicare direct\u0103 \u00eentre dispozitivele de teren<\/p><\/li><li><p>Bazat pe blocuri func\u021bionale standardizate pentru intrare\/ie\u0219ire<\/p><\/li><\/ul><p><a href=\"http:\/\/www.fieldcommgroup.org\/\" target=\"_blank\" rel=\"noopener\">www.fieldcommgroup.org<\/a><\/p><hr \/><h3><strong>HART (Traductor de la distan\u021b\u0103 adresabil pe autostrad\u0103)<\/strong><\/h3><p>HART utilizeaz\u0103 semnalul analogic standard de 4-20 mA pentru transmiterea at\u00e2t a datelor analogice, c\u00e2t \u0219i a celor digitale. Comunicarea HART moduleaz\u0103 semnalul suplimentar peste semnalul analogic de 4-20 mA, permi\u021b\u00e2nd transmiterea simultan\u0103 a semnalelor digitale \u0219i analogice.<\/p><p>Sus\u021bine principiul master\/slave \u0219i este adesea utilizat \u00een comunicarea punct-la-punct.<\/p><p><strong>Caracteristici:<\/strong><\/p><ul><li><p>Utilizeaz\u0103 infrastructura existent\u0103 de 4-20 mA<\/p><\/li><li><p>Comunicare digital\u0103 pentru parametri suplimentari \u0219i diagnosticare<\/p><\/li><li><p>Acceptat de o gam\u0103 larg\u0103 de dispozitive<br \/><a href=\"http:\/\/www.fieldcommgroup.org\/\" target=\"_blank\" rel=\"noopener\">www.fieldcommgroup.org<\/a><\/p><\/li><\/ul><hr \/><h3><strong>Ethernet<\/strong><\/h3><p>Ast\u0103zi, Ethernet-ul clasic a devenit standardul principal de re\u021bea de date \u00een mediile de birou. \u201eEthernet industrial\u201d se refer\u0103 la Ethernet-ul \u00eembun\u0103t\u0103\u021bit care poate fi utilizat \u00een mediile de automatizare industrial\u0103.<\/p><p><strong>Caracteristici:<\/strong><\/p><ul><li><p>Transmisie de date \u00een timp real \u0219i IT prin medii comune<\/p><\/li><li><p>Num\u0103r practic nelimitat de participan\u021bi \u0219i extindere a re\u021belei<\/p><\/li><li><p>Topologie scalabil\u0103 \u0219i flexibil\u0103<\/p><\/li><li><p>Transfer de date de mare vitez\u0103, chiar \u0219i pentru volume mari de date<\/p><\/li><li><p>Integrare u\u0219oar\u0103 cu servere de re\u021bea \u0219i interfe\u021be IoT (de exemplu, OPC UA)<\/p><\/li><\/ul><p>Protocoalele Ethernet industriale precum Profinet, Ethernet\/IP \u0219i Modbus TCP sunt integrate direct \u00een sistemele DCS \u0219i asigur\u0103 o comunicare fiabil\u0103 \u0219i acces facil la dispozitivele de teren.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Un num\u0103r tot mai mare de sisteme de control industrial utilizeaz\u0103 autobuze de teren pentru a controla mai mul\u021bi senzori \u0219i actuatori. Fiind un actuator cheie \u00een procesele de control al fluidelor, actuatoarele electrice sunt utilizate frecvent \u00een aplica\u021biile industriale. Cele mai frecvent utilizate sisteme de bus pentru actuatoarele electrice includ Modbus, CAN, Profibus, DeviceNet, Foundation Fieldbus, HART \u0219i Ethernet. Sisteme de bus comune [...]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[8],"tags":[53,66,57,52,55,65],"class_list":["post-6422","post","type-post","status-publish","format-standard","hentry","category-ta-acutator","tag-actuator","tag-explosion-proof-actuator","tag-general-actuator","tag-fast-move-actuator","tag-tech-ref","tag-very-small-actuator-tag"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/posts\/6422","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/comments?post=6422"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/posts\/6422\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/media?parent=6422"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/categories?post=6422"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/tags?post=6422"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}