{"id":6033,"date":"2023-08-03T20:44:54","date_gmt":"2023-08-03T12:44:54","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6033"},"modified":"2025-03-27T09:47:56","modified_gmt":"2025-03-27T09:47:56","slug":"dcl-02-on-off-actuator","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/ro_ro\/sprijin\/actuator-mr\/dcl-02-pornit-oprit-actuator","title":{"rendered":"Defec\u021biuni frecvente \u0219i depanare pentru actuatoarele DCL-02 ON-OFF"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6033\" class=\"elementor elementor-6033\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-23bbd22 e-con-full e-flex e-con e-parent\" data-id=\"23bbd22\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-add184b e-con-full e-flex e-con e-child\" data-id=\"add184b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ec8fa0c elementor-widget elementor-widget-text-editor\" data-id=\"ec8fa0c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"0\" data-end=\"92\">Acest ghid se aplic\u0103 la actuatoarele din seria DCL Ultra-Small, cu urm\u0103toarele modele:<\/p><ul data-start=\"94\" data-end=\"123\"><li class=\"\" data-start=\"94\" data-end=\"103\"><p class=\"\" data-start=\"96\" data-end=\"103\">DCL-02A<\/p><\/li><li class=\"\" data-start=\"104\" data-end=\"113\"><p class=\"\" data-start=\"106\" data-end=\"113\">DCL-02B<\/p><\/li><li class=\"\" data-start=\"114\" data-end=\"123\"><p class=\"\" data-start=\"116\" data-end=\"123\">DCL-02G<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-69c14e5 elementor-widget elementor-widget-image\" data-id=\"69c14e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"176\" height=\"399\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-02-valve.webp\" class=\"attachment-full size-full wp-image-4861\" alt=\"\u534e\u6613\u7cbe\u5de7\u7cfb\u5217\u6267\u884c\u5668 DCL-02 \u914d\u9600 | Supap\u0103 de ac\u021bionare DCL-02\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b43d346 elementor-widget elementor-widget-heading\" data-id=\"b43d346\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Defec\u021biuni frecvente \u0219i metode de depanare<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e1d44fb elementor-widget elementor-widget-text-editor\" data-id=\"e1d44fb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0<\/p><table><thead><tr><th><strong>Defect<\/strong><\/th><th><strong>Cauze posibile<\/strong><\/th><th><strong>Metode de solu\u021bionare a problemelor<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>Actuatorul nu se deschide sau nu se \u00eenchide la pornirea ini\u021bial\u0103<\/strong><\/td><td>1. Cablare incorect\u0103<\/td><td>Verifica\u021bi cablajul \u00een conformitate cu schema de cablare a dispozitivului de ac\u021bionare.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Surs\u0103 de alimentare incorect\u0103<\/td><td>Asigura\u021bi-v\u0103 c\u0103 tensiunea de alimentare se \u00eencadreaz\u0103 \u00een \u00b110% din tensiunea nominal\u0103 a dispozitivului de ac\u021bionare, iar curentul este de 3 ori mai mare dec\u00e2t curentul nominal.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. \u00centrerup\u0103tor sau releu de comand\u0103 defect<\/td><td>M\u0103sura\u021bi tensiunea de intrare la borna de control a dispozitivului de ac\u021bionare utiliz\u00e2nd un multimetru pentru a verifica dac\u0103 aceasta corespunde a\u0219tept\u0103rilor.<\/td><\/tr><tr><td>\u00a0<\/td><td>4. Nepotrivirea sistemului de control<\/td><td>Testa\u021bi actuatorul cu un comutator mecanic. Dac\u0103 func\u021bioneaz\u0103 normal, verifica\u021bi logica de ie\u0219ire a sistemului de control.<\/td><\/tr><tr><td>\u00a0<\/td><td>5. Ac\u021bionatoare multiple sau ac\u021bionatoare \u0219i alte dispozitive conectate \u00een paralel<\/td><td>Comutatoarele de ac\u021bionare trebuie s\u0103 utilizeze o singur\u0103 cale de control \u0219i s\u0103 nu fie cablate \u00een paralel, deoarece acest lucru afecteaz\u0103 condensatorul de pornire.<\/td><\/tr><tr><td><strong>Ac\u021bionatorul poate doar s\u0103 deschid\u0103 sau s\u0103 \u00eenchid\u0103<\/strong><\/td><td>1. Cablare incorect\u0103<\/td><td>Verifica\u021bi cablajul utiliz\u00e2nd schema electric\u0103 a dispozitivului de ac\u021bionare.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Setarea incorect\u0103 a camei de deschidere\/\u00eenchidere complet\u0103<\/td><td>Consulta\u021bi ghidul \"Cum se regleaz\u0103 supapele de tip comutator electric\" \u0219i regla\u021bi corect pozi\u021biile camei.<\/td><\/tr><tr><td><strong>Ac\u021bionatorul se opre\u0219te \u00een mijlocul cursei<\/strong><\/td><td>1. Supap\u0103 blocat\u0103<\/td><td>Verifica\u021bi dac\u0103 exist\u0103 blocaje \u00een supap\u0103. \u00cendep\u0103rta\u021bi orice obstruc\u021bie \u0219i \u00eencerca\u021bi din nou dup\u0103 ce protec\u021bia la suprasarcin\u0103 a actuatorului se r\u0103ce\u0219te.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Material solid \u00een fluid care cauzeaz\u0103 blocarea supapei<\/td><td>Inspecta\u021bi fluidul pentru a depista particule solide care cauzeaz\u0103 blocarea supapei. Elimina\u021bi blocajul \u0219i \u00eencerca\u021bi din nou dup\u0103 ce protec\u021bia la suprasarcin\u0103 a dispozitivului de ac\u021bionare se r\u0103ce\u0219te.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Setarea incorect\u0103 a dopului de deschidere\/\u00eenchidere complet\u0103<\/td><td>Consulta\u021bi ghidul \"Cum se regleaz\u0103 supapele de tip comutator electric\" \u0219i regla\u021bi corect pozi\u021biile opritorului.<\/td><\/tr><tr><td><strong>Imposibilitatea de a roti actuatorul cu ajutorul m\u00e2nerului<\/strong><\/td><td>1. Material solid \u00een fluid care cauzeaz\u0103 blocarea supapei<\/td><td>Verifica\u021bi dac\u0103 exist\u0103 un blocaj \u00een supap\u0103. Elimina\u021bi blocajul \u0219i \u00eencerca\u021bi din nou dup\u0103 ce protec\u021bia la suprasarcin\u0103 a dispozitivului de ac\u021bionare se r\u0103ce\u0219te.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Griparea supapei<\/td><td>Inspecta\u021bi supapa pentru a depista eventuale blocaje. Elibera\u021bi blocajul \u0219i \u00eencerca\u021bi din nou dup\u0103 ce protec\u021bia la suprasarcin\u0103 a ac\u021bionatorului se r\u0103ce\u0219te.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Mecanism de reducere a ac\u021bionatorului deteriorat<\/td><td>Scoate\u021bi actuatorul din supap\u0103 \u0219i roti\u021bi m\u00e2nerul. Dac\u0103 nu se mi\u0219c\u0103, \u00eenlocui\u021bi actuatorul.<\/td><\/tr><tr><td><strong>Nu exist\u0103 semnal de feedback al pozi\u021biei<\/strong><\/td><td>1. Cablare incorect\u0103 la comutator<\/td><td>Verifica\u021bi cablajul \u00een conformitate cu schema de cablare a dispozitivului de ac\u021bionare.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Setarea incorect\u0103 a camei de deschidere\/\u00eenchidere complet\u0103<\/td><td>Consulta\u021bi ghidul \"Cum se regleaz\u0103 supapele de tip comutator electric\" \u0219i regla\u021bi corect pozi\u021bia camei.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Supracurentul cauzeaz\u0103 deteriorarea comutatorului de feedback al pozi\u021biei<\/td><td>1. Verifica\u021bi dac\u0103 camea de deschidere\/\u00eenchidere complet\u0103 apas\u0103 corect pe comutatorul de feedback al pozi\u021biei, conform ghidului.<\/td><\/tr><tr><td>\u00a0<\/td><td>\u00a0<\/td><td>2. M\u0103sura\u021bi dac\u0103 circuitul de feedback al pozi\u021biei este \u00eenchis.<\/td><\/tr><\/tbody><\/table><p>\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d58177d elementor-widget elementor-widget-heading\" data-id=\"d58177d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Verifica\u021bi dac\u0103 condi\u021biile de func\u021bionare \u00eendeplinesc cerin\u021bele parametrilor.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60cdda7 elementor-widget elementor-widget-text-editor\" data-id=\"60cdda7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"156\" data-end=\"422\">Actuatoarele electrice se pot defecta din cauza utiliz\u0103rii necorespunz\u0103toare sau a utiliz\u0103rii \u00een condi\u021bii de func\u021bionare incorecte. Atunci c\u00e2nd este utilizat \u00een condi\u021biile de func\u021bionare definite \u00een specifica\u021biile produsului, se poate a\u0219tepta ca actuatorul s\u0103 func\u021bioneze fiabil pentru o perioad\u0103 extins\u0103 f\u0103r\u0103 defec\u021biuni.<\/p><ul data-start=\"424\" data-end=\"1721\"><li class=\"\" data-start=\"424\" data-end=\"610\"><p class=\"\" data-start=\"426\" data-end=\"610\"><strong data-start=\"426\" data-end=\"445\">Tensiune de alimentare:<\/strong> Tensiunea de la sursa de alimentare trebuie s\u0103 se \u00eencadreze \u00een intervalul de tensiune nominal\u0103 de func\u021bionare a dispozitivului de ac\u021bionare. Supratensiunea sau subtensiunea poate scurta durata de via\u021b\u0103 a dispozitivului de ac\u021bionare.<\/p><\/li><li class=\"\" data-start=\"614\" data-end=\"840\"><p class=\"\" data-start=\"616\" data-end=\"840\"><strong data-start=\"616\" data-end=\"635\">Curent de alimentare:<\/strong> Curentul de pornire al motorului este semnificativ mai mare dec\u00e2t curentul nominal. Pentru a asigura o func\u021bionare fiabil\u0103, utiliza\u021bi o surs\u0103 de alimentare capabil\u0103 s\u0103 furnizeze cel pu\u021bin de 3 ori curentul nominal al dispozitivului de ac\u021bionare.<\/p><\/li><li class=\"\" data-start=\"842\" data-end=\"1035\"><p class=\"\" data-start=\"844\" data-end=\"1035\"><strong data-start=\"844\" data-end=\"860\">Temperatura:<\/strong> Asigura\u021bi-v\u0103 c\u0103 actuatorul func\u021bioneaz\u0103 \u00een intervalul s\u0103u de temperatur\u0103 nominal\u0103. Utilizarea dispozitivului de ac\u021bionare \u00een afara acestui interval poate duce la performan\u021be slabe, la reducerea duratei de via\u021b\u0103 \u0219i la o eventual\u0103 defec\u021biune.<\/p><\/li><li class=\"\" data-start=\"1037\" data-end=\"1504\"><p class=\"\" data-start=\"1039\" data-end=\"1504\"><strong data-start=\"1039\" data-end=\"1055\">Mediu:<\/strong> Actuatorul de tip comutator DCL are un grad de rezisten\u021b\u0103 la intemperii IP67, ceea ce \u00eel face potrivit at\u00e2t pentru aplica\u021bii de interior, c\u00e2t \u0219i de exterior. Acesta ofer\u0103 un grad de protec\u021bie \u00eempotriva ploii \u0219i a stropirii cu ap\u0103, contribuind la prelungirea duratei de via\u021b\u0103 a actuatorului prin protejarea acestuia de ploaie, z\u0103pad\u0103, ghea\u021b\u0103 \u0219i UV (lumina soarelui). Cu toate acestea, \u00een medii foarte corozive, componentele electronice se pot defecta prematur. Actuatoarele neprotejate \u00eempotriva exploziilor nu trebuie utilizate \u00een medii explozive.<\/p><\/li><li class=\"\" data-start=\"1506\" data-end=\"1721\"><p class=\"\" data-start=\"1508\" data-end=\"1721\"><strong data-start=\"1508\" data-end=\"1523\">Ciclu de func\u021bionare:<\/strong> Actuatorul de tip comutator DCL are un ciclu de func\u021bionare de 70% (42 de secunde de func\u021bionare pe minut, urmate de 18 secunde de repaus). Dep\u0103\u0219irea acestui ciclu de func\u021bionare poate determina intrarea motorului \u00een protec\u021bie termic\u0103.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0273976 elementor-widget elementor-widget-heading\" data-id=\"0273976\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Verifica\u021bi cablajul dispozitivului de ac\u021bionare<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9df2216 elementor-widget elementor-widget-text-editor\" data-id=\"9df2216\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"45\" data-end=\"186\">Asigura\u021bi-v\u0103 c\u0103 actuatorul este cablat corect \u00een conformitate cu diagrama de cablare furnizat\u0103 de produc\u0103tor. Urma\u021bi ace\u0219ti pa\u0219i pentru a verifica cablarea:<\/p><ol data-start=\"188\" data-end=\"1007\"><li class=\"\" data-start=\"188\" data-end=\"325\"><p class=\"\" data-start=\"191\" data-end=\"209\"><strong data-start=\"191\" data-end=\"208\">Surs\u0103 de alimentare:<\/strong><\/p><ul data-start=\"213\" data-end=\"325\"><li class=\"\" data-start=\"213\" data-end=\"321\"><p class=\"\" data-start=\"215\" data-end=\"321\">Verifica\u021bi conexiunile sursei de alimentare pentru a v\u0103 asigura c\u0103 acestea corespund tensiunii \u0219i curentului de intrare necesare actuatorului.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"326\" data-end=\"504\"><p class=\"\" data-start=\"329\" data-end=\"353\"><strong data-start=\"329\" data-end=\"353\">Conexiuni de control:<\/strong><\/p><ul data-start=\"357\" data-end=\"504\"><li class=\"\" data-start=\"357\" data-end=\"504\"><p class=\"\" data-start=\"359\" data-end=\"504\">Verifica\u021bi dac\u0103 conexiunile de control de intrare \u0219i de ie\u0219ire sunt bine fixate \u0219i \u00een configura\u021bia corect\u0103, conform schemei de cablare a dispozitivului de ac\u021bionare.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"506\" data-end=\"707\"><p class=\"\" data-start=\"509\" data-end=\"527\"><strong data-start=\"509\" data-end=\"527\">Cablare semnal:<\/strong><\/p><ul data-start=\"531\" data-end=\"707\"><li class=\"\" data-start=\"531\" data-end=\"639\"><p class=\"\" data-start=\"533\" data-end=\"639\">Verifica\u021bi cablajul pentru semnalele de control, cum ar fi 4-20mA sau 0-10V, \u00een func\u021bie de specifica\u021biile actuatorului.<\/p><\/li><li class=\"\" data-start=\"643\" data-end=\"707\"><p class=\"\" data-start=\"645\" data-end=\"707\">Confirma\u021bi c\u0103 nu exist\u0103 conexiuni sl\u0103bite sau scurtcircuite.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"709\" data-end=\"823\"><p class=\"\" data-start=\"712\" data-end=\"726\"><strong data-start=\"712\" data-end=\"726\">\u00cemp\u0103m\u00e2ntare:<\/strong><\/p><ul data-start=\"730\" data-end=\"823\"><li class=\"\" data-start=\"730\" data-end=\"823\"><p class=\"\" data-start=\"732\" data-end=\"823\">Asigura\u021bi-v\u0103 c\u0103 dispozitivul de ac\u021bionare este \u00eemp\u0103m\u00e2ntat corespunz\u0103tor pentru a preveni interferen\u021bele sau deterior\u0103rile electrice.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"825\" data-end=\"1007\"><p class=\"\" data-start=\"828\" data-end=\"863\"><strong data-start=\"828\" data-end=\"863\">Conexiuni la alte echipamente:<\/strong><\/p><ul data-start=\"867\" data-end=\"1007\"><li class=\"\" data-start=\"867\" data-end=\"1007\"><p class=\"\" data-start=\"869\" data-end=\"1007\">Dac\u0103 actuatorul este conectat la alte dispozitive, asigura\u021bi-v\u0103 c\u0103 \u0219i aceste conexiuni sunt corecte \u0219i nu provoac\u0103 interferen\u021be sau probleme de alimentare.<\/p><\/li><\/ul><\/li><\/ol><p class=\"\" data-start=\"1009\" data-end=\"1155\">Dac\u0103 cablajul pare corect, dar actuatorul continu\u0103 s\u0103 func\u021bioneze defectuos, este posibil s\u0103 fie necesar\u0103 depanarea suplimentar\u0103 sau asisten\u021ba unui tehnician.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-84857ae e-flex e-con-boxed e-con e-parent\" data-id=\"84857ae\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cf23cb0 elementor-widget elementor-widget-template\" data-id=\"cf23cb0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"template.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-template\">\n\t\t\t\t\t<div data-elementor-type=\"section\" data-elementor-id=\"10969\" class=\"elementor elementor-10969\" data-elementor-post-type=\"elementor_library\">\n\t\t\t<div class=\"elementor-element elementor-element-d642a8e e-flex e-con-boxed e-con e-parent\" data-id=\"d642a8e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-4dcc388 e-con-full e-flex e-con e-child\" data-id=\"4dcc388\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-09f4232 elementor-widget elementor-widget-heading\" data-id=\"09f4232\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">A - Cu 2 ie\u0219iri active de semnal de pozi\u021bie final\u0103<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-daf3293 elementor-widget elementor-widget-image\" data-id=\"daf3293\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"341\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-a.webp\" class=\"attachment-full size-full wp-image-4860\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668A\u578b\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-14e5438 elementor-widget elementor-widget-text-editor\" data-id=\"14e5438\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Ac\u021bionator de control pentru deschidere sau \u00eenchidere cu K<\/li><li>Terminalul de ie\u0219ire al pozi\u021biei finale OPEN\/CLOSE va trimite evenimentul ca o form\u0103 de semnal activ 220VAC atunci c\u00e2nd a fost atins\u0103 pozi\u021bia final\u0103.<\/li><\/ul><p>\u00a0<\/p><p><strong>Detalii de conectare:<\/strong><\/p><ol><li>Conectarea neutrului aliment\u0103rii AC85-220V la P1.<\/li><li>Comuta\u021bi linia AC85-220V la CLOSE(P2) pentru a \u00eenchide supapa<\/li><li>Comuta\u021bi linia AC85-220V la OPEN(P3) pentru a deschide supapa.<\/li><li>P5 este terminalul pozi\u021biei finale OPEN care va emite o surs\u0103 AC220V care poate fi utilizat\u0103 pentru a ac\u021biona o lumin\u0103 de indicare atunci c\u00e2nd actuatorul a atins pozi\u021bia final\u0103 de deschidere.<\/li><li>P6 este terminalul OPEN de pozi\u021bie final\u0103 care va emite o surs\u0103 AC220V care poate fi utilizat\u0103 pentru a ac\u021biona o lumin\u0103 de indicare atunci c\u00e2nd actuatorul a atins pozi\u021bia final\u0103 de \u00eenchidere.<\/li><li>Conecta\u021bi p\u0103m\u00e2ntul la P7.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f1a67a7 e-con-full e-flex e-con e-child\" data-id=\"f1a67a7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a942089 elementor-widget elementor-widget-heading\" data-id=\"a942089\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">B - Cu 2 comutatoare pasive de pozi\u021bie final\u0103<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-766f845 elementor-widget elementor-widget-image\" data-id=\"766f845\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"348\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-b.webp\" class=\"attachment-full size-full wp-image-4858\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668B\u578b\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-799d994 elementor-widget elementor-widget-text-editor\" data-id=\"799d994\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Ac\u021bionator de control pentru deschidere sau \u00eenchidere cu K<\/li><li>Terminalul de ie\u0219ire al pozi\u021biei finale OPEN\/CLOSE va trimite evenimentul ca o form\u0103 de semnal pasiv atunci c\u00e2nd a fost atins\u0103 pozi\u021bia final\u0103.<\/li><\/ul><p>\u00a0<\/p><p><strong>Detalii de conectare:<\/strong><\/p><ol><li>Conectarea neutrului aliment\u0103rii AC85-220V la P1.<\/li><li>Comuta\u021bi linia AC85-220V la CLOSE(P2) pentru a \u00eenchide supapa<\/li><li>Comuta\u021bi linia AC85-220V la OPEN(P3) pentru a deschide supapa.<\/li><li>P4 este COM pentru semnalul de contact pasiv al pozi\u021biei finale OPEN\/CLOSE care este conectat \u00een mod normal la semnalul GND.<\/li><li>P5 este terminalul pozi\u021biei finale OPEN care va fi conectat la COM atunci c\u00e2nd actuatorul a atins pozi\u021bia final\u0103 de deschidere.<\/li><li>P6 este terminalul CLOSE al pozi\u021biei finale, care va fi conectat la COM atunci c\u00e2nd actuatorul a atins pozi\u021bia final\u0103 de \u00eenchidere.<\/li><li>Conecta\u021bi p\u0103m\u00e2ntul la P7.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-738bf4f e-con-full e-flex e-con e-child\" data-id=\"738bf4f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5a73aaa elementor-widget elementor-widget-heading\" data-id=\"5a73aaa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">G - Motor DC cu 2 comutatoare de pozi\u021bie final\u0103<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8c393f4 elementor-widget elementor-widget-image\" data-id=\"8c393f4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"391\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-g.webp\" class=\"attachment-full size-full wp-image-4853\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668G\u578b\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a35d4cf elementor-widget elementor-widget-text-editor\" data-id=\"a35d4cf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Ac\u021bionator de control pentru a deschide sau \u00eenchide prin direc\u021bia aliment\u0103rii cu energie \u00eentre terminalul 1 \u0219i 2<\/li><li>Terminalul de ie\u0219ire al pozi\u021biei finale OPEN\/CLOSE va trimite evenimentul ca o form\u0103 de semnal pasiv atunci c\u00e2nd a fost atins\u0103 pozi\u021bia final\u0103.<\/li><\/ul><p>\u00a0<\/p><p><strong>Detalii de conectare:<\/strong><\/p><ol><li>Conectarea DC24V+ la P1 \u0219i DC24V- la P2 pentru a \u00eenchide supapa.<\/li><li>Conecta\u021bi DC24V+ la P2 \u0219i DC24V- la P1 pentru a \u00eenchide supapa.<\/li><li>P3 este COM pentru semnalul de contact pasiv al pozi\u021biei finale OPEN\/CLOSE care este conectat \u00een mod normal la semnalul GND.<\/li><li>P4 este terminalul pozi\u021biei finale OPEN care va fi conectat la COM atunci c\u00e2nd actuatorul a atins pozi\u021bia final\u0103 de deschidere.<\/li><li>P5 este terminalul CLOSE al pozi\u021biei finale care va fi conectat la COM atunci c\u00e2nd actuatorul a atins pozi\u021bia final\u0103 de \u00eenchidere.<\/li><li>Conecta\u021bi p\u0103m\u00e2ntul la P7.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ff65758 e-con-full e-flex e-con e-parent\" data-id=\"ff65758\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-d5dc048 e-con-full e-flex e-con e-child\" data-id=\"d5dc048\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-527200f elementor-widget elementor-widget-text-editor\" data-id=\"527200f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Not\u0103\uff1a<\/p><ul><li>Circuitul din interiorul casetei punctate este circuitul intern al dispozitivului de ac\u021bionare. \u00cen timp ce circuitul exterior este o demonstra\u021bie a conexiunii electrice pentru utilizarea actuatorului.<\/li><li>Dac\u0103 ave\u021bi alte cerin\u021be specifice privind circuitul de conectare, v\u0103 rug\u0103m s\u0103 nu ezita\u021bi s\u0103 contacta\u021bi asisten\u021ba noastr\u0103 tehnic\u0103.\u00a0<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-002d845 elementor-widget elementor-widget-text-editor\" data-id=\"002d845\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Atunci c\u00e2nd efectua\u021bi depanarea la fa\u021ba locului, nu ezita\u021bi s\u0103 contacta\u021bi imediat personalul nostru de service tehnic pentru asisten\u021b\u0103 \u00een diagnosticarea \u0219i rezolvarea problemei. <br \/>Num\u0103r de telefon de contact: 13026331611 (Mr. Chen)<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Acest ghid este aplicabil actuatoarelor din seria DCL Ultra-Small, cu urm\u0103toarele modele: DCL-02A DCL-02B DCL-02G Defec\u021biuni comune \u0219i metode de depanare Defec\u021biune Cauze posibile Metode de depanare Actuatorul nu se deschide sau nu se \u00eenchide la pornirea ini\u021bial\u0103 1. Cablare incorect\u0103 Verifica\u021bi cablajul conform schemei de conectare a actuatorului. 2. Alimentare incorect\u0103 Asigura\u021bi-v\u0103 [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[103],"tags":[53],"class_list":["post-6033","post","type-post","status-publish","format-standard","hentry","category-mr-actuator","tag-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/posts\/6033","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/comments?post=6033"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/posts\/6033\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/media?parent=6033"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/categories?post=6033"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/ro_ro\/wp-json\/wp\/v2\/tags?post=6033"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}