{"id":6033,"date":"2023-08-03T20:44:54","date_gmt":"2023-08-03T12:44:54","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6033"},"modified":"2025-03-27T09:47:56","modified_gmt":"2025-03-27T09:47:56","slug":"dcl-02-on-off-actuator","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/pt_pt\/apoio\/atuador-mr\/dcl-02-on-off-actuator","title":{"rendered":"Problemas comuns e solu\u00e7\u00e3o de problemas para atuadores liga\/desliga DCL-02"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6033\" class=\"elementor elementor-6033\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-23bbd22 e-con-full e-flex e-con e-parent\" data-id=\"23bbd22\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-add184b e-con-full e-flex e-con e-child\" data-id=\"add184b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ec8fa0c elementor-widget elementor-widget-text-editor\" data-id=\"ec8fa0c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"0\" data-end=\"92\">This guide is applicable to the DCL Ultra-Small Series actuators, with the following models:<\/p><ul data-start=\"94\" data-end=\"123\"><li class=\"\" data-start=\"94\" data-end=\"103\"><p class=\"\" data-start=\"96\" data-end=\"103\">DCL-02A<\/p><\/li><li class=\"\" data-start=\"104\" data-end=\"113\"><p class=\"\" data-start=\"106\" data-end=\"113\">DCL-02B<\/p><\/li><li class=\"\" data-start=\"114\" data-end=\"123\"><p class=\"\" data-start=\"116\" data-end=\"123\">DCL-02G<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-69c14e5 elementor-widget elementor-widget-image\" data-id=\"69c14e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"176\" height=\"399\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-02-valve.webp\" class=\"attachment-full size-full wp-image-4861\" alt=\"\u534e\u6613\u7cbe\u5de7\u7cfb\u5217\u6267\u884c\u5668 DCL-02 \u914d\u9600 | V\u00e1lvula Atuadora DCL-02\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b43d346 elementor-widget elementor-widget-heading\" data-id=\"b43d346\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Common Faults and Troubleshooting Methods<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e1d44fb elementor-widget elementor-widget-text-editor\" data-id=\"e1d44fb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0<\/p><table><thead><tr><th><strong>Falta<\/strong><\/th><th><strong>Possible Causes<\/strong><\/th><th><strong>M\u00e9todos de resolu\u00e7\u00e3o de problemas<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>Actuator does not open or close on initial start<\/strong><\/td><td>1. Fia\u00e7\u00e3o incorreta<\/td><td>Check the wiring according to the actuator\u2019s wiring diagram.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Fonte de alimenta\u00e7\u00e3o incorreta<\/td><td>Ensure the power supply voltage is within \u00b110% of the actuator\u2019s rated voltage and the current is 3 times the rated current.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Faulty control switch or relay<\/td><td>Measure the input voltage at the actuator&#8217;s control terminal using a multimeter to verify it matches expectations.<\/td><\/tr><tr><td>\u00a0<\/td><td>4. Control system mismatch<\/td><td>Test the actuator with a mechanical switch. If it operates normally, verify the control system&#8217;s output logic.<\/td><\/tr><tr><td>\u00a0<\/td><td>5. Multiple actuators or actuators and other devices connected in parallel<\/td><td>Switch actuators should use single-path control and not be wired in parallel, as this affects the startup capacitor.<\/td><\/tr><tr><td><strong>Actuator can only open or close<\/strong><\/td><td>1. Fia\u00e7\u00e3o incorreta<\/td><td>Check the wiring using the actuator\u2019s wiring diagram.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Incorrect full open\/close cam setting<\/td><td>Refer to the &#8220;How to Set Electric Switch-Type Valves&#8221; guide and correctly set the cam positions.<\/td><\/tr><tr><td><strong>Actuator stops in the middle of travel<\/strong><\/td><td>1. Valve jammed<\/td><td>Check for blockages in the valve. Clear any obstruction and retry after the actuator&#8217;s overload protection cools.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Solid material in fluid causing valve jam<\/td><td>Inspect the fluid for solid particles causing valve jams. Clear the jam and retry after the actuator\u2019s overload protection cools.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Incorrect full open\/close stopper setting<\/td><td>Refer to the &#8220;How to Set Electric Switch-Type Valves&#8221; guide and correctly adjust the stopper positions.<\/td><\/tr><tr><td><strong>Unable to turn actuator using the handle<\/strong><\/td><td>1. Solid material in fluid causing valve to seize<\/td><td>Check for blockage in the valve. Clear the blockage and retry after the actuator\u2019s overload protection cools.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Valve seizing<\/td><td>Inspect the valve for jamming. Clear the blockage and retry after the actuator\u2019s overload protection cools.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Damaged actuator reduction mechanism<\/td><td>Remove the actuator from the valve and rotate the handle. If it doesn\u2019t move, replace the actuator.<\/td><\/tr><tr><td><strong>No position feedback signal<\/strong><\/td><td>1. Incorrect wiring at the switch<\/td><td>Check the wiring according to the actuator\u2019s wiring diagram.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Incorrect full open\/close cam setting<\/td><td>Refer to the &#8220;How to Set Electric Switch-Type Valves&#8221; guide and set the cam position correctly.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Overcurrent causing position feedback switch damage<\/td><td>1. Check if the full open\/close cam is pressing on the position feedback switch correctly, as per the guide.<\/td><\/tr><tr><td>\u00a0<\/td><td>\u00a0<\/td><td>2. Measure if the position feedback circuit is closed.<\/td><\/tr><\/tbody><\/table><p>\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d58177d elementor-widget elementor-widget-heading\" data-id=\"d58177d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Verify that the operating conditions meet the parameter requirements.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60cdda7 elementor-widget elementor-widget-text-editor\" data-id=\"60cdda7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"156\" data-end=\"422\">Electric actuators may fail due to improper use or being used in incorrect operating conditions. When used within the operating conditions defined in the product specifications, the actuator can be expected to operate reliably for an extended period without failure.<\/p><ul data-start=\"424\" data-end=\"1721\"><li class=\"\" data-start=\"424\" data-end=\"610\"><p class=\"\" data-start=\"426\" data-end=\"610\"><strong data-start=\"426\" data-end=\"445\">Supply Voltage:<\/strong> The voltage from the power supply must be within the rated operating voltage range of the actuator. Overvoltage or undervoltage may shorten the actuator&#8217;s lifespan.<\/p><\/li><li class=\"\" data-start=\"614\" data-end=\"840\"><p class=\"\" data-start=\"616\" data-end=\"840\"><strong data-start=\"616\" data-end=\"635\">Supply Current:<\/strong> The starting current of the motor is significantly higher than the rated current. To ensure reliable operation, use a power supply capable of delivering at least 3 times the rated current of the actuator.<\/p><\/li><li class=\"\" data-start=\"842\" data-end=\"1035\"><p class=\"\" data-start=\"844\" data-end=\"1035\"><strong data-start=\"844\" data-end=\"860\">Temperatura:<\/strong> Ensure the actuator operates within its rated temperature range. Using the actuator outside this range may result in poor performance, reduced lifespan, and eventual failure.<\/p><\/li><li class=\"\" data-start=\"1037\" data-end=\"1504\"><p class=\"\" data-start=\"1039\" data-end=\"1504\"><strong data-start=\"1039\" data-end=\"1055\">Ambiente:<\/strong> The DCL switch-type actuator has an IP67 weatherproof rating, making it suitable for both indoor and outdoor applications. It offers a degree of protection against rain and splashing water, helping to prolong the actuator\u2019s life by shielding it from rain, snow, ice, and UV (sunlight). However, in highly corrosive environments, electronic components may fail prematurely. Non-explosion-proof actuators should not be used in explosive environments.<\/p><\/li><li class=\"\" data-start=\"1506\" data-end=\"1721\"><p class=\"\" data-start=\"1508\" data-end=\"1721\"><strong data-start=\"1508\" data-end=\"1523\">Duty Cycle:<\/strong> The DCL switch-type actuator has a duty cycle of 70% (42 seconds of operation per minute, followed by 18 seconds of rest). Exceeding this duty cycle may cause the motor to enter thermal protection.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0273976 elementor-widget elementor-widget-heading\" data-id=\"0273976\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Check the Wiring of the Actuator<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9df2216 elementor-widget elementor-widget-text-editor\" data-id=\"9df2216\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"45\" data-end=\"186\">Ensure the actuator is wired correctly according to the wiring diagram provided by the manufacturer. Follow these steps to verify the wiring:<\/p><ol data-start=\"188\" data-end=\"1007\"><li class=\"\" data-start=\"188\" data-end=\"325\"><p class=\"\" data-start=\"191\" data-end=\"209\"><strong data-start=\"191\" data-end=\"208\">Power Supply:<\/strong><\/p><ul data-start=\"213\" data-end=\"325\"><li class=\"\" data-start=\"213\" data-end=\"321\"><p class=\"\" data-start=\"215\" data-end=\"321\">Check the power supply connections to ensure they match the actuator&#8217;s required input voltage and current.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"326\" data-end=\"504\"><p class=\"\" data-start=\"329\" data-end=\"353\"><strong data-start=\"329\" data-end=\"353\">Control Connections:<\/strong><\/p><ul data-start=\"357\" data-end=\"504\"><li class=\"\" data-start=\"357\" data-end=\"504\"><p class=\"\" data-start=\"359\" data-end=\"504\">Verify that the input and output control connections are securely attached and in the correct configuration as per the actuator\u2019s wiring diagram.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"506\" data-end=\"707\"><p class=\"\" data-start=\"509\" data-end=\"527\"><strong data-start=\"509\" data-end=\"527\">Signal Wiring:<\/strong><\/p><ul data-start=\"531\" data-end=\"707\"><li class=\"\" data-start=\"531\" data-end=\"639\"><p class=\"\" data-start=\"533\" data-end=\"639\">Check the wiring for control signals, such as 4-20mA or 0-10V, depending on the actuator\u2019s specifications.<\/p><\/li><li class=\"\" data-start=\"643\" data-end=\"707\"><p class=\"\" data-start=\"645\" data-end=\"707\">Confirm that there are no loose connections or short circuits.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"709\" data-end=\"823\"><p class=\"\" data-start=\"712\" data-end=\"726\"><strong data-start=\"712\" data-end=\"726\">Grounding:<\/strong><\/p><ul data-start=\"730\" data-end=\"823\"><li class=\"\" data-start=\"730\" data-end=\"823\"><p class=\"\" data-start=\"732\" data-end=\"823\">Ensure that the actuator is properly grounded to prevent electrical interference or damage.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"825\" data-end=\"1007\"><p class=\"\" data-start=\"828\" data-end=\"863\"><strong data-start=\"828\" data-end=\"863\">Connections to Other Equipment:<\/strong><\/p><ul data-start=\"867\" data-end=\"1007\"><li class=\"\" data-start=\"867\" data-end=\"1007\"><p class=\"\" data-start=\"869\" data-end=\"1007\">If the actuator is connected to other devices, make sure those connections are also correct and do not cause interference or power issues.<\/p><\/li><\/ul><\/li><\/ol><p class=\"\" data-start=\"1009\" data-end=\"1155\">If the wiring appears correct, but the actuator is still malfunctioning, further troubleshooting or assistance from a technician may be necessary.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-84857ae e-flex e-con-boxed e-con e-parent\" data-id=\"84857ae\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cf23cb0 elementor-widget elementor-widget-template\" data-id=\"cf23cb0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"template.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-template\">\n\t\t\t\t\t<div data-elementor-type=\"section\" data-elementor-id=\"10969\" class=\"elementor elementor-10969\" data-elementor-post-type=\"elementor_library\">\n\t\t\t<div class=\"elementor-element elementor-element-d642a8e e-flex e-con-boxed e-con e-parent\" data-id=\"d642a8e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-4dcc388 e-con-full e-flex e-con e-child\" data-id=\"4dcc388\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-09f4232 elementor-widget elementor-widget-heading\" data-id=\"09f4232\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">A - Com 2 sa\u00eddas de sinal de posi\u00e7\u00e3o final activas<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-daf3293 elementor-widget elementor-widget-image\" data-id=\"daf3293\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"341\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-a.webp\" class=\"attachment-full size-full wp-image-4860\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668A\u578b\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-14e5438 elementor-widget elementor-widget-text-editor\" data-id=\"14e5438\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Controlo do atuador para abrir ou fechar com K<\/li><li>O terminal de sa\u00edda da posi\u00e7\u00e3o final OPEN\/CLOSE enviar\u00e1 o evento como um sinal ativo de 220VAC quando a posi\u00e7\u00e3o final for atingida.<\/li><\/ul><p>\u00a0<\/p><p><strong>Detalhes de liga\u00e7\u00e3o:<\/strong><\/p><ol><li>Liga\u00e7\u00e3o do neutro da alimenta\u00e7\u00e3o AC85-220V a P1.<\/li><li>Comutar a linha AC85-220V para CLOSE(P2) para fechar a v\u00e1lvula<\/li><li>Comutar a linha AC85-220V para OPEN(P3) para abrir a v\u00e1lvula.<\/li><li>P5 \u00e9 o terminal de posi\u00e7\u00e3o final ABERTO que produzir\u00e1 uma fonte de AC220V que pode ser utilizada para acionar uma luz de indica\u00e7\u00e3o quando o atuador atingir a posi\u00e7\u00e3o final de aberto.<\/li><li>P6 \u00e9 o terminal de posi\u00e7\u00e3o final ABERTO que produzir\u00e1 uma fonte de AC220V que pode ser utilizada para acionar uma luz de indica\u00e7\u00e3o quando o atuador atingir a posi\u00e7\u00e3o final de fecho.<\/li><li>Ligar a terra a P7.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f1a67a7 e-con-full e-flex e-con e-child\" data-id=\"f1a67a7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a942089 elementor-widget elementor-widget-heading\" data-id=\"a942089\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">B - Com 2 interruptores passivos de posi\u00e7\u00e3o final<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-766f845 elementor-widget elementor-widget-image\" data-id=\"766f845\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"348\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-b.webp\" class=\"attachment-full size-full wp-image-4858\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668B\u578b\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-799d994 elementor-widget elementor-widget-text-editor\" data-id=\"799d994\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Controlo do atuador para abrir ou fechar com K<\/li><li>O terminal de sa\u00edda da posi\u00e7\u00e3o final OPEN\/CLOSE enviar\u00e1 o evento como uma forma de sinal passivo quando a posi\u00e7\u00e3o final for atingida.<\/li><\/ul><p>\u00a0<\/p><p><strong>Detalhes de liga\u00e7\u00e3o:<\/strong><\/p><ol><li>Liga\u00e7\u00e3o do neutro da alimenta\u00e7\u00e3o AC85-220V a P1.<\/li><li>Comutar a linha AC85-220V para CLOSE(P2) para fechar a v\u00e1lvula<\/li><li>Comutar a linha AC85-220V para OPEN(P3) para abrir a v\u00e1lvula.<\/li><li>P4 \u00e9 o COM para o sinal de contacto passivo da posi\u00e7\u00e3o final ABERTO\/FECHADO que est\u00e1 normalmente ligado ao sinal GND.<\/li><li>P5 \u00e9 o terminal de posi\u00e7\u00e3o final ABERTO que ser\u00e1 ligado a COM quando o atuador atingir a posi\u00e7\u00e3o final de aberto.<\/li><li>P6 \u00e9 o terminal FECHADO de posi\u00e7\u00e3o final que ser\u00e1 ligado a COM quando o atuador atingir a posi\u00e7\u00e3o final de fecho.<\/li><li>Ligar a terra a P7.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-738bf4f e-con-full e-flex e-con e-child\" data-id=\"738bf4f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5a73aaa elementor-widget elementor-widget-heading\" data-id=\"5a73aaa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">G - Motor DC com 2 interruptores de posi\u00e7\u00e3o final<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8c393f4 elementor-widget elementor-widget-image\" data-id=\"8c393f4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"391\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-g.webp\" class=\"attachment-full size-full wp-image-4853\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668G\u578b\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a35d4cf elementor-widget elementor-widget-text-editor\" data-id=\"a35d4cf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Atuador de controlo para abrir ou fechar atrav\u00e9s da dire\u00e7\u00e3o da alimenta\u00e7\u00e3o entre os terminais 1 e 2<\/li><li>O terminal de sa\u00edda da posi\u00e7\u00e3o final OPEN\/CLOSE enviar\u00e1 o evento como uma forma de sinal passivo quando a posi\u00e7\u00e3o final for atingida.<\/li><\/ul><p>\u00a0<\/p><p><strong>Detalhes de liga\u00e7\u00e3o:<\/strong><\/p><ol><li>Ligar DC24V+ a P1 e DC24V- a P2 para fechar a v\u00e1lvula.<\/li><li>Ligar DC24V+ a P2 e DC24V- a P1 para fechar a v\u00e1lvula.<\/li><li>P3 \u00e9 o COM para o sinal de contacto passivo da posi\u00e7\u00e3o final ABERTO\/FECHADO que est\u00e1 normalmente ligado ao sinal GND.<\/li><li>P4 \u00e9 o terminal de posi\u00e7\u00e3o final ABERTO que ser\u00e1 ligado a COM quando o atuador atingir a posi\u00e7\u00e3o final de aberto.<\/li><li>P5 \u00e9 o terminal FECHADO de posi\u00e7\u00e3o final que ser\u00e1 ligado a COM quando o atuador atingir a posi\u00e7\u00e3o final de fecho.<\/li><li>Ligar a terra a P7.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ff65758 e-con-full e-flex e-con e-parent\" data-id=\"ff65758\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-d5dc048 e-con-full e-flex e-con e-child\" data-id=\"d5dc048\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-527200f elementor-widget elementor-widget-text-editor\" data-id=\"527200f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Nota\uff1a<\/p><ul><li>O circuito dentro da caixa tracejada \u00e9 o circuito interno do atuador. Enquanto o circuito exterior \u00e9 uma demonstra\u00e7\u00e3o da liga\u00e7\u00e3o el\u00e9ctrica para utilizar o atuador.<\/li><li>Se tiver outros requisitos espec\u00edficos sobre o circuito de liga\u00e7\u00e3o, n\u00e3o hesite em contactar o nosso apoio t\u00e9cnico.\u00a0<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-002d845 elementor-widget elementor-widget-text-editor\" data-id=\"002d845\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>When conducting troubleshooting on-site, feel free to contact our technical service personnel immediately for assistance in diagnosing and resolving the issue. <br \/>Contact phone number: 13026331611 (Mr. Chen)<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Este guia aplica-se aos atuadores da S\u00e9rie Ultracompacta DCL, com os seguintes modelos: DCL-02A, DCL-02B e DCL-02G. Problemas Comuns e M\u00e9todos de Solu\u00e7\u00e3o de Problemas: Problema: Poss\u00edveis Causas: O atuador n\u00e3o abre ou fecha na inicializa\u00e7\u00e3o. M\u00e9todos de Solu\u00e7\u00e3o de Problemas: 1. Fia\u00e7\u00e3o incorreta: Verifique a fia\u00e7\u00e3o de acordo com o diagrama de fia\u00e7\u00e3o do atuador. 2. Alimenta\u00e7\u00e3o incorreta: Certifique-se de que [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[103],"tags":[53],"class_list":["post-6033","post","type-post","status-publish","format-standard","hentry","category-mr-actuator","tag-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/pt_pt\/wp-json\/wp\/v2\/posts\/6033","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/pt_pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/pt_pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/pt_pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/pt_pt\/wp-json\/wp\/v2\/comments?post=6033"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/pt_pt\/wp-json\/wp\/v2\/posts\/6033\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/pt_pt\/wp-json\/wp\/v2\/media?parent=6033"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/pt_pt\/wp-json\/wp\/v2\/categories?post=6033"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/pt_pt\/wp-json\/wp\/v2\/tags?post=6033"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}