{"id":6032,"date":"2023-08-03T20:13:29","date_gmt":"2023-08-03T12:13:29","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6032"},"modified":"2025-03-27T08:36:44","modified_gmt":"2025-03-27T08:36:44","slug":"on-off-actuator","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/pl_pl\/wsparcie\/mr-actuator\/on-off-actuator","title":{"rendered":"Typowe usterki i rozwi\u0105zywanie problem\u00f3w si\u0142ownik\u00f3w W\u0141.-WY\u0141."},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6032\" class=\"elementor elementor-6032\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c46c850 e-con-full e-flex e-con e-child\" data-id=\"c46c850\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bbe1880 elementor-widget elementor-widget-text-editor\" data-id=\"bbe1880\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>This guide applies to the switch-type actuators of the DCL explosion-proof series, standard series, and quick-open series. The models are as follows:<\/p><p><strong>Weather-proof Actuator:<\/strong> DCL-05, DCL-10, DCL-20, DCL-40, DCL-60, DCL-100, DCL-160, DCL-250<br \/><strong>Explosion-Proof Actuator:<\/strong> DCL-Ex05, DCL-Ex10, DCL-Ex20, DCL-Ex40, DCL-Ex60<br \/><strong>Quick-Turn Actuator:<\/strong> DCL-K05, DCL-K10, DCL-K20, DCL-K40, DCL-K100<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e76288 elementor-widget elementor-widget-heading\" data-id=\"3e76288\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Typowe usterki i metody rozwi\u0105zywania problem\u00f3w<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f9da4e2 elementor-widget elementor-widget-text-editor\" data-id=\"f9da4e2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0<\/p><table><thead><tr><th><strong>Usterka<\/strong><\/th><th><strong>Mo\u017cliwe przyczyny<\/strong><\/th><th><strong>Troubleshooting Methods<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>Si\u0142ownik nie otwiera si\u0119 ani nie zamyka podczas uruchamiania<\/strong><\/td><td><p>1. Incorrect wiring.<\/p><p>2. Incorrect power supply.<\/p><p>3. Faulty control switch or relay.<\/p><p>4. Control system mismatch.<\/p><p>5. Multiple actuators or actuator in parallel with other devices.<\/p><\/td><td><p>1. Check the wiring against the actuator\u2019s wiring diagram to ensure it is correct.<\/p><p>2. Verify power supply output voltage is \u00b110% of rated voltage, and the current is at least three times the actuator\u2019s rated current.<\/p><p>3. Use a multimeter to measure input voltage at the actuator&#8217;s control terminal and confirm it matches expected values.<\/p><p>4. Use a mechanical switch to test actuator operation. If it works, verify the control system output logic.<\/p><p>5. Switch-type actuators should not be connected in parallel with other devices; use a single control circuit.<\/p><\/td><\/tr><tr><td><strong>Actuator only opens or closes, not both<\/strong><\/td><td><p>1. Incorrect wiring.<\/p><p>2. Incorrect full open\/full close cam settings.<\/p><\/td><td><p>1. Use a mechanical switch to test actuator functionality. If it works, verify the control system output logic.<\/p><p>2. Check actuator\u2019s wiring against the wiring diagram.<\/p><p>3. Adjust the cam settings according to the &#8220;How to Set Switch-type Electric Valves&#8221; manual.<\/p><\/td><\/tr><tr><td><strong>Actuator stops in the middle of its stroke<\/strong><\/td><td><p>1. Valve is stuck.<\/p><p>2. Solid particles in the fluid medium causing valve blockage.<\/p><p>3. Incorrect full open\/full close block settings.<\/p><\/td><td><p>1. Check if the valve is stuck. Remove obstructions and retry after the actuator cools down from overload protection.<\/p><p>2. Inspect the fluid medium for solid particles. Remove any blockage and retry after cooling.<\/p><p>3. Adjust block settings according to the &#8220;How to Set Switch-type Electric Valves&#8221; manual.<\/p><\/td><\/tr><tr><td><strong>Nie mo\u017cna obr\u00f3ci\u0107 si\u0142ownika za pomoc\u0105 ko\u0142a r\u0119cznego<\/strong><\/td><td><p>1. Solid particles in the fluid medium causing valve blockage.<\/p><p>2. Valve is stuck.<\/p><p>3. Actuator\u2019s reduction mechanism is damaged.<\/p><\/td><td><p>1. Check fluid medium for particles causing blockage. Remove obstructions and retry after cooling.<\/p><p>2. Inspect valve for any stuck parts. Remove blockage and retry.<\/p><p>3. If actuator cannot be turned by hand, remove it from the valve. If it still doesn&#8217;t turn, replace with a new actuator.<\/p><\/td><\/tr><tr><td><strong>Brak wyj\u015bcia sygna\u0142u sprz\u0119\u017cenia zwrotnego po\u0142o\u017cenia<\/strong><\/td><td><p>1. Incorrect switch wiring.<\/p><p>2. Incorrect full open\/full close cam settings.<\/p><p>3. Overcurrent causing damage to the position feedback signal switch.<\/p><\/td><td><p>1. Check wiring of the switch against the actuator\u2019s wiring diagram to ensure it is correct.<\/p><p>2. Verify full open\/full close cam is properly compressing the position feedback switch.<\/p><p>3. Measure the position feedback circuit to check if the switch is intact and properly connected.<\/p><\/td><\/tr><\/tbody><\/table><p>\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-27fe35c elementor-widget elementor-widget-heading\" data-id=\"27fe35c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Please check if the operating conditions meet the parameter requirements.<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-26c5591 elementor-widget elementor-widget-text-editor\" data-id=\"26c5591\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"3\" data-end=\"303\">Electric actuators may fail due to improper use or operating in incorrect conditions. To ensure long-term, trouble-free operation, the actuator must be used within the operating conditions specified in the product datasheet.<\/p><ul data-start=\"305\" data-end=\"1601\" data-is-last-node=\"\" data-is-only-node=\"\"><li class=\"\" data-start=\"305\" data-end=\"478\"><p class=\"\" data-start=\"307\" data-end=\"478\"><strong data-start=\"307\" data-end=\"332\">Power Supply Voltage:<\/strong> The supply voltage must be within the actuator&#8217;s rated operating voltage range. Overvoltage or undervoltage may reduce the actuator&#8217;s lifespan.<\/p><\/li><li class=\"\" data-start=\"479\" data-end=\"734\"><p class=\"\" data-start=\"481\" data-end=\"734\"><strong data-start=\"481\" data-end=\"506\">Power Supply Current:<\/strong> Since the motor&#8217;s starting current is significantly higher than the rated current, please ensure that the power supply can provide a current capacity at least 3 times the actuator&#8217;s rated current to ensure reliable operation.<\/p><\/li><li class=\"\" data-start=\"735\" data-end=\"950\"><p class=\"\" data-start=\"737\" data-end=\"950\"><strong data-start=\"737\" data-end=\"753\">Temperatura:<\/strong> Ensure that the actuator operates within the rated temperature range. Operating the actuator outside the specified temperature range may cause malfunction, reduced lifespan, or eventual failure.<\/p><\/li><li class=\"\" data-start=\"951\" data-end=\"1385\"><p class=\"\" data-start=\"953\" data-end=\"1385\"><strong data-start=\"953\" data-end=\"969\">\u015arodowisko:<\/strong> The DCL switch-type actuators are rated at IP67 for wind and rain protection. They are generally suitable for both indoor and outdoor use, providing protection against rain, splashes, and UV exposure (sunlight), which typically extends the product&#8217;s lifespan. Extremely corrosive environments may cause premature failure of electronic components. Do not use non-explosion-proof actuators in explosive atmospheres.<\/p><\/li><li class=\"\" data-start=\"1386\" data-end=\"1601\"><p class=\"\" data-start=\"1388\" data-end=\"1601\"><strong data-start=\"1388\" data-end=\"1403\">Duty Cycle:<\/strong> The duty cycle of the DCL switch-type actuator is 70% (42 seconds of operation per minute, with a required 18 seconds off). Exceeding a 70% duty cycle will trigger thermal protection for the motor.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0f084a1 elementor-widget elementor-widget-heading\" data-id=\"0f084a1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Check if the wiring of the actuator is correct.<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-82b97d5 elementor-widget elementor-widget-text-editor\" data-id=\"82b97d5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"54\" data-end=\"264\">Ensure that all electrical connections are properly made according to the wiring diagram provided in the product manual. Incorrect wiring can lead to malfunction or damage to the actuator. Verify the following:<\/p><ul data-start=\"266\" data-end=\"686\" data-is-last-node=\"\" data-is-only-node=\"\"><li class=\"\" data-start=\"266\" data-end=\"347\"><p class=\"\" data-start=\"268\" data-end=\"347\">The power supply connections are properly secured and there are no loose wires.<\/p><\/li><li class=\"\" data-start=\"348\" data-end=\"455\"><p class=\"\" data-start=\"350\" data-end=\"455\">The control signal wiring is correctly connected, ensuring polarity and signal type are properly matched.<\/p><\/li><li class=\"\" data-start=\"456\" data-end=\"548\"><p class=\"\" data-start=\"458\" data-end=\"548\">The ground connection (if applicable) is properly established to avoid electrical hazards.<\/p><\/li><li class=\"\" data-start=\"549\" data-end=\"686\"><p class=\"\" data-start=\"551\" data-end=\"686\">Double-check the connection of any external components, such as limit switches or feedback devices, to ensure they are wired correctly.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-afb9d5d elementor-widget elementor-widget-template\" data-id=\"afb9d5d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"template.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-template\">\n\t\t\t\t\t<div data-elementor-type=\"section\" data-elementor-id=\"10960\" class=\"elementor elementor-10960\" data-elementor-post-type=\"elementor_library\">\n\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-762f764e elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"762f764e\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-66edc8c2\" data-id=\"66edc8c2\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-1c53049 elementor-widget elementor-widget-heading\" data-id=\"1c53049\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">W\u0141. - WY\u0141.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-26762140 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"26762140\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-8ee309f\" data-id=\"8ee309f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3b29c61e elementor-widget elementor-widget-heading\" data-id=\"3b29c61e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">A - Z 2 aktywnymi wyj\u015bciami sygna\u0142u po\u0142o\u017cenia kra\u0144cowego<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f40ad9 elementor-widget elementor-widget-image\" data-id=\"f40ad9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"400\" height=\"341\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-a.webp\" class=\"attachment-full size-full wp-image-10324\" alt=\"\" srcset=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-a.webp 400w, https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-a-300x256.webp 300w, https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-a-14x12.webp 14w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-144c599d elementor-widget elementor-widget-text-editor\" data-id=\"144c599d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Si\u0142ownik steruj\u0105cy do otwierania lub zamykania za pomoc\u0105 K<\/li><li>Wyj\u015bcie terminala kra\u0144cowego po\u0142o\u017cenia OTWARTE\/ZAMKNI\u0118TE wy\u015ble zdarzenie jako aktywny sygna\u0142 220VAC w momencie osi\u0105gni\u0119cia po\u0142o\u017cenia kra\u0144cowego.<\/li><\/ul><p>\u00a0<\/p><p><strong>Szczeg\u00f3\u0142y po\u0142\u0105czenia:<\/strong><\/p><ol><li>Pod\u0142\u0105czenie przewodu neutralnego zasilania AC85-220V do P1.<\/li><li>Prze\u0142\u0105cz lini\u0119 AC85-220V na CLOSE(P2), aby zamkn\u0105\u0107 zaw\u00f3r<\/li><li>Prze\u0142\u0105cz lini\u0119 AC85-220V na pozycj\u0119 OTWARTE (P3), aby otworzy\u0107 zaw\u00f3r.<\/li><li>P5 to zacisk kra\u0144cowego po\u0142o\u017cenia OTWARTE, kt\u00f3ry wyprowadza pr\u0105d zmienny o napi\u0119ciu 220 V, kt\u00f3ry mo\u017cna wykorzysta\u0107 do zasilania lampki sygnalizacyjnej, gdy si\u0142ownik osi\u0105gnie kra\u0144cowe po\u0142o\u017cenie otwarte.<\/li><li>P6 to zacisk kra\u0144cowego po\u0142o\u017cenia OTWARTE, kt\u00f3ry wyprowadza pr\u0105d zmienny o napi\u0119ciu 220 V, kt\u00f3ry mo\u017cna wykorzysta\u0107 do zasilania lampki sygnalizacyjnej, gdy si\u0142ownik osi\u0105gnie po\u0142o\u017cenie kra\u0144cowe zamkni\u0119cia.<\/li><li>Pod\u0142\u0105cz uziemienie do P7.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-b6785ff\" data-id=\"b6785ff\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3d9195a5 elementor-widget elementor-widget-heading\" data-id=\"3d9195a5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">B - Z 2 pasywnymi wy\u0142\u0105cznikami kra\u0144cowymi<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2f01f91f elementor-widget elementor-widget-image\" data-id=\"2f01f91f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"348\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-b.webp\" class=\"attachment-full size-full wp-image-10325\" alt=\"\" srcset=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-b.webp 400w, https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-b-300x261.webp 300w, https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-b-14x12.webp 14w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7b2fa9cc elementor-widget elementor-widget-text-editor\" data-id=\"7b2fa9cc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Si\u0142ownik steruj\u0105cy do otwierania lub zamykania za pomoc\u0105 K<\/li><li>Wyj\u015bcie terminala kra\u0144cowego po\u0142o\u017cenia OTWARTE\/ZAMKNI\u0118TE wy\u015ble zdarzenie jako sygna\u0142 pasywny po osi\u0105gni\u0119ciu po\u0142o\u017cenia kra\u0144cowego.<\/li><\/ul><p>\u00a0<\/p><p><strong>Szczeg\u00f3\u0142y po\u0142\u0105czenia:<\/strong><\/p><ol><li>Pod\u0142\u0105czenie przewodu neutralnego zasilania AC85-220V do P1.<\/li><li>Prze\u0142\u0105cz lini\u0119 AC85-220V na CLOSE(P2), aby zamkn\u0105\u0107 zaw\u00f3r<\/li><li>Prze\u0142\u0105cz lini\u0119 AC85-220V na pozycj\u0119 OTWARTE (P3), aby otworzy\u0107 zaw\u00f3r.<\/li><li>P4 to z\u0142\u0105cze COM dla sygna\u0142u pasywnego styku po\u0142o\u017cenia kra\u0144cowego OTWARTY\/ZAMKNI\u0118TY, kt\u00f3re normalnie jest pod\u0142\u0105czone do sygna\u0142u GND.<\/li><li>P5 to zacisk kra\u0144cowego po\u0142o\u017cenia OTWARTE, kt\u00f3ry zostanie pod\u0142\u0105czony do COM, gdy si\u0142ownik osi\u0105gnie kra\u0144cowe po\u0142o\u017cenie otwarte.<\/li><li>P6 to zacisk po\u0142o\u017cenia kra\u0144cowego ZAMKNI\u0118CIA, kt\u00f3ry zostanie pod\u0142\u0105czony do COM, gdy si\u0142ownik osi\u0105gnie po\u0142o\u017cenie kra\u0144cowe zamkni\u0119cia.<\/li><li>Pod\u0142\u0105cz uziemienie do P7.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-7c261b3e elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"7c261b3e\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-571c4654\" data-id=\"571c4654\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-796cfd57 elementor-widget elementor-widget-heading\" data-id=\"796cfd57\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">G - Silnik pr\u0105du sta\u0142ego z 2 wy\u0142\u0105cznikami kra\u0144cowymi<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-485d11ef elementor-widget elementor-widget-image\" data-id=\"485d11ef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"391\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-g.webp\" class=\"attachment-full size-full wp-image-10326\" alt=\"\" srcset=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-g.webp 400w, https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-g-300x293.webp 300w, https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-g-12x12.webp 12w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6dea83a0 elementor-widget elementor-widget-text-editor\" data-id=\"6dea83a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Si\u0142ownik steruj\u0105cy do otwierania lub zamykania za pomoc\u0105 kierunku zasilania pomi\u0119dzy zaciskami 1 i 2<\/li><li>Wyj\u015bcie terminala kra\u0144cowego po\u0142o\u017cenia OTWARTE\/ZAMKNI\u0118TE wy\u015ble zdarzenie jako sygna\u0142 pasywny po osi\u0105gni\u0119ciu po\u0142o\u017cenia kra\u0144cowego.<\/li><\/ul><p>\u00a0<\/p><p><strong>Szczeg\u00f3\u0142y po\u0142\u0105czenia:<\/strong><\/p><ol><li>Pod\u0142\u0105cz DC24V+ do P1 i DC24V- do P2, aby zamkn\u0105\u0107 zaw\u00f3r.<\/li><li>Pod\u0142\u0105cz DC24V+ do P2 i DC24V- do P1, aby zamkn\u0105\u0107 zaw\u00f3r.<\/li><li>P3 to COM dla sygna\u0142u pasywnego styku po\u0142o\u017cenia kra\u0144cowego OTWARTY\/ZAMKNI\u0118TY, kt\u00f3ry normalnie jest pod\u0142\u0105czony do sygna\u0142u GND.<\/li><li>P4 to zacisk kra\u0144cowego po\u0142o\u017cenia OTWARTE, kt\u00f3ry zostanie pod\u0142\u0105czony do COM, gdy si\u0142ownik osi\u0105gnie kra\u0144cowe po\u0142o\u017cenie otwarte.<\/li><li>P5 to zacisk po\u0142o\u017cenia kra\u0144cowego ZAMKNI\u0118CIA, kt\u00f3ry zostanie pod\u0142\u0105czony do COM, gdy si\u0142ownik osi\u0105gnie po\u0142o\u017cenie kra\u0144cowe zamkni\u0119cia.<\/li><li>Pod\u0142\u0105cz uziemienie do P7.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-2c13c7d1\" data-id=\"2c13c7d1\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5c3c94ac elementor-widget elementor-widget-heading\" data-id=\"5c3c94ac\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">H - Silnik 3-fazowy 380VAC z 2 wy\u0142\u0105cznikami kra\u0144cowymi<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-643529de elementor-widget elementor-widget-image\" data-id=\"643529de\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"412\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-h.webp\" class=\"attachment-full size-full wp-image-10327\" alt=\"\" srcset=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-h.webp 400w, https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-h-291x300.webp 291w, https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-h-12x12.webp 12w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-13a7de73 elementor-widget elementor-widget-text-editor\" data-id=\"13a7de73\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Si\u0142ownik steruj\u0105cy otwieraniem lub zamykaniem za pomoc\u0105 zewn\u0119trznego falownika w celu zmiany fazy zasilania.<\/li><li>Wyj\u015bcie terminala kra\u0144cowego po\u0142o\u017cenia OTWARTE\/ZAMKNI\u0118TE wy\u015ble zdarzenie jako sygna\u0142 pasywny po osi\u0105gni\u0119ciu po\u0142o\u017cenia kra\u0144cowego.<\/li><\/ul><p>\u00a0<\/p><p><strong>Szczeg\u00f3\u0142y po\u0142\u0105czenia:<\/strong><\/p><ol><li>Pod\u0142\u0105czaj\u0105c wyj\u015bcie falownika 3-fazowego AC380V do P1, P2 i P3, mo\u017cna sterowa\u0107 si\u0142ownikiem, aby otwiera\u0142 lub zamyka\u0142 zaw\u00f3r, zmieniaj\u0105c kolejno\u015b\u0107 3 faz.<\/li><li>Pod\u0142\u0105czenie przewodu neutralnego AC380V do N(P4).<\/li><li>Zacisk P5 s\u0142u\u017cy do wsp\u00f3\u0142pracy z zewn\u0119trznym prze\u0142\u0105cznikiem w celu sterowania kolejno\u015bci\u0105 faz falownika. Zacisk ten jest pod\u0142\u0105czony do zacisku N(P4), gdy si\u0142ownik nie znajduje si\u0119 w pozycji kra\u0144cowej ZAMKNI\u0118CIA, i od\u0142\u0105czony od zacisku N(P4) po osi\u0105gni\u0119ciu przez si\u0142ownik pozycji kra\u0144cowej ZAMKNI\u0118CIA.<\/li><li>Zacisk P6 s\u0142u\u017cy do wsp\u00f3\u0142pracy z zewn\u0119trznym prze\u0142\u0105cznikiem w celu sterowania kolejno\u015bci\u0105 faz falownika. Zacisk ten jest pod\u0142\u0105czony do zacisku N(P4), gdy si\u0142ownik nie znajduje si\u0119 w pozycji kra\u0144cowej OTWARTE, i od\u0142\u0105czony od zacisku N(P4) po osi\u0105gni\u0119ciu przez si\u0142ownik pozycji kra\u0144cowej OTWARTE.<\/li><li>P7 to COM dla sygna\u0142u pasywnego styku po\u0142o\u017cenia kra\u0144cowego OTWARTY\/ZAMKNI\u0118TY, kt\u00f3ry normalnie jest pod\u0142\u0105czony do sygna\u0142u GND.<\/li><li>P8 to zacisk kra\u0144cowego po\u0142o\u017cenia OTWARTE, kt\u00f3ry zostanie pod\u0142\u0105czony do COM, gdy si\u0142ownik osi\u0105gnie kra\u0144cowe po\u0142o\u017cenie otwarte.<\/li><li>P9 to zacisk po\u0142o\u017cenia kra\u0144cowego ZAMKNI\u0118CIA, kt\u00f3ry zostanie pod\u0142\u0105czony do COM, gdy si\u0142ownik osi\u0105gnie po\u0142o\u017cenie kra\u0144cowe zamkni\u0119cia.<\/li><li>Pod\u0142\u0105cz uziemienie do P12.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-3f4fac5b elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"3f4fac5b\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-60aed2ac\" data-id=\"60aed2ac\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3bd28765 elementor-widget elementor-widget-heading\" data-id=\"3bd28765\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Inching i pozycjonowanie<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-8848769 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"8848769\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-33 elementor-top-column elementor-element elementor-element-1c17c3e\" data-id=\"1c17c3e\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-35fbead8 elementor-widget elementor-widget-heading\" data-id=\"35fbead8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">F - Z jednostk\u0105 pozycjonuj\u0105c\u0105<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1ac5eaa3 elementor-widget elementor-widget-image\" data-id=\"1ac5eaa3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"316\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-f.webp\" class=\"attachment-full size-full wp-image-10321\" alt=\"\" srcset=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-f.webp 400w, https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-f-300x237.webp 300w, https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-f-15x12.webp 15w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80dac2d elementor-widget elementor-widget-text-editor\" data-id=\"80dac2d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Si\u0142ownik steruj\u0105cy do otwierania lub zamykania za pomoc\u0105 K<\/li><li>Informacje o po\u0142o\u017ceniu zaworu w czasie rzeczywistym b\u0119d\u0105 wysy\u0142ane jako sygna\u0142 4-20 mA.<\/li><\/ul><p>\u00a0<\/p><p><strong>Szczeg\u00f3\u0142y po\u0142\u0105czenia:<\/strong><\/p><ol><li>Pod\u0142\u0105czenie przewodu zasilaj\u0105cego AC85-220V do L i przewodu neutralnego do N.<\/li><li>Prze\u0142\u0105cz lini\u0119 AC85-220V na CLOSE(P2), aby zamkn\u0105\u0107 zaw\u00f3r.<\/li><li>Prze\u0142\u0105cz lini\u0119 AC85-220V na pozycj\u0119 OTWARTE (P3), aby otworzy\u0107 zaw\u00f3r.<\/li><li>Pod\u0142\u0105czenie wyj\u015bcia -\/+ do systemu w celu wysy\u0142ania pozycji zaworu w czasie rzeczywistym.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-33 elementor-top-column elementor-element elementor-element-48cb89dd\" data-id=\"48cb89dd\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-82392c9 elementor-widget elementor-widget-heading\" data-id=\"82392c9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">C - Z potencjometrem 1K\u03a9\/500\u03a9<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7d24d552 elementor-widget elementor-widget-image\" data-id=\"7d24d552\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"380\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-c.webp\" class=\"attachment-full size-full wp-image-10322\" alt=\"\" srcset=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-c.webp 400w, https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-c-300x285.webp 300w, https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-c-13x12.webp 13w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-11e65789 elementor-widget elementor-widget-text-editor\" data-id=\"11e65789\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Si\u0142ownik steruj\u0105cy do otwierania lub zamykania za pomoc\u0105 K<\/li><li>Pozycja zaworu w czasie rzeczywistym b\u0119dzie wysy\u0142ana jako warto\u015b\u0107 rezystancji potencjometru<\/li><\/ul><p>\u00a0<\/p><p><strong>Szczeg\u00f3\u0142y po\u0142\u0105czenia:<\/strong><\/p><ol><li>Pod\u0142\u0105czenie przewodu neutralnego zasilania AC85-220V do P1.<\/li><li>Prze\u0142\u0105cz lini\u0119 AC85-220V na CLOSE(P2), aby zamkn\u0105\u0107 zaw\u00f3r<\/li><li>Prze\u0142\u0105cz lini\u0119 AC85-220V na pozycj\u0119 OTWARTE (P3), aby otworzy\u0107 zaw\u00f3r.<\/li><li>P4 to dolna strona potencjometru, kt\u00f3ra zwykle jest pod\u0142\u0105czona do sygna\u0142u GND.<\/li><li>Pod\u0142\u0105czenie sygna\u0142u wej\u015bciowego uk\u0142adu sterowania do P5. Warto\u015b\u0107 rezystancji mi\u0119dzy P4 i P5 b\u0119dzie ros\u0142a w miar\u0119 otwierania zaworu przez si\u0142ownik, natomiast warto\u015b\u0107 rezystancji mi\u0119dzy P5 i P6 b\u0119dzie male\u0107.<\/li><li>P6 to g\u00f3rna cz\u0119\u015b\u0107 potencjometru, kt\u00f3ra zwykle jest pod\u0142\u0105czona do zasilania sygna\u0142u.<\/li><li>Pod\u0142\u0105cz uziemienie do P7.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-33 elementor-top-column elementor-element elementor-element-2eb5f8cd\" data-id=\"2eb5f8cd\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-704d6f35 elementor-widget elementor-widget-heading\" data-id=\"704d6f35\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">D - Z potencjometrem i sprz\u0119\u017ceniem zwrotnym po\u0142o\u017cenia ko\u0144cowego<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-65ba6b3f elementor-widget elementor-widget-image\" data-id=\"65ba6b3f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"437\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-d.webp\" class=\"attachment-full size-full wp-image-10323\" alt=\"\" srcset=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-d.webp 400w, https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-d-275x300.webp 275w, https:\/\/dclcontrols.com\/wp-content\/uploads\/2025\/02\/dcl-actuator-interface-diagram-d-11x12.webp 11w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-64fc0e34 elementor-widget elementor-widget-text-editor\" data-id=\"64fc0e34\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Si\u0142ownik steruj\u0105cy do otwierania lub zamykania za pomoc\u0105 K<\/li><li>Pozycja zaworu w czasie rzeczywistym b\u0119dzie wysy\u0142ana jako warto\u015b\u0107 rezystancji potencjometru<\/li><li>Wyj\u015bcie terminala kra\u0144cowego po\u0142o\u017cenia OTWARTE\/ZAMKNI\u0118TE wy\u015ble zdarzenie jako sygna\u0142 pasywny po osi\u0105gni\u0119ciu po\u0142o\u017cenia kra\u0144cowego.<\/li><\/ul><p>\u00a0<\/p><p><strong>Szczeg\u00f3\u0142y po\u0142\u0105czenia:<\/strong><\/p><ol><li>Pod\u0142\u0105czenie przewodu neutralnego zasilania AC85-220V do P1.<\/li><li>Prze\u0142\u0105cz lini\u0119 AC85-220V na CLOSE(P2), aby zamkn\u0105\u0107 zaw\u00f3r<\/li><li>Prze\u0142\u0105cz lini\u0119 AC85-220V na pozycj\u0119 OTWARTE (P3), aby otworzy\u0107 zaw\u00f3r.<\/li><li>P4 to z\u0142\u0105cze COM dla sygna\u0142u pasywnego styku po\u0142o\u017cenia kra\u0144cowego OTWARTY\/ZAMKNI\u0118TY, kt\u00f3re normalnie jest pod\u0142\u0105czone do sygna\u0142u GND.<\/li><li>P5 to zacisk kra\u0144cowego po\u0142o\u017cenia OTWARTE, kt\u00f3ry zostanie pod\u0142\u0105czony do COM, gdy si\u0142ownik osi\u0105gnie kra\u0144cowe po\u0142o\u017cenie otwarte.<\/li><li>P6 to zacisk po\u0142o\u017cenia kra\u0144cowego ZAMKNI\u0118CIA, kt\u00f3ry zostanie pod\u0142\u0105czony do COM, gdy si\u0142ownik osi\u0105gnie po\u0142o\u017cenie kra\u0144cowe zamkni\u0119cia.<\/li><li>P7 to dolna strona potencjometru, kt\u00f3ra normalnie jest pod\u0142\u0105czona do sygna\u0142u GND.<\/li><li>Pod\u0142\u0105czenie sygna\u0142u wej\u015bciowego uk\u0142adu sterowania do P8. Warto\u015b\u0107 rezystancji mi\u0119dzy P7 i P8 b\u0119dzie ros\u0142a w miar\u0119 otwierania zaworu przez si\u0142ownik, natomiast warto\u015b\u0107 rezystancji mi\u0119dzy P8 i P9 b\u0119dzie male\u0107.<\/li><li>P9 to g\u00f3rna cz\u0119\u015b\u0107 potencjometru, kt\u00f3ra zwykle jest pod\u0142\u0105czona do zasilania sygna\u0142u.<\/li><li>Pod\u0142\u0105cz uziemienie do P12.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-472b66b9 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"472b66b9\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-1cfb59fd\" data-id=\"1cfb59fd\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7a09a4a6 elementor-widget elementor-widget-text-editor\" data-id=\"7a09a4a6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Uwaga\uff1a<\/p><ul><li>Obw\u00f3d wewn\u0105trz przerywanej ramki to wewn\u0119trzny obw\u00f3d si\u0142ownika. Natomiast obw\u00f3d na zewn\u0105trz to demonstracja po\u0142\u0105czenia elektrycznego do korzystania z si\u0142ownika.<\/li><li>Je\u015bli masz inne specyficzne wymagania dotycz\u0105ce obwodu po\u0142\u0105czeniowego, skontaktuj si\u0119 z naszym dzia\u0142em pomocy technicznej.\u00a0<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Niniejszy przewodnik dotyczy si\u0142ownik\u00f3w typu prze\u0142\u0105cznikowego z serii DCL przeciwwybuchowych, standardowej i szybkootwieralnych. Dost\u0119pne modele: Si\u0142ownik odporny na warunki atmosferyczne: DCL-05, DCL-10, DCL-20, DCL-40, DCL-60, DCL-100, DCL-160, DCL-250 Si\u0142ownik przeciwwybuchowy: DCL-Ex05, DCL-Ex10, DCL-Ex20, DCL-Ex40, DCL-Ex60 Si\u0142ownik szybkoobrotowy: DCL-K05, DCL-K10, DCL-K20, DCL-K40, DCL-K100 Typowe usterki i metody rozwi\u0105zywania problem\u00f3w Usterka Mo\u017cliwe przyczyny Metody rozwi\u0105zywania problem\u00f3w [\u2026]<\/p>","protected":false},"author":1,"featured_media":10962,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[103],"tags":[53],"class_list":["post-6032","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-mr-actuator","tag-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/pl_pl\/wp-json\/wp\/v2\/posts\/6032","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/pl_pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/pl_pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/pl_pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/pl_pl\/wp-json\/wp\/v2\/comments?post=6032"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/pl_pl\/wp-json\/wp\/v2\/posts\/6032\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/pl_pl\/wp-json\/wp\/v2\/media\/10962"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/pl_pl\/wp-json\/wp\/v2\/media?parent=6032"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/pl_pl\/wp-json\/wp\/v2\/categories?post=6032"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/pl_pl\/wp-json\/wp\/v2\/tags?post=6032"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}