{"id":9257,"date":"2024-07-05T15:43:31","date_gmt":"2024-07-05T07:43:31","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=9257"},"modified":"2025-03-31T06:18:52","modified_gmt":"2025-03-31T06:18:52","slug":"dc-fb3","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/nl_nl\/ondersteuning\/um-actuator\/dc-fb3","title":{"rendered":"DC-FB3 Gebruikershandleiding"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"9257\" class=\"elementor elementor-9257\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-342a362 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"342a362\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-aaa43ff\" data-id=\"aaa43ff\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-41c310b elementor-widget elementor-widget-text-editor\" data-id=\"41c310b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>De DC-FB3-module maakt, wanneer deze in de DCL-elektrische actuator is ge\u00efnstalleerd, het mogelijk om de positie van de klep te regelen met behulp van Modbus-TCP\/IP. De installatie wordt hieronder weergegeven:<\/p><figure style=\"width: 351px\" class=\"wp-caption alignnone\"><img fetchpriority=\"high\" decoding=\"async\" src=\"\/dam\/um\/images\/\/dc-fb3.webp\" alt=\"\" width=\"351\" height=\"406\" \/><figcaption class=\"wp-caption-text\">DC-FB3<\/figcaption><\/figure><h4>\u00a0<\/h4><figure style=\"width: 446px\" class=\"wp-caption alignnone\"><img decoding=\"async\" class=\"\" src=\"\/dam\/um\/images\/dcl-actuator-with-dc-fb3-scaled.webp\" alt=\"\" width=\"446\" height=\"559\" \/><figcaption class=\"wp-caption-text\">DC-FB3 ge\u00efnstalleerd in de DCL-actuator<\/figcaption><\/figure><h2><strong>1. Het aansturen van een DCL-elektrische actuator via Modbus-TCP\/IP met behulp van standaardparameters<\/strong><\/h2><p>De DC-FB3 is vooraf geconfigureerd in clientmodus. Met behulp van de standaard MAC-, IP-, gateway-, server- en poortparameters kunt u de DCL-elektrische actuator aansturen via Modbus-TCP\/IP. De standaardparameters worden aangegeven in het blauwe kader in de onderstaande afbeelding.<\/p><p>Bij gebruik van de standaardparameters kunt u stap 2 overslaan en direct doorgaan naar stap 3, waarbij u Modbus-TCP\/IP gebruikt om de DCL-elektrische actuator te besturen.<\/p><figure style=\"width: 500px\" class=\"wp-caption alignnone\"><img decoding=\"async\" class=\"\" src=\"\/dam\/um\/images\/dcl-actuator-with-dc-fb3-flag-scaled.webp\" alt=\"\" width=\"500\" height=\"627\" \/><figcaption class=\"wp-caption-text\">DCL Modbus TCP\/IP-actuator<\/figcaption><\/figure><h2><strong>2. TCP\/IP-netwerkparameters wijzigen<\/strong><\/h2><h3><strong>2.1 Verbind DC-FB3 met de pc via DC-FB1 (USB naar RS485)<\/strong><\/h3><figure style=\"width: 500px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"\/dam\/um\/images\/\/connect-dc-fb3-to-pc.webp\" alt=\"\" width=\"500\" height=\"374\" \/><figcaption class=\"wp-caption-text\">DCL-actuator via Modbus TCP\/IP met computer verbinden<\/figcaption><\/figure><p>De bedrading voor het aansluiten van de DC-FB3 is als volgt:<\/p><ul><li><p><strong>Rode doos 1<\/strong>: Aansluiten op een 220V wisselstroomvoeding.<\/p><\/li><li><p><strong>Groene doos 4<\/strong>: Maak verbinding met de RS485-interface (A\/B) van DC-FB1.<\/p><\/li><li><p><strong>DC-FB1 USB<\/strong>: Sluit hem aan op de pc.<\/p><\/li><\/ul><p>Raadpleeg voor meer informatie de gebruikershandleiding van de DC-FB1.<\/p><h5>\u00a0<\/h5><h3><strong>2.2 Gebruik configuratiesoftware op de pc om netwerkparameters in te stellen<\/strong><\/h3><p><strong>Configuratiesoftware downloaden<\/strong>Installeer de benodigde configuratiesoftware om de netwerkparameters in te stellen.<\/p><p><strong>Selecteer de juiste poort<\/strong>Open de configuratiesoftware, kies de juiste poort en klik <strong>VERBINDEN<\/strong> om verbinding te maken met DC-FB3.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/um\/images\/\/dc-fb3-config3.webp\" width=\"681\" height=\"473\" \/><\/p><p>Zodra de verbinding tot stand is gebracht, leest de configuratiesoftware automatisch de parameters van de DC-FB3 uit.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/um\/images\/\/dc-fb3-config2.webp\" width=\"676\" height=\"467\" \/><\/p><p><strong>Netwerkparameters wijzigen<\/strong>: Nadat u de netwerkparameters hebt gewijzigd, klikt u <strong>REDDEN<\/strong> om de bijgewerkte parameters in de DC-FB3 op te slaan.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/um\/images\/\/dc-fb3-config1.webp\" width=\"677\" height=\"472\" \/><\/p><h2><strong>3. Bedien de DCL-actuator via Modbus-TCP\/IP<\/strong><\/h2><h3><strong>Hardware-aansluitingen<\/strong><\/h3><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" src=\"\/dam\/um\/images\/dcl-actuator-with-dc-fb3-flag-scaled.webp\" width=\"500\" height=\"627\" \/><\/p><ul><li>Sluit de 220V AC-voeding aan op de klemmen die met rood vak 1 zijn gemarkeerd.<\/li><li>Steek de RJ45-stekker in de aansluiting die is gemarkeerd met het gele vakje 2.<\/li><\/ul><p>Nu kunt u de actuator aansturen via Modbus-RTU-commando&#039;s, zoals hieronder beschreven. <a href=\"\/nl_nl\/ondersteuning\/um-actuator\/um-sf-zc-modbus\/\">DCL Actuator Modbus Toepassingshandleiding<\/a><\/p><p><a href=\"\/nl_nl\/ondersteuning\/um-actuator\/um-sf-zc-modbus\/\">Meer leren<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4060921 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"4060921\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-78394cd\" data-id=\"78394cd\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4f45092 elementor-widget elementor-widget-text-editor\" data-id=\"4f45092\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"\/nl_nl\/content\/dam\/downloads\/app\/DLC_DC-FB3-v1.17.zip\/\" target=\"_blank\" rel=\"noopener\"><span style=\"text-decoration: underline;\">Download de installatiesoftware<\/span><\/a><\/p><p><a href=\"\/nl_nl\/um\/dc-fb1\/\" target=\"_blank\" rel=\"noopener\"><span style=\"text-decoration: underline;\">Bekijk de gebruiksaanwijzing van de DC-FB1.<\/span><\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>The DC-FB3 module, when installed in the DCL electric actuator, allows for controlling the valve&#8217;s position using Modbus-TCP\/IP. The installation is shown below: \u00a0 1. Controlling DCL Electric Actuator via Modbus-TCP\/IP Using Default Parameters The DC-FB3 is pre-configured in Client mode. Using the default MAC, IP, Gateway, Server, and Port parameters, you can control the [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[9],"tags":[],"class_list":["post-9257","post","type-post","status-publish","format-standard","hentry","category-um-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/nl_nl\/wp-json\/wp\/v2\/posts\/9257","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/nl_nl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/nl_nl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/nl_nl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/nl_nl\/wp-json\/wp\/v2\/comments?post=9257"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/nl_nl\/wp-json\/wp\/v2\/posts\/9257\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/nl_nl\/wp-json\/wp\/v2\/media?parent=9257"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/nl_nl\/wp-json\/wp\/v2\/categories?post=9257"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/nl_nl\/wp-json\/wp\/v2\/tags?post=9257"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}