{"id":4284,"date":"2023-04-23T20:40:31","date_gmt":"2023-04-23T12:40:31","guid":{"rendered":"http:\/\/www.dcl-controls.com\/?p=4284"},"modified":"2025-03-31T09:27:20","modified_gmt":"2025-03-31T09:27:20","slug":"why-explosion-proof-actuator","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/nl_nl\/ondersteuning\/een-actuator\/waarom-een-explosieveilige-actuator","title":{"rendered":"Waarom hebben sommige actuatoren explosiebeveiliging nodig?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"4284\" class=\"elementor elementor-4284\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-ef26768 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"ef26768\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-cb6e5dd\" data-id=\"cb6e5dd\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a724f46 elementor-widget elementor-widget-text-editor\" data-id=\"a724f46\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0<\/p><h2><strong>1. Wat is een explosie?<\/strong><\/h2><p>Een explosie vindt plaats wanneer <strong>Brandbare stoffen mengen zich met zuurstof.<\/strong> en onder bepaalde omstandigheden ontbranden. Als de <strong>De reactiesnelheid is hoger dan de geluidssnelheid.<\/strong>, dit resulteert in een <strong>vernietigende explosiegolf<\/strong>.<\/p><hr \/><h2><strong>2. Wat is explosiebeveiliging?<\/strong><\/h2><p>Naar <strong>explosies voorkomen<\/strong>Ten minste \u00e9\u00e9n van de drie belangrijkste factoren moet onder controle zijn:<\/p><ol><li><p><strong>Brandbare stoffen<\/strong><\/p><\/li><li><p><strong>Zuurstof<\/strong><\/p><\/li><li><p><strong>Ontstekingsbron<\/strong><\/p><\/li><\/ol><p>Sinds <strong>Brandbare stoffen en zuurstof zijn vaak onvermijdelijk.<\/strong> in industri\u00eble omgevingen, de <strong>De ontstekingsbron moet onder controle worden gehouden.<\/strong>.<\/p><p>Elektrische apparatuur is een <strong>potenti\u00eble ontstekingsbron<\/strong> vanwege:<br \/>\u2714 <strong>Oppervlakteverwarming tijdens gebruik<\/strong><br \/>\u2714 <strong>Elektrostatische ontlading<\/strong><br \/>\u2714 <strong>Vonken van elektrische stroom<\/strong><\/p><p>Explosieveilige elektrische apparatuur is <strong>Ontworpen om overmatige oppervlaktetemperaturen en elektrische vonken te voorkomen.<\/strong>waardoor ervoor gezorgd wordt dat het <strong>wordt geen ontstekingsbron<\/strong>.<\/p><p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/faq\/actuator\/why-select-a-explosion-proof-actuator\/images\/dcl-explosion-3-factors.webp\" width=\"1033\" height=\"620\" \/><\/p><hr \/><h2><strong>3. Classificatie van gevaarlijke omgevingen<\/strong><\/h2><p>Explosieveilige elektrische apparatuur wordt in twee categorie\u00ebn ingedeeld:<\/p><ul><li><p><strong>Categorie I<\/strong>: Uitrusting voor <strong>kolenmijnen<\/strong><\/p><\/li><li><p><strong>Categorie II<\/strong>: Uitrusting voor <strong>andere explosieve gasomgevingen<\/strong><\/p><\/li><\/ul><h3><strong>Categorie II-apparatuur<\/strong><\/h3><ol><li><p><strong>Explosiegroepen (gebaseerd op veiligheidsafstand en ontstekingsstroom)<\/strong><\/p><ul><li><p><strong>IIA<\/strong><\/p><\/li><li><p><strong>IIB<\/strong> (kan worden gebruikt onder IIA-omstandigheden)<\/p><\/li><li><p><strong>IIC<\/strong> (kan worden gebruikt bij aandoeningen IIA en IIB)<\/p><\/li><\/ul><\/li><li><p><strong>Temperatuurgroepen (gebaseerd op de maximale oppervlaktetemperatuur)<\/strong><\/p><ul><li><p><strong>T1 (450\u00b0C)<\/strong><\/p><\/li><li><p><strong>T2 (300\u00b0C)<\/strong><\/p><\/li><li><p><strong>T3 (200\u00b0C)<\/strong><\/p><\/li><li><p><strong>T4 (135\u00b0C)<\/strong><\/p><\/li><li><p><strong>T5 (100\u00b0C)<\/strong><\/p><\/li><li><p><strong>T6 (85\u00b0C)<\/strong><\/p><\/li><\/ul><\/li><\/ol><p>Meer dan <strong>90% aan explosieve gassen<\/strong> vallen onder <strong>IIA, IIB groepen<\/strong> En <strong>Temperatuurclassificaties T1\u2013T4<\/strong>.<\/p><p><img decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/faq\/actuator\/why-select-a-explosion-proof-actuator\/images\/dcl-explosion-level.webp\" width=\"1323\" height=\"400\" \/><\/p><hr \/><h2><strong>4. Hoe wordt explosiebeveiliging bereikt?<\/strong><\/h2><p>Er zijn verschillende methoden om ervoor te zorgen dat elektrische apparatuur <strong>veilig voor explosiegevaarlijke omgevingen<\/strong>, zoals gedefinieerd door <strong>GB3836, IEC60079, EN50014<\/strong> normen.<\/p><p><img decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/elementor\/thumbs\/dcl-explosion-no-fire-q66rupb0ie91afmk9gkhl6y0ri81l2banhzo5pk1fo.webp\" width=\"500\" height=\"314\" \/><\/p><h3><strong>Explosieveilig (Exd) ontwerp<\/strong><\/h3><p>DCL explosieveilige actuatoren worden vervaardigd volgens:<br \/>\u2714 <strong>GB3836.1-2010, GB3836.2-2010<\/strong><br \/>\u2714 <strong>IEC 60079-0, IEC 60079-1, IEC 60079-31<\/strong><br \/>\u2714 <strong>ISO\/IEC 80079-36, ISO\/IEC 80079-37<\/strong><\/p><h4><strong>Ontwerpprincipes voor brandwerende (Exd) systemen<\/strong><\/h4><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/faq\/actuator\/why-select-a-explosion-proof-actuator\/images\/dcl-explosion-proof.webp\" width=\"1163\" height=\"661\" \/><\/p><p>\u2714 <strong>Er kan een explosie plaatsvinden in het apparaat.<\/strong>Maar de behuizing voorkomt dat het de externe omgeving ontsteekt.<br \/>\u2714 <strong>Vlamdichte verbindingen<\/strong> zijn ontworpen met de juiste <strong>opening en lengte<\/strong> om interne explosies in te dammen.<br \/>\u2714 <strong>Stevige omheiningen<\/strong> weerstaan <strong>hoge interne druk<\/strong> zonder te breken.<\/p><h3><strong>DCL explosieveilige componenten<\/strong><\/h3><p>\u2714 <strong>Motorcompartiment<\/strong><br \/>\u2714 <strong>Elektrisch componentcompartiment<\/strong><br \/>\u2714 <strong>Bedradingscompartiment<\/strong><\/p><hr \/><h2><strong>5. DCL-certificering voor explosieveilige actuatoren<\/strong><\/h2><h3><strong>Explosiebeveiligingsniveau: Exd IIC T4 Gb<\/strong><\/h3><p>\u2714 <strong>Ex<\/strong> \u2013 Explosieveilige markering<br \/>\u2714 <strong>D<\/strong> \u2013 Vlamvertragend type (\u201cExd\u201d)<br \/>\u2714 <strong>II<\/strong> \u2013 Niet-mijnbouwtoepassingen<br \/>\u2714 <strong>C<\/strong> \u2013 Explosiegroep (hogere veiligheidseisen)<br \/>\u2714 <strong>T4<\/strong> \u2013 Maximale oppervlaktetemperatuur <strong>135\u00b0C<\/strong><br \/>\u2714 <strong>GB<\/strong> \u2013 Beschermingsniveau van de apparatuur<\/p><hr \/><h3><strong>Conclusie<\/strong><\/h3><p>Explosieveilige actuatoren zijn essentieel in <strong>gevaarlijke omgevingen<\/strong> om te voorkomen <strong>ontsteking van explosieve gassen<\/strong>DCL&#039;s <strong>Exd IIC T4 Gb-geclassificeerde actuatoren<\/strong> Zorg voor veiligheid door:<br \/>\u2714 <strong>Bevat interne explosies<\/strong><br \/>\u2714 <strong>Voorkomt vonken en overmatige hitte<\/strong><br \/>\u2714 <strong>Bestand tegen hoge druk zonder te scheuren.<\/strong><\/p><p>Deze ontwerpmaatregelen maken <strong>DCL-actuatoren zijn betrouwbaar en veilig.<\/strong> voor <strong>industri\u00eble toepassingen in explosieve atmosferen<\/strong>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>\u00a0 1. Wat is een explosie? Een explosie vindt plaats wanneer brandbare stoffen zich mengen met zuurstof en onder bepaalde omstandigheden ontbranden. Als de reactiesnelheid de geluidssnelheid overschrijdt, resulteert dit in een destructieve explosiegolf. 2. Wat is explosiebeveiliging? Om explosies te voorkomen, moet ten minste \u00e9\u00e9n van de drie belangrijkste factoren worden beheerst: [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[91],"tags":[53,66,39],"class_list":["post-4284","post","type-post","status-publish","format-standard","hentry","category-an-actuator","tag-actuator","tag-explosion-proof-actuator","tag-faq"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/nl_nl\/wp-json\/wp\/v2\/posts\/4284","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/nl_nl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/nl_nl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/nl_nl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/nl_nl\/wp-json\/wp\/v2\/comments?post=4284"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/nl_nl\/wp-json\/wp\/v2\/posts\/4284\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/nl_nl\/wp-json\/wp\/v2\/media?parent=4284"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/nl_nl\/wp-json\/wp\/v2\/categories?post=4284"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/nl_nl\/wp-json\/wp\/v2\/tags?post=4284"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}