Hoe een DCL-actuator via Modbus te besturen met vaTestTool_DCL.exe

Hoe een DCL-actuator via Modbus te besturen met vaTestTool_DCL.exe

1.Open vaTestTool_DCL-v1.31.exe. 2.The application will popup a “Connect to” dialog to set the target device id and local computer RS232 port parameters as follow. Choose the COM port which connected to the USB-RS485 connector. Select the modbus baud rate (the default baudrate on DCL actuator now is 9600). Click on “CONNECT”button to connect to the […]

Hoe kies je een actuator?

Determining Specific Valve Drive Parameters For precise fluid control applications, it is essential to define the final valve drive parameters based on factors such as fluid pressure, media type, and control method. This ensures that the selected electric actuator meets the operational requirements. The following parameters should be determined before finalizing the actuator model: Choose […]

Gebruikershandleiding voor de DCL-actuator met FSR

DCL Actuator with FSR Operation Panel Connection P1:DC24V Power + P3:DC24V Power – P5:4-20mA Input – P7:4-20mA Input + P9:4-20mA Output – P11:4-20mA Output + P2:ON/OFF Input COM P4:ON/OFF Input Open P6:ON/OFF Input Close P8:ON/OFF Output COM P10:ON/OFF Output Open P12:ON/OFF Output Close Button KO: Used in setting mode. Press this button to open the […]

DCL Actuator Modbus Toepassingshandleiding (Envision-versie)

Service & Support The DCL series actuators support the Modbus-RTU protocol. By referring to this application manual, you can connect the DCL actuator to Modbus. Panel Description   1. Interface Definition P1: 220VAC Neutral (N) P2: 220VAC Live (L) P3: 4-20mA Input – P4: 4-20mA Input + P5: 4-20mA Output – P6: 4-20mA Output + […]

DC-FB3 Gebruikershandleiding

The DC-FB3 module, when installed in the DCL electric actuator, allows for controlling the valve’s position using Modbus-TCP/IP. The installation is shown below:   1. Controlling DCL Electric Actuator via Modbus-TCP/IP Using Default Parameters The DC-FB3 is pre-configured in Client mode. Using the default MAC, IP, Gateway, Server, and Port parameters, you can control the […]

DC-FB1 Gebruikershandleiding

The DC-FB1 is a USB to RS485 converter, enabling communication between a computer and a device using the RS485 protocol. This manual provides the necessary steps to get your DC-FB1 up and running, enabling you to communicate with RS485 devices from your computer. Here’s how to set it up: Connecting DC-FB1 to the Computer 1.Plug […]

JB/T 8219—2016 Standaard voor gewone en intelligente elektrische actuatoren gebruikt in industriële procesbesturingssystemen

Table of Contents Preface 1 Scope 2 Normative References 3 Terms and Definitions 4 Product Classification and Basic Parameters 4.1 Product Classification 4.2 Basic Parameters 5 Basic Functions of Intelligent Actuators 5.1 Display Function 5.2 Parameter Setting Function 5.3 On-Site Configuration Function 5.4 Fault Self-Diagnosis and Alarm Function 5.5 Communication Function 5.6 Other Functions 6 […]

GB/T 3369.1—2008/IEC 60381-1:1982

The standard for the 4-20mA current signal used in electric actuators is as follows: Standard: GB/T 3369.1—2008/IEC 60381-1:1982 Title: Analogue signals for process control systems — Part 1: Direct current signals (IEC 60381-1:1982, IDT) This standard defines the specifications for analog signals, specifically for the use of direct current (DC) signals in process control systems, […]

Offerteaanvraag

Druk nu op "Verzenden". We zullen later het productmodelnummer en de lokale distributeur met u bevestigen en u vervolgens de offerte toesturen.

WhatsApp

Scan de QR-code om direct met onze technicus te chatten...

Offerteaanvraag

Druk nu op "Verzenden". We zullen later het productmodelnummer en de lokale distributeur met u bevestigen en u vervolgens de offerte toesturen.

WhatsApp

Scan de QR-code om direct met onze technicus te chatten...

Offerteaanvraag

Druk nu op "Verzenden". We zullen later het productmodelnummer en de lokale distributeur met u bevestigen en u vervolgens de offerte toesturen.

WhatsApp

Scan de QR-code om direct met onze technicus te chatten...

🤝 Laten we samen jouw merk opbouwen

✅ ODM

  • Uw logo en verpakking
  • Aangepaste uitvoerformaten (4-20mA, RS485 Modbus, HART, enz.)
  • De kleur of het label van de behuizing verandert.
  • Cloud-compatibele versies (optioneel)

✅ OEM

  • Volg strikt uw ontwerp en specificaties op.
  • Volledige vertrouwelijkheid en bescherming van intellectueel eigendom.
  • Hoogwaardige productie tegen een concurrerende prijs.
  • Productie in kleine of grote series
  • 🏭 Interne R&D en productieVan printplaat tot behuizing, alles onder één dak.
  • 💬 Meertalige ondersteuningEngelstalige ingenieurs en verkoopmedewerkers.

  • ⚙️ Flexibele minimale bestelhoeveelheid (MOQ)Ondersteuning voor zowel startups als wereldwijde merken.

  • 🚀 Snel prototypenMonsterlevering binnen 7-10 dagen.

 Neem vandaag nog contact met ons op. Om een productcatalogus aan te vragen of een gratis adviesgesprek te krijgen.

Offerteaanvraag

Verzoek indienen

WhatsApp

Scan de QR-code om direct met onze technicus te chatten...

Neem contact met ons op

Telefoon

(+86) 130 2633 1611

WhatsApp

Ken Bryan

即时客服图标 | Live berichtpictogram

Chat op de site

Klik op het pictogram rechtsonder om met ons te chatten...