{"id":6393,"date":"2023-08-31T19:23:28","date_gmt":"2023-08-31T11:23:28","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6393"},"modified":"2025-03-31T07:02:40","modified_gmt":"2025-03-31T07:02:40","slug":"en15714-2-actuator-duty-classification","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/nb_no\/stotte\/ts-aktuator\/en15714-2-aktuatorens-driftsklassifisering","title":{"rendered":"EN15714-2 Klassifisering av elektrisk aktuatorkontroll (drift)"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6393\" class=\"elementor elementor-6393\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-c4425ee elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"c4425ee\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-592bf2f\" data-id=\"592bf2f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5ac9aa3 elementor-widget elementor-widget-image\" data-id=\"5ac9aa3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"646\" height=\"914\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/08\/en15714-2-en.webp\" class=\"attachment-full size-full wp-image-6403\" alt=\"\u7535\u52a8\u6267\u884c\u5668\u63a7\u5236\u65b9\u5f0f(duty )\u7684\u5206\u7c7b\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2d2988c elementor-widget elementor-widget-text-editor\" data-id=\"2d2988c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2><strong>Kontrollpliktklassifiseringer:<\/strong><\/h2><ul><li><h4><strong>Klasse A: AV-P\u00c5-type (p\u00e5\/av)<\/strong><\/h4><\/li><\/ul><ul><li style=\"list-style-type: none;\"><ul><li><p><strong>Funksjon<\/strong>Aktuatoren er n\u00f8dvendig for \u00e5 drive ventilen gjennom hele slaglengden fra helt \u00e5pen til helt lukket (og omvendt).<\/p><\/li><li><p><strong>Typisk bruk<\/strong>Bruksomr\u00e5der der ventiler enten er helt \u00e5pne eller helt lukket.<\/p><\/li><\/ul><\/li><li><h4><strong>Klasse B: Finjustering\/posisjoneringsjusteringstype<\/strong><\/h4><ul><li><p><strong style=\"font-size: 16px;\">Funksjon<\/strong><span style=\"font-size: 16px;\">Aktuatoren beveger av og til ventilen til en hvilken som helst posisjon (helt \u00e5pen, mellomliggende eller helt lukket).<\/span><\/p><\/li><li><p><strong style=\"font-size: 16px;\">Typisk bruk<\/strong><span style=\"font-size: 16px;\">Bruksomr\u00e5der som krever sporadisk justering, men ikke kontinuerlig bevegelse.<\/span><\/p><\/li><\/ul><\/li><li><h4><strong>Klasse C: Modulerende type<\/strong><\/h4><ul><li><p><strong>Funksjon<\/strong>Aktuatoren beveger ofte ventilen mellom helt \u00e5pen og helt lukket posisjon.<\/p><\/li><li><p><strong>Typisk bruk<\/strong>Applikasjoner som krever kontinuerlig og hyppig modulering av ventilposisjon.<\/p><\/li><\/ul><\/li><li><h4><strong>Klasse D: Kontinuerlig modulerende type<\/strong><\/h4><ul><li><p><strong>Funksjon<\/strong>Aktuatoren beveger ventilen kontinuerlig til en hvilken som helst posisjon mellom helt \u00e5pen og helt lukket.<\/p><\/li><li><p><strong>Typisk bruk<\/strong>Bruksomr\u00e5der med kontinuerlige eller sv\u00e6rt hyppige justeringer.<\/p><\/li><\/ul><\/li><\/ul><hr \/><h2><strong>Krav til aktuatorens livssyklus:<\/strong><\/h2><p>Aktuatorens design m\u00e5 overholde de spesifiserte levetidsstandardene. For modulerende og kontinuerlig modulerende aktuatorer er holdbarheten basert p\u00e5 kontinuerlige starter innenfor 30% av slaglengden.<\/p><h4><strong>Levetidstesting for delsvingaktuatorer:<\/strong><\/h4><table><thead><tr><th>Nominelt dreiemomentomr\u00e5de (Nm)<\/th><th>Klasse A\/B (P\u00c5-AV)<\/th><th>Klasse C (modulerende)<\/th><th>Klasse D (kontinuerlig modulerende)<\/th><\/tr><\/thead><tbody><tr><td>&lt;= 125<\/td><td>10 000 sykluser<\/td><td>1 800 000 sykluser<\/td><td>10 000 000 sykluser<\/td><\/tr><tr><td>126-1000<\/td><td>10 000 sykluser<\/td><td>1 200 000 sykluser<\/td><td>10 000 000 sykluser<\/td><\/tr><tr><td>1001-4000<\/td><td>5000 sykluser<\/td><td>500 000 sykluser<\/td><td>5 000 000 sykluser<\/td><\/tr><tr><td>4001-32000<\/td><td>5000 sykluser<\/td><td>250 000 sykluser<\/td><td>Skal avtales<\/td><\/tr><tr><td>&gt; 32000<\/td><td>1000 sykluser<\/td><td>Skal avtales<\/td><td>Skal avtales<\/td><\/tr><\/tbody><\/table><ul><li><p><strong>Driftssykluser<\/strong>En syklus inkluderer to retninger med 90\u00b0 slaglengde (\u00e5pne 90\u00b0 + lukke 90\u00b0), basert p\u00e5 en gjennomsnittlig belastning p\u00e5 minst 30% nominelt dreiemoment, med minst 5% nominelt dreiemoment i hver ende av slaget.<\/p><\/li><li><p><strong>Oppstartssykluser<\/strong>\u00c9n oppstart inneb\u00e6rer \u00e5 bevege aktuatoren minst 1% av slaglengden med et nominelt dreiemoment p\u00e5 minst 30%.<\/p><\/li><\/ul><hr \/><h4><strong>Levetidstesting for flerturnaktuatorer:<\/strong><\/h4><table><thead><tr><th>Nominelt dreiemomentomr\u00e5de (Nm)<\/th><th>Maks. skyvekraft (kN)<\/th><th>Klasse A\/B (P\u00c5-AV)<\/th><th>Klasse C (modulerende)<\/th><th>Klasse D (kontinuerlig modulerende)<\/th><\/tr><\/thead><tbody><tr><td>&lt;= 100<\/td><td>&lt;= 40<\/td><td>10 000 sykluser<\/td><td>1 800 000 sykluser<\/td><td>10 000 000 sykluser<\/td><\/tr><tr><td>101-700<\/td><td>&lt;= 150<\/td><td>10 000 sykluser<\/td><td>1 200 000 sykluser<\/td><td>10 000 000 sykluser<\/td><\/tr><tr><td>701-2500<\/td><td>&lt;= 325<\/td><td>5000 sykluser<\/td><td>500 000 sykluser<\/td><td>5 000 000 sykluser<\/td><\/tr><tr><td>2501-10000<\/td><td>&lt;= 1100<\/td><td>5000 sykluser<\/td><td>250 000 sykluser<\/td><td>Skal avtales<\/td><\/tr><tr><td>&gt; 10000<\/td><td>&gt; 1100<\/td><td>1000 sykluser<\/td><td>Skal avtales<\/td><td>Skal avtales<\/td><\/tr><\/tbody><\/table><hr \/><h4><strong>Levetidstesting for line\u00e6re aktuatorer:<\/strong><\/h4><table><thead><tr><th>Nominelt skyvekraftomr\u00e5de (kN)<\/th><th>Klasse A\/B (P\u00c5-AV)<\/th><th>Klasse C (modulerende)<\/th><th>Klasse D (kontinuerlig modulerende)<\/th><\/tr><\/thead><tbody><tr><td>&lt;= 20<\/td><td>10 000 sykluser<\/td><td>1 800 000 sykluser<\/td><td>10 000 000 sykluser<\/td><\/tr><tr><td>21-70<\/td><td>10 000 sykluser<\/td><td>1 200 000 sykluser<\/td><td>10 000 000 sykluser<\/td><\/tr><tr><td>71-150<\/td><td>5000 sykluser<\/td><td>500 000 sykluser<\/td><td>5 000 000 sykluser<\/td><\/tr><tr><td>151-325<\/td><td>2500 sykluser<\/td><td>250 000 sykluser<\/td><td>Skal avtales<\/td><\/tr><tr><td>&gt; 325<\/td><td>1000 sykluser<\/td><td>Skal avtales<\/td><td>Skal avtales<\/td><\/tr><\/tbody><\/table><hr \/><h2><strong>Krav til justeringsfrekvens (per time):<\/strong><\/h2><h4><strong>Delvis svingende aktuatorer:<\/strong><\/h4><table><thead><tr><th>Nominelt dreiemomentomr\u00e5de (Nm)<\/th><th>Klasse A (P\u00c5-AV)<\/th><th>Klasse B (P\u00c5-AV)<\/th><th>Klasse C (modulerende)<\/th><th>Klasse D (kontinuerlig modulerende)<\/th><\/tr><\/thead><tbody><tr><td>&lt;= 125<\/td><td>15 sykluser\/time<\/td><td>120 starter\/time<\/td><td>1200 starter\/time<\/td><td>3600 starter\/time<\/td><\/tr><tr><td>126-1000<\/td><td>10 sykluser\/time<\/td><td>60 starter\/time<\/td><td>600 starter\/time<\/td><td>1800 starter\/time<\/td><\/tr><tr><td>1001-4000<\/td><td>5 sykluser\/time<\/td><td>30 starter\/time<\/td><td>300 starter\/time<\/td><td>600 starter\/time<\/td><\/tr><tr><td>4001-32000<\/td><td>5 sykluser\/time<\/td><td>15 starter\/time<\/td><td>60 starter\/time<\/td><td>N.A.<\/td><\/tr><tr><td>&gt; 32000<\/td><td>5 sykluser\/time<\/td><td>5 starter\/time<\/td><td>30 starter\/time<\/td><td>N.A.<\/td><\/tr><\/tbody><\/table><hr \/><h4><strong>Flerturnaktuatorer:<\/strong><\/h4><table><thead><tr><th>Nominelt dreiemomentomr\u00e5de (Nm)<\/th><th>Klasse A (P\u00c5-AV)<\/th><th>Klasse B (P\u00c5-AV)<\/th><th>Klasse C (modulerende)<\/th><th>Klasse D (kontinuerlig modulerende)<\/th><\/tr><\/thead><tbody><tr><td>&lt;= 100<\/td><td>15 minutter\/time<\/td><td>30 starter\/time<\/td><td>1200 starter\/time<\/td><td>3600 starter\/time<\/td><\/tr><tr><td>101-700<\/td><td>15 minutter\/time<\/td><td>20 starter\/time<\/td><td>600 starter\/time<\/td><td>1800 starter\/time<\/td><\/tr><tr><td>701-2500<\/td><td>15 minutter\/time<\/td><td>15 starter\/time<\/td><td>300 starter\/time<\/td><td>600 starter\/time<\/td><\/tr><tr><td>2501-10000<\/td><td>15 minutter\/time<\/td><td>10 starter\/time<\/td><td>60 starter\/time<\/td><td>N.A.<\/td><\/tr><tr><td>&gt; 10000<\/td><td>15 minutter\/time<\/td><td>5 starter\/time<\/td><td>30 starter\/time<\/td><td>N.A.<\/td><\/tr><\/tbody><\/table><hr \/><h4><strong>Line\u00e6re aktuatorer:<\/strong><\/h4><table><thead><tr><th>Nominelt skyvekraftomr\u00e5de (kN)<\/th><th>Klasse A (P\u00c5-AV)<\/th><th>Klasse B (P\u00c5-AV)<\/th><th>Klasse C (modulerende)<\/th><th>Klasse D (kontinuerlig modulerende)<\/th><\/tr><\/thead><tbody><tr><td>&lt;= 20<\/td><td>15 sykluser\/time<\/td><td>30 starter\/time<\/td><td>1200 starter\/time<\/td><td>3600 starter\/time<\/td><\/tr><tr><td>21-70<\/td><td>10 sykluser\/time<\/td><td>15 starter\/time<\/td><td>600 starter\/time<\/td><td>1800 starter\/time<\/td><\/tr><tr><td>&gt; 70<\/td><td>5 sykluser\/time<\/td><td>5 starter\/time<\/td><td>30 starter\/time<\/td><td>TBA<\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-192baa1 elementor-widget elementor-widget-text-editor\" data-id=\"192baa1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Relevante standarder:<\/p><p><em>EN15714-1<\/em><\/p><p><em>EN 12570 \uff0c Industriventiler - Metode for bestemmelse av st\u00f8rrelse p\u00e5 betjeningselement<\/em><br \/><em>EN 60529\uff0c\u5916\u58f3\u9632\u62a4\u7b49\u7ea7\uff08IP\u4ee3\u7801\uff09\uff08IEC 60529:1989\uff09<\/em><br \/><em>EN ISO 5210:1996\uff0c\u5de5\u4e1a\u9600\u95e8--\u591a\u56de\u8f6c\u9600\u95e8\u6267\u884c\u673a\u6784\u9644\u4ef6\uff081SO 5210:1991\uff09<\/em><br \/><em>EN ISO 5211\uff0c\u5de5\u4e1a\u9600\u95e8-\u90e8\u5206\u56de\u8f6c\u9600\u95e8\u6267\u884c\u673a\u6784\u9644\u4ef6\uff08ISO 5211-2001\uff09<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Kontrollpliktklassifiseringer: Klasse A: P\u00c5-AV Type (P\u00e5\/Av) Funksjon: Aktuatoren er p\u00e5lagt \u00e5 drive ventilen gjennom hele slaglengden fra helt \u00e5pen til helt lukket (og omvendt). Typisk bruk: Bruksomr\u00e5der der ventiler enten er helt \u00e5pne eller helt lukket. Klasse B: Finjustering\/posisjoneringsjustering Type Funksjon: Aktuatoren beveger av og til ventilen til [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[3],"tags":[53,66,57,52,55,65],"class_list":["post-6393","post","type-post","status-publish","format-standard","hentry","category-ts-actuator","tag-actuator","tag-explosion-proof-actuator","tag-general-actuator","tag-fast-move-actuator","tag-tech-ref","tag-very-small-actuator-tag"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/nb_no\/wp-json\/wp\/v2\/posts\/6393","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/nb_no\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/nb_no\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/nb_no\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/nb_no\/wp-json\/wp\/v2\/comments?post=6393"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/nb_no\/wp-json\/wp\/v2\/posts\/6393\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/nb_no\/wp-json\/wp\/v2\/media?parent=6393"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/nb_no\/wp-json\/wp\/v2\/categories?post=6393"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/nb_no\/wp-json\/wp\/v2\/tags?post=6393"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}