{"id":6034,"date":"2023-08-03T20:40:54","date_gmt":"2023-08-03T12:40:54","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6034"},"modified":"2025-03-27T09:36:11","modified_gmt":"2025-03-27T09:36:11","slug":"dcl-02-modulating-actuator","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/nb_no\/stotte\/herr-aktuator\/dcl-02-modulerende-aktuator","title":{"rendered":"Vanlige feil og feils\u00f8king for DCL-02 modulerende aktuatorer"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6034\" class=\"elementor elementor-6034\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4d0a73a e-con-full e-flex e-con e-parent\" data-id=\"4d0a73a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-074db40 e-con-full e-flex e-con e-child\" data-id=\"074db40\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c0eba31 elementor-widget elementor-widget-text-editor\" data-id=\"c0eba31\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Denne veiledningen gjelder for DCL ultrasm\u00e5 modulerende aktuatorer, modell som f\u00f8lger:<\/p><p>DCL-02E<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-baf5aaf elementor-widget elementor-widget-image\" data-id=\"baf5aaf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-02-valve.webp\" title=\"\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b4622d9 elementor-widget elementor-widget-heading\" data-id=\"b4622d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Vanlige feil og feils\u00f8kingsmetoder<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e06e825 elementor-widget elementor-widget-text-editor\" data-id=\"e06e825\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>\u00a0<\/h3><table><thead><tr><th><strong>Feil<\/strong><\/th><th><strong>Mulig \u00e5rsak<\/strong><\/th><th><strong>Feils\u00f8kingsmetode<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>Aktuatoren vil ikke \u00e5pne eller lukke ved oppstart<\/strong><\/td><td>1. Feil kabling<\/td><td>Kontroller at kablingen er korrekt i henhold til aktuatorens koblingsskjema.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Feil str\u00f8mforsyning<\/td><td>S\u00f8rg for at str\u00f8mforsyningens utgangsspenning er innenfor \u00b110% av aktuatorens nominelle spenning, og at str\u00f8mmen er 3 ganger aktuatorens nominelle str\u00f8m.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Unormal kontrollbryter eller rel\u00e9<\/td><td>M\u00e5l inngangsspenningen p\u00e5 aktuatorens bryterstyringsterminal med et multimeter for \u00e5 sikre at den stemmer overens med den forventede verdien.<\/td><\/tr><tr><td>\u00a0<\/td><td>4. Manglende samsvar mellom kontrollsystemene<\/td><td>Bruk en mekanisk bryter for \u00e5 teste aktuatorens funksjonalitet. Hvis aktuatoren g\u00e5r som den skal, m\u00e5 du kontrollere kontrollsystemets utgangslogikk.<\/td><\/tr><tr><td>\u00a0<\/td><td>5. Flere aktuatorer eller parallellkobling av aktuatorer med andre enheter<\/td><td>Aktuatorer av brytertypen starter med en kondensator. Parallellkobling med andre enheter vil p\u00e5virke kondensatorens verdi. Aktuatorer av brytertypen b\u00f8r kun bruke enkeltstyring, ikke parallellstyring.<\/td><\/tr><tr><td><strong>Aktuatoren kan bare \u00e5pne eller lukke<\/strong><\/td><td>1. Feil kabling<\/td><td>1. Bruk en mekanisk bryter for \u00e5 teste aktuatorens funksjonalitet. Hvis den g\u00e5r som den skal, kontrollerer du kontrollsystemets utgangslogikk.<\/td><\/tr><tr><td>\u00a0<\/td><td>\u00a0<\/td><td>2. Kontroller kablingen i henhold til aktuatorens koblingsskjema.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Feil innstilling av kam for full \u00e5pning\/full lukking<\/td><td>Se \"Slik stiller du inn elektriske ventiler av brytertypen\" for riktig kamstilling.<\/td><\/tr><tr><td><strong>Aktuatoren stopper midt i slaget<\/strong><\/td><td>1. Ventilen setter seg fast<\/td><td>Kontroller om ventilen har satt seg fast, fjern blokkeringen og pr\u00f8v p\u00e5 nytt etter at aktuatorens overbelastningsvern har kj\u00f8lt seg ned.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Faste partikler i v\u00e6sken som for\u00e5rsaker at ventilen setter seg fast<\/td><td>Kontroller om faste partikler i v\u00e6sken f\u00f8rer til at ventilen blokkerer, fjern blokkeringen, og pr\u00f8v p\u00e5 nytt etter at aktuatorens overbelastningsvern har kj\u00f8lt seg ned.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Feil innstilling av stoppblokk for full \u00e5pen\/full lukket<\/td><td>Se \"Hvordan stille inn elektriske ventiler av brytertypen\" for \u00e5 justere stoppblokkens posisjon riktig.<\/td><\/tr><tr><td><strong>Kan ikke rotere aktuatoren ved hjelp av h\u00e5ndtaket<\/strong><\/td><td>1. Faste partikler i v\u00e6sken f\u00f8rer til at ventilen setter seg fast<\/td><td>Kontroller om faste partikler f\u00e5r ventilen til \u00e5 sette seg fast, fjern blokkeringen, og pr\u00f8v p\u00e5 nytt etter at aktuatorens overbelastningsvern har kj\u00f8lt seg ned.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Ventilen sitter fast<\/td><td>Kontroller om ventilen har satt seg fast, fjern blokkeringen, og pr\u00f8v p\u00e5 nytt etter at aktuatorens overbelastningsvern har kj\u00f8lt seg ned.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Aktuatorens retardasjonsmekanisme er skadet<\/td><td>Fjern aktuatoren fra ventilen, og roter h\u00e5ndtaket. Hvis den ikke roterer, bytt den ut med en ny aktuator.<\/td><\/tr><tr><td><strong>Ingen utgang fra posisjonstilbakemeldingssignal<\/strong><\/td><td>1. Feil kabling av bryteren<\/td><td>Kontroller at kablingen er korrekt i henhold til aktuatorens koblingsskjema.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Feil innstilling av kam for full \u00e5pning\/full lukking<\/td><td>Se \"Hvordan stille inn elektriske ventiler av brytertypen\" for \u00e5 justere kamstillingen riktig.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Overstr\u00f8m for\u00e5rsaker svikt i bryteren for posisjonstilbakemelding<\/td><td>1. Se \"Hvordan stille inn elektriske ventiler av brytertypen\" for \u00e5 kontrollere om kammen for full \u00e5pning\/full lukking trykker riktig p\u00e5 bryteren for posisjonstilbakemelding.<\/td><\/tr><tr><td>\u00a0<\/td><td>\u00a0<\/td><td>2. M\u00e5l om kretsen for posisjonstilbakemelding er tilkoblet.<\/td><\/tr><\/tbody><\/table><p>\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6802156 elementor-widget elementor-widget-heading\" data-id=\"6802156\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2. Verifiser applikasjonsbetingelser for kompatibilitet<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be9bb57 elementor-widget elementor-widget-text-editor\" data-id=\"be9bb57\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"5234\" data-end=\"5479\">Elektriske aktuatorer kan svikte hvis de brukes feil eller under feil bruksforhold. Ved \u00e5 s\u00f8rge for at aktuatoren fungerer innenfor spesifikasjonene som er definert i produktdatabladet, sikrer du langvarig og problemfri drift.<\/p><ul data-start=\"5481\" data-end=\"6708\" data-is-only-node=\"\"><li class=\"\" data-start=\"5481\" data-end=\"5667\"><p class=\"\" data-start=\"5483\" data-end=\"5667\"><strong data-start=\"5483\" data-end=\"5507\">Str\u00f8mforsyningsspenning<\/strong>: Spenningen fra str\u00f8mforsyningen m\u00e5 ligge innenfor aktuatorens nominelle driftsspenningsomr\u00e5de. Overspenning eller underspenning kan redusere aktuatorens levetid.<\/p><\/li><li class=\"\" data-start=\"5671\" data-end=\"5866\"><p class=\"\" data-start=\"5673\" data-end=\"5866\"><strong data-start=\"5673\" data-end=\"5697\">Str\u00f8mforsyningsstr\u00f8m<\/strong>: Siden motorens startstr\u00f8m er mye h\u00f8yere enn merkestr\u00f8mmen, m\u00e5 du s\u00f8rge for at str\u00f8mforsyningen har minst 3 ganger aktuatorens merkestr\u00f8mkapasitet.<\/p><\/li><li class=\"\" data-start=\"5868\" data-end=\"6082\"><p class=\"\" data-start=\"5870\" data-end=\"6082\"><strong data-start=\"5870\" data-end=\"5885\">Temperatur<\/strong>: S\u00f8rg for at aktuatoren fungerer innenfor det nominelle temperaturomr\u00e5det. Bruk av aktuatoren utenfor det nominelle temperaturomr\u00e5det kan f\u00f8re til funksjonsfeil eller redusert levetid, noe som i siste instans kan f\u00f8re til svikt.<\/p><\/li><li class=\"\" data-start=\"6084\" data-end=\"6498\"><p class=\"\" data-start=\"6086\" data-end=\"6498\"><strong data-start=\"6086\" data-end=\"6101\">Milj\u00f8<\/strong>: DCL-aktuatorer av brytertypen er IP67-klassifisert for v\u00e6rbestandighet, og egner seg for b\u00e5de innend\u00f8rs og utend\u00f8rs bruk. De gir en viss beskyttelse mot regn, vannsprut og UV-str\u00e5ler (sollys), noe som vanligvis forlenger produktets levetid. Sv\u00e6rt korrosive milj\u00f8er kan imidlertid f\u00f8re til tidlig svikt i de elektroniske komponentene. Ikke bruk aktuatorer i ikke-eksplosjonssikre serier i farlige milj\u00f8er.<\/p><\/li><li class=\"\" data-start=\"6500\" data-end=\"6708\"><p class=\"\" data-start=\"6502\" data-end=\"6708\"><strong data-start=\"6502\" data-end=\"6516\">Driftssyklus<\/strong>: DCL-aktuatoren har en driftssyklus p\u00e5 70% (42 sekunders drift etterfulgt av 18 sekunders hvile). Overskridelse av denne driftssyklusen kan f\u00f8re til at motoren g\u00e5r inn i termisk beskyttelsesmodus.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-823dd6a elementor-widget elementor-widget-heading\" data-id=\"823dd6a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Kontroller kablingen til aktuatoren<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-32ec269 elementor-widget elementor-widget-text-editor\" data-id=\"32ec269\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"41\" data-end=\"104\">F\u00f8lg disse trinnene for \u00e5 sikre at aktuatoren fungerer som den skal:<\/p><ol data-start=\"106\" data-end=\"1403\"><li class=\"\" data-start=\"106\" data-end=\"331\"><p class=\"\" data-start=\"109\" data-end=\"156\"><strong data-start=\"109\" data-end=\"156\">Kontroller at kablingen er i henhold til diagrammet:<\/strong><\/p><ul data-start=\"160\" data-end=\"331\"><li class=\"\" data-start=\"160\" data-end=\"237\"><p class=\"\" data-start=\"162\" data-end=\"237\">Dobbeltsjekk kablingen for \u00e5 sikre at den stemmer overens med aktuatorens koblingsskjema.<\/p><\/li><li class=\"\" data-start=\"241\" data-end=\"327\"><p class=\"\" data-start=\"243\" data-end=\"327\">Kontroller at alle tilkoblinger er sikre og at ingen ledninger er l\u00f8se eller frakoblet.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"332\" data-end=\"558\"><p class=\"\" data-start=\"335\" data-end=\"366\"><strong data-start=\"335\" data-end=\"366\">Kontroller at polariteten er riktig:<\/strong><\/p><ul data-start=\"370\" data-end=\"558\"><li class=\"\" data-start=\"370\" data-end=\"483\"><p class=\"\" data-start=\"372\" data-end=\"483\">S\u00f8rg for at str\u00f8mforsyningens pluss- og minuspoler er koblet til de riktige aktuatorpolene.<\/p><\/li><li class=\"\" data-start=\"487\" data-end=\"558\"><p class=\"\" data-start=\"489\" data-end=\"558\">Feil polaritet kan f\u00f8re til funksjonsfeil eller skade p\u00e5 aktuatoren.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"560\" data-end=\"787\"><p class=\"\" data-start=\"563\" data-end=\"601\"><strong data-start=\"563\" data-end=\"601\">Inspiser kontrollsignalkablingen:<\/strong><\/p><ul data-start=\"605\" data-end=\"787\"><li class=\"\" data-start=\"605\" data-end=\"687\"><p class=\"\" data-start=\"607\" data-end=\"687\">Kontroller kablingen for styresignalene (f.eks. inngangssignal, tilbakemeldingssignal).<\/p><\/li><li class=\"\" data-start=\"691\" data-end=\"787\"><p class=\"\" data-start=\"693\" data-end=\"787\">Kontroller at signalkablene er riktig tilkoblet og ikke har kortslutninger eller brudd.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"789\" data-end=\"1011\"><p class=\"\" data-start=\"792\" data-end=\"816\"><strong data-start=\"792\" data-end=\"816\">Kontroller jording:<\/strong><\/p><ul data-start=\"820\" data-end=\"1011\"><li class=\"\" data-start=\"820\" data-end=\"929\"><p class=\"\" data-start=\"822\" data-end=\"929\">S\u00f8rg for riktig jording av aktuatoren for \u00e5 unng\u00e5 elektrisk st\u00f8y eller potensielle kortslutninger.<\/p><\/li><li class=\"\" data-start=\"933\" data-end=\"1011\"><p class=\"\" data-start=\"935\" data-end=\"1011\">En defekt jordforbindelse kan f\u00f8re til ustabil oppf\u00f8rsel eller manglende drift.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"1013\" data-end=\"1212\"><p class=\"\" data-start=\"1016\" data-end=\"1063\"><strong data-start=\"1016\" data-end=\"1063\">Bekreft kablingen for eksterne komponenter:<\/strong><\/p><ul data-start=\"1067\" data-end=\"1212\"><li class=\"\" data-start=\"1067\" data-end=\"1208\"><p class=\"\" data-start=\"1069\" data-end=\"1208\">Hvis eksterne enheter som grensebrytere, sensorer eller ekstra kontrollmoduler er tilkoblet, m\u00e5 du kontrollere at kablingen er sikker og korrekt.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"1213\" data-end=\"1403\"><p class=\"\" data-start=\"1216\" data-end=\"1245\"><strong data-start=\"1216\" data-end=\"1245\">Test kontrollkretsen:<\/strong><\/p><ul data-start=\"1249\" data-end=\"1403\"><li class=\"\" data-start=\"1249\" data-end=\"1351\"><p class=\"\" data-start=\"1251\" data-end=\"1351\">Bruk et multimeter til \u00e5 kontrollere styrekretsen, inkludert inngangsspenningen p\u00e5 styreklemmene.<\/p><\/li><li class=\"\" data-start=\"1355\" data-end=\"1403\"><p class=\"\" data-start=\"1357\" data-end=\"1403\">Bekreft at det forventede spenningsomr\u00e5det er til stede.<\/p><\/li><\/ul><\/li><\/ol><p class=\"\" data-start=\"1405\" data-end=\"1634\">N\u00e5r du har bekreftet at kablingen er riktig, fortsetter du med \u00e5 teste aktuatoren for \u00e5 sikre at den fungerer som den skal. Hvis det fortsatt er problemer etter at du har kontrollert kablingen, kan det v\u00e6re n\u00f8dvendig med ytterligere inspeksjon av aktuatorens interne komponenter.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-422047d elementor-widget elementor-widget-template\" data-id=\"422047d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"template.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-template\">\n\t\t\t\t\t<div data-elementor-type=\"section\" data-elementor-id=\"10970\" class=\"elementor elementor-10970\" data-elementor-post-type=\"elementor_library\">\n\t\t\t<div class=\"elementor-element elementor-element-19a6173 e-flex e-con-boxed e-con e-parent\" data-id=\"19a6173\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-984e463 e-con-full e-flex e-con e-child\" data-id=\"984e463\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d08c8ca elementor-widget elementor-widget-heading\" data-id=\"d08c8ca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">E - Modulering med en styreenhet<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e3dcbb5 elementor-widget elementor-widget-image\" data-id=\"e3dcbb5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"400\" height=\"330\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-e.webp\" class=\"attachment-full size-full wp-image-4857\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668E\u578b\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4396a8e elementor-widget elementor-widget-text-editor\" data-id=\"4396a8e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Inngang: 4~20mA \/ 0~10V<\/li><li>Utgang: 4~20mA \/ 0~10V<\/li><\/ul><p>\u00a0<\/p><p><strong>Tilkoblingsdetaljer:<\/strong><\/p><ol><li>Koble AC85-220V-str\u00f8mforsyningsledningen til L og n\u00f8ytral til N.<\/li><li>Koble til 4-20mA\/2-10V inngangssignalkilde fra kontrollsystemet til inngang-\/+.<\/li><li>Koble utgang -\/+ til systemet for \u00e5 sende ut ventilposisjonen i sanntid.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ff65758 e-con-full e-flex e-con e-parent\" data-id=\"ff65758\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-d5dc048 e-con-full e-flex e-con e-child\" data-id=\"d5dc048\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-527200f elementor-widget elementor-widget-text-editor\" data-id=\"527200f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Merknad\uff1a<\/p><ul><li>Kretsen innenfor den stiplede boksen er den interne kretsen til aktuatoren. Kretsen utenfor er en demonstrasjon av elektrisk tilkobling for bruk av aktuatoren.<\/li><li>Hvis du har andre spesifikke krav til tilkoblingskretsen, er du velkommen til \u00e5 kontakte v\u00e5r tekniske support.\u00a0<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-09f9fde elementor-widget elementor-widget-text-editor\" data-id=\"09f9fde\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ved feils\u00f8king p\u00e5 stedet kan du kontakte v\u00e5rt tekniske serviceteam umiddelbart for \u00e5 feils\u00f8ke problemet og finne en l\u00f8sning i fellesskap.<\/p><p>Kontaktnummer: 13026331611 (Mr. Chen)<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Denne veiledningen gjelder for DCL ultrasm\u00e5 modulerende aktuatorer, modell som f\u00f8lger: DCL-02E Vanlige feil og feils\u00f8kingsmetoder Feil Mulig \u00e5rsak Feils\u00f8kingsmetode Aktuatoren vil ikke \u00e5pne eller lukke ved oppstart 1. Feil kabling Kontroller kablingene i henhold til aktuatorens koblingsskjema for \u00e5 bekrefte at de er korrekte.   2. Feil str\u00f8mforsyning [...]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[103],"tags":[53],"class_list":["post-6034","post","type-post","status-publish","format-standard","hentry","category-mr-actuator","tag-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/nb_no\/wp-json\/wp\/v2\/posts\/6034","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/nb_no\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/nb_no\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/nb_no\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/nb_no\/wp-json\/wp\/v2\/comments?post=6034"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/nb_no\/wp-json\/wp\/v2\/posts\/6034\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/nb_no\/wp-json\/wp\/v2\/media?parent=6034"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/nb_no\/wp-json\/wp\/v2\/categories?post=6034"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/nb_no\/wp-json\/wp\/v2\/tags?post=6034"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}