{"id":6033,"date":"2023-08-03T20:44:54","date_gmt":"2023-08-03T12:44:54","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6033"},"modified":"2025-03-27T09:47:56","modified_gmt":"2025-03-27T09:47:56","slug":"dcl-02-on-off-actuator","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/lv_lv\/atbalsts\/mr-actuator\/dcl-02-on-off-actuator","title":{"rendered":"Common faults &amp; troubleshooting for DCL-02 ON-OFF actuators"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6033\" class=\"elementor elementor-6033\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-23bbd22 e-con-full e-flex e-con e-parent\" data-id=\"23bbd22\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-add184b e-con-full e-flex e-con e-child\" data-id=\"add184b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ec8fa0c elementor-widget elementor-widget-text-editor\" data-id=\"ec8fa0c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"0\" data-end=\"92\">This guide is applicable to the DCL Ultra-Small Series actuators, with the following models:<\/p><ul data-start=\"94\" data-end=\"123\"><li class=\"\" data-start=\"94\" data-end=\"103\"><p class=\"\" data-start=\"96\" data-end=\"103\">DCL-02A<\/p><\/li><li class=\"\" data-start=\"104\" data-end=\"113\"><p class=\"\" data-start=\"106\" data-end=\"113\">DCL-02B<\/p><\/li><li class=\"\" data-start=\"114\" data-end=\"123\"><p class=\"\" data-start=\"116\" data-end=\"123\">DCL-02G<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-69c14e5 elementor-widget elementor-widget-image\" data-id=\"69c14e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"176\" height=\"399\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-02-valve.webp\" class=\"attachment-full size-full wp-image-4861\" alt=\"\u534e\u6613\u7cbe\u5de7\u7cfb\u5217\u6267\u884c\u5668 DCL-02 \u914d\u9600 | DCL-02 Actuator Valve\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b43d346 elementor-widget elementor-widget-heading\" data-id=\"b43d346\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Common Faults and Troubleshooting Methods<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e1d44fb elementor-widget elementor-widget-text-editor\" data-id=\"e1d44fb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0<\/p><table><thead><tr><th><strong>Fault<\/strong><\/th><th><strong>Possible Causes<\/strong><\/th><th><strong>Troubleshooting Methods<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>Actuator does not open or close on initial start<\/strong><\/td><td>1. Incorrect wiring<\/td><td>Check the wiring according to the actuator\u2019s wiring diagram.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Incorrect power supply<\/td><td>Ensure the power supply voltage is within \u00b110% of the actuator\u2019s rated voltage and the current is 3 times the rated current.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Faulty control switch or relay<\/td><td>Measure the input voltage at the actuator&#8217;s control terminal using a multimeter to verify it matches expectations.<\/td><\/tr><tr><td>\u00a0<\/td><td>4. Control system mismatch<\/td><td>Test the actuator with a mechanical switch. If it operates normally, verify the control system&#8217;s output logic.<\/td><\/tr><tr><td>\u00a0<\/td><td>5. Multiple actuators or actuators and other devices connected in parallel<\/td><td>Switch actuators should use single-path control and not be wired in parallel, as this affects the startup capacitor.<\/td><\/tr><tr><td><strong>Actuator can only open or close<\/strong><\/td><td>1. Incorrect wiring<\/td><td>Check the wiring using the actuator\u2019s wiring diagram.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Incorrect full open\/close cam setting<\/td><td>Refer to the &#8220;How to Set Electric Switch-Type Valves&#8221; guide and correctly set the cam positions.<\/td><\/tr><tr><td><strong>Actuator stops in the middle of travel<\/strong><\/td><td>1. Valve jammed<\/td><td>Check for blockages in the valve. Clear any obstruction and retry after the actuator&#8217;s overload protection cools.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Solid material in fluid causing valve jam<\/td><td>Inspect the fluid for solid particles causing valve jams. Clear the jam and retry after the actuator\u2019s overload protection cools.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Incorrect full open\/close stopper setting<\/td><td>Refer to the &#8220;How to Set Electric Switch-Type Valves&#8221; guide and correctly adjust the stopper positions.<\/td><\/tr><tr><td><strong>Unable to turn actuator using the handle<\/strong><\/td><td>1. Solid material in fluid causing valve to seize<\/td><td>Check for blockage in the valve. Clear the blockage and retry after the actuator\u2019s overload protection cools.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Valve seizing<\/td><td>Inspect the valve for jamming. Clear the blockage and retry after the actuator\u2019s overload protection cools.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Damaged actuator reduction mechanism<\/td><td>Remove the actuator from the valve and rotate the handle. If it doesn\u2019t move, replace the actuator.<\/td><\/tr><tr><td><strong>No position feedback signal<\/strong><\/td><td>1. Incorrect wiring at the switch<\/td><td>Check the wiring according to the actuator\u2019s wiring diagram.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Incorrect full open\/close cam setting<\/td><td>Refer to the &#8220;How to Set Electric Switch-Type Valves&#8221; guide and set the cam position correctly.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Overcurrent causing position feedback switch damage<\/td><td>1. Check if the full open\/close cam is pressing on the position feedback switch correctly, as per the guide.<\/td><\/tr><tr><td>\u00a0<\/td><td>\u00a0<\/td><td>2. Measure if the position feedback circuit is closed.<\/td><\/tr><\/tbody><\/table><p>\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d58177d elementor-widget elementor-widget-heading\" data-id=\"d58177d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Verify that the operating conditions meet the parameter requirements.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60cdda7 elementor-widget elementor-widget-text-editor\" data-id=\"60cdda7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"156\" data-end=\"422\">Electric actuators may fail due to improper use or being used in incorrect operating conditions. When used within the operating conditions defined in the product specifications, the actuator can be expected to operate reliably for an extended period without failure.<\/p><ul data-start=\"424\" data-end=\"1721\"><li class=\"\" data-start=\"424\" data-end=\"610\"><p class=\"\" data-start=\"426\" data-end=\"610\"><strong data-start=\"426\" data-end=\"445\">Supply Voltage:<\/strong> The voltage from the power supply must be within the rated operating voltage range of the actuator. Overvoltage or undervoltage may shorten the actuator&#8217;s lifespan.<\/p><\/li><li class=\"\" data-start=\"614\" data-end=\"840\"><p class=\"\" data-start=\"616\" data-end=\"840\"><strong data-start=\"616\" data-end=\"635\">Supply Current:<\/strong> The starting current of the motor is significantly higher than the rated current. To ensure reliable operation, use a power supply capable of delivering at least 3 times the rated current of the actuator.<\/p><\/li><li class=\"\" data-start=\"842\" data-end=\"1035\"><p class=\"\" data-start=\"844\" data-end=\"1035\"><strong data-start=\"844\" data-end=\"860\">Temperature:<\/strong> Ensure the actuator operates within its rated temperature range. Using the actuator outside this range may result in poor performance, reduced lifespan, and eventual failure.<\/p><\/li><li class=\"\" data-start=\"1037\" data-end=\"1504\"><p class=\"\" data-start=\"1039\" data-end=\"1504\"><strong data-start=\"1039\" data-end=\"1055\">Environment:<\/strong> The DCL switch-type actuator has an IP67 weatherproof rating, making it suitable for both indoor and outdoor applications. It offers a degree of protection against rain and splashing water, helping to prolong the actuator\u2019s life by shielding it from rain, snow, ice, and UV (sunlight). However, in highly corrosive environments, electronic components may fail prematurely. Non-explosion-proof actuators should not be used in explosive environments.<\/p><\/li><li class=\"\" data-start=\"1506\" data-end=\"1721\"><p class=\"\" data-start=\"1508\" data-end=\"1721\"><strong data-start=\"1508\" data-end=\"1523\">Duty Cycle:<\/strong> The DCL switch-type actuator has a duty cycle of 70% (42 seconds of operation per minute, followed by 18 seconds of rest). Exceeding this duty cycle may cause the motor to enter thermal protection.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0273976 elementor-widget elementor-widget-heading\" data-id=\"0273976\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Check the Wiring of the Actuator<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9df2216 elementor-widget elementor-widget-text-editor\" data-id=\"9df2216\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"45\" data-end=\"186\">Ensure the actuator is wired correctly according to the wiring diagram provided by the manufacturer. Follow these steps to verify the wiring:<\/p><ol data-start=\"188\" data-end=\"1007\"><li class=\"\" data-start=\"188\" data-end=\"325\"><p class=\"\" data-start=\"191\" data-end=\"209\"><strong data-start=\"191\" data-end=\"208\">Power Supply:<\/strong><\/p><ul data-start=\"213\" data-end=\"325\"><li class=\"\" data-start=\"213\" data-end=\"321\"><p class=\"\" data-start=\"215\" data-end=\"321\">Check the power supply connections to ensure they match the actuator&#8217;s required input voltage and current.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"326\" data-end=\"504\"><p class=\"\" data-start=\"329\" data-end=\"353\"><strong data-start=\"329\" data-end=\"353\">Control Connections:<\/strong><\/p><ul data-start=\"357\" data-end=\"504\"><li class=\"\" data-start=\"357\" data-end=\"504\"><p class=\"\" data-start=\"359\" data-end=\"504\">Verify that the input and output control connections are securely attached and in the correct configuration as per the actuator\u2019s wiring diagram.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"506\" data-end=\"707\"><p class=\"\" data-start=\"509\" data-end=\"527\"><strong data-start=\"509\" data-end=\"527\">Signal Wiring:<\/strong><\/p><ul data-start=\"531\" data-end=\"707\"><li class=\"\" data-start=\"531\" data-end=\"639\"><p class=\"\" data-start=\"533\" data-end=\"639\">Check the wiring for control signals, such as 4-20mA or 0-10V, depending on the actuator\u2019s specifications.<\/p><\/li><li class=\"\" data-start=\"643\" data-end=\"707\"><p class=\"\" data-start=\"645\" data-end=\"707\">Confirm that there are no loose connections or short circuits.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"709\" data-end=\"823\"><p class=\"\" data-start=\"712\" data-end=\"726\"><strong data-start=\"712\" data-end=\"726\">Grounding:<\/strong><\/p><ul data-start=\"730\" data-end=\"823\"><li class=\"\" data-start=\"730\" data-end=\"823\"><p class=\"\" data-start=\"732\" data-end=\"823\">Ensure that the actuator is properly grounded to prevent electrical interference or damage.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"825\" data-end=\"1007\"><p class=\"\" data-start=\"828\" data-end=\"863\"><strong data-start=\"828\" data-end=\"863\">Connections to Other Equipment:<\/strong><\/p><ul data-start=\"867\" data-end=\"1007\"><li class=\"\" data-start=\"867\" data-end=\"1007\"><p class=\"\" data-start=\"869\" data-end=\"1007\">If the actuator is connected to other devices, make sure those connections are also correct and do not cause interference or power issues.<\/p><\/li><\/ul><\/li><\/ol><p class=\"\" data-start=\"1009\" data-end=\"1155\">If the wiring appears correct, but the actuator is still malfunctioning, further troubleshooting or assistance from a technician may be necessary.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-84857ae e-flex e-con-boxed e-con e-parent\" data-id=\"84857ae\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cf23cb0 elementor-widget elementor-widget-template\" data-id=\"cf23cb0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"template.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-template\">\n\t\t\t\t\t<div data-elementor-type=\"section\" data-elementor-id=\"10969\" class=\"elementor elementor-10969\" data-elementor-post-type=\"elementor_library\">\n\t\t\t<div class=\"elementor-element elementor-element-d642a8e e-flex e-con-boxed e-con e-parent\" data-id=\"d642a8e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-4dcc388 e-con-full e-flex e-con e-child\" data-id=\"4dcc388\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-09f4232 elementor-widget elementor-widget-heading\" data-id=\"09f4232\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">A \u2014 Ar 2 akt\u012bv\u0101m gala st\u0101vok\u013ca sign\u0101la izej\u0101m<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-daf3293 elementor-widget elementor-widget-image\" data-id=\"daf3293\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"341\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-a.webp\" class=\"attachment-full size-full wp-image-4860\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668A\u578b\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-14e5438 elementor-widget elementor-widget-text-editor\" data-id=\"14e5438\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Vad\u012bbas izpildmeh\u0101nisms atv\u0113r\u0161anai vai aizv\u0113r\u0161anai ar K<\/li><li>Gala poz\u012bcijas ATV\u0112RTS\/AIZV\u0112RTS izejas spaile nos\u016bt\u012bs notikumu 220 V mai\u0146str\u0101vas akt\u012bva sign\u0101la veid\u0101, kad tiks sasniegta gala poz\u012bcija.<\/li><\/ul><p>\u00a0<\/p><p><strong>Savienojuma deta\u013cas:<\/strong><\/p><ol><li>Mai\u0146str\u0101vas 85\u2013220 V baro\u0161anas avota neitr\u0101l\u0101 vada pievieno\u0161ana P1.<\/li><li>P\u0101rsl\u0113dziet mai\u0146str\u0101vas 85\u2013220 V l\u012bniju uz poz\u012bciju CLOSE (P2), lai aizv\u0113rtu v\u0101rstu.<\/li><li>P\u0101rsl\u0113dziet mai\u0146str\u0101vas 85\u2013220 V l\u012bniju uz ATV\u0112RTS (P3), lai atv\u0113rtu v\u0101rstu.<\/li><li>P5 ir termin\u0101lis ATV\u0112RT\u0100 gala poz\u012bcijai, kas izvad\u012bs mai\u0146str\u0101vas 220 V avotu, ko var izmantot, lai iesl\u0113gtu indikatora gaismu, kad izpildmeh\u0101nisms sasniedz atv\u0113rt\u0101 gala poz\u012bciju.<\/li><li>P6 ir gala poz\u012bcijas ATV\u0112RTS termin\u0101lis, kas izvad\u012bs mai\u0146str\u0101vas 220 V avotu, ko var izmantot, lai iesl\u0113gtu indikatora gaismu, kad izpildmeh\u0101nisms sasniedz gala poz\u012bciju ATV\u0112RTS.<\/li><li>Pievienojiet zem\u0113jumu P7.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f1a67a7 e-con-full e-flex e-con e-child\" data-id=\"f1a67a7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a942089 elementor-widget elementor-widget-heading\" data-id=\"a942089\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">B - With 2 passive end-position switche<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-766f845 elementor-widget elementor-widget-image\" data-id=\"766f845\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"348\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-b.webp\" class=\"attachment-full size-full wp-image-4858\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668B\u578b\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-799d994 elementor-widget elementor-widget-text-editor\" data-id=\"799d994\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Vad\u012bbas izpildmeh\u0101nisms atv\u0113r\u0161anai vai aizv\u0113r\u0161anai ar K<\/li><li>Gala poz\u012bcijas ATV\u0112RTS\/AIZV\u0112RTS izejas spaile nos\u016bt\u012bs notikumu pas\u012bva sign\u0101la veid\u0101, kad tiks sasniegta gala poz\u012bcija.<\/li><\/ul><p>\u00a0<\/p><p><strong>Savienojuma deta\u013cas:<\/strong><\/p><ol><li>Mai\u0146str\u0101vas 85\u2013220 V baro\u0161anas avota neitr\u0101l\u0101 vada pievieno\u0161ana P1.<\/li><li>P\u0101rsl\u0113dziet mai\u0146str\u0101vas 85\u2013220 V l\u012bniju uz poz\u012bciju CLOSE (P2), lai aizv\u0113rtu v\u0101rstu.<\/li><li>P\u0101rsl\u0113dziet mai\u0146str\u0101vas 85\u2013220 V l\u012bniju uz ATV\u0112RTS (P3), lai atv\u0113rtu v\u0101rstu.<\/li><li>P4 ir COM pas\u012bvajam kontakta sign\u0101lam gala poz\u012bcij\u0101 ATV\u0112RTS\/AIZV\u0112RTS, kas parasti ir savienots ar sign\u0101lu GND.<\/li><li>P5 ir gala poz\u012bcijas ATV\u0112RTS spaile, kas tiks savienota ar COM, kad izpildmeh\u0101nisms sasniegs gala poz\u012bciju ATV\u0112RTS.<\/li><li>P6 ir gala poz\u012bcijas CLOSE (AIZV\u0112RTS) spaile, kas tiks savienota ar COM, kad izpildmeh\u0101nisms sasniegs gala poz\u012bciju CLOSE (AIZV\u0112RTS).<\/li><li>Pievienojiet zem\u0113jumu P7.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-738bf4f e-con-full e-flex e-con e-child\" data-id=\"738bf4f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5a73aaa elementor-widget elementor-widget-heading\" data-id=\"5a73aaa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">G - l\u012bdzstr\u0101vas motors ar 2 gala poz\u012bcijas sl\u0113d\u017eiem<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8c393f4 elementor-widget elementor-widget-image\" data-id=\"8c393f4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"391\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-g.webp\" class=\"attachment-full size-full wp-image-4853\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668G\u578b\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a35d4cf elementor-widget elementor-widget-text-editor\" data-id=\"a35d4cf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Vad\u012bbas izpildmeh\u0101nisms atv\u0113r\u0161anai vai aizv\u0113r\u0161anai, izmantojot baro\u0161anas virzienu starp 1. un 2. spaili<\/li><li>Gala poz\u012bcijas ATV\u0112RTS\/AIZV\u0112RTS izejas spaile nos\u016bt\u012bs notikumu pas\u012bva sign\u0101la veid\u0101, kad tiks sasniegta gala poz\u012bcija.<\/li><\/ul><p>\u00a0<\/p><p><strong>Savienojuma deta\u013cas:<\/strong><\/p><ol><li>Lai aizv\u0113rtu v\u0101rstu, pievienojiet DC24V+ pie P1 un DC24V- pie P2.<\/li><li>Lai aizv\u0113rtu v\u0101rstu, pievienojiet DC24V+ pie P2 un DC24V- pie P1.<\/li><li>P3 ir COM pas\u012bvajam kontakta sign\u0101lam gala poz\u012bcij\u0101 ATV\u0112RTS\/AIZV\u0112RTS, kas parasti ir savienots ar sign\u0101lu GND.<\/li><li>P4 ir gala poz\u012bcijas ATV\u0112RTS spaile, kas tiks savienota ar COM, kad izpildmeh\u0101nisms sasniegs gala poz\u012bciju ATV\u0112RTS.<\/li><li>P5 ir gala poz\u012bcijas CLOSE (AIZV\u0112RTS) spaile, kas tiks savienota ar COM, kad izpildmeh\u0101nisms sasniegs gala poz\u012bciju CLOSE (AIZV\u0112RTS).<\/li><li>Pievienojiet zem\u0113jumu P7.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ff65758 e-con-full e-flex e-con e-parent\" data-id=\"ff65758\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-d5dc048 e-con-full e-flex e-con e-child\" data-id=\"d5dc048\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-527200f elementor-widget elementor-widget-text-editor\" data-id=\"527200f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Piez\u012bme:<\/p><ul><li>P\u0101rtraukt\u0101s r\u016bti\u0146as iek\u0161pus\u0113 redzam\u0101 \u0137\u0113de ir izpildmeh\u0101nisma iek\u0161\u0113j\u0101 \u0137\u0113de. Savuk\u0101rt \u0101r\u0113j\u0101 \u0137\u0113de ir izpildmeh\u0101nisma elektrisk\u0101 savienojuma demonstr\u0101cija.<\/li><li>Ja jums ir citas \u012bpa\u0161as pras\u012bbas attiec\u012bb\u0101 uz savienojuma \u0137\u0113di, l\u016bdzu, sazinieties ar m\u016bsu tehnisko atbalstu.\u00a0<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-002d845 elementor-widget elementor-widget-text-editor\" data-id=\"002d845\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>When conducting troubleshooting on-site, feel free to contact our technical service personnel immediately for assistance in diagnosing and resolving the issue. <br \/>Contact phone number: 13026331611 (Mr. Chen)<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>This guide is applicable to the DCL Ultra-Small Series actuators, with the following models: DCL-02A DCL-02B DCL-02G Common Faults and Troubleshooting Methods \u00a0 Fault Possible Causes Troubleshooting Methods Actuator does not open or close on initial start 1. Incorrect wiring Check the wiring according to the actuator\u2019s wiring diagram. \u00a0 2. Incorrect power supply Ensure [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[103],"tags":[53],"class_list":["post-6033","post","type-post","status-publish","format-standard","hentry","category-mr-actuator","tag-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/lv_lv\/wp-json\/wp\/v2\/posts\/6033","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/lv_lv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/lv_lv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/lv_lv\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/lv_lv\/wp-json\/wp\/v2\/comments?post=6033"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/lv_lv\/wp-json\/wp\/v2\/posts\/6033\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/lv_lv\/wp-json\/wp\/v2\/media?parent=6033"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/lv_lv\/wp-json\/wp\/v2\/categories?post=6033"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/lv_lv\/wp-json\/wp\/v2\/tags?post=6033"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}