How to control DCL actuator through modbus by vaTestTool_DCL.exe

How to control DCL actuator through modbus by vaTestTool_DCL.exe

1.Open vaTestTool_DCL-v1.31.exe. 2.The application will popup a “Connect to” dialog to set the target device id and local computer RS232 port parameters as follow. Choose the COM port which connected to the USB-RS485 connector. Select the modbus baud rate (the default baudrate on DCL actuator now is 9600). Click on “CONNECT”button to connect to the […]

Kaip išsirinkti pavaros mechanizmą?

Determining Specific Valve Drive Parameters For precise fluid control applications, it is essential to define the final valve drive parameters based on factors such as fluid pressure, media type, and control method. This ensures that the selected electric actuator meets the operational requirements. The following parameters should be determined before finalizing the actuator model: Choose […]

DCL Actuator with FSR User Manual

DCL Actuator with FSR Operation Panel Connection P1:DC24V Power + P3:DC24V Power – P5:4-20mA Input – P7:4-20mA Input + P9:4-20mA Output – P11:4-20mA Output + P2:ON/OFF Input COM P4:ON/OFF Input Open P6:ON/OFF Input Close P8:ON/OFF Output COM P10:ON/OFF Output Open P12:ON/OFF Output Close Button KO: Used in setting mode. Press this button to open the […]

DCL Actuator Modbus Application Manual(Envision Version)

Service & Support The DCL series actuators support the Modbus-RTU protocol. By referring to this application manual, you can connect the DCL actuator to Modbus. Panel Description   1. Interface Definition P1: 220VAC Neutral (N) P2: 220VAC Live (L) P3: 4-20mA Input – P4: 4-20mA Input + P5: 4-20mA Output – P6: 4-20mA Output + […]

DC-FB3 User Manual

The DC-FB3 module, when installed in the DCL electric actuator, allows for controlling the valve’s position using Modbus-TCP/IP. The installation is shown below:   1. Controlling DCL Electric Actuator via Modbus-TCP/IP Using Default Parameters The DC-FB3 is pre-configured in Client mode. Using the default MAC, IP, Gateway, Server, and Port parameters, you can control the […]

DC-FB1 User Manual

The DC-FB1 is a USB to RS485 converter, enabling communication between a computer and a device using the RS485 protocol. This manual provides the necessary steps to get your DC-FB1 up and running, enabling you to communicate with RS485 devices from your computer. Here’s how to set it up: Connecting DC-FB1 to the Computer 1.Plug […]

JB/T 8219—2016 Įprastų ir išmaniųjų elektrinių pavarų, naudojamų pramoninių procesų valdymo sistemose, standartas

Table of Contents Preface 1 Scope 2 Normative References 3 Terms and Definitions 4 Product Classification and Basic Parameters 4.1 Product Classification 4.2 Basic Parameters 5 Basic Functions of Intelligent Actuators 5.1 Display Function 5.2 Parameter Setting Function 5.3 On-Site Configuration Function 5.4 Fault Self-Diagnosis and Alarm Function 5.5 Communication Function 5.6 Other Functions 6 […]

GB/T 3369.1—2008/IEC 60381-1:1982

The standard for the 4-20mA current signal used in electric actuators is as follows: Standard: GB/T 3369.1—2008/IEC 60381-1:1982 Title: Analogue signals for process control systems — Part 1: Direct current signals (IEC 60381-1:1982, IDT) This standard defines the specifications for analog signals, specifically for the use of direct current (DC) signals in process control systems, […]

Užklausa dėl kainos

Paspauskite „Siųsti“ dabar, vėliau su jumis patvirtinsime produkto modelio numerį ir vietinį platintoją, o tada atsiųsime jums kainos pasiūlymą.

WhatsApp

Nuskaitykite QR kodą, kad galėtumėte pabendrauti su mūsų inžinieriumi dabar...

Užklausa dėl kainos

Paspauskite „Siųsti“ dabar, vėliau su jumis patvirtinsime produkto modelio numerį ir vietinį platintoją, o tada atsiųsime jums kainos pasiūlymą.

WhatsApp

Nuskaitykite QR kodą, kad galėtumėte pabendrauti su mūsų inžinieriumi dabar...

Užklausa dėl kainos

Paspauskite „Siųsti“ dabar, vėliau su jumis patvirtinsime produkto modelio numerį ir vietinį platintoją, o tada atsiųsime jums kainos pasiūlymą.

WhatsApp

Nuskaitykite QR kodą, kad galėtumėte pabendrauti su mūsų inžinieriumi dabar...

🤝 Kurkime Jūsų prekės ženklą kartu

✅ ODM

  • Jūsų logotipas ir pakuotė
  • Pasirinktiniai išvesties formatai (4–20 mA, RS485 Modbus, HART ir kt.)
  • Korpuso spalvos arba etiketės pakeitimai
  • Debesijos kompiuterijai pritaikytos versijos (neprivaloma)

✅ Originalus gamintojas

  • Griežtai laikykitės savo dizaino ir specifikacijų
  • Visiškas konfidencialumas ir intelektinės nuosavybės apsauga
  • Aukštos kokybės produkcija už konkurencingą kainą
  • Mažos partijos arba didelio masto gamyba
  • 🏭 Vidiniai moksliniai tyrimai ir plėtra bei gamybaNuo spausdintinės plokštės iki korpuso – viskas po vienu stogu.
  • 💬 Daugiakalbis palaikymasAngliškai kalbantys inžinieriai ir pardavimų darbuotojai.

  • ⚙️ Lankstus minimalus užsakymo kiekis: Parama tiek startuoliams, tiek pasauliniams prekių ženklams.

  • 🚀 Greitas prototipų kūrimasPavyzdžio pristatymas per 7–10 dienų.

 Susisiekite su mumis šiandien užsisakyti produktų katalogą arba gauti nemokamą konsultaciją.

Užklausa dėl kainos

Siųsti užklausą

WhatsApp

Nuskaitykite QR kodą, kad galėtumėte pabendrauti su mūsų inžinieriumi dabar...

Susisiekite su mumis

Telefonas

(+86) 130 2633 1611

WhatsApp

Kenas Bryanas

即时客服图标 | Tiesioginio pranešimo piktograma

Svetainės pokalbyje

Norėdami su mumis pabendrauti, spustelėkite piktogramą apatiniame dešiniajame kampe...