{"id":6034,"date":"2023-08-03T20:40:54","date_gmt":"2023-08-03T12:40:54","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6034"},"modified":"2025-03-27T09:36:11","modified_gmt":"2025-03-27T09:36:11","slug":"dcl-02-modulating-actuator","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/it\/supporto\/attuatore-mr\/attuatore-modulante-dcl-02","title":{"rendered":"Guasti comuni e risoluzione dei problemi per gli attuatori modulanti DCL-02"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6034\" class=\"elementor elementor-6034\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4d0a73a e-con-full e-flex e-con e-parent\" data-id=\"4d0a73a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-074db40 e-con-full e-flex e-con e-child\" data-id=\"074db40\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c0eba31 elementor-widget elementor-widget-text-editor\" data-id=\"c0eba31\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Questa guida si applica agli attuatori modulanti ultra compatti DCL, modello seguente:<\/p><p>DCL-02E<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-baf5aaf elementor-widget elementor-widget-image\" data-id=\"baf5aaf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-02-valve.webp\" title=\"\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b4622d9 elementor-widget elementor-widget-heading\" data-id=\"b4622d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Guasti comuni e metodi di risoluzione dei problemi<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e06e825 elementor-widget elementor-widget-text-editor\" data-id=\"e06e825\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>\u00a0<\/h3><table><thead><tr><th><strong>Colpa<\/strong><\/th><th><strong>Possibile causa<\/strong><\/th><th><strong>Metodo di risoluzione dei problemi<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>L&#039;attuatore non si aprir\u00e0 n\u00e9 si chiuder\u00e0 all&#039;avvio.<\/strong><\/td><td>1. Cablaggio errato<\/td><td>Verificare il cablaggio in base allo schema elettrico dell&#039;attuatore per accertarsi che sia corretto.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Alimentazione elettrica errata<\/td><td>Assicurarsi che la tensione di uscita dell&#039;alimentatore sia entro \u00b110% dalla tensione nominale dell&#039;attuatore e che la corrente sia 3 volte la corrente nominale dell&#039;attuatore.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Interruttore o rel\u00e8 di controllo anomalo<\/td><td>Misurare la tensione di ingresso sul terminale di controllo dell&#039;interruttore dell&#039;attuatore con un multimetro per assicurarsi che corrisponda al valore previsto.<\/td><\/tr><tr><td>\u00a0<\/td><td>4. Mancata corrispondenza del sistema di controllo<\/td><td>Utilizzare un interruttore meccanico per testare la funzionalit\u00e0 dell&#039;attuatore. Se l&#039;attuatore funziona correttamente, verificare la logica di uscita del sistema di controllo.<\/td><\/tr><tr><td>\u00a0<\/td><td>5. Attuatori multipli o collegamento in parallelo degli attuatori con altri dispositivi<\/td><td>Gli attuatori a interruttore iniziano con un condensatore. Il collegamento in parallelo con altri dispositivi influir\u00e0 sul valore del condensatore. Gli attuatori a interruttore devono essere controllati singolarmente, non in parallelo.<\/td><\/tr><tr><td><strong>L&#039;attuatore pu\u00f2 solo aprire o chiudere<\/strong><\/td><td>1. Cablaggio errato<\/td><td>1. Utilizzare un interruttore meccanico per testare la funzionalit\u00e0 dell&#039;attuatore. Se funziona correttamente, verificare la logica di uscita del sistema di controllo.<\/td><\/tr><tr><td>\u00a0<\/td><td>\u00a0<\/td><td>2. Verificare il cablaggio in base allo schema elettrico dell&#039;attuatore.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Impostazione errata della camma di apertura\/chiusura completa<\/td><td>Per il corretto posizionamento della camma, fare riferimento alla guida &quot;Come impostare le valvole elettriche a interruttore&quot;.<\/td><\/tr><tr><td><strong>L&#039;attuatore si arresta a met\u00e0 corsa<\/strong><\/td><td>1. Blocco della valvola<\/td><td>Verifica se la valvola \u00e8 bloccata, rimuovi l&#039;ostruzione e riprova dopo che il dispositivo di protezione da sovraccarico dell&#039;attuatore si \u00e8 raffreddato.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Particelle solide nel fluido che causano il blocco della valvola<\/td><td>Verifica se la presenza di particelle solide nel fluido sta causando il blocco della valvola, rimuovi l&#039;ostruzione e riprova dopo che il dispositivo di protezione da sovraccarico dell&#039;attuatore si \u00e8 raffreddato.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Impostazione errata del blocco di arresto in posizione completamente aperta\/completamente chiusa<\/td><td>Consultare la guida &quot;Come impostare le valvole elettriche a interruttore&quot; per regolare correttamente la posizione del blocco di arresto.<\/td><\/tr><tr><td><strong>Impossibile ruotare l&#039;attuatore tramite la maniglia<\/strong><\/td><td>1. Particelle solide nel fluido che causano il bloccaggio della valvola<\/td><td>Verifica se la presenza di particelle solide sta causando il blocco della valvola, rimuovi l&#039;ostruzione e riprova dopo che il dispositivo di protezione da sovraccarico dell&#039;attuatore si \u00e8 raffreddato.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. La valvola \u00e8 bloccata<\/td><td>Verifica se la valvola \u00e8 bloccata, rimuovi l&#039;ostruzione e riprova dopo che il dispositivo di protezione da sovraccarico dell&#039;attuatore si \u00e8 raffreddato.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Il meccanismo di decelerazione dell&#039;attuatore \u00e8 danneggiato.<\/td><td>Rimuovere l&#039;attuatore dalla valvola e ruotare la maniglia. Se non ruota, sostituirlo con un attuatore nuovo.<\/td><\/tr><tr><td><strong>Nessun segnale in uscita dal feedback di posizione.<\/strong><\/td><td>1. Cablaggio errato dell&#039;interruttore<\/td><td>Verificare il cablaggio in base allo schema elettrico dell&#039;attuatore per accertarsi che sia corretto.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Impostazione errata della camma di apertura\/chiusura completa<\/td><td>Per regolare correttamente la posizione della camma, fare riferimento alla guida &quot;Come impostare le valvole elettriche a interruttore&quot;.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Sovracorrente che causa il guasto dell&#039;interruttore di retroazione di posizione<\/td><td>1. Consultare la sezione &quot;Come impostare le valvole elettriche a interruttore&quot; per verificare che la camma di apertura\/chiusura completa prema correttamente l&#039;interruttore di feedback di posizione.<\/td><\/tr><tr><td>\u00a0<\/td><td>\u00a0<\/td><td>2. Verificare se il circuito di retroazione di posizione \u00e8 collegato.<\/td><\/tr><\/tbody><\/table><p>\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6802156 elementor-widget elementor-widget-heading\" data-id=\"6802156\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2. Verificare le condizioni di applicazione per la compatibilit\u00e0<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be9bb57 elementor-widget elementor-widget-text-editor\" data-id=\"be9bb57\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"5234\" data-end=\"5479\">Gli attuatori elettrici possono guastarsi se utilizzati in modo improprio o in condizioni di applicazione non corrette. Assicurarsi che l&#039;attuatore funzioni entro le specifiche definite nella scheda tecnica del prodotto contribuir\u00e0 a garantire un funzionamento a lungo termine senza problemi.<\/p><ul data-start=\"5481\" data-end=\"6708\" data-is-only-node=\"\"><li class=\"\" data-start=\"5481\" data-end=\"5667\"><p class=\"\" data-start=\"5483\" data-end=\"5667\"><strong data-start=\"5483\" data-end=\"5507\">Tensione di alimentazione<\/strong>La tensione di alimentazione deve rientrare nell&#039;intervallo di tensione operativa nominale dell&#039;attuatore. Sovratensione o sottotensione possono ridurre la durata dell&#039;attuatore.<\/p><\/li><li class=\"\" data-start=\"5671\" data-end=\"5866\"><p class=\"\" data-start=\"5673\" data-end=\"5866\"><strong data-start=\"5673\" data-end=\"5697\">Corrente di alimentazione<\/strong>Poich\u00e9 la corrente di spunto del motore \u00e8 molto superiore alla corrente nominale, assicurarsi che l&#039;alimentatore abbia una capacit\u00e0 di corrente almeno pari a 3 volte la capacit\u00e0 di corrente nominale dell&#039;attuatore.<\/p><\/li><li class=\"\" data-start=\"5868\" data-end=\"6082\"><p class=\"\" data-start=\"5870\" data-end=\"6082\"><strong data-start=\"5870\" data-end=\"5885\">Temperatura<\/strong>Assicurarsi che l&#039;attuatore funzioni entro l&#039;intervallo di temperatura nominale. L&#039;utilizzo dell&#039;attuatore al di fuori di tale intervallo pu\u00f2 causare malfunzionamenti o una riduzione della durata, fino al guasto definitivo.<\/p><\/li><li class=\"\" data-start=\"6084\" data-end=\"6498\"><p class=\"\" data-start=\"6086\" data-end=\"6498\"><strong data-start=\"6086\" data-end=\"6101\">Ambiente<\/strong>Gli attuatori a interruttore DCL hanno un grado di protezione IP67 contro gli agenti atmosferici, adatti sia per uso interno che esterno. Offrono una certa protezione contro pioggia, spruzzi d&#039;acqua e raggi UV (luce solare), il che in genere prolunga la durata del prodotto. Tuttavia, ambienti altamente corrosivi possono causare guasti prematuri ai componenti elettronici. Non utilizzare attuatori di serie non antideflagranti in ambienti pericolosi.<\/p><\/li><li class=\"\" data-start=\"6500\" data-end=\"6708\"><p class=\"\" data-start=\"6502\" data-end=\"6708\"><strong data-start=\"6502\" data-end=\"6516\">ciclo di lavoro<\/strong>L&#039;attuatore a interruttore DCL ha un ciclo di lavoro di 70% (42 secondi di funzionamento seguiti da 18 secondi di riposo). Il superamento di questo ciclo di lavoro pu\u00f2 causare l&#039;attivazione della modalit\u00e0 di protezione termica del motore.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-823dd6a elementor-widget elementor-widget-heading\" data-id=\"823dd6a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Verificare il cablaggio dell&#039;attuatore<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-32ec269 elementor-widget elementor-widget-text-editor\" data-id=\"32ec269\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"41\" data-end=\"104\">Per garantire il corretto funzionamento dell&#039;attuatore, seguire questi passaggi:<\/p><ol data-start=\"106\" data-end=\"1403\"><li class=\"\" data-start=\"106\" data-end=\"331\"><p class=\"\" data-start=\"109\" data-end=\"156\"><strong data-start=\"109\" data-end=\"156\">Verificare il cablaggio in base allo schema:<\/strong><\/p><ul data-start=\"160\" data-end=\"331\"><li class=\"\" data-start=\"160\" data-end=\"237\"><p class=\"\" data-start=\"162\" data-end=\"237\">Ricontrollare il cablaggio per assicurarsi che corrisponda allo schema elettrico dell&#039;attuatore.<\/p><\/li><li class=\"\" data-start=\"241\" data-end=\"327\"><p class=\"\" data-start=\"243\" data-end=\"327\">Verificate che tutti i collegamenti siano saldi e che nessun filo sia allentato o scollegato.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"332\" data-end=\"558\"><p class=\"\" data-start=\"335\" data-end=\"366\"><strong data-start=\"335\" data-end=\"366\">Verificare la corretta polarit\u00e0:<\/strong><\/p><ul data-start=\"370\" data-end=\"558\"><li class=\"\" data-start=\"370\" data-end=\"483\"><p class=\"\" data-start=\"372\" data-end=\"483\">Assicurarsi che i terminali positivo e negativo dell&#039;alimentatore siano collegati ai terminali corretti dell&#039;attuatore.<\/p><\/li><li class=\"\" data-start=\"487\" data-end=\"558\"><p class=\"\" data-start=\"489\" data-end=\"558\">Una polarit\u00e0 errata pu\u00f2 causare malfunzionamenti o danni all&#039;attuatore.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"560\" data-end=\"787\"><p class=\"\" data-start=\"563\" data-end=\"601\"><strong data-start=\"563\" data-end=\"601\">Ispezionare il cablaggio del segnale di controllo:<\/strong><\/p><ul data-start=\"605\" data-end=\"787\"><li class=\"\" data-start=\"605\" data-end=\"687\"><p class=\"\" data-start=\"607\" data-end=\"687\">Verificare il cablaggio dei segnali di controllo (ad esempio, segnale di ingresso, segnale di feedback).<\/p><\/li><li class=\"\" data-start=\"691\" data-end=\"787\"><p class=\"\" data-start=\"693\" data-end=\"787\">Assicurarsi che i cavi di segnale siano collegati correttamente e che non presentino cortocircuiti o interruzioni.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"789\" data-end=\"1011\"><p class=\"\" data-start=\"792\" data-end=\"816\"><strong data-start=\"792\" data-end=\"816\">Verifica la messa a terra:<\/strong><\/p><ul data-start=\"820\" data-end=\"1011\"><li class=\"\" data-start=\"820\" data-end=\"929\"><p class=\"\" data-start=\"822\" data-end=\"929\">Assicurarsi che l&#039;attuatore sia correttamente messo a terra per evitare interferenze elettriche o potenziali cortocircuiti.<\/p><\/li><li class=\"\" data-start=\"933\" data-end=\"1011\"><p class=\"\" data-start=\"935\" data-end=\"1011\">Un collegamento di terra difettoso pu\u00f2 causare un comportamento anomalo o il mancato funzionamento.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"1013\" data-end=\"1212\"><p class=\"\" data-start=\"1016\" data-end=\"1063\"><strong data-start=\"1016\" data-end=\"1063\">Verificare il cablaggio per i componenti esterni:<\/strong><\/p><ul data-start=\"1067\" data-end=\"1212\"><li class=\"\" data-start=\"1067\" data-end=\"1208\"><p class=\"\" data-start=\"1069\" data-end=\"1208\">Se sono collegati dispositivi esterni come finecorsa, sensori o moduli di controllo aggiuntivi, verificare che il cablaggio sia sicuro e corretto.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"1213\" data-end=\"1403\"><p class=\"\" data-start=\"1216\" data-end=\"1245\"><strong data-start=\"1216\" data-end=\"1245\">Testare il circuito di controllo:<\/strong><\/p><ul data-start=\"1249\" data-end=\"1403\"><li class=\"\" data-start=\"1249\" data-end=\"1351\"><p class=\"\" data-start=\"1251\" data-end=\"1351\">Utilizzare un multimetro per verificare il circuito di controllo, inclusa la tensione di ingresso ai terminali di controllo.<\/p><\/li><li class=\"\" data-start=\"1355\" data-end=\"1403\"><p class=\"\" data-start=\"1357\" data-end=\"1403\">Verificare che sia presente l&#039;intervallo di tensione previsto.<\/p><\/li><\/ul><\/li><\/ol><p class=\"\" data-start=\"1405\" data-end=\"1634\">Dopo aver verificato la correttezza del cablaggio, procedere al collaudo dell&#039;attuatore per accertarsi che funzioni correttamente. Se, dopo aver controllato il cablaggio, persistono problemi, potrebbe essere necessario un ulteriore controllo dei componenti interni dell&#039;attuatore.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-422047d elementor-widget elementor-widget-template\" data-id=\"422047d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"template.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-template\">\n\t\t\t\t\t<div data-elementor-type=\"section\" data-elementor-id=\"10970\" class=\"elementor elementor-10970\" data-elementor-post-type=\"elementor_library\">\n\t\t\t<div class=\"elementor-element elementor-element-19a6173 e-flex e-con-boxed e-con e-parent\" data-id=\"19a6173\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-984e463 e-con-full e-flex e-con e-child\" data-id=\"984e463\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d08c8ca elementor-widget elementor-widget-heading\" data-id=\"d08c8ca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">E - Modulazione con un&#039;unit\u00e0 di controllo<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e3dcbb5 elementor-widget elementor-widget-image\" data-id=\"e3dcbb5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"400\" height=\"330\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-e.webp\" class=\"attachment-full size-full wp-image-4857\" alt=\"DCL \u534e\u6613\u6267\u884c\u5668E\u578b\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4396a8e elementor-widget elementor-widget-text-editor\" data-id=\"4396a8e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Ingresso: 4~20mA \/ 0~10V<\/li><li>Uscita: 4~20mA \/ 0~10V<\/li><\/ul><p>\u00a0<\/p><p><strong>Dettagli di connessione:<\/strong><\/p><ol><li>Collegare la linea di alimentazione CA 85-220V al terminale L e il neutro al terminale N.<\/li><li>Collegamento della sorgente di segnale di ingresso 4-20mA\/2-10V dal sistema di controllo all&#039;ingresso-\/+.<\/li><li>Collegare l&#039;uscita +\/- al sistema per inviare la posizione della valvola in tempo reale.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ff65758 e-con-full e-flex e-con e-parent\" data-id=\"ff65758\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-d5dc048 e-con-full e-flex e-con e-child\" data-id=\"d5dc048\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-527200f elementor-widget elementor-widget-text-editor\" data-id=\"527200f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Nota:<\/p><ul><li>Il circuito all&#039;interno del riquadro tratteggiato \u00e8 il circuito interno dell&#039;attuatore. Il circuito esterno, invece, mostra lo schema di collegamento elettrico per il funzionamento dell&#039;attuatore.<\/li><li>Se avete altre esigenze specifiche riguardo al circuito di collegamento, non esitate a contattare il nostro supporto tecnico.\u00a0<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-09f9fde elementor-widget elementor-widget-text-editor\" data-id=\"09f9fde\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In caso di problemi in loco, \u00e8 possibile contattare immediatamente il nostro team di assistenza tecnica per individuare e risolvere insieme il problema.<\/p><p>Numero di telefono: 13026331611 (Sig. Chen)<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>This guide applies to the DCL ultra small modulating actuators, model as follows: DCL-02E Common Faults and Troubleshooting Methods \u00a0 Fault Possible Cause Troubleshooting Method Actuator will not open or close at startup 1. Incorrect wiring Check the wiring according to the actuator wiring diagram to confirm it is correct. \u00a0 2. Incorrect power supply [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[103],"tags":[53],"class_list":["post-6034","post","type-post","status-publish","format-standard","hentry","category-mr-actuator","tag-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/it\/wp-json\/wp\/v2\/posts\/6034","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/it\/wp-json\/wp\/v2\/comments?post=6034"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/it\/wp-json\/wp\/v2\/posts\/6034\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/it\/wp-json\/wp\/v2\/media?parent=6034"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/it\/wp-json\/wp\/v2\/categories?post=6034"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/it\/wp-json\/wp\/v2\/tags?post=6034"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}