Cara mengontrol aktuator DCL melalui Modbus menggunakan vaTestTool_DCL.exe

Cara mengontrol aktuator DCL melalui Modbus menggunakan vaTestTool_DCL.exe

1.Open vaTestTool_DCL-v1.31.exe. 2.The application will popup a “Connect to” dialog to set the target device id and local computer RS232 port parameters as follow. Choose the COM port which connected to the USB-RS485 connector. Select the modbus baud rate (the default baudrate on DCL actuator now is 9600). Click on “CONNECT”button to connect to the […]

Bagaimana cara memilih aktuator?

Determining Specific Valve Drive Parameters For precise fluid control applications, it is essential to define the final valve drive parameters based on factors such as fluid pressure, media type, and control method. This ensures that the selected electric actuator meets the operational requirements. The following parameters should be determined before finalizing the actuator model: Choose […]

Panduan Pengguna Aktuator DCL dengan FSR

DCL Actuator with FSR Operation Panel Connection P1:DC24V Power + P3:DC24V Power – P5:4-20mA Input – P7:4-20mA Input + P9:4-20mA Output – P11:4-20mA Output + P2:ON/OFF Input COM P4:ON/OFF Input Open P6:ON/OFF Input Close P8:ON/OFF Output COM P10:ON/OFF Output Open P12:ON/OFF Output Close Button KO: Used in setting mode. Press this button to open the […]

Manual Aplikasi Modbus Aktuator DCL (Versi Envision)

Layanan & Dukungan Aktuator seri DCL mendukung protokol Modbus-RTU. Dengan merujuk pada manual aplikasi ini, Anda dapat menghubungkan aktuator DCL ke Modbus. Deskripsi Panel 1. Definisi Antarmuka P1: Netral 220VAC (N) P2: Hidup 220VAC (L) P3: Input 4-20mA – P4: Input 4-20mA + P5: Output 4-20mA – P6: Output 4-20mA + […]

Panduan Pengguna DC-FB3

Modul DC-FB3, ketika dipasang pada aktuator listrik DCL, memungkinkan pengendalian posisi katup menggunakan Modbus-TCP/IP. Instalasi ditunjukkan di bawah ini: 1. Mengontrol Aktuator Listrik DCL melalui Modbus-TCP/IP Menggunakan Parameter Default DC-FB3 telah dikonfigurasi sebelumnya dalam mode Klien. Dengan menggunakan parameter MAC, IP, Gateway, Server, dan Port default, Anda dapat mengontrol […]

Panduan Pengguna DC-FB1

DC-FB1 adalah konverter USB ke RS485, yang memungkinkan komunikasi antara komputer dan perangkat menggunakan protokol RS485. Manual ini memberikan langkah-langkah yang diperlukan untuk mengoperasikan DC-FB1 Anda, sehingga Anda dapat berkomunikasi dengan perangkat RS485 dari komputer Anda. Berikut cara pengaturannya: Menghubungkan DC-FB1 ke Komputer 1. Colokkan […]

JB/T 8219—2016 Standar untuk Aktuator Listrik Biasa dan Cerdas yang Digunakan dalam Sistem Kontrol Proses Industri

Table of Contents Preface 1 Scope 2 Normative References 3 Terms and Definitions 4 Product Classification and Basic Parameters 4.1 Product Classification 4.2 Basic Parameters 5 Basic Functions of Intelligent Actuators 5.1 Display Function 5.2 Parameter Setting Function 5.3 On-Site Configuration Function 5.4 Fault Self-Diagnosis and Alarm Function 5.5 Communication Function 5.6 Other Functions 6 […]

GB/T 3369.1—2008/IEC 60381-1:1982

The standard for the 4-20mA current signal used in electric actuators is as follows: Standard: GB/T 3369.1—2008/IEC 60381-1:1982 Title: Analogue signals for process control systems — Part 1: Direct current signals (IEC 60381-1:1982, IDT) This standard defines the specifications for analog signals, specifically for the use of direct current (DC) signals in process control systems, […]

Permintaan Penawaran

Tekan "Kirim" sekarang, kami akan mengkonfirmasi nomor model produk dan distributor lokal dengan Anda nanti, lalu mengirimkan penawaran harga.

WhatsApp

Pindai kode QR untuk mengobrol dengan teknisi kami sekarang...

Permintaan Penawaran

Tekan "Kirim" sekarang, kami akan mengkonfirmasi nomor model produk dan distributor lokal dengan Anda nanti, lalu mengirimkan penawaran harga.

WhatsApp

Pindai kode QR untuk mengobrol dengan teknisi kami sekarang...

Permintaan Penawaran

Tekan "Kirim" sekarang, kami akan mengkonfirmasi nomor model produk dan distributor lokal dengan Anda nanti, lalu mengirimkan penawaran harga.

WhatsApp

Pindai kode QR untuk mengobrol dengan teknisi kami sekarang...

🤝 Mari Bangun Merek Anda Bersama

✅ ODM

  • Logo & kemasan Anda
  • Format output khusus (4-20mA, RS485 Modbus, HART, dll.)
  • Perubahan warna atau label pada casing
  • Versi siap cloud (opsional)

✅ OEM

  • Ikuti desain & spesifikasi Anda dengan ketat.
  • Kerahasiaan penuh & perlindungan kekayaan intelektual
  • Produksi berkualitas tinggi dengan biaya kompetitif.
  • Produksi dalam jumlah kecil atau skala besar.
  • 🏭 Penelitian & Pengembangan & Manufaktur InternalDari PCB hingga casing, semuanya di bawah satu atap.
  • 💬 Dukungan Multibahasa: Insinyur dan staf penjualan yang berbahasa Inggris.

  • ⚙️ Jumlah pesanan minimum (MOQ) yang fleksibelDukungan untuk perusahaan rintisan maupun merek global.

  • 🚀 Pembuatan Prototipe CepatPengiriman sampel dalam 7-10 hari.

 Hubungi kami hari ini untuk meminta katalog produk atau mendapatkan konsultasi gratis.

Permintaan Penawaran

Kirim Permintaan

WhatsApp

Pindai kode QR untuk mengobrol dengan teknisi kami sekarang...

Hubungi kami

Telepon

(+86) 130 2633 1611

WhatsApp

Ken Bryan

即时客服图标 | Ikon Pesan Langsung

Obrolan di situs

Klik ikon di pojok kanan bawah untuk mengobrol dengan kami...