{"id":9257,"date":"2024-07-05T15:43:31","date_gmt":"2024-07-05T07:43:31","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=9257"},"modified":"2025-03-31T06:18:52","modified_gmt":"2025-03-31T06:18:52","slug":"dc-fb3","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/hu_hu\/tamogatas\/um-aktuator\/dc-fb3","title":{"rendered":"DC-FB3 felhaszn\u00e1l\u00f3i k\u00e9zik\u00f6nyv"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"9257\" class=\"elementor elementor-9257\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-342a362 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"342a362\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-aaa43ff\" data-id=\"aaa43ff\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-41c310b elementor-widget elementor-widget-text-editor\" data-id=\"41c310b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>A DCL elektromos m\u0171k\u00f6dtet\u0151be szerelt DC-FB3 modul lehet\u0151v\u00e9 teszi a szelep helyzet\u00e9nek vez\u00e9rl\u00e9s\u00e9t Modbus-TCP\/IP protokollon kereszt\u00fcl. A telep\u00edt\u00e9s az al\u00e1bbiakban l\u00e1that\u00f3:<\/p><figure style=\"width: 351px\" class=\"wp-caption alignnone\"><img fetchpriority=\"high\" decoding=\"async\" src=\"\/dam\/um\/images\/\/dc-fb3.webp\" alt=\"\" width=\"351\" height=\"406\" \/><figcaption class=\"wp-caption-text\">DC-FB3<\/figcaption><\/figure><h4>\u00a0<\/h4><figure style=\"width: 446px\" class=\"wp-caption alignnone\"><img decoding=\"async\" class=\"\" src=\"\/dam\/um\/images\/dcl-actuator-with-dc-fb3-scaled.webp\" alt=\"\" width=\"446\" height=\"559\" \/><figcaption class=\"wp-caption-text\">DC-FB3 be\u00e9p\u00edtve a DCL m\u0171k\u00f6dtet\u0151be<\/figcaption><\/figure><h2><strong>1. DCL elektromos aktu\u00e1tor vez\u00e9rl\u00e9se Modbus-TCP\/IP-n kereszt\u00fcl alap\u00e9rtelmezett param\u00e9terek haszn\u00e1lat\u00e1val<\/strong><\/h2><p>A DC-FB3 kliens m\u00f3dban van el\u0151re konfigur\u00e1lva. Az alap\u00e9rtelmezett MAC, IP, Gateway, Server \u00e9s Port param\u00e9terek haszn\u00e1lat\u00e1val vez\u00e9relheti a DCL elektromos aktu\u00e1tort Modbus-TCP\/IP protokollon kereszt\u00fcl. Az alap\u00e9rtelmezett param\u00e9terek az al\u00e1bbi k\u00e9pen k\u00e9k mez\u0151ben l\u00e1that\u00f3k.<\/p><p>Az alap\u00e9rtelmezett param\u00e9terek haszn\u00e1lata eset\u00e9n kihagyhatja a 2. l\u00e9p\u00e9st, \u00e9s k\u00f6zvetlen\u00fcl a 3. l\u00e9p\u00e9ssel folytathatja, a DCL elektromos aktu\u00e1tor vez\u00e9rl\u00e9s\u00e9t Modbus-TCP\/IP protokollon kereszt\u00fcl.<\/p><figure style=\"width: 500px\" class=\"wp-caption alignnone\"><img decoding=\"async\" class=\"\" src=\"\/dam\/um\/images\/dcl-actuator-with-dc-fb3-flag-scaled.webp\" alt=\"\" width=\"500\" height=\"627\" \/><figcaption class=\"wp-caption-text\">DCL Modbus TCP\/IP aktu\u00e1tor<\/figcaption><\/figure><h2><strong>2. TCP\/IP h\u00e1l\u00f3zati param\u00e9terek m\u00f3dos\u00edt\u00e1sa<\/strong><\/h2><h3><strong>2.1 Csatlakoztassa a DC-FB3-at a sz\u00e1m\u00edt\u00f3g\u00e9phez a DC-FB1 (USB - RS485) seg\u00edts\u00e9g\u00e9vel<\/strong><\/h3><figure style=\"width: 500px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"\/dam\/um\/images\/\/connect-dc-fb3-to-pc.webp\" alt=\"\" width=\"500\" height=\"374\" \/><figcaption class=\"wp-caption-text\">DCL aktu\u00e1tor csatlakoztat\u00e1sa Modbus TCP\/IP-vel rendelkez\u0151 sz\u00e1m\u00edt\u00f3g\u00e9phez<\/figcaption><\/figure><p>A DC-FB3 csatlakoztat\u00e1s\u00e1nak bek\u00f6t\u00e9se a k\u00f6vetkez\u0151:<\/p><ul><li><p><strong>Piros doboz 1<\/strong>: Csatlakoztassa AC 220V t\u00e1pegys\u00e9ghez.<\/p><\/li><li><p><strong>Z\u00f6ld doboz 4<\/strong>: Csatlakoztassa a DC-FB1 RS485 interf\u00e9sz\u00e9hez (A\/B).<\/p><\/li><li><p><strong>DC-FB1 USB<\/strong>: Csatlakoztassa a sz\u00e1m\u00edt\u00f3g\u00e9phez.<\/p><\/li><\/ul><p>Tov\u00e1bbi r\u00e9szletek\u00e9rt l\u00e1sd a DC-FB1 felhaszn\u00e1l\u00f3i k\u00e9zik\u00f6nyv\u00e9t.<\/p><h5>\u00a0<\/h5><h3><strong>2.2 H\u00e1l\u00f3zati param\u00e9terek be\u00e1ll\u00edt\u00e1sa sz\u00e1m\u00edt\u00f3g\u00e9pes konfigur\u00e1ci\u00f3s szoftverrel<\/strong><\/h3><p><strong>Konfigur\u00e1ci\u00f3s szoftver let\u00f6lt\u00e9se<\/strong>Telep\u00edtse a h\u00e1l\u00f3zati param\u00e9terek be\u00e1ll\u00edt\u00e1s\u00e1hoz sz\u00fcks\u00e9ges konfigur\u00e1ci\u00f3s szoftvert.<\/p><p><strong>V\u00e1lassza ki a megfelel\u0151 portot<\/strong>: Nyissa meg a konfigur\u00e1ci\u00f3s szoftvert, v\u00e1lassza ki a megfelel\u0151 portot, \u00e9s kattintson a <strong>KAPCSOLAT<\/strong> DC-FB3-hoz val\u00f3 csatlakoztat\u00e1shoz.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/um\/images\/\/dc-fb3-config3.webp\" width=\"681\" height=\"473\" \/><\/p><p>Csatlakoztat\u00e1s ut\u00e1n a konfigur\u00e1ci\u00f3s szoftver automatikusan beolvassa a param\u00e9tereket a DC-FB3-b\u00f3l.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/um\/images\/\/dc-fb3-config2.webp\" width=\"676\" height=\"467\" \/><\/p><p><strong>H\u00e1l\u00f3zati param\u00e9terek m\u00f3dos\u00edt\u00e1sa<\/strong>: A h\u00e1l\u00f3zati param\u00e9terek m\u00f3dos\u00edt\u00e1sa ut\u00e1n kattintson a <strong>MEGTAKAR\u00cdT\u00c1S<\/strong> a friss\u00edtett param\u00e9terek DC-FB3-ban t\u00f6rt\u00e9n\u0151 t\u00e1rol\u00e1s\u00e1hoz.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/um\/images\/\/dc-fb3-config1.webp\" width=\"677\" height=\"472\" \/><\/p><h2><strong>3. DCL aktu\u00e1tor vez\u00e9rl\u00e9se Modbus-TCP\/IP-n kereszt\u00fcl<\/strong><\/h2><h3><strong>Hardverkapcsolatok<\/strong><\/h3><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" src=\"\/dam\/um\/images\/dcl-actuator-with-dc-fb3-flag-scaled.webp\" width=\"500\" height=\"627\" \/><\/p><ul><li>Csatlakoztassa az AC220V t\u00e1pegys\u00e9get a pirossal jel\u00f6lt csatlakoz\u00f3khoz 1<\/li><li>Helyezze be az RJ45 csatlakoz\u00f3t a s\u00e1rga n\u00e9gyzettel jel\u00f6lt aljzatba 2<\/li><\/ul><p>Mostant\u00f3l modbus-RTU parancsokkal vez\u00e9relheti a m\u0171k\u00f6dtet\u0151t a k\u00f6vetkez\u0151 utas\u00edt\u00e1sok szerint: <a href=\"\/hu_hu\/tamogatas\/um-aktuator\/um-sf-zc-modbus\/\">DCL Aktu\u00e1tor Modbus Alkalmaz\u00e1si K\u00e9zik\u00f6nyv<\/a><\/p><p><a href=\"\/hu_hu\/tamogatas\/um-aktuator\/um-sf-zc-modbus\/\">Tudjon meg t\u00f6bbet<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4060921 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"4060921\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-78394cd\" data-id=\"78394cd\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4f45092 elementor-widget elementor-widget-text-editor\" data-id=\"4f45092\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"\/hu_hu\/content\/dam\/letoltesek\/app\/dlc_dc-fb3-v1.17.zip\/\" target=\"_blank\" rel=\"noopener\"><span style=\"text-decoration: underline;\">Telep\u00edt\u0151szoftver let\u00f6lt\u00e9se<\/span><\/a><\/p><p><a href=\"\/hu_hu\/um\/dc-fb1\/\" target=\"_blank\" rel=\"noopener\"><span style=\"text-decoration: underline;\">Tekintse meg a DC-FB1 haszn\u00e1lati utas\u00edt\u00e1s\u00e1t<\/span><\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>A DCL elektromos m\u0171k\u00f6dtet\u0151be telep\u00edtett DC-FB3 modul lehet\u0151v\u00e9 teszi a szelep helyzet\u00e9nek vez\u00e9rl\u00e9s\u00e9t Modbus-TCP\/IP protokollon kereszt\u00fcl. A telep\u00edt\u00e9s az al\u00e1bbiakban l\u00e1that\u00f3: 1. DCL elektromos m\u0171k\u00f6dtet\u0151 vez\u00e9rl\u00e9se Modbus-TCP\/IP protokollon kereszt\u00fcl alap\u00e9rtelmezett param\u00e9terek haszn\u00e1lat\u00e1val A DC-FB3 kliens m\u00f3dban van el\u0151re konfigur\u00e1lva. Az alap\u00e9rtelmezett MAC, IP, \u00e1tj\u00e1r\u00f3, szerver \u00e9s port param\u00e9terek haszn\u00e1lat\u00e1val vez\u00e9relheti a [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[9],"tags":[],"class_list":["post-9257","post","type-post","status-publish","format-standard","hentry","category-um-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/posts\/9257","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/comments?post=9257"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/posts\/9257\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/media?parent=9257"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/categories?post=9257"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/tags?post=9257"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}