{"id":6075,"date":"2023-08-10T11:24:32","date_gmt":"2023-08-10T03:24:32","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6075"},"modified":"2025-03-31T08:22:18","modified_gmt":"2025-03-31T08:22:18","slug":"how-24v-switch-actuator-works","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/hu_hu\/tamogatas\/ta-akutator\/hogyan-mukodik-a-24-v-os-kapcsolomukodteto","title":{"rendered":"Hogyan m\u0171k\u00f6dik a DC24V ON-OFF t\u00edpus\u00fa m\u0171k\u00f6dtet\u0151 (elektromos szelep)"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6075\" class=\"elementor elementor-6075\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-05aec29 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"05aec29\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4dc31e3\" data-id=\"4dc31e3\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-11f2047 elementor-widget elementor-widget-text-editor\" data-id=\"11f2047\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone\" src=\"\/wp-content\/uploads\/2023\/05\/dcl-actuator-product-line.webp\" width=\"680\" height=\"586\" \/><\/p><p>Amikor telep\u00edt egy <strong>DCL 24V ON-OFF t\u00edpus\u00fa elektromos szab\u00e1lyoz\u00f3szelep<\/strong> Egy cs\u0151vezet\u00e9ken rel\u00e9vel, BE-KI vez\u00e9rl\u00e9ssel vagy PLC-vel (DCS) vez\u00e9relhet\u0151, lehet\u0151v\u00e9 t\u00e9ve a folyad\u00e9k\u00e1raml\u00e1s megnyit\u00e1s\u00e1t vagy lez\u00e1r\u00e1s\u00e1t.<\/p><p>Ez az \u00fatmutat\u00f3 elmagyar\u00e1zza, hogyan <strong>DCL 24V ON-OFF t\u00edpus\u00fa elektromos aktu\u00e1torok<\/strong> rel\u00e9k, PLC-k vagy BE-KI vez\u00e9rl\u00e9s seg\u00edts\u00e9g\u00e9vel m\u0171k\u00f6dtethet\u0151.<\/p><hr \/><h3><strong>Rel\u00e9\/PLC\/DCS haszn\u00e1lata DCL aktu\u00e1torok vez\u00e9rl\u00e9s\u00e9hez<\/strong><\/h3><p><img decoding=\"async\" class=\"alignnone\" src=\"\/wp-content\/uploads\/2023\/08\/dc24v-switch-actuator-first-step-with-relay.webp\" width=\"800\" height=\"299\" \/><\/p><ul><li><p>Amikor a rel\u00e9 bekapcsolja a <strong>a t\u00e1pvezet\u00e9ket (+) az \u201eON\u201d bemeneti csatlakoz\u00f3hoz<\/strong> \u00e9s a <strong>t\u00e1pvezet\u00e9ket (-) az \u201eOFF\u201d bemeneti csatlakoz\u00f3hoz<\/strong>, a m\u0171k\u00f6dtet\u0151 <strong>nyitja a szelepet<\/strong>Teljes nyit\u00e1s ut\u00e1n a m\u0171k\u00f6dtet\u0151 meg\u00e1ll, \u00e9s a <strong>elektromos szelep nyitva marad<\/strong>.<\/p><\/li><li><p>Amikor a rel\u00e9 bekapcsolja a <strong>t\u00e1pvezet\u00e9ket (+) az \u201eOFF\u201d bemeneti csatlakoz\u00f3hoz<\/strong> \u00e9s a <strong>t\u00e1pvezet\u00e9ket (-) az \u201eON\u201d bemeneti csatlakoz\u00f3hoz<\/strong>, a m\u0171k\u00f6dtet\u0151 <strong>z\u00e1rja a szelepet<\/strong>Teljes z\u00e1r\u00e1s ut\u00e1n a m\u0171k\u00f6dtet\u0151 le\u00e1ll, \u00e9s a <strong>az elektromos szelep z\u00e1rva marad<\/strong>.<\/p><\/li><li><p>Ha a m\u0171k\u00f6dtet\u0151 m\u0171k\u00f6d\u00e9se k\u00f6zben \u00e1ramsz\u00fcnet t\u00f6rt\u00e9nik, a m\u0171k\u00f6dtet\u0151 <strong>meg\u00e1ll a vezet\u00e9sben<\/strong>, \u00e9s a <strong>az elektromos szelep a jelenlegi helyzet\u00e9ben marad<\/strong>.<\/p><\/li><li><p>Ha a m\u0171k\u00f6dtet\u0151 fel van szerelve egy <strong>f\u0171t\u0151berendez\u00e9s \u00e9s p\u00e1ramentes\u00edt\u0151<\/strong>, <strong>tartsa bekapcsolva az \u00e1ramell\u00e1t\u00e1st<\/strong> miut\u00e1n a m\u0171k\u00f6dtet\u0151 el\u00e9ri a teljesen nyitott vagy teljesen z\u00e1rt helyzetet.<\/p><\/li><\/ul><p><strong>Jegyzet:<\/strong> A mell\u00e9kelt kapcsol\u00e1si rajz egy BE-KI t\u00edpus\u00fa m\u0171k\u00f6dtet\u0151 (elektromos szelep) alapvet\u0151 funkci\u00f3j\u00e1t szeml\u00e9lteti. Gyakorlati alkalmaz\u00e1sokban, <strong>biztos\u00edt\u00e9kokat, \u00e1ramkorl\u00e1toz\u00f3kat \u00e9s egy\u00e9b v\u00e9d\u0151elemeket kell hozz\u00e1adni<\/strong>.<\/p><hr \/><h3><strong>Kapcsol\u00f3k haszn\u00e1lata DCL aktu\u00e1torok vez\u00e9rl\u00e9s\u00e9hez<\/strong><\/h3><p><img decoding=\"async\" class=\"alignnone size-medium\" src=\"\/wp-content\/uploads\/2023\/08\/dc24v-switch-actuator-first-step-with-switch.webp\" alt=\"DC24V-os kapcsol\u00f3m\u0171k\u00f6dtet\u0151 els\u0151 l\u00e9p\u00e9s kapcsol\u00f3val\" width=\"844\" height=\"330\" \/><\/p><ul><li><p>Amikor egy <strong>KI-BE vez\u00e9rl\u00e9s<\/strong> kapcsolja a <strong>a t\u00e1pvezet\u00e9ket (+) az \u201eON\u201d bemeneti csatlakoz\u00f3hoz<\/strong> \u00e9s a <strong>t\u00e1pvezet\u00e9ket (-) az \u201eOFF\u201d bemeneti csatlakoz\u00f3hoz<\/strong>, a m\u0171k\u00f6dtet\u0151 <strong>nyitja a szelepet<\/strong>Teljes nyit\u00e1s ut\u00e1n a m\u0171k\u00f6dtet\u0151 meg\u00e1ll, \u00e9s a <strong>elektromos szelep nyitva marad<\/strong>.<\/p><\/li><li><p>Amikor egy <strong>KI-BE vez\u00e9rl\u00e9s<\/strong> kapcsolja a <strong>t\u00e1pvezet\u00e9ket (+) az \u201eOFF\u201d bemeneti csatlakoz\u00f3hoz<\/strong> \u00e9s a <strong>t\u00e1pvezet\u00e9ket (-) az \u201eON\u201d bemeneti csatlakoz\u00f3hoz<\/strong>, a m\u0171k\u00f6dtet\u0151 <strong>z\u00e1rja a szelepet<\/strong>Teljes z\u00e1r\u00e1s ut\u00e1n a m\u0171k\u00f6dtet\u0151 le\u00e1ll, \u00e9s a <strong>az elektromos szelep z\u00e1rva marad<\/strong>.<\/p><\/li><li><p>Ha a m\u0171k\u00f6dtet\u0151 m\u0171k\u00f6d\u00e9se k\u00f6zben \u00e1ramsz\u00fcnet t\u00f6rt\u00e9nik, a m\u0171k\u00f6dtet\u0151 <strong>meg\u00e1ll a vezet\u00e9sben<\/strong>, \u00e9s a <strong>az elektromos szelep a jelenlegi helyzet\u00e9ben marad<\/strong>.<\/p><\/li><li><p>Ha a m\u0171k\u00f6dtet\u0151 fel van szerelve egy <strong>f\u0171t\u0151berendez\u00e9s \u00e9s p\u00e1ramentes\u00edt\u0151<\/strong>, <strong>tartsa bekapcsolva az \u00e1ramell\u00e1t\u00e1st<\/strong> miut\u00e1n a m\u0171k\u00f6dtet\u0151 el\u00e9ri a teljesen nyitott vagy teljesen z\u00e1rt helyzetet.<\/p><\/li><\/ul><p><strong>Jegyzet:<\/strong> A mell\u00e9kelt kapcsol\u00e1si rajz egy BE-KI t\u00edpus\u00fa m\u0171k\u00f6dtet\u0151 (elektromos szelep) alapvet\u0151 funkci\u00f3j\u00e1t szeml\u00e9lteti. Gyakorlati alkalmaz\u00e1sokban, <strong>biztos\u00edt\u00e9kokat, \u00e1ramkorl\u00e1toz\u00f3kat \u00e9s egy\u00e9b v\u00e9d\u0151elemeket kell hozz\u00e1adni<\/strong>.<\/p><hr \/><h3><strong>Elektromos szelep \u00e1llapota<\/strong><\/h3><ul><li><p><strong>Z\u00e1rt poz\u00edci\u00f3<\/strong><\/p><\/li><\/ul><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/wp-content\/uploads\/2023\/08\/vale-closed.webp\" width=\"422\" height=\"388\" \/><\/p><ul><li><p><strong>Teljesen nyitott poz\u00edci\u00f3<\/strong><\/p><\/li><\/ul><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/wp-content\/uploads\/2023\/08\/vale-open.webp\" width=\"466\" height=\"388\" \/><\/p><p>\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Amikor egy DCL 24V ON-OFF t\u00edpus\u00fa elektromos szab\u00e1lyoz\u00f3szelepet telep\u00edt egy cs\u0151vezet\u00e9kre, azt rel\u00e9vel, ON-OFF vez\u00e9rl\u00e9ssel vagy PLC-vel (DCS) vez\u00e9relheti, lehet\u0151v\u00e9 t\u00e9ve a folyad\u00e9k\u00e1raml\u00e1s megnyit\u00e1s\u00e1t vagy lez\u00e1r\u00e1s\u00e1t. Ez az \u00fatmutat\u00f3 elmagyar\u00e1zza, hogyan m\u0171k\u00f6dnek a DCL 24V ON-OFF t\u00edpus\u00fa elektromos m\u0171k\u00f6dtet\u0151k rel\u00e9k, PLC-k vagy ON-OFF vez\u00e9rl\u00e9s seg\u00edts\u00e9g\u00e9vel a szelepekhez [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[8],"tags":[53,66,62,57,64,52,65],"class_list":["post-6075","post","type-post","status-publish","format-standard","hentry","category-ta-acutator","tag-actuator","tag-explosion-proof-actuator","tag-first-step","tag-general-actuator","tag-modulating-actuator","tag-fast-move-actuator","tag-very-small-actuator-tag"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/posts\/6075","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/comments?post=6075"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/posts\/6075\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/media?parent=6075"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/categories?post=6075"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/tags?post=6075"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}