{"id":6041,"date":"2023-08-03T20:58:30","date_gmt":"2023-08-03T12:58:30","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6041"},"modified":"2025-03-27T09:10:32","modified_gmt":"2025-03-27T09:10:32","slug":"dcl-gey-24v-modulating","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/hu_hu\/tamogatas\/mr-aktuator\/dcl-gey-24v-modulating","title":{"rendered":"Gyakori hib\u00e1k \u00e9s hibaelh\u00e1r\u00edt\u00e1s DC24V modul\u00e1l\u00f3 m\u0171k\u00f6dtet\u0151kn\u00e9l"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6041\" class=\"elementor elementor-6041\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2e3fdf7 e-con-full e-flex e-con e-child\" data-id=\"2e3fdf7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-47c2169 elementor-widget elementor-widget-text-editor\" data-id=\"47c2169\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>This guide is applicable to the DCL Explosion-proof Series \/ Weather-proof Series \/ Quick-Turning Series of modulating actuators powered by DC24V, with the following models:<\/p><ul><li><p><strong>Id\u0151j\u00e1r\u00e1s\u00e1ll\u00f3 m\u0171k\u00f6dtet\u0151<\/strong>: DCL-02GEY, DCL-05GEY, DCL-10GEY, DCL-20GEY, DCL-40GEY, DCL-60GEY<\/p><\/li><li><p><strong>Robban\u00e1sbiztos m\u0171k\u00f6dtet\u0151<\/strong>: DCL-Ex05GEY, DCL-Ex10GEY, DCL-Ex20GEY, DCL-Ex40GEY, DCL-Ex60GEY<\/p><\/li><\/ul><p>Let me know if you need further assistance with this guide!<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-03ae46d elementor-widget elementor-widget-image\" data-id=\"03ae46d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"696\" height=\"600\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-product-line.webp\" class=\"attachment-full size-full wp-image-4829\" alt=\"DCL \u534e\u6613\u667a\u63a7 \u6267\u884c\u5668 \u4ea7\u54c1\u7ebf | DCL Aktu\u00e1torok\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dc41cb3 elementor-widget elementor-widget-heading\" data-id=\"dc41cb3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Open the Electric Chamber Cover<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b4f350d elementor-widget elementor-widget-text-editor\" data-id=\"b4f350d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Use a Phillips screwdriver to unscrew the 4 fastening screws on the control chamber outer cover.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3417eab elementor-widget elementor-widget-image\" data-id=\"3417eab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"500\" height=\"593\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/08\/servo-module-cover.webp\" class=\"attachment-full size-full wp-image-6044\" alt=\"DCL\u6267\u884c\u5668\u63a7\u5236\u8154\u5916\u76d6\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cea5b49 elementor-widget elementor-widget-heading\" data-id=\"cea5b49\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Check the Status of the Fault Indicator Light<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-293ccda elementor-widget elementor-widget-image\" data-id=\"293ccda\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"600\" height=\"609\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/08\/gey-servo-module-interface.webp\" class=\"attachment-full size-full wp-image-6046\" alt=\"DCL 24V GEY\u6267\u884c\u5668\u63a7\u5236\u6a21\u5757\u63a5\u53e3\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-db918c7 elementor-widget elementor-widget-text-editor\" data-id=\"db918c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0<\/p><p><strong>2. Check the Fault Indicator Light Status<\/strong><\/p><p>Keep the power on and check the fault indicator lights on the actuator control module (Model: SF-ZCY):<\/p><ul><li><p><strong>L1: Green<\/strong> \u2013 Power indicator. The light is on when the power supply is connected to the servo controller\u2019s power terminals (\u2013, +).<\/p><\/li><li><p><strong>L2: Red<\/strong> \u2013 Input signal failure indicator. The light is on when the input signal fails.<\/p><\/li><li><p><strong>L3: Red<\/strong> \u2013 Position detection circuit fault indicator. The light is on when there is an open circuit, short circuit, or damage to the position potentiometer leads.<\/p><\/li><li><p><strong>L4: Red<\/strong> \u2013 Jam fault indicator. The light is on when a mechanical jam occurs.<\/p><\/li><\/ul><p><strong>Fault Diagnosis Logic:<\/strong><\/p><ul><li><p><strong>L2 On<\/strong>: If the input signal is less than 2.5mA or greater than 22mA, the servo controller considers the input signal to have failed. Measure the voltage between the input signal terminals. For a 4~20mA input signal, the voltage across the input signal terminals should be between 0.88V and 4.4V. If the input signal is less than 0.55V (corresponding to 2.5mA) or greater than 4.84V (corresponding to 22mA), this indicates an open circuit, short circuit, leakage, or incorrect signal from the control system. If the voltage between the terminals is normal but L2 is still on, there may be a fault in the servo controller.<\/p><\/li><li><p><strong>L3 On<\/strong>: Indicates a position detection circuit fault. Check if the potentiometer leads are open, shorted, or if the potentiometer itself is damaged. Normally, the voltage across the potentiometer should be around 4V, and the voltage between the potentiometer\u2019s centerline and either end should change as the potentiometer\u2019s angle changes. If all checks are normal but L3 is still on, there may be a fault in the servo controller.<\/p><\/li><li><p><strong>L4 On<\/strong>: Indicates a mechanical failure during operation. Check if the motor wiring is loose or open. Verify if the motor itself is functioning properly. Use the handwheel to turn the actuator in both directions and check if there is any jam. If all checks are normal but L4 is still on, there may be a fault in the servo controller.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-59d699f elementor-widget elementor-widget-heading\" data-id=\"59d699f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Signal Measurement<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-203fdc0 elementor-widget elementor-widget-text-editor\" data-id=\"203fdc0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li data-start=\"74\" data-end=\"325\">Measure the DC 24V power supply voltage to check if there are any fluctuations or voltage drops in the actuator&#8217;s power supply. In a negative pressure state, the actuator\u2019s output torque may decrease, which could prevent the valve from being driven.<\/li><li data-start=\"74\" data-end=\"325\">Measure the voltage between the input signal terminals (\u2013 and +).<\/li><li data-start=\"74\" data-end=\"325\">Measure the voltage between the output signal terminals (\u2013 and +).<\/li><li data-start=\"74\" data-end=\"325\">Apply an external signal, and during the actuator\u2019s operation, measure the DC 24V power supply voltage. (This will help confirm the DC 24V power supply\u2019s driving capability and any voltage drop in the cables.)<\/li><\/ul><p>When troubleshooting at the project site, you can immediately contact our technical service personnel to work together in identifying the fault and determining a solution.<br data-start=\"853\" data-end=\"856\" \/>Contact number: 13026331611 (Engineer Chen)<\/p><ul><li style=\"list-style-type: none;\">\u00a0<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Ez az \u00fatmutat\u00f3 a DCL robban\u00e1sbiztos sorozat\u00fa \/ id\u0151j\u00e1r\u00e1s\u00e1ll\u00f3 sorozat\u00fa \/ gyorsan forg\u00f3, DC24V-os t\u00e1pell\u00e1t\u00e1s\u00fa modul\u00e1l\u00f3 aktu\u00e1torokra vonatkozik, a k\u00f6vetkez\u0151 modellekben: Id\u0151j\u00e1r\u00e1s\u00e1ll\u00f3 aktu\u00e1tor: DCL-02GEY, DCL-05GEY, DCL-10GEY, DCL-20GEY, DCL-40GEY, DCL-60GEY Robban\u00e1sbiztos aktu\u00e1tor: DCL-Ex05GEY, DCL-Ex10GEY, DCL-Ex20GEY, DCL-Ex40GEY, DCL-Ex60GEY K\u00e9rj\u00fck, jelezze, ha tov\u00e1bbi seg\u00edts\u00e9gre van sz\u00fcks\u00e9ge az \u00fatmutat\u00f3val kapcsolatban! Nyissa meg az Elektromos kamr\u00e1t [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[103],"tags":[53,36,66,57,52,48],"class_list":["post-6041","post","type-post","status-publish","format-standard","hentry","category-mr-actuator","tag-actuator","tag-dcl-gey","tag-explosion-proof-actuator","tag-general-actuator","tag-fast-move-actuator","tag-trouble-shooting-guide"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/posts\/6041","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/comments?post=6041"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/posts\/6041\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/media?parent=6041"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/categories?post=6041"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/hu_hu\/wp-json\/wp\/v2\/tags?post=6041"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}