{"id":6361,"date":"2023-08-29T14:36:30","date_gmt":"2023-08-29T06:36:30","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6361"},"modified":"2025-03-31T07:36:15","modified_gmt":"2025-03-31T07:36:15","slug":"actuator-eft-immunity","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/hr_hr\/podrska\/ta-pokretac\/imunitet-aktuatora-na-eft","title":{"rendered":"Testiranje elektromagnetske interferencije za elektri\u010dne aktuatore (EFT)"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6361\" class=\"elementor elementor-6361\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-c4425ee elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"c4425ee\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-592bf2f\" data-id=\"592bf2f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-2d2988c elementor-widget elementor-widget-text-editor\" data-id=\"2d2988c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2><strong>Sve o\u0161trije elektromagnetsko okru\u017eenje u industrijskim lokacijama<\/strong><\/h2><p>Kako industrijska elektrifikacija i inteligencija nastavljaju napredovati, sve ve\u0107i broj elektri\u010dnih ure\u0111aja velike snage (kao \u0161to su kilovat-motori, frekvencijski pretvara\u010di i inverteri) integrira se u industrijske sustave upravljanja procesima. Posljedi\u010dno, elektromagnetsko okru\u017eenje u industrijskim lokacijama postaje sve slo\u017eenije. U tako izazovnom elektromagnetskom okru\u017eenju, kako mo\u017eemo pobolj\u0161ati otpornost elektri\u010dnih aktuatora na smetnje kako bismo osigurali pouzdan i stabilan rad?<\/p><p>Kako bi se osigurala pouzdanost elektroni\u010dkih kontrolera i senzora u stvarnim primjenama, IEC je prou\u010dio i klasificirao naj\u010de\u0161\u0107e i lako povezane impulse elektri\u010dnih smetnji na industrijskim lokacijama. Definirali su tipi\u010dne karakteristike valnih oblika kao \u0161to su frekvencija, period i amplituda za brze elektri\u010dne prijelazne pojave (EFT). Prije nego \u0161to se proizvod primijeni na industrijskoj lokaciji, simuliramo ove uobi\u010dajene valne oblike smetnji pomo\u0107u preliminarne opreme za ispitivanje kako bismo proveli ispitivanja protiv smetnji na proizvodu. To mo\u017ee pomo\u0107i u izbjegavanju mnogih problema povezanih s smetnjama na terenu i smanjiti potencijalne rizike kvalitete.<\/p><h2><strong>Standardi imuniteta na brze elektri\u010dne prijelazne pojave (EFT)<\/strong><\/h2><ul><li>GB\/T 17626.4-2018<\/li><li>IEC 61000-4-4:2012<\/li><\/ul><h3><strong>EFT valni oblik<\/strong><\/h3><p>Valni oblik grupe impulsa EFT interferencije i njegove karakteristike.<\/p><p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone\" src=\"\/dam\/tech\/images\/eft-wave-1.webp\" width=\"500\" height=\"334\" \/><\/p><p><img decoding=\"async\" class=\"alignnone\" src=\"\/dam\/tech\/images\/eft-wave-2.webp\" width=\"500\" height=\"565\" \/><\/p><h3><strong>Definicije razina EFT testa<\/strong><\/h3><table><thead><tr><th>Razina<\/th><th>Priklju\u010dak za napajanje i priklju\u010dak za uzemljenje (PE)<\/th><th>Signalni i upravlja\u010dki priklju\u010dak<\/th><\/tr><\/thead><tbody><tr><td>\u00a0<\/td><td>Vr\u0161ni napon (kV)<\/td><td>Frekvencija ponavljanja (kHz)<\/td><\/tr><tr><td>1<\/td><td>0.5<\/td><td>5 ili 100<\/td><\/tr><tr><td>2<\/td><td>1<\/td><td>5 ili 100<\/td><\/tr><tr><td>3<\/td><td>2<\/td><td>5 ili 100<\/td><\/tr><tr><td>4<\/td><td>4<\/td><td>5 ili 100<\/td><\/tr><tr><td>X<\/td><td>Specifi\u010dno<\/td><td>Specifi\u010dno<\/td><\/tr><\/tbody><\/table><h3><strong>Evaluacija rezultata EFT testa<\/strong><\/h3><ul><li><p><strong>Klasa A<\/strong>Unutar navedenih granica, aktuator funkcionira normalno bez smanjenja performansi.<\/p><\/li><li><p><strong>Klasa B<\/strong>Funkcija ili performanse privremeno izgubljene ili smanjene; oporavak se doga\u0111a automatski nakon prestanka poreme\u0107aja bez intervencije operatera.<\/p><\/li><li><p><strong>Klasa C<\/strong>Funkcija ili performanse privremeno izgubljene ili smanjene; oporavak zahtijeva intervenciju operatera nakon prestanka poreme\u0107aja.<\/p><\/li><li><p><strong>Klasa D<\/strong>O\u0161te\u0107enje hardvera ili softvera ili gubitak podataka, \u0161to rezultira nepovratnim gubitkom funkcije ili smanjenjem performansi.<\/p><\/li><\/ul><h2><strong>Rezultati testa imunosti na EFT elektri\u010dnog aktuatora DCL-a<\/strong><\/h2><ul><li><p><strong>Imunitet napojnog priklju\u010dka<\/strong>4 kV (Razina 4, Klasa A)<\/p><\/li><li><p><strong>Imunitet signalnog porta<\/strong>2 kV (Razina 4, Klasa A)<\/p><\/li><\/ul><h2><strong>Oprema za testiranje DCL EFT-a<\/strong><\/h2><figure style=\"width: 500px\" class=\"wp-caption alignnone\"><img decoding=\"async\" src=\"\/dam\/about-us\/images\/rd-capabilities\/fet-surge-esd-test.webp\" alt=\"\" width=\"500\" height=\"353\" \/><figcaption class=\"wp-caption-text\">Ure\u0111aj za ispitivanje EFT prenapona ESD<\/figcaption><\/figure>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Sve o\u0161trije elektromagnetsko okru\u017eenje u industrijskim objektima Kako industrijska elektrifikacija i inteligencija nastavljaju napredovati, sve ve\u0107i broj elektri\u010dnih ure\u0111aja velike snage (kao \u0161to su kilovat-motori, frekvencijski pretvara\u010di i inverteri) integrira se u industrijske sustave upravljanja procesima. Posljedi\u010dno, elektromagnetsko okru\u017eenje u industrijskim objektima postaje sve slo\u017eenije. U tako izazovnom elektromagnetskom [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[8],"tags":[53,66,57,52,55,65],"class_list":["post-6361","post","type-post","status-publish","format-standard","hentry","category-ta-acutator","tag-actuator","tag-explosion-proof-actuator","tag-general-actuator","tag-fast-move-actuator","tag-tech-ref","tag-very-small-actuator-tag"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/hr_hr\/wp-json\/wp\/v2\/posts\/6361","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/hr_hr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/hr_hr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/hr_hr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/hr_hr\/wp-json\/wp\/v2\/comments?post=6361"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/hr_hr\/wp-json\/wp\/v2\/posts\/6361\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/hr_hr\/wp-json\/wp\/v2\/media?parent=6361"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/hr_hr\/wp-json\/wp\/v2\/categories?post=6361"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/hr_hr\/wp-json\/wp\/v2\/tags?post=6361"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}