{"id":6063,"date":"2023-08-08T14:18:50","date_gmt":"2023-08-08T06:18:50","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6063"},"modified":"2025-03-23T06:24:13","modified_gmt":"2025-03-23T06:24:13","slug":"calibrate-4-20ma-input","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/fr_fr\/soutien\/comment-actionner\/etalonnage-4-entree-20ma","title":{"rendered":"Comment calibrer le signal d'entr\u00e9e de l'actionneur ?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6063\" class=\"elementor elementor-6063\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-05aec29 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"05aec29\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4dc31e3\" data-id=\"4dc31e3\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-11f2047 elementor-widget elementor-widget-text-editor\" data-id=\"11f2047\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>When the actuator&#8217;s valve position does not match the 4\u201320mA input signal (resulting in a discrepancy between the feedback signal and the input signal), you can calibrate the input signal to eliminate this deviation.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-73c3568 elementor-widget elementor-widget-image\" data-id=\"73c3568\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"446\" height=\"374\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/set-actuator-hysteresis.webp\" class=\"attachment-full size-full wp-image-4999\" alt=\"\u8bbe\u7f6e\u6b66\u6c49\u534e\u6613\u7535\u52a8\u6267\u884c\u5668\u7684\u6b7b\u533a | R\u00e9glage de l&#039;hyst\u00e9r\u00e9sis de l&#039;actionneur DCL\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-54175ec elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"54175ec\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-c437fc7\" data-id=\"c437fc7\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3f9d45a elementor-widget elementor-widget-image\" data-id=\"3f9d45a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"600\" height=\"606\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/sf-zc-servo-control-pack-cn.webp\" class=\"attachment-full size-full wp-image-5320\" alt=\"\u534e\u6613\u79d1\u6280\u7535\u52a8\u9600 \u63a7\u5236\u6a21\u5757 \u63a5\u53e3\u793a\u610f\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-5b79a39\" data-id=\"5b79a39\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-bef6a51 elementor-widget elementor-widget-image\" data-id=\"bef6a51\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"600\" height=\"599\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/sf-lc-servo-control-pack-cn.webp\" class=\"attachment-full size-full wp-image-5318\" alt=\"\u534e\u6613\u79d1\u6280\u7535\u52a8\u6267\u884c\u5668 LC\u63a7\u5236\u6a21\u5757 \u63a5\u53e3\u793a\u610f\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-b95f9a4 elementor-widget elementor-widget-text-editor\" data-id=\"b95f9a4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h4 class=\"\" data-start=\"273\" data-end=\"315\"><strong data-start=\"278\" data-end=\"313\">6 Simple Steps for Calibration:<\/strong><\/h4><ol data-start=\"317\" data-end=\"1031\"><li class=\"\" data-start=\"317\" data-end=\"364\"><p class=\"\" data-start=\"320\" data-end=\"364\">Turn the <strong data-start=\"329\" data-end=\"336\">S-A<\/strong> switch to position <strong data-start=\"356\" data-end=\"361\">2<\/strong>.<\/p><\/li><li class=\"\" data-start=\"365\" data-end=\"482\"><p class=\"\" data-start=\"368\" data-end=\"482\">Appuyer et maintenir la touche <strong data-start=\"387\" data-end=\"394\">Fixer<\/strong> button until the <strong data-start=\"412\" data-end=\"426\">L2 red LED<\/strong> lights up. (After releasing, L2 will start flashing.)<\/p><\/li><li class=\"\" data-start=\"483\" data-end=\"701\"><p class=\"\" data-start=\"486\" data-end=\"701\">Within <strong data-start=\"493\" data-end=\"506\">5 seconds<\/strong>, press and hold both the <strong data-start=\"532\" data-end=\"540\">Ouvrir<\/strong> et <strong data-start=\"545\" data-end=\"553\">Nulle part ailleurs<\/strong> buttons simultaneously. L2 flashing will switch to <strong data-start=\"605\" data-end=\"620\">L3 flashing<\/strong>, indicating that the control module has entered input signal calibration mode.<\/p><\/li><li class=\"\" data-start=\"702\" data-end=\"865\"><p class=\"\" data-start=\"705\" data-end=\"865\">Apply a <strong data-start=\"713\" data-end=\"727\">4mA signal<\/strong> from the signal source, then press and hold <strong data-start=\"772\" data-end=\"779\">Fixer<\/strong> et <strong data-start=\"784\" data-end=\"792\">Nulle part ailleurs<\/strong> simultaneously until <strong data-start=\"814\" data-end=\"830\">L4 lights up<\/strong>, completing the 4mA calibration.<\/p><\/li><li class=\"\" data-start=\"866\" data-end=\"1031\"><p class=\"\" data-start=\"869\" data-end=\"1031\">Apply a <strong data-start=\"877\" data-end=\"892\">20mA signal<\/strong> from the signal source, then press and hold <strong data-start=\"937\" data-end=\"944\">Fixer<\/strong> et <strong data-start=\"949\" data-end=\"957\">Nulle part ailleurs<\/strong> simultaneously until <strong data-start=\"979\" data-end=\"995\">L4 lights up<\/strong>, completing the 20mA calibration.<\/p><\/li><li class=\"\" data-start=\"866\" data-end=\"1031\"><p class=\"\" data-start=\"869\" data-end=\"1031\">Finally, press and hold the <strong data-start=\"1061\" data-end=\"1068\">Fixer<\/strong> button until <strong data-start=\"1082\" data-end=\"1117\">L3 stops flashing and turns off<\/strong>, indicating that the module has exited calibration mode.<\/p><\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Lorsque la position de la vanne de l&#039;actionneur ne correspond pas au signal d&#039;entr\u00e9e 4\u201320 mA (entra\u00eenant un \u00e9cart entre le signal de retour et le signal d&#039;entr\u00e9e), vous pouvez calibrer le signal d&#039;entr\u00e9e pour \u00e9liminer cet \u00e9cart. 6 \u00e9tapes simples pour le calibrage\u00a0: Placez le commutateur SA en position 2. Appuyez sur le bouton Set et maintenez-le enfonc\u00e9 jusqu&#039;\u00e0 ce que L2 [\u2026]<\/p>","protected":false},"author":1,"featured_media":10941,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[100],"tags":[53],"class_list":["post-6063","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-how-to-actuator","tag-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/posts\/6063","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/comments?post=6063"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/posts\/6063\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/media\/10941"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/media?parent=6063"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/categories?post=6063"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/tags?post=6063"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}