{"id":5363,"date":"2023-05-31T13:47:30","date_gmt":"2023-05-31T05:47:30","guid":{"rendered":"http:\/\/www.dcl-controls.com\/?p=5363"},"modified":"2025-03-23T06:24:14","modified_gmt":"2025-03-23T06:24:14","slug":"setting-switch-actuator","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/fr_fr\/soutien\/comment-actionner\/interrupteur-de-reglage-actionneur","title":{"rendered":"Comment configurer les actionneurs ON-OFF avec un transmetteur de position ?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"5363\" class=\"elementor elementor-5363\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-9d3f5d6 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"9d3f5d6\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-cc56700\" data-id=\"cc56700\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-583b268 elementor-widget elementor-widget-heading\" data-id=\"583b268\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"step1\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">1. Installation m\u00e9canique<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be92113 elementor-widget elementor-widget-text-editor\" data-id=\"be92113\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><h4 class=\"\" data-start=\"75\" data-end=\"112\"><strong data-start=\"80\" data-end=\"110\">1. Installation m\u00e9canique<\/strong><\/h4><p class=\"\" data-start=\"113\" data-end=\"288\">Se r\u00e9f\u00e9rer \u00e0 la <strong data-start=\"126\" data-end=\"174\">\"Comment installer l'actionneur sur la vanne\"<\/strong> pour installer correctement l'actionneur sur la vanne et l'actionner manuellement pour confirmer son bon fonctionnement.<\/p><p class=\"\" data-start=\"290\" data-end=\"475\">Suivez les lignes directrices dans <strong data-start=\"315\" data-end=\"357\">\"Comment r\u00e9gler la vanne \u00e9lectrique ON-OFF ?<\/strong> pour ajuster correctement la position de l'actionneur <strong data-start=\"392\" data-end=\"413\">limites \u00e9lectriques<\/strong> (limite de fermeture CLS et limite d'ouverture OLS) et les limites m\u00e9caniques.<\/p><h4 class=\"\" data-start=\"477\" data-end=\"504\"><strong data-start=\"482\" data-end=\"502\">Remarques importantes :<\/strong><\/h4><ul data-start=\"505\" data-end=\"1061\"><li class=\"\" data-start=\"505\" data-end=\"661\"><p class=\"\" data-start=\"507\" data-end=\"661\">Sauf indication contraire, l'angle de course de l'actionneur entre les positions compl\u00e8tement ferm\u00e9e et compl\u00e8tement ouverte est typiquement de <strong data-start=\"626\" data-end=\"633\">90\u00b0<\/strong> pendant le d\u00e9bogage en usine.<\/p><\/li><li class=\"\" data-start=\"662\" data-end=\"755\"><p class=\"\" data-start=\"664\" data-end=\"755\">Le courant de sortie correspond \u00e0 <strong data-start=\"698\" data-end=\"705\">4mA<\/strong> lorsqu'il est compl\u00e8tement ferm\u00e9 et <strong data-start=\"728\" data-end=\"736\">20mA<\/strong> lorsqu'il est compl\u00e8tement ouvert.<\/p><\/li><li class=\"\" data-start=\"756\" data-end=\"991\"><p class=\"\" data-start=\"758\" data-end=\"991\">Le <strong data-start=\"762\" data-end=\"788\">potentiom\u00e8tre de position<\/strong> a \u00e9t\u00e9 \u00e9talonn\u00e9 au cours du processus d'adaptation de la vanne, en tenant compte des changements de position potentiels \u00e0 pleine ouverture et \u00e0 pleine fermeture, de sorte que les utilisateurs devraient g\u00e9n\u00e9ralement \u00e9viter d'ajuster le potentiom\u00e8tre et ses engrenages.<\/p><\/li><li class=\"\" data-start=\"992\" data-end=\"1061\"><p class=\"\" data-start=\"994\" data-end=\"1061\">Suivez le sch\u00e9ma de c\u00e2blage ci-dessous pour les connexions correctes des bornes.<\/p><\/li><\/ul><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bff35e6 elementor-widget elementor-widget-heading\" data-id=\"bff35e6\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"step2\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">2. Explication du panneau de l'\u00e9metteur de position<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-198ff2d elementor-widget elementor-widget-image\" data-id=\"198ff2d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"797\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/position-feedback-setting.webp\" class=\"attachment-full size-full wp-image-5365\" alt=\"\u5982\u4f55\u8bbe\u7f6e\u6b66\u6c49\u534e\u6613\u4f4d\u53d1\u578b \u6267\u884c\u5668\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2aab9a9 elementor-widget elementor-widget-text-editor\" data-id=\"2aab9a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li data-start=\"1122\" data-end=\"1154\"><strong data-start=\"1122\" data-end=\"1152\">Potentiom\u00e8tres r\u00e9glables :<\/strong><\/li><li style=\"list-style-type: none;\"><ul data-start=\"1155\" data-end=\"1352\"><li class=\"\" data-start=\"1155\" data-end=\"1352\"><p class=\"\" data-start=\"1157\" data-end=\"1352\"><strong data-start=\"1157\" data-end=\"1176\">\"Poste \u00e0 part enti\u00e8re\"<\/strong> et <strong data-start=\"1181\" data-end=\"1200\">\"Position z\u00e9ro\"<\/strong> Les potentiom\u00e8tres sont utilis\u00e9s pour ajuster le courant de sortie correspondant \u00e0 l'intensit\u00e9 du courant de sortie. <strong data-start=\"1271\" data-end=\"1279\">20mA<\/strong> ou <strong data-start=\"1283\" data-end=\"1290\">4mA<\/strong> lorsque la vanne est compl\u00e8tement ouverte ou compl\u00e8tement ferm\u00e9e, respectivement.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"1155\" data-end=\"1352\"><p class=\"\" data-start=\"1157\" data-end=\"1352\"><strong data-start=\"1354\" data-end=\"1369\">Indicateurs :<\/strong><\/p><\/li><\/ul><ul><li style=\"list-style-type: none;\"><ul data-start=\"1372\" data-end=\"1575\"><li class=\"\" data-start=\"1372\" data-end=\"1461\"><p class=\"\" data-start=\"1374\" data-end=\"1461\"><strong data-start=\"1374\" data-end=\"1387\">L1 (rouge) :<\/strong> Indicateur d'alimentation, s'allume lorsque le transmetteur de position est sous tension.<\/p><\/li><li class=\"\" data-start=\"1462\" data-end=\"1518\"><p class=\"\" data-start=\"1464\" data-end=\"1518\"><strong data-start=\"1464\" data-end=\"1479\">L2 (vert) :<\/strong> S'allume lorsque la vanne s'ouvre.<\/p><\/li><li class=\"\" data-start=\"1519\" data-end=\"1575\"><p class=\"\" data-start=\"1521\" data-end=\"1575\"><strong data-start=\"1521\" data-end=\"1536\">L3 (vert) :<\/strong> S'allume lorsque la vanne se ferme.<\/p><\/li><\/ul><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8e4bc95 elementor-widget elementor-widget-heading\" data-id=\"8e4bc95\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"step3\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">3. D\u00e9bogage et r\u00e9glages<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-671e7a0 elementor-widget elementor-widget-text-editor\" data-id=\"671e7a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><strong data-start=\"1620\" data-end=\"1664\">D\u00e9termination de la position m\u00e9diane du potentiom\u00e8tre<\/strong><\/li><li><strong data-start=\"1667\" data-end=\"1698\">\u00c9talonnage du courant de sortie :<\/strong><br data-start=\"1698\" data-end=\"1701\" \/>Le transmetteur de position est \u00e9talonn\u00e9 en usine et ne n\u00e9cessite g\u00e9n\u00e9ralement pas de r\u00e9glage de la part de l'utilisateur. Cependant, si le courant de sortie \u00e0 pleine ouverture ou \u00e0 pleine fermeture n'est pas <strong data-start=\"1861\" data-end=\"1869\">20mA<\/strong> ou <strong data-start=\"1873\" data-end=\"1880\">4mA<\/strong> avec une erreur sup\u00e9rieure \u00e0 <strong data-start=\"1908\" data-end=\"1914\">1%<\/strong>, un calibrage est n\u00e9cessaire. Les \u00e9tapes suivantes peuvent \u00eatre suivies pour l'\u00e9talonnage :<ul><li class=\"\" data-start=\"1993\" data-end=\"2056\"><p class=\"\" data-start=\"1996\" data-end=\"2056\">Connecter un <strong data-start=\"2006\" data-end=\"2025\">Amp\u00e8rem\u00e8tre 20mA DC<\/strong> \u00e0 la borne du signal de sortie.<\/p><\/li><li class=\"\" data-start=\"2057\" data-end=\"2367\"><p class=\"\" data-start=\"2060\" data-end=\"2367\">R\u00e9gler la vanne sur <strong data-start=\"2077\" data-end=\"2093\">compl\u00e8tement ferm\u00e9<\/strong>Puis, \u00e0 l'aide d'un petit tournevis \u00e0 t\u00eate plate, r\u00e9glez la valeur de l'indicateur. <strong data-start=\"2147\" data-end=\"2180\">\"Potentiom\u00e8tre \"Position z\u00e9ro<\/strong> tout en observant l'amp\u00e8rem\u00e8tre. Tourner le potentiom\u00e8tre <strong data-start=\"2235\" data-end=\"2248\">dans le sens des aiguilles d'une montre<\/strong> si le courant est sup\u00e9rieur \u00e0 <strong data-start=\"2280\" data-end=\"2287\">4mA<\/strong> ou <strong data-start=\"2291\" data-end=\"2311\">dans le sens inverse des aiguilles d'une montre<\/strong> s'il est inf\u00e9rieur, jusqu'\u00e0 ce que l'amp\u00e8rem\u00e8tre indique <strong data-start=\"2351\" data-end=\"2366\">4mA (\u00b10,02)<\/strong>.<\/p><\/li><li class=\"\" data-start=\"2368\" data-end=\"2621\"><p class=\"\" data-start=\"2371\" data-end=\"2621\">R\u00e9gler la vanne sur <strong data-start=\"2388\" data-end=\"2402\">enti\u00e8rement ouvert<\/strong>, puis r\u00e9gler le <strong data-start=\"2420\" data-end=\"2453\">\"Potentiom\u00e8tre \"Full Position<\/strong> de la m\u00eame mani\u00e8re, en le faisant pivoter <strong data-start=\"2487\" data-end=\"2507\">dans le sens inverse des aiguilles d'une montre<\/strong> si le courant est sup\u00e9rieur \u00e0 <strong data-start=\"2539\" data-end=\"2547\">20mA<\/strong> ou <strong data-start=\"2551\" data-end=\"2564\">dans le sens des aiguilles d'une montre<\/strong> s'il est inf\u00e9rieur, jusqu'\u00e0 ce que l'amp\u00e8rem\u00e8tre indique <strong data-start=\"2604\" data-end=\"2620\">20mA (\u00b10,02)<\/strong>.<\/p><\/li><li class=\"\" data-start=\"2622\" data-end=\"2670\"><p class=\"\" data-start=\"2625\" data-end=\"2670\"><strong data-start=\"2625\" data-end=\"2655\">Calibrage du courant de sortie<\/strong> est termin\u00e9e.<\/p><\/li><\/ul><\/li><\/ul><p class=\"\" data-start=\"2672\" data-end=\"2804\"><strong data-start=\"2672\" data-end=\"2681\">Remarque :<\/strong><br data-start=\"2681\" data-end=\"2684\" \/>Ajustez toujours le <strong data-start=\"2702\" data-end=\"2721\">\"Position z\u00e9ro\"<\/strong> d'abord, puis le <strong data-start=\"2741\" data-end=\"2760\">\"Poste \u00e0 part enti\u00e8re\"<\/strong> pour \u00e9viter d'endommager le transmetteur de position.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>1. Installation m\u00e9canique 1. Installation m\u00e9canique Reportez-vous \u00e0 la section \u00ab\u00a0Installation de l\u2019actionneur sur la vanne\u00a0\u00bb pour installer correctement l\u2019actionneur sur la vanne et actionnez-le manuellement pour v\u00e9rifier son bon fonctionnement. Suivez les instructions de la section \u00ab\u00a0R\u00e9glage de l\u2019\u00e9lectrovanne marche\/arr\u00eat\u00a0\u00bb pour r\u00e9gler correctement les but\u00e9es \u00e9lectriques de l\u2019actionneur (but\u00e9e de fermeture CLS [\u2026]<\/p>","protected":false},"author":1,"featured_media":10943,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[100],"tags":[53],"class_list":["post-5363","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-how-to-actuator","tag-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/posts\/5363","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/comments?post=5363"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/posts\/5363\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/media\/10943"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/media?parent=5363"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/categories?post=5363"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/tags?post=5363"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}