{"id":4284,"date":"2023-04-23T20:40:31","date_gmt":"2023-04-23T12:40:31","guid":{"rendered":"http:\/\/www.dcl-controls.com\/?p=4284"},"modified":"2025-03-31T09:27:20","modified_gmt":"2025-03-31T09:27:20","slug":"why-explosion-proof-actuator","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/fr_fr\/soutien\/un-actionneur\/pourquoi-un-actionneur-antideflagrant","title":{"rendered":"Pourquoi certains actionneurs doivent-ils \u00eatre prot\u00e9g\u00e9s contre les explosions ?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"4284\" class=\"elementor elementor-4284\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-ef26768 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"ef26768\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-cb6e5dd\" data-id=\"cb6e5dd\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a724f46 elementor-widget elementor-widget-text-editor\" data-id=\"a724f46\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0<\/p><h2><strong>1. Qu&#039;est-ce qu&#039;une explosion ?<\/strong><\/h2><p>Une explosion se produit lorsque <strong>Les substances inflammables se m\u00e9langent \u00e0 l&#039;oxyg\u00e8ne<\/strong> et s&#039;enflammer dans certaines conditions. Si le <strong>La vitesse de r\u00e9action d\u00e9passe la vitesse du son<\/strong>, il en r\u00e9sulte un <strong>onde d&#039;explosion destructrice<\/strong>.<\/p><hr \/><h2><strong>2. Qu&#039;est-ce que la protection contre les explosions ?<\/strong><\/h2><p>\u00c0 <strong>pr\u00e9venir les explosions<\/strong>, au moins un des trois facteurs cl\u00e9s doit \u00eatre contr\u00f4l\u00e9\u00a0:<\/p><ol><li><p><strong>Substances inflammables<\/strong><\/p><\/li><li><p><strong>Oxyg\u00e8ne<\/strong><\/p><\/li><li><p><strong>Source d&#039;allumage<\/strong><\/p><\/li><\/ol><p>Depuis <strong>Les substances inflammables et l&#039;oxyg\u00e8ne sont souvent in\u00e9vitables.<\/strong> dans les environnements industriels, le <strong>La source d&#039;inflammation doit \u00eatre contr\u00f4l\u00e9e.<\/strong>.<\/p><p>Les \u00e9quipements \u00e9lectriques sont un <strong>source d&#039;inflammation potentielle<\/strong> en raison de:<br \/>\u2714 <strong>Chauffage de surface pendant le fonctionnement<\/strong><br \/>\u2714 <strong>d\u00e9charge \u00e9lectrostatique<\/strong><br \/>\u2714 <strong>\u00c9tincelles produites par les courants \u00e9lectriques<\/strong><\/p><p>Les \u00e9quipements \u00e9lectriques antid\u00e9flagrants sont <strong>con\u00e7u pour pr\u00e9venir les temp\u00e9ratures de surface excessives et les \u00e9tincelles \u00e9lectriques<\/strong>, en veillant \u00e0 ce que <strong>ne devient pas une source d&#039;inflammation<\/strong>.<\/p><p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/faq\/actuator\/why-select-a-explosion-proof-actuator\/images\/dcl-explosion-3-factors.webp\" width=\"1033\" height=\"620\" \/><\/p><hr \/><h2><strong>3. Classification des environnements dangereux<\/strong><\/h2><p>Les \u00e9quipements \u00e9lectriques antid\u00e9flagrants sont class\u00e9s en deux cat\u00e9gories\u00a0:<\/p><ul><li><p><strong>Cat\u00e9gorie I<\/strong>: \u00c9quipement pour <strong>mines de charbon<\/strong><\/p><\/li><li><p><strong>Cat\u00e9gorie II<\/strong>: \u00c9quipement pour <strong>autres environnements explosifs gazeux<\/strong><\/p><\/li><\/ul><h3><strong>\u00c9quipement de cat\u00e9gorie II<\/strong><\/h3><ol><li><p><strong>Groupes d&#039;explosion (en fonction de l&#039;espace de s\u00e9curit\u00e9 et du courant d&#039;inflammation)<\/strong><\/p><ul><li><p><strong>IIA<\/strong><\/p><\/li><li><p><strong>IIB<\/strong> (peut \u00eatre utilis\u00e9 dans les conditions IIA)<\/p><\/li><li><p><strong>IIC<\/strong> (peut \u00eatre utilis\u00e9 dans les conditions IIA et IIB)<\/p><\/li><\/ul><\/li><li><p><strong>Groupes de temp\u00e9rature (en fonction de la temp\u00e9rature maximale de surface)<\/strong><\/p><ul><li><p><strong>T1 (450\u00b0C)<\/strong><\/p><\/li><li><p><strong>T2 (300\u00b0C)<\/strong><\/p><\/li><li><p><strong>T3 (200\u00b0C)<\/strong><\/p><\/li><li><p><strong>T4 (135\u00b0C)<\/strong><\/p><\/li><li><p><strong>T5 (100\u00b0C)<\/strong><\/p><\/li><li><p><strong>T6 (85\u00b0C)<\/strong><\/p><\/li><\/ul><\/li><\/ol><p>Plus que <strong>90% de gaz explosifs<\/strong> tomber sous <strong>Groupes IIA et IIB<\/strong> et <strong>Classification des temp\u00e9ratures T1 \u00e0 T4<\/strong>.<\/p><p><img decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/faq\/actuator\/why-select-a-explosion-proof-actuator\/images\/dcl-explosion-level.webp\" width=\"1323\" height=\"400\" \/><\/p><hr \/><h2><strong>4. Comment la protection contre les explosions est-elle assur\u00e9e ?<\/strong><\/h2><p>Plusieurs m\u00e9thodes permettent de garantir que les \u00e9quipements \u00e9lectriques sont <strong>sans danger pour les environnements explosifs<\/strong>, tel que d\u00e9fini par <strong>GB3836, IEC60079, EN50014<\/strong> normes.<\/p><p><img decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/elementor\/thumbs\/dcl-explosion-no-fire-q66rupb0ie91afmk9gkhl6y0ri81l2banhzo5pk1fo.webp\" width=\"500\" height=\"314\" \/><\/p><h3><strong>Conception antid\u00e9flagrante (Exd)<\/strong><\/h3><p>Les actionneurs antid\u00e9flagrants DCL sont fabriqu\u00e9s conform\u00e9ment aux normes suivantes\u00a0:<br \/>\u2714 <strong>GB3836.1-2010, GB3836.2-2010<\/strong><br \/>\u2714 <strong>CEI 60079-0, CEI 60079-1, CEI 60079-31<\/strong><br \/>\u2714 <strong>ISO\/IEC 80079-36, ISO\/IEC 80079-37<\/strong><\/p><h4><strong>Principes de conception antid\u00e9flagrants (Exd)<\/strong><\/h4><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/dam\/faq\/actuator\/why-select-a-explosion-proof-actuator\/images\/dcl-explosion-proof.webp\" width=\"1163\" height=\"661\" \/><\/p><p>\u2714 <strong>Une explosion peut se produire \u00e0 l&#039;int\u00e9rieur de l&#039;appareil.<\/strong>mais le bo\u00eetier emp\u00eache l&#039;inflammation de l&#039;environnement ext\u00e9rieur.<br \/>\u2714 <strong>Joints ignifuges<\/strong> sont con\u00e7us avec les bonnes <strong>\u00e9cart et longueur<\/strong> pour contenir les explosions internes.<br \/>\u2714 <strong>Enceintes robustes<\/strong> r\u00e9sister \u00e0 <strong>haute pression interne<\/strong> sans se casser.<\/p><h3><strong>Composants antid\u00e9flagrants DCL<\/strong><\/h3><p>\u2714 <strong>compartiment moteur<\/strong><br \/>\u2714 <strong>compartiment des composants \u00e9lectriques<\/strong><br \/>\u2714 <strong>compartiment de c\u00e2blage<\/strong><\/p><hr \/><h2><strong>5. Certification d&#039;actionneur antid\u00e9flagrant DCL<\/strong><\/h2><h3><strong>Niveau de protection contre les explosions : Exd IIC T4 Gb<\/strong><\/h3><p>\u2714 <strong>Ex<\/strong> \u2013 Marquage antid\u00e9flagrant<br \/>\u2714 <strong>d<\/strong> \u2013 Type antid\u00e9flagrant (\u00ab Exd \u00bb)<br \/>\u2714 <strong>II<\/strong> \u2013 Applications non mini\u00e8res<br \/>\u2714 <strong>C<\/strong> \u2013 Groupe Explosion (exigences de s\u00e9curit\u00e9 plus \u00e9lev\u00e9es)<br \/>\u2714 <strong>T4<\/strong> \u2013 Temp\u00e9rature maximale de surface <strong>135\u00b0C<\/strong><br \/>\u2714 <strong>GB<\/strong> \u2013 Niveau de protection des \u00e9quipements<\/p><hr \/><h3><strong>Conclusion<\/strong><\/h3><p>Les actionneurs antid\u00e9flagrants sont essentiels dans <strong>environnements dangereux<\/strong> pour pr\u00e9venir <strong>inflammation de gaz explosifs<\/strong>. DCL&#039;s <strong>Actionneurs Exd IIC T4 Gb<\/strong> assurer la s\u00e9curit\u00e9 en :<br \/>\u2714 <strong>Contenir les explosions internes<\/strong><br \/>\u2714 <strong>Pr\u00e9venir les \u00e9tincelles et la chaleur excessive<\/strong><br \/>\u2714 <strong>R\u00e9siste \u00e0 une pression \u00e9lev\u00e9e sans rupture<\/strong><\/p><p>Ces mesures de conception rendent <strong>Les actionneurs DCL sont fiables et s\u00fbrs.<\/strong> pour <strong>applications industrielles en atmosph\u00e8res explosives<\/strong>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>\u00a0 1. Qu'est-ce qu'une explosion ? Une explosion se produit lorsque des substances inflammables se m\u00e9langent \u00e0 l'oxyg\u00e8ne et s'enflamment dans certaines conditions. Si la vitesse de r\u00e9action d\u00e9passe la vitesse du son, il en r\u00e9sulte une onde d'explosion destructrice. 2. Qu'est-ce que la protection contre les explosions ? Pour pr\u00e9venir les explosions, au moins un des trois facteurs cl\u00e9s doit \u00eatre contr\u00f4l\u00e9 : [...]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[91],"tags":[53,66,39],"class_list":["post-4284","post","type-post","status-publish","format-standard","hentry","category-an-actuator","tag-actuator","tag-explosion-proof-actuator","tag-faq"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/posts\/4284","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/comments?post=4284"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/posts\/4284\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/media?parent=4284"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/categories?post=4284"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/tags?post=4284"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}