{"id":10862,"date":"2025-03-21T03:41:07","date_gmt":"2025-03-21T03:41:07","guid":{"rendered":"https:\/\/dclcontrols.com\/?p=10862"},"modified":"2025-03-27T07:12:47","modified_gmt":"2025-03-27T07:12:47","slug":"how-actuator-works","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/fr_fr\/soutien\/actionneur\/fonctionnement-de-lactionneur","title":{"rendered":"Comment fonctionne un actionneur \u00e9lectrique ?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"10862\" class=\"elementor elementor-10862\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0b75a7f e-con-full e-flex e-con e-parent\" data-id=\"0b75a7f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-ca7c2bb e-con-full e-flex e-con e-child\" data-id=\"ca7c2bb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7a5be97 elementor-widget elementor-widget-image\" data-id=\"7a5be97\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"696\" height=\"600\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-product-line.webp\" class=\"attachment-full size-full wp-image-4829\" alt=\"DCL \u534e\u6613\u667a\u63a7 \u6267\u884c\u5668 \u4ea7\u54c1\u7ebf | DCL Actuators\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1f2b735 elementor-widget elementor-widget-text-editor\" data-id=\"1f2b735\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Une fois connect\u00e9s \u00e0 une alimentation \u00e9lectrique (AC380V, AC220V, AC24V ou DC24V), les actionneurs \u00e9lectriques DCL peuvent \u00eatre contr\u00f4l\u00e9s par un syst\u00e8me de contr\u00f4le distribu\u00e9 (DCS) \u00e0 l'aide de divers signaux de contr\u00f4le, notamment des signaux analogiques, des signaux num\u00e9riques, une communication par bus et des r\u00e9seaux IoT. L'actionneur entra\u00eene la vanne \u00e9lectrique pour l'ouvrir compl\u00e8tement, la fermer compl\u00e8tement ou l'ajuster \u00e0 une position sp\u00e9cifi\u00e9e, ce qui permet un contr\u00f4le en boucle ouverte ou en boucle ferm\u00e9e des param\u00e8tres cl\u00e9s du processus de fluide, tels que la temp\u00e9rature, le d\u00e9bit et la pression.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f0558f2 elementor-widget elementor-widget-text-editor\" data-id=\"f0558f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Comment fonctionne un actionneur \u00e9lectrique ON-OFF ?<\/strong><\/p><p>\u00a0 \u00a0 <span style=\"text-decoration: underline;\"><a href=\"#on-off-actuator\">\u00c9tat de l'actionneur<\/a><\/span><\/p><p>\u00a0 \u00a0 <span style=\"text-decoration: underline;\"><a href=\"#with-relay-ac220v\">Alimentation par AC85-265V et contr\u00f4le par relais<\/a><\/span><\/p><p>\u00a0 \u00a0 <span style=\"text-decoration: underline;\"><a href=\"#with-relay-dc24v\">Alimentation par DC24V et contr\u00f4le par relais<\/a><\/span><\/p><p>\u00a0 \u00a0 <span style=\"text-decoration: underline;\"><a href=\"#with-switch-ac220v\">Alimentation par AC220V et contr\u00f4le par interrupteur<\/a><\/span><\/p><p>\u00a0 \u00a0 <span style=\"text-decoration: underline;\"><a href=\"#with-switch-dc24v\">Alimentation par DC24V et contr\u00f4le par interrupteur<\/a><\/span><\/p><p><strong>Comment fonctionne un actionneur \u00e9lectrique modulant ?<\/strong><\/p><p>\u00a0 \u00a0 <span style=\"text-decoration: underline;\"><a href=\"#on-off-actuator\">\u00c9tat de l'actionneur<\/a><\/span><\/p><p>\u00a0 \u00a0 <span style=\"text-decoration: underline;\"><a href=\"#with-4-20ma\">Contr\u00f4le via 4-20mA<\/a><\/span><\/p><p>\u00a0 \u00a0 <span style=\"text-decoration: underline;\"><a href=\"#with-2-10v\">Commande par 2-10V<\/a><\/span><\/p><p>\u00a0 \u00a0 <span style=\"text-decoration: underline;\"><a href=\"#with-bus\">Contr\u00f4le par bus de terrain<\/a><\/span><\/p><p>\u00a0 \u00a0 <span style=\"text-decoration: underline;\"><a href=\"#with-iiot\">Contr\u00f4le via l'IIoT<\/a><\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-103c89f elementor-widget elementor-widget-heading\" data-id=\"103c89f\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"on-off-actuator\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Actionneur \u00e9lectrique ON-OFF<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-58887b7 elementor-widget elementor-widget-text-editor\" data-id=\"58887b7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Une fois qu'un actionneur \u00e9lectrique tout ou rien (vanne) est install\u00e9 sur une canalisation, il peut \u00eatre command\u00e9 \u00e0 l'aide d'un relais, d'un commutateur ou d'un automate programmable (DCS) pour ouvrir ou fermer la vanne, ce qui permet de contr\u00f4ler le d\u00e9bit du fluide.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-31dce6f elementor-widget elementor-widget-heading\" data-id=\"31dce6f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00c9tat de l'actionneur \u00e9lectrique ON-OFF<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e0e8c11 elementor-widget elementor-widget-text-editor\" data-id=\"e0e8c11\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li data-start=\"265\" data-end=\"336\"><strong data-start=\"267\" data-end=\"275\">Ouvrir<\/strong> - La valve est compl\u00e8tement ouverte, ce qui permet au fluide de passer.<\/li><li data-start=\"337\" data-end=\"401\"><strong data-start=\"339\" data-end=\"349\">Ferm\u00e9<\/strong> - La vanne est compl\u00e8tement ferm\u00e9e, ce qui arr\u00eate la circulation du fluide.<\/li><li data-start=\"402\" data-end=\"480\"><strong data-start=\"404\" data-end=\"421\">En transition<\/strong> - La vanne se d\u00e9place entre les positions ouverte et ferm\u00e9e.<\/li><li data-start=\"481\" data-end=\"590\"><strong data-start=\"483\" data-end=\"498\">D\u00e9faut\/Erreur<\/strong> - L'actionneur a rencontr\u00e9 un probl\u00e8me, tel qu'une coupure de courant, une surcharge ou une obstruction.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-14b65f8 e-con-full e-flex e-con e-child\" data-id=\"14b65f8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-6ee4fb3 e-con-full e-flex e-con e-child\" data-id=\"6ee4fb3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3808ea8 elementor-widget elementor-widget-image\" data-id=\"3808ea8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"422\" height=\"388\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/08\/vale-closed.webp\" class=\"attachment-full size-full wp-image-6112\" alt=\"\u7535\u52a8\u9600\u95e8\u5173\u95ed\u793a\u610f\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e60b796 e-con-full e-flex e-con e-child\" data-id=\"e60b796\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d656541 elementor-widget elementor-widget-image\" data-id=\"d656541\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"466\" height=\"388\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/08\/vale-open.webp\" class=\"attachment-full size-full wp-image-6114\" alt=\"\u7535\u52a8\u9600\u95e8\u5168\u5f00\u793a\u610f\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3be24e1 elementor-widget elementor-widget-heading\" data-id=\"3be24e1\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"with-relay-ac220v\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Alimentation par AC85-265V et contr\u00f4le par relais<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-de79426 elementor-widget elementor-widget-image\" data-id=\"de79426\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"826\" height=\"307\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/08\/ac220v-switch-actuator-first-step-with-relay.webp\" class=\"attachment-full size-full wp-image-6108\" alt=\"\u4f7f\u7528\u7ee7\u7535\u5668\u63a7\u5236DCL\u5f00\u5173\u578b\u6267\u884c\u5668\uff08AC220V\uff09\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3afd61b elementor-widget elementor-widget-text-editor\" data-id=\"3afd61b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><strong data-start=\"44\" data-end=\"115\">Lorsque la ligne L est commut\u00e9e sur la borne d'entr\u00e9e \"off\" par l'interm\u00e9diaire d'un relais<\/strong>L'actionneur entra\u00eene la vanne en position ferm\u00e9e. Une fois que la vanne a atteint la position de fermeture compl\u00e8te, l'actionneur s'arr\u00eate et la vanne \u00e9lectrique reste ferm\u00e9e.<\/li><li><strong data-start=\"292\" data-end=\"362\">Lorsque la ligne L est commut\u00e9e sur la borne d'entr\u00e9e \"on\" par l'interm\u00e9diaire d'un relais<\/strong>L'actionneur entra\u00eene la vanne en position ouverte. Une fois que la vanne a atteint la position d'ouverture totale, l'actionneur cesse de l'entra\u00eener et la vanne \u00e9lectrique reste enti\u00e8rement ouverte.<\/li><li><strong data-start=\"539\" data-end=\"574\">Pendant le fonctionnement de l'actionneur<\/strong>Si l'alimentation \u00e9lectrique de la ligne AC220V L est interrompue, l'actionneur s'arr\u00eate et la vanne \u00e9lectrique conserve sa position actuelle.<\/li><li><strong data-start=\"716\" data-end=\"775\">Si l'actionneur est \u00e9quip\u00e9 d'un d\u00e9shumidificateur de chauffage<\/strong>Il est important de maintenir la ligne AC220V L sous tension apr\u00e8s avoir conduit l'actionneur en position compl\u00e8tement ouverte ou ferm\u00e9e.<\/li><li style=\"list-style-type: none;\">\u00a0<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4df2295 elementor-widget elementor-widget-heading\" data-id=\"4df2295\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"with-relay-dc24v\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Alimentation par DC24V et contr\u00f4le par relais<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bb7e0f9 elementor-widget elementor-widget-image\" data-id=\"bb7e0f9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"883\" height=\"330\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/08\/dc24v-switch-actuator-first-step-with-relay.webp\" class=\"attachment-full size-full wp-image-6124\" alt=\"DCL DC24V\u5f00\u5173\u578b\u6267\u884c\u5668\u5e94\u7528\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9203b0c elementor-widget elementor-widget-text-editor\" data-id=\"9203b0c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><strong data-start=\"72\" data-end=\"196\">Lorsque le relais commute la ligne d'alimentation + sur la borne d'entr\u00e9e \"ouverte\" et la ligne d'alimentation - sur la borne d'entr\u00e9e \"ferm\u00e9e\".<\/strong>L'actionneur entra\u00eene la vanne en position ouverte. Une fois que la vanne a atteint la position d'ouverture totale, l'actionneur cesse de l'entra\u00eener et la vanne \u00e9lectrique reste enti\u00e8rement ouverte.<\/li><li><strong data-start=\"373\" data-end=\"497\">Lorsque le relais commute la ligne d'alimentation + sur la borne d'entr\u00e9e \"close\" et la ligne d'alimentation - sur la borne d'entr\u00e9e \"open\".<\/strong>L'actionneur entra\u00eene la vanne en position ferm\u00e9e. Une fois que la vanne a atteint la position de fermeture compl\u00e8te, l'actionneur s'arr\u00eate et la vanne \u00e9lectrique reste compl\u00e8tement ferm\u00e9e.<\/li><li><strong data-start=\"680\" data-end=\"715\">Pendant le fonctionnement de l'actionneur<\/strong>Si l'alimentation \u00e9lectrique est interrompue, l'actionneur cesse de fonctionner et la vanne \u00e9lectrique conserve sa position actuelle.<\/li><li><strong data-start=\"836\" data-end=\"895\">Si l'actionneur est \u00e9quip\u00e9 d'un d\u00e9shumidificateur de chauffage<\/strong>Si l'actionneur est en position ouverte ou ferm\u00e9e, assurez-vous que l'alimentation \u00e9lectrique reste sous tension apr\u00e8s avoir conduit l'actionneur en position compl\u00e8tement ouverte ou ferm\u00e9e.<\/li><li style=\"list-style-type: none;\">\u00a0<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-70cefeb elementor-widget elementor-widget-heading\" data-id=\"70cefeb\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"with-switch-ac220v\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Power by AC85-265V &amp; Control by Switch<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9aaf18f elementor-widget elementor-widget-image\" data-id=\"9aaf18f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"826\" height=\"307\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/08\/ac220v-switch-actuator-first-step-with-switch.webp\" class=\"attachment-full size-full wp-image-6110\" alt=\"\u4f7f\u7528\u65cb\u94ae\u5f00\u5173\u63a7\u5236DCL\u5f00\u5173\u578b\u6267\u884c\u5668\uff08AC220V\uff09\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d4d3474 elementor-widget elementor-widget-text-editor\" data-id=\"d4d3474\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><strong>Lorsque la ligne L est commut\u00e9e sur la borne d'entr\u00e9e \"close\" par l'interm\u00e9diaire d'un interrupteur m\u00e9canique<\/strong>L'actionneur entra\u00eene la vanne en position ferm\u00e9e. Une fois que la vanne a atteint la position de fermeture compl\u00e8te, l'actionneur s'arr\u00eate et la vanne \u00e9lectrique reste compl\u00e8tement ferm\u00e9e.<\/li><li><strong>Lorsque la ligne L est commut\u00e9e sur la borne d'entr\u00e9e \"ouverte\" par l'interm\u00e9diaire d'un interrupteur m\u00e9canique<\/strong>L'actionneur entra\u00eene la vanne en position ouverte. Une fois que la vanne a atteint la position d'ouverture totale, l'actionneur cesse de l'entra\u00eener et la vanne \u00e9lectrique reste enti\u00e8rement ouverte.<\/li><li><strong>Pendant le fonctionnement de l'actionneur<\/strong>Si l'alimentation \u00e9lectrique de la ligne AC220V L est interrompue, l'actionneur s'arr\u00eate et la vanne \u00e9lectrique conserve sa position actuelle.<\/li><li><strong>Si l'actionneur est \u00e9quip\u00e9 d'un d\u00e9shumidificateur de chauffage<\/strong>Si l'actionneur est en position ouverte ou ferm\u00e9e, s'assurer que la ligne AC220V L reste aliment\u00e9e apr\u00e8s avoir conduit l'actionneur en position compl\u00e8tement ouverte ou ferm\u00e9e.<\/li><\/ul><p><strong>Note<\/strong>: Le sch\u00e9ma de circuit ci-dessus montre la fonctionnalit\u00e9 de base de l'actionneur marche\/arr\u00eat (vanne \u00e9lectrique). Dans les applications pratiques, des dispositifs de protection suppl\u00e9mentaires tels que des fusibles et des limiteurs de courant doivent \u00e9galement \u00eatre envisag\u00e9s.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ad699a elementor-widget elementor-widget-heading\" data-id=\"7ad699a\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"with-switch-dc24v\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Alimentation par DC24V et contr\u00f4le par interrupteur<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-278b991 elementor-widget elementor-widget-image\" data-id=\"278b991\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"844\" height=\"330\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/08\/dc24v-switch-actuator-first-step-with-switch.webp\" class=\"attachment-full size-full wp-image-6126\" alt=\"DCL 24V \u5f00\u5173\u578b\u6267\u884c\u5668\u5e94\u7528\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2c0f56e elementor-widget elementor-widget-text-editor\" data-id=\"2c0f56e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><strong>Lorsque l'interrupteur m\u00e9canique connecte la ligne d'alimentation + \u00e0 la borne d'entr\u00e9e \"ouverte\" et la ligne d'alimentation - \u00e0 la borne d'entr\u00e9e \"ferm\u00e9e\".<\/strong>L'actionneur entra\u00eene la vanne en position ouverte. Une fois que la vanne a atteint la position d'ouverture totale, l'actionneur cesse de l'entra\u00eener et la vanne \u00e9lectrique reste enti\u00e8rement ouverte.<\/li><li><strong>Lorsque l'interrupteur m\u00e9canique connecte la ligne d'alimentation + \u00e0 la borne d'entr\u00e9e \"close\" et la ligne d'alimentation - \u00e0 la borne d'entr\u00e9e \"open\".<\/strong>L'actionneur entra\u00eene la vanne en position ferm\u00e9e. Une fois que la vanne a atteint la position de fermeture compl\u00e8te, l'actionneur s'arr\u00eate et la vanne \u00e9lectrique reste compl\u00e8tement ferm\u00e9e.<\/li><li><strong>Pendant le fonctionnement de l'actionneur<\/strong>Si l'alimentation \u00e9lectrique est interrompue, l'actionneur cesse de fonctionner et la vanne \u00e9lectrique conserve sa position actuelle.<\/li><li><strong>Si l'actionneur est \u00e9quip\u00e9 d'un d\u00e9shumidificateur de chauffage<\/strong>Si l'actionneur est en position ouverte ou ferm\u00e9e, assurez-vous que l'alimentation \u00e9lectrique reste sous tension apr\u00e8s avoir conduit l'actionneur en position compl\u00e8tement ouverte ou ferm\u00e9e.<\/li><\/ul><p><strong>Note<\/strong>: Le sch\u00e9ma de circuit ci-dessus montre la fonctionnalit\u00e9 de base de l'actionneur marche\/arr\u00eat (vanne \u00e9lectrique). Dans les applications pratiques, des dispositifs de protection suppl\u00e9mentaires tels que des fusibles et des limiteurs de courant doivent \u00e9galement \u00eatre envisag\u00e9s.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6d28c6c elementor-widget elementor-widget-heading\" data-id=\"6d28c6c\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"modulation-actuator\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Actionneur \u00e9lectrique modulant<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9016b5a elementor-widget elementor-widget-text-editor\" data-id=\"9016b5a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Lorsque vous installez un actionneur \u00e9lectrique modulant DCL (vanne) sur la canalisation, vous pouvez contr\u00f4ler la position de la vanne via des signaux analogiques 4-20mA ou 0-10V, des syst\u00e8mes de bus (tels que Modbus, CAN, Profibus, DeviceNet, Foundation Fieldbus, HART, Ethernet) ou des r\u00e9seaux IoT, ce qui permet de r\u00e9guler avec pr\u00e9cision le d\u00e9bit du fluide.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-326b679 elementor-widget elementor-widget-heading\" data-id=\"326b679\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00c9tat de l'actionneur \u00e9lectrique modulant<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2961431 elementor-widget elementor-widget-text-editor\" data-id=\"2961431\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li data-start=\"386\" data-end=\"487\"><strong data-start=\"388\" data-end=\"396\">Ouvrir<\/strong> - La vanne est partiellement ou totalement ouverte en fonction du signal de commande, ce qui permet la circulation du fluide.<\/li><li data-start=\"488\" data-end=\"608\"><strong data-start=\"490\" data-end=\"500\">Ferm\u00e9<\/strong> - La vanne est partiellement ou totalement ferm\u00e9e en fonction du signal de commande, ce qui limite ou arr\u00eate la circulation du fluide.<\/li><li data-start=\"609\" data-end=\"722\"><strong data-start=\"611\" data-end=\"628\">En transition<\/strong> - La vanne passe de la position ouverte \u00e0 la position ferm\u00e9e en fonction du signal de commande.<\/li><li data-start=\"723\" data-end=\"883\"><strong data-start=\"725\" data-end=\"740\">Erreur\/Alarme<\/strong> - L'actionneur d\u00e9tecte un probl\u00e8me tel qu'un dysfonctionnement ou une d\u00e9faillance de communication, et la vanne peut s'arr\u00eater ou ne pas atteindre la position souhait\u00e9e.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7b6a6ac e-con-full e-flex e-con e-child\" data-id=\"7b6a6ac\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-c3733d2 e-con-full e-flex e-con e-child\" data-id=\"c3733d2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5c1f25c elementor-widget elementor-widget-image\" data-id=\"5c1f25c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"422\" height=\"388\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/08\/vale-closed.webp\" class=\"attachment-full size-full wp-image-6112\" alt=\"\u7535\u52a8\u9600\u95e8\u5173\u95ed\u793a\u610f\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e096f2f e-con-full e-flex e-con e-child\" data-id=\"e096f2f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-84db4e7 elementor-widget elementor-widget-image\" data-id=\"84db4e7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"487\" height=\"378\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/08\/vale-opening.webp\" class=\"attachment-full size-full wp-image-6119\" alt=\"DCL\u6267\u884c\u5668\u5f00\u5ea6\u8c03\u8282\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-94f167e e-con-full e-flex e-con e-child\" data-id=\"94f167e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a9edcb7 elementor-widget elementor-widget-image\" data-id=\"a9edcb7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"466\" height=\"388\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/08\/vale-open.webp\" class=\"attachment-full size-full wp-image-6114\" alt=\"\u7535\u52a8\u9600\u95e8\u5168\u5f00\u793a\u610f\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9610455 elementor-widget elementor-widget-heading\" data-id=\"9610455\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"with-4-20ma\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Contr\u00f4le via 4-20mA<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-97f2bb5 elementor-widget elementor-widget-image\" data-id=\"97f2bb5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"689\" height=\"296\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/08\/servo-actuator-first-step.webp\" class=\"attachment-full size-full wp-image-6117\" alt=\"DCL\u8c03\u8282\u578b\u6267\u884c\u5668\u7b80\u8981\u5e94\u7528\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6a2a00d elementor-widget elementor-widget-text-editor\" data-id=\"6a2a00d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>L'actionneur ajuste la position de la vanne en fonction d'une relation lin\u00e9aire avec le signal d'entr\u00e9e 4-20mA :<ul><li><strong>4mA<\/strong> correspond \u00e0 la fermeture compl\u00e8te de la vanne.<\/li><li><strong>20mA<\/strong> correspond \u00e0 une ouverture totale de la vanne.<\/li><\/ul><\/li><li>Si le signal d'entr\u00e9e se situe en dehors de la plage sp\u00e9cifi\u00e9e, l'actionneur entre en mode <strong>perte de signal<\/strong> mode. En fonction des r\u00e9glages effectu\u00e9s par l'utilisateur, l'actionneur pilotera la vanne sur :<ul><li><strong>Enti\u00e8rement ouvert<\/strong>,<\/li><li><strong>Enti\u00e8rement ferm\u00e9<\/strong>ou<\/li><li><strong>Maintien de la position de la vanne<\/strong> \u00e0 l'endroit o\u00f9 le signal a \u00e9t\u00e9 perdu.<\/li><\/ul><\/li><\/ul><p><strong>Note<\/strong>: Le sch\u00e9ma de circuit ci-dessus montre la fonctionnalit\u00e9 de base d'un actionneur modulant (vanne \u00e9lectrique). Dans les applications pratiques, des dispositifs de protection suppl\u00e9mentaires tels que des fusibles et des limiteurs de courant doivent \u00e9galement \u00eatre envisag\u00e9s.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-31088d9 elementor-widget elementor-widget-heading\" data-id=\"31088d9\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"with-2-10v\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Commande par 2-10V<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f9a4b34 elementor-widget elementor-widget-image\" data-id=\"f9a4b34\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"703\" height=\"330\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/08\/servo-actuator-first-step-2-10-v.webp\" class=\"attachment-full size-full wp-image-6121\" alt=\"DCL\u8c03\u8282\u578b\u6267\u884c\u5668\u5e94\u7528\u7b80\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-84e4fa9 elementor-widget elementor-widget-text-editor\" data-id=\"84e4fa9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>L'actionneur ajuste la position de la vanne en fonction d'une relation lin\u00e9aire avec le signal d'entr\u00e9e 2-10V :<\/li><li style=\"list-style-type: none;\"><ul><li><strong>2V<\/strong> correspond \u00e0 la fermeture compl\u00e8te de la vanne.<\/li><li><strong>10V<\/strong> correspond \u00e0 une ouverture totale de la vanne.<\/li><\/ul><\/li><li>Si le signal d'entr\u00e9e d\u00e9passe ou se situe en dehors de la plage sp\u00e9cifi\u00e9e, l'actionneur entre dans le mode de fonctionnement de l'actionneur. <strong>perte de signal<\/strong> mode. En fonction des param\u00e8tres d\u00e9finis par l'utilisateur, l'actionneur actionnera la vanne \u00e0.. :<ul><li><strong>Enti\u00e8rement ouvert<\/strong>,<\/li><li><strong>Enti\u00e8rement ferm\u00e9<\/strong>ou<\/li><li><strong>Maintien de la position de la vanne<\/strong> o\u00f9 le signal a \u00e9t\u00e9 perdu.<\/li><\/ul><\/li><\/ul><p><strong>Note<\/strong>: Le sch\u00e9ma de circuit ci-dessus illustre la fonctionnalit\u00e9 de base d'un actionneur modulant (vanne \u00e9lectrique). Dans les applications r\u00e9elles, des dispositifs de protection suppl\u00e9mentaires tels que des fusibles et des limiteurs de courant doivent \u00e9galement \u00eatre envisag\u00e9s.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-34530c9 elementor-widget elementor-widget-heading\" data-id=\"34530c9\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"with-bus\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Contr\u00f4le par bus de terrain<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2844c33 elementor-widget elementor-widget-heading\" data-id=\"2844c33\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">- Modbus, CAN, Profibus, DeviceNet, Foundation Fieldbus, HART, Ethernet<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e9bd27e elementor-widget elementor-widget-image\" data-id=\"e9bd27e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1075\" height=\"597\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/08\/actuator-with-bus-application.webp\" class=\"attachment-full size-full wp-image-6129\" alt=\"\u603b\u7ebf\u578bDCL\u6267\u884c\u5668-Modbus\u3001CAN\u3001Profibus\u3001Ethernet\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a0f2acc elementor-widget elementor-widget-text-editor\" data-id=\"a0f2acc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Le syst\u00e8me de contr\u00f4le envoie une commande de contr\u00f4le de position \u00e0 l'actionneur via le protocole de communication du bus. L'actionneur conduit alors la vanne \u00e0 la position sp\u00e9cifi\u00e9e conform\u00e9ment \u00e0 la commande du bus.<\/li><li><strong>En cas d'erreur de bus<\/strong>En fonction des r\u00e9glages de l'utilisateur, l'actionneur conduira la vanne dans l'une des positions suivantes :<ul><li><strong>Enti\u00e8rement ouvert<\/strong>,<\/li><li><strong>Enti\u00e8rement ferm\u00e9<\/strong>ou<\/li><li><strong>Maintien de la position de la vanne<\/strong> au moment de l'erreur de bus.<\/li><\/ul><\/li><li>Pendant le fonctionnement de l'actionneur, si l'alimentation \u00e9lectrique est interrompue, l'actionneur s'arr\u00eate et la vanne \u00e9lectrique conserve sa position actuelle.<\/li><\/ul><p><strong>Note<\/strong>: Le sch\u00e9ma de circuit ci-dessus montre la fonctionnalit\u00e9 de base d'un actionneur modulant (vanne \u00e9lectrique). Dans les applications pratiques, des dispositifs de protection suppl\u00e9mentaires tels que des fusibles et des limiteurs de courant doivent \u00e9galement \u00eatre envisag\u00e9s.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c8901d0 elementor-widget elementor-widget-heading\" data-id=\"c8901d0\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"with-iiot\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Contr\u00f4le via IIot<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3d4b2ca elementor-widget elementor-widget-heading\" data-id=\"3d4b2ca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">- NB-Iot, LoRA, LoRaWAN, 4G<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1f5d67d elementor-widget elementor-widget-image\" data-id=\"1f5d67d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1142\" height=\"936\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/08\/actuator-iot-application.webp\" class=\"attachment-full size-full wp-image-6132\" alt=\"DCL\u6267\u884c\u5668 \u7269\u8054\u7f51\u5e94\u7528\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e97caf9 elementor-widget elementor-widget-text-editor\" data-id=\"e97caf9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><p data-start=\"67\" data-end=\"303\">Gr\u00e2ce \u00e0 la plateforme IoT de l'actionneur, les utilisateurs peuvent envoyer des commandes de contr\u00f4le de position \u00e0 l'actionneur via un ordinateur ou une application pour smartphone. Une fois que l'actionneur re\u00e7oit la commande de la plateforme IoT, il conduit la vanne \u00e0 la position sp\u00e9cifi\u00e9e.<\/p><\/li><li><p data-start=\"67\" data-end=\"303\">La plateforme IoT permet \u00e9galement de surveiller et d'enregistrer des facteurs critiques tels que la position de la vanne de l'actionneur, le couple, la dur\u00e9e de mise sous tension, la fr\u00e9quence de r\u00e9glage, etc. en particulier dans les sc\u00e9narios d'application critiques en termes de s\u00e9curit\u00e9 ou extr\u00eames.<\/p><\/li><li><p data-start=\"67\" data-end=\"303\">En outre, vous pouvez effectuer des diagnostics de d\u00e9faillance sur les actionneurs qui ne sont pas \u00e9quip\u00e9s de la fonctionnalit\u00e9 IoT. Cette application est tr\u00e8s efficace pour surveiller et d\u00e9panner les d\u00e9faillances occasionnelles dans les applications d'actionneurs.<\/p><\/li><li><p data-start=\"67\" data-end=\"303\">Pendant le fonctionnement de l'actionneur, si l'alimentation \u00e9lectrique est interrompue, l'actionneur s'arr\u00eate et la vanne \u00e9lectrique conserve sa position actuelle.<\/p><\/li><\/ul><p><strong data-start=\"917\" data-end=\"925\">Note<\/strong>: Le sch\u00e9ma de circuit ci-dessus montre la fonctionnalit\u00e9 de base d'un actionneur modulant (vanne \u00e9lectrique). Dans les applications pratiques, des dispositifs de protection suppl\u00e9mentaires tels que des fusibles et des limiteurs de courant doivent \u00e9galement \u00eatre envisag\u00e9s.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e9bffc5 e-con-full e-flex e-con e-parent\" data-id=\"e9bffc5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-d342722 e-con-full e-flex e-con e-child\" data-id=\"d342722\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-bfc64f0 e-con-full e-flex e-con e-child\" data-id=\"bfc64f0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-fed3052 e-con-full e-flex e-con e-child\" data-id=\"fed3052\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-09613e9 elementor-widget elementor-widget-heading\" data-id=\"09613e9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-heading-title elementor-size-default\"><a href=\"\/fr_fr\/soutien\/actionneur\/pourquoi-un-actionneur-electrique\/\">Previous\uff1aPourquoi choisir un actionneur \u00e9lectrique ?<\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fdbc661 e-con-full e-flex e-con e-child\" data-id=\"fdbc661\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6642692 elementor-widget elementor-widget-heading\" data-id=\"6642692\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-heading-title elementor-size-default\"><a href=\"\/fr_fr\/soutien\/actionneur\/quels-sont-les-actionneurs-dcl\/\">Next\uff1aQuel type de vannes les actionneurs \u00e9lectriques DCL peuvent-ils piloter ?<\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Une fois connect\u00e9s \u00e0 une alimentation (380 V CA, 220 V CA, 24 V CA ou 24 V CC), les actionneurs \u00e9lectriques DCL peuvent \u00eatre command\u00e9s par un syst\u00e8me de contr\u00f4le distribu\u00e9 (DCS) via diff\u00e9rents signaux de commande, notamment analogiques, num\u00e9riques, par bus et via les r\u00e9seaux IoT. L&#039;actionneur actionne la vanne \u00e9lectrique pour l&#039;ouvrir ou la fermer compl\u00e8tement, ou pour la positionner selon un r\u00e9glage pr\u00e9cis, permettant ainsi [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[99],"tags":[],"class_list":["post-10862","post","type-post","status-publish","format-standard","hentry","category-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/posts\/10862","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/comments?post=10862"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/posts\/10862\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/media?parent=10862"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/categories?post=10862"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/fr_fr\/wp-json\/wp\/v2\/tags?post=10862"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}