{"id":10800,"date":"2025-03-20T01:13:47","date_gmt":"2025-03-20T01:13:47","guid":{"rendered":"https:\/\/dclcontrols.com\/?p=10800"},"modified":"2025-03-23T06:24:09","modified_gmt":"2025-03-23T06:24:09","slug":"how-to-control-dcl-actuator-through-modbus-by-vatesttool_dcl-exe","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/fr_ca\/soutien\/comment-actionner-lactionneur\/comment-controler-un-actionneur-dcl-via-modbus-avec-lexecutable-vatesttool_dcl","title":{"rendered":"Comment contr\u00f4ler un actionneur DCL via Modbus avec vaTestTool_DCL.exe"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"10800\" class=\"elementor elementor-10800\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b21a808 e-flex e-con-boxed e-con e-parent\" data-id=\"b21a808\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-829e2a8 elementor-widget elementor-widget-heading\" data-id=\"829e2a8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">1. Ouvrez vaTestTool_DCL-v1.31.exe.<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-85a2dc1 elementor-widget elementor-widget-heading\" data-id=\"85a2dc1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">2. L&#039;application affichera une bo\u00eete de dialogue \u00ab\u00a0Se connecter \u00e0\u00a0\u00bb pour d\u00e9finir l&#039;identifiant du p\u00e9riph\u00e9rique cible et les param\u00e8tres du port RS232 de l&#039;ordinateur local comme suit.<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-64124c3 elementor-widget elementor-widget-image\" data-id=\"64124c3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/dclcontrols.com\/dam\/support\/an\/images\/connect-to-dialog.webp\" title=\"\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6fc4b4f elementor-widget elementor-widget-text-editor\" data-id=\"6fc4b4f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><i><\/i><em><i>Choisissez le port COM connect\u00e9 au connecteur USB-RS485.<\/i><\/em><\/li><li><i><\/i><em><i>S\u00e9lectionnez le d\u00e9bit de transmission Modbus (le d\u00e9bit de transmission par d\u00e9faut sur l&#039;actionneur DCL est actuellement de 9600).<\/i><\/em><\/li><li><i><\/i><em><i>Cliquez sur <\/i><\/em><em><i>\u00ab<\/i><\/em><em><i>CONNECTER<\/i><\/em><em><i>\u00ab<\/i><\/em><em><i>bouton pour connecter l&#039;actionneur.<\/i><\/em><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ae7bcf0 elementor-widget elementor-widget-image\" data-id=\"ae7bcf0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/dclcontrols.com\/dam\/support\/an\/images\/connected-to-dcl-acutator.webp\" title=\"\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bfbf3a6 elementor-widget elementor-widget-heading\" data-id=\"bfbf3a6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">3. Fermez la fen\u00eatre \u00ab\u00a0Se connecter \u00e0\u00a0\u00bb et vous vous trouvez maintenant dans la fen\u00eatre d\u2019op\u00e9ration.<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-92829e4 elementor-widget elementor-widget-image\" data-id=\"92829e4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/dclcontrols.com\/dam\/support\/an\/images\/operation-windwos2.webp\" title=\"\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b62bdce elementor-widget elementor-widget-text-editor\" data-id=\"b62bdce\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><i><\/i><em><i>Vous pouvez maintenant cliquer sur <\/i><\/em><em><i>\u00ab<\/i><\/em><em><i>OUVRIR\/FERMER\/ARR\u00caTER<\/i><\/em><em><i>\u00ab<\/i><\/em><em><i>bouton pour commander l&#039;actionneur.<\/i><\/em><\/li><li><i><\/i><em><i>Vous pouvez saisir dans <\/i><\/em><em><i>\u00ab<\/i><\/em><em><i>Position d\u00e9finie<\/i><\/em><em><i>\u00ab<\/i><\/em><em><i>cadre de texte puis cliquez sur <\/i><\/em><em><i>\u00ab<\/i><\/em><em><i>D\u00c9FINIR POS<\/i><\/em><em><i>\u00ab<\/i><\/em><em><i>\u00a0bouton permettant \u00e0 l&#039;actionneur de positionner la vanne comme vous le souhaitez.<\/i><\/em><\/li><li><i><\/i><em><i>Vous pouvez cliquer sur <\/i><\/em><em><i>\u00ab<\/i><\/em><em><i>Entr\u00e9e 4-20 mA<\/i><\/em><em><i>\u00ab<\/i><\/em><em><i>pour permettre \u00e0 l&#039;actionneur de passer en mode 4-20 mA, dans lequel l&#039;actionneur ignorera la commande modbus et utilisera le 4-20 mA comme entr\u00e9e de position.<\/i><\/em><\/li><li><i><\/i><em><i>Vous pouvez cliquer sur <\/i><\/em><em><i>\u00ab<\/i><\/em><em><i>MONITEUR<\/i><\/em><em><i>\u00ab<\/i><\/em><em><i>bouton permettant d&#039;activer ou de d\u00e9sactiver la surveillance des positions r\u00e9elles des actionneurs.<\/i><\/em><\/li><li><i><\/i><em><i>Les 4 indicateurs situ\u00e9s en haut \u00e0 droite peuvent afficher l&#039;\u00e9tat de l&#039;entr\u00e9e 4-20 mA, du protocole Modbus et la disponibilit\u00e9 de l&#039;actionneur.<\/i><\/em><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ac373a0 elementor-widget elementor-widget-heading\" data-id=\"ac373a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">4. Pour modifier le d\u00e9bit de transmission Modbus et l&#039;ID de l&#039;actionneur, cliquez sur l&#039;ic\u00f4ne d&#039;engrenage en haut \u00e0 gauche, puis une bo\u00eete de dialogue \u00ab\u00a0config\u00a0\u00bb appara\u00eetra.<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9b28356 elementor-widget elementor-widget-image\" data-id=\"9b28356\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/dclcontrols.com\/dam\/support\/an\/images\/change-modbus-para.webp\" title=\"\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e503bf9 elementor-widget elementor-widget-text-editor\" data-id=\"e503bf9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><i><\/i><em><i>D\u00e9finissez la valeur dans <\/i><\/em><em><i>\u00ab<\/i><\/em><em><i>ID de l&#039;appareil<\/i><\/em><em><i>\u00ab<\/i><\/em><em><i>et <\/i><\/em><em><i>\u00ab<\/i><\/em><em><i>Baudrate<\/i><\/em><em><i>\u00ab<\/i><\/em><em><i>\u00a0dans le groupe de dispositifs cibles, comme la configuration actuelle de l&#039;actionneur.<\/i><\/em><\/li><li><i><\/i><em><i>Saisissez les nouveaux param\u00e8tres comme vous le souhaitez dans <\/i><\/em><em><i>\u00ab<\/i><\/em><em><i>D\u00e9finir un nouveau param\u00e8tre Modbus<\/i><\/em><em><i>\u00ab<\/i><\/em><i><\/i><\/li><li><i><\/i><em><i>Cliquez sur <\/i><\/em><em><i>\u00ab<\/i><\/em><em><i>ENSEMBLE ID<\/i><\/em><em><i>\u00ab<\/i><\/em><em><i>modifier l&#039;identifiant sans modifier le d\u00e9bit en bauds.<\/i><\/em><\/li><li><i><\/i><em><i>Cliquez sur <\/i><\/em><em><i>\u00ab<\/i><\/em><em><i>D\u00c9BIT EN BAUD<\/i><\/em><em><i>\u00ab<\/i><\/em><em><i>modifier le d\u00e9bit en bauds sans modifier l&#039;identifiant.<\/i><\/em><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bd88d57 elementor-widget elementor-widget-image\" data-id=\"bd88d57\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/dclcontrols.com\/dam\/support\/an\/images\/change-modbus-para-done.webp\" title=\"\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>1.Open vaTestTool_DCL-v1.31.exe. 2.The application will popup a \u201cConnect to\u201d dialog to set the target device id and local computer RS232 port parameters as follow. Choose the COM port which connected to the USB-RS485 connector. Select the modbus baud rate (the default baudrate on DCL actuator now is 9600). Click on \u201cCONNECT\u201dbutton to connect to the [&hellip;]<\/p>","protected":false},"author":1,"featured_media":10942,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[100],"tags":[53],"class_list":["post-10800","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-how-to-actuator","tag-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/fr_ca\/wp-json\/wp\/v2\/posts\/10800","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/fr_ca\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/fr_ca\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/fr_ca\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/fr_ca\/wp-json\/wp\/v2\/comments?post=10800"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/fr_ca\/wp-json\/wp\/v2\/posts\/10800\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/fr_ca\/wp-json\/wp\/v2\/media\/10942"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/fr_ca\/wp-json\/wp\/v2\/media?parent=10800"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/fr_ca\/wp-json\/wp\/v2\/categories?post=10800"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/fr_ca\/wp-json\/wp\/v2\/tags?post=10800"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}