{"id":5308,"date":"2023-05-25T14:38:18","date_gmt":"2023-05-25T06:38:18","guid":{"rendered":"http:\/\/www.dcl-controls.com\/?p=5308"},"modified":"2025-03-23T06:24:19","modified_gmt":"2025-03-23T06:24:19","slug":"set-up-dcl-actuator","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/es_mx\/apoyo\/como-funciona-el-actuador\/configurar-el-actuador-dcl","title":{"rendered":"\u00bfC\u00f3mo configurar una v\u00e1lvula el\u00e9ctrica modulante?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"5308\" class=\"elementor elementor-5308\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c3b7996 e-con-full e-flex e-con e-child\" data-id=\"c3b7996\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-11d7691 elementor-widget elementor-widget-heading\" data-id=\"11d7691\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">1. Instalaci\u00f3n del actuador en la v\u00e1lvula<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9720240 elementor-widget elementor-widget-text-editor\" data-id=\"9720240\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Siga las instrucciones de instalaci\u00f3n en <strong data-start=\"145\" data-end=\"193\">\u201cC\u00f3mo instalar el actuador en la v\u00e1lvula\u201d<\/strong> Para instalar correctamente el actuador en la v\u00e1lvula, confirme su funcionamiento normal comprobando manualmente el movimiento de la v\u00e1lvula.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ea3a72d elementor-widget elementor-widget-heading\" data-id=\"ea3a72d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2. Ajuste de los l\u00edmites mec\u00e1nicos para la posici\u00f3n completamente cerrada.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f43def1 elementor-widget elementor-widget-text-editor\" data-id=\"f43def1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li class=\"\" data-start=\"380\" data-end=\"532\"><p class=\"\" data-start=\"382\" data-end=\"532\">Utilice el volante para mover la v\u00e1lvula a la <strong data-start=\"425\" data-end=\"450\">posici\u00f3n totalmente cerrada<\/strong>Aseg\u00farese de que el tope mec\u00e1nico no toque el tornillo de ajuste ni la carcasa.<\/p><\/li><li class=\"\" data-start=\"533\" data-end=\"706\"><p class=\"\" data-start=\"535\" data-end=\"706\">Aflojar el <strong data-start=\"546\" data-end=\"575\">tornillo de bloqueo de la placa de escala<\/strong>, ajuste la placa de escala de modo que el puntero se alinee con el <strong data-start=\"636\" data-end=\"653\">marca de 0 grados<\/strong> (posici\u00f3n CERRADA) y, a continuaci\u00f3n, apriete el tornillo de bloqueo.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c4faa9b elementor-widget elementor-widget-heading\" data-id=\"c4faa9b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">3. Ajuste de los l\u00edmites mec\u00e1nicos para la posici\u00f3n totalmente abierta.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-69328ab elementor-widget elementor-widget-text-editor\" data-id=\"69328ab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul data-start=\"778\" data-end=\"1048\"><li class=\"\" data-start=\"778\" data-end=\"928\"><p class=\"\" data-start=\"780\" data-end=\"928\">Utilice el volante para mover la v\u00e1lvula a la <strong data-start=\"823\" data-end=\"846\">puesto totalmente vacante<\/strong>Aseg\u00farese de que el tope mec\u00e1nico no toque el tornillo de ajuste ni la carcasa.<\/p><\/li><li class=\"\" data-start=\"929\" data-end=\"1048\"><p class=\"\" data-start=\"931\" data-end=\"1048\">Si la carrera de la v\u00e1lvula es de 90\u00b0, el puntero debe alinearse con el <strong data-start=\"995\" data-end=\"1012\">marca de 0 grados<\/strong> (Posici\u00f3n ABIERTA) en la placa de la escala.<\/p><\/li><\/ul><p class=\"\" data-start=\"1050\" data-end=\"1072\"><strong data-start=\"1050\" data-end=\"1070\">Notas importantes:<\/strong><\/p><ul data-start=\"1073\" data-end=\"1878\"><li class=\"\" data-start=\"1073\" data-end=\"1230\"><p class=\"\" data-start=\"1075\" data-end=\"1230\">A menos que se especifique lo contrario, durante la depuraci\u00f3n en f\u00e1brica, el \u00e1ngulo de carrera del actuador entre las posiciones completamente cerrada y completamente abierta es t\u00edpicamente <strong data-start=\"1220\" data-end=\"1227\">90\u00b0<\/strong>.<\/p><\/li><li class=\"\" data-start=\"1231\" data-end=\"1447\"><p class=\"\" data-start=\"1233\" data-end=\"1447\">Tras la calibraci\u00f3n de las v\u00e1lvulas, si las posiciones de apertura y cierre total del actuador no coinciden con las de la v\u00e1lvula, se deben realizar ajustes. Aseg\u00farese de que los l\u00edmites mec\u00e1nicos est\u00e9n configurados como se muestra en el diagrama a continuaci\u00f3n.<\/p><\/li><li class=\"\" data-start=\"1448\" data-end=\"1665\"><p class=\"\" data-start=\"1450\" data-end=\"1665\">Todos los actuadores modulantes (tipo E) ya tienen en cuenta las posibles variaciones en el rango de funcionamiento del potenci\u00f3metro durante el ajuste de las v\u00e1lvulas. Por lo tanto, generalmente no se requieren ajustes en el potenci\u00f3metro ni en los engranajes.<\/p><\/li><li class=\"\" data-start=\"1666\" data-end=\"1878\"><p class=\"\" data-start=\"1668\" data-end=\"1878\">Los terminales de cableado deben conectarse correctamente como se muestra en el diagrama para evitar da\u00f1ar el controlador del servo. No conecte el <strong data-start=\"1798\" data-end=\"1809\">&quot;fuerza&quot;<\/strong> terminal al <strong data-start=\"1826\" data-end=\"1844\">\u201cse\u00f1al de entrada\u201d<\/strong> o <strong data-start=\"1848\" data-end=\"1867\">\u201cse\u00f1al de salida\u201d<\/strong> terminales.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-752675b elementor-widget elementor-widget-image\" data-id=\"752675b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"271\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/position-limiter-setting-cn.webp\" class=\"attachment-full size-full wp-image-5316\" alt=\"\u534e\u6613\u79d1\u6280 \u673a\u68b0\u7535\u6c14\u9650\u4f4d\u5173\u7cfb \u793a\u610f\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6ae7eee elementor-widget elementor-widget-heading\" data-id=\"6ae7eee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">4. Explicaci\u00f3n del panel de control del servomotor<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b3a45f5 e-con-full e-flex e-con e-child\" data-id=\"b3a45f5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-b6af4cd e-con-full e-flex e-con e-child\" data-id=\"b6af4cd\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b5e8e96 elementor-widget elementor-widget-image\" data-id=\"b5e8e96\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"600\" height=\"599\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/sf-lc-servo-control-pack-cn.webp\" class=\"attachment-full size-full wp-image-5318\" alt=\"\u534e\u6613\u79d1\u6280\u7535\u52a8\u6267\u884c\u5668 LC\u63a7\u5236\u6a21\u5757 \u63a5\u53e3\u793a\u610f\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4f5c1c9 e-con-full e-flex e-con e-child\" data-id=\"4f5c1c9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-144627d elementor-widget elementor-widget-image\" data-id=\"144627d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"600\" height=\"606\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/sf-zc-servo-control-pack-cn.webp\" class=\"attachment-full size-full wp-image-5320\" alt=\"\u534e\u6613\u79d1\u6280\u7535\u52a8\u9600 \u63a7\u5236\u6a21\u5757 \u63a5\u53e3\u793a\u610f\u56fe\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1bbbb68 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"1bbbb68\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"1933\" data-end=\"1951\"><strong data-start=\"1933\" data-end=\"1951\">Funciones clave:<\/strong><\/p><ul data-start=\"1952\" data-end=\"2214\"><li class=\"\" data-start=\"1952\" data-end=\"2036\"><p class=\"\" data-start=\"1954\" data-end=\"2036\"><strong data-start=\"1954\" data-end=\"1963\">Abierto:<\/strong> En <strong data-start=\"1967\" data-end=\"1982\">\u201cEstablecer estado\u201d<\/strong>Pulse esta tecla para abrir la v\u00e1lvula. Su\u00e9ltela para detenerla.<\/p><\/li><li class=\"\" data-start=\"2037\" data-end=\"2122\"><p class=\"\" data-start=\"2039\" data-end=\"2122\"><strong data-start=\"2039\" data-end=\"2048\">Cerrar:<\/strong> En <strong data-start=\"2052\" data-end=\"2067\">\u201cEstablecer estado\u201d<\/strong>Pulse esta tecla para cerrar la v\u00e1lvula. Su\u00e9ltela para detenerla.<\/p><\/li><li class=\"\" data-start=\"2123\" data-end=\"2214\"><p class=\"\" data-start=\"2125\" data-end=\"2214\"><strong data-start=\"2125\" data-end=\"2133\">Colocar:<\/strong> En <strong data-start=\"2137\" data-end=\"2152\">\u201cEstablecer estado\u201d<\/strong>, usar con <strong data-start=\"2163\" data-end=\"2171\">Abierto<\/strong> o <strong data-start=\"2175\" data-end=\"2183\">Cerrar<\/strong> para lograr funciones espec\u00edficas.<\/p><\/li><\/ul><p class=\"\" data-start=\"2216\" data-end=\"2239\"><strong data-start=\"2216\" data-end=\"2239\">Interruptores de selecci\u00f3n:<\/strong><\/p><ul data-start=\"2240\" data-end=\"2661\"><li class=\"\" data-start=\"2240\" data-end=\"2485\"><p class=\"\" data-start=\"2242\" data-end=\"2404\"><strong data-start=\"2242\" data-end=\"2268\">SA (Selecci\u00f3n de Se\u00f1al):<\/strong> Utilice el interruptor para seleccionar el tipo de se\u00f1al de entrada (directa o inversa) y configurar el estado. Aseg\u00farese de que el dispositivo est\u00e9 encendido para que los cambios surtan efecto.<\/p><ul data-start=\"2407\" data-end=\"2485\"><li class=\"\" data-start=\"2407\" data-end=\"2432\"><p class=\"\" data-start=\"2409\" data-end=\"2432\"><strong data-start=\"2409\" data-end=\"2414\">1<\/strong> \u2013 Acci\u00f3n directa<\/p><\/li><li class=\"\" data-start=\"2435\" data-end=\"2456\"><p class=\"\" data-start=\"2437\" data-end=\"2456\"><strong data-start=\"2437\" data-end=\"2442\">2<\/strong> \u2013 Establecer estado<\/p><\/li><li class=\"\" data-start=\"2459\" data-end=\"2485\"><p class=\"\" data-start=\"2461\" data-end=\"2485\"><strong data-start=\"2461\" data-end=\"2466\">3<\/strong> \u2013 Acci\u00f3n inversa<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"2486\" data-end=\"2661\"><p class=\"\" data-start=\"2488\" data-end=\"2560\"><strong data-start=\"2488\" data-end=\"2521\">SB (Gesti\u00f3n de fallos de se\u00f1al):<\/strong> Seleccione c\u00f3mo gestionar el fallo de la se\u00f1al.<\/p><ul data-start=\"2563\" data-end=\"2661\"><li class=\"\" data-start=\"2563\" data-end=\"2591\"><p class=\"\" data-start=\"2565\" data-end=\"2591\"><strong data-start=\"2565\" data-end=\"2570\">1<\/strong> \u2013 V\u00e1lvula completamente abierta<\/p><\/li><li class=\"\" data-start=\"2594\" data-end=\"2630\"><p class=\"\" data-start=\"2596\" data-end=\"2630\"><strong data-start=\"2596\" data-end=\"2601\">2<\/strong> \u2013 La v\u00e1lvula mantiene la posici\u00f3n<\/p><\/li><li class=\"\" data-start=\"2633\" data-end=\"2661\"><p class=\"\" data-start=\"2635\" data-end=\"2661\"><strong data-start=\"2635\" data-end=\"2640\">3<\/strong> \u2013 V\u00e1lvula completamente cerrada<\/p><\/li><\/ul><\/li><\/ul><p class=\"\" data-start=\"2663\" data-end=\"2700\"><strong data-start=\"2663\" data-end=\"2698\">Potenci\u00f3metro de ajuste de la zona muerta:<\/strong><\/p><ul data-start=\"2701\" data-end=\"2838\"><li class=\"\" data-start=\"2701\" data-end=\"2838\"><p class=\"\" data-start=\"2703\" data-end=\"2838\">Ajuste el valor de la banda muerta desde <strong data-start=\"2734\" data-end=\"2750\">0,5% a 5,0%<\/strong> (configuraci\u00f3n predeterminada de f\u00e1brica en <strong data-start=\"2775\" data-end=\"2783\">1.5%<\/strong>). Cada ajuste incrementa la banda muerta en <strong data-start=\"2829\" data-end=\"2837\">0.5%<\/strong>.<\/p><\/li><\/ul><p class=\"\" data-start=\"2840\" data-end=\"2857\"><strong data-start=\"2840\" data-end=\"2855\">Indicadores:<\/strong><\/p><ul data-start=\"2858\" data-end=\"3262\"><li class=\"\" data-start=\"2858\" data-end=\"2937\"><p class=\"\" data-start=\"2860\" data-end=\"2937\"><strong data-start=\"2860\" data-end=\"2875\">L1 (Verde):<\/strong> Indicador de encendido (se ilumina cuando el controlador est\u00e1 encendido).<\/p><\/li><li class=\"\" data-start=\"2938\" data-end=\"3024\"><p class=\"\" data-start=\"2940\" data-end=\"3024\"><strong data-start=\"2940\" data-end=\"2953\">L2 (Rojo):<\/strong> Indicador de fallo de la se\u00f1al de entrada (se ilumina cuando falla la se\u00f1al de entrada).<\/p><\/li><li class=\"\" data-start=\"3025\" data-end=\"3169\"><p class=\"\" data-start=\"3027\" data-end=\"3169\"><strong data-start=\"3027\" data-end=\"3040\">L3 (Rojo):<\/strong> Indicador de fallo del circuito de detecci\u00f3n de posici\u00f3n (se enciende cuando hay un problema con el cableado o el componente del potenci\u00f3metro de posici\u00f3n).<\/p><\/li><li class=\"\" data-start=\"3170\" data-end=\"3262\"><p class=\"\" data-start=\"3172\" data-end=\"3262\"><strong data-start=\"3172\" data-end=\"3185\">L4 (Rojo):<\/strong> Indicador de fallo por atasco mec\u00e1nico (se enciende cuando hay un atasco en el mecanismo).<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-355ac67 elementor-widget elementor-widget-heading\" data-id=\"355ac67\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">5. Configuraci\u00f3n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fef02da elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"fef02da\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"3291\" data-end=\"3316\"><strong data-start=\"3291\" data-end=\"3314\">Entrando en el estado establecido:<\/strong><\/p><ul data-start=\"3317\" data-end=\"3539\"><li class=\"\" data-start=\"3317\" data-end=\"3539\"><p class=\"\" data-start=\"3319\" data-end=\"3539\">Establecer el <strong data-start=\"3327\" data-end=\"3340\">Interruptor SA<\/strong> posicionar <strong data-start=\"3353\" data-end=\"3358\">2<\/strong>, entrando en el <strong data-start=\"3373\" data-end=\"3386\">Establecer estado<\/strong>donde se pueden configurar funciones como la calibraci\u00f3n de carrera, el manejo de fallas de se\u00f1al, el ajuste de banda muerta, el funcionamiento manual y la calibraci\u00f3n de corriente de salida.<\/p><\/li><\/ul><p class=\"\" data-start=\"3541\" data-end=\"3564\"><strong data-start=\"3541\" data-end=\"3564\">Calibraci\u00f3n de carrera:<\/strong><\/p><ul data-start=\"3565\" data-end=\"4167\"><li class=\"\" data-start=\"3565\" data-end=\"3870\"><p class=\"\" data-start=\"3567\" data-end=\"3598\"><strong data-start=\"3567\" data-end=\"3596\">Calibraci\u00f3n completamente cerrada:<\/strong><\/p><ul data-start=\"3601\" data-end=\"3870\"><li class=\"\" data-start=\"3601\" data-end=\"3867\"><p class=\"\" data-start=\"3603\" data-end=\"3867\">Usar <strong data-start=\"3607\" data-end=\"3615\">Abierto<\/strong> o <strong data-start=\"3619\" data-end=\"3627\">Cerrar<\/strong> para mover la v\u00e1lvula a la posici\u00f3n completamente cerrada. Mantenga presionado el <strong data-start=\"3695\" data-end=\"3702\">Colocar<\/strong> bot\u00f3n, luego presione <strong data-start=\"3722\" data-end=\"3730\">Cerrar<\/strong>Mant\u00e9n pulsados ambos botones durante aproximadamente <strong data-start=\"3768\" data-end=\"3781\">4 segundos<\/strong> hasta <strong data-start=\"3788\" data-end=\"3794\">L2<\/strong> Se ilumina. Suelte ambos botones para completar la calibraci\u00f3n cerrada.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"3871\" data-end=\"4167\"><p class=\"\" data-start=\"3873\" data-end=\"3902\"><strong data-start=\"3873\" data-end=\"3900\">Calibraci\u00f3n totalmente abierta:<\/strong><\/p><ul data-start=\"3905\" data-end=\"4167\"><li class=\"\" data-start=\"3905\" data-end=\"4167\"><p class=\"\" data-start=\"3907\" data-end=\"4167\">Usar <strong data-start=\"3911\" data-end=\"3919\">Abierto<\/strong> o <strong data-start=\"3923\" data-end=\"3931\">Cerrar<\/strong> para mover la v\u00e1lvula a la posici\u00f3n completamente abierta. Mantenga presionado el <strong data-start=\"3997\" data-end=\"4004\">Colocar<\/strong> bot\u00f3n, luego presione <strong data-start=\"4024\" data-end=\"4032\">Abierto<\/strong>Mant\u00e9n pulsados ambos botones durante aproximadamente <strong data-start=\"4070\" data-end=\"4083\">4 segundos<\/strong> hasta <strong data-start=\"4090\" data-end=\"4096\">L2<\/strong> Se ilumina. Suelte ambos botones para completar la calibraci\u00f3n de apertura total.<\/p><\/li><\/ul><\/li><\/ul><p class=\"\" data-start=\"4169\" data-end=\"4205\"><strong data-start=\"4169\" data-end=\"4203\">Manejo de fallas en la se\u00f1al de entrada:<\/strong><\/p><ul data-start=\"4206\" data-end=\"4511\"><li class=\"\" data-start=\"4206\" data-end=\"4391\"><p class=\"\" data-start=\"4208\" data-end=\"4292\">Utilice el <strong data-start=\"4216\" data-end=\"4229\">Interruptor SB<\/strong> para seleccionar c\u00f3mo debe el sistema gestionar el fallo de la se\u00f1al de entrada:<\/p><ul data-start=\"4295\" data-end=\"4391\"><li class=\"\" data-start=\"4295\" data-end=\"4323\"><p class=\"\" data-start=\"4297\" data-end=\"4323\"><strong data-start=\"4297\" data-end=\"4302\">1<\/strong> \u2013 V\u00e1lvula completamente abierta<\/p><\/li><li class=\"\" data-start=\"4326\" data-end=\"4358\"><p class=\"\" data-start=\"4328\" data-end=\"4358\"><strong data-start=\"4328\" data-end=\"4333\">2<\/strong> \u2013 La v\u00e1lvula mantiene la posici\u00f3n<\/p><\/li><li class=\"\" data-start=\"4361\" data-end=\"4391\"><p class=\"\" data-start=\"4363\" data-end=\"4391\"><strong data-start=\"4363\" data-end=\"4368\">3<\/strong> \u2013 V\u00e1lvula completamente cerrada<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"4392\" data-end=\"4511\"><p class=\"\" data-start=\"4394\" data-end=\"4511\">Nota: Cambiar el <strong data-start=\"4413\" data-end=\"4426\">Interruptor SB<\/strong> es eficaz incluso durante el funcionamiento autom\u00e1tico (cuando <strong data-start=\"4478\" data-end=\"4484\">Sud\u00e1frica<\/strong> est\u00e1 configurado para <strong data-start=\"4495\" data-end=\"4500\">1<\/strong> o <strong data-start=\"4504\" data-end=\"4509\">3<\/strong>).<\/p><\/li><\/ul><p class=\"\" data-start=\"4513\" data-end=\"4542\"><strong data-start=\"4513\" data-end=\"4540\">Configuraci\u00f3n del valor de la banda muerta:<\/strong><\/p><ul data-start=\"4543\" data-end=\"4737\"><li class=\"\" data-start=\"4543\" data-end=\"4737\"><p class=\"\" data-start=\"4545\" data-end=\"4737\">Gira el <strong data-start=\"4556\" data-end=\"4582\">potenci\u00f3metro de banda muerta<\/strong> En el sentido de las agujas del reloj para aumentar la banda muerta y en el sentido contrario a las agujas del reloj para disminuirla. Cada incremento cambia la banda muerta en <strong data-start=\"4695\" data-end=\"4703\">0.5%<\/strong>. El valor predeterminado de f\u00e1brica es <strong data-start=\"4728\" data-end=\"4736\">1.5%<\/strong>.<\/p><\/li><\/ul><p class=\"\" data-start=\"4739\" data-end=\"4837\">Puede abrir o cerrar manualmente la v\u00e1lvula usando el <strong data-start=\"4790\" data-end=\"4798\">Abierto<\/strong> o <strong data-start=\"4802\" data-end=\"4810\">Cerrar<\/strong> llaves en el <strong data-start=\"4823\" data-end=\"4836\">Establecer estado<\/strong>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80849e9 elementor-widget elementor-widget-heading\" data-id=\"80849e9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">6. Operaci\u00f3n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-422d8e7 elementor-widget elementor-widget-text-editor\" data-id=\"422d8e7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"4867\" data-end=\"4902\"><strong data-start=\"4867\" data-end=\"4900\">Entrando en funcionamiento autom\u00e1tico:<\/strong><\/p><ul data-start=\"4903\" data-end=\"5074\"><li class=\"\" data-start=\"4903\" data-end=\"5074\"><p class=\"\" data-start=\"4905\" data-end=\"5074\">Establecer el <strong data-start=\"4913\" data-end=\"4926\">Interruptor SA<\/strong> a <strong data-start=\"4930\" data-end=\"4935\">1<\/strong> o <strong data-start=\"4939\" data-end=\"4944\">3<\/strong> para entrar <strong data-start=\"4954\" data-end=\"4977\">Funcionamiento autom\u00e1tico<\/strong>En este modo, la posici\u00f3n del actuador y la se\u00f1al de salida siguen los cambios en la se\u00f1al de entrada.<\/p><\/li><\/ul><p class=\"\" data-start=\"5076\" data-end=\"5087\"><strong data-start=\"5076\" data-end=\"5085\">Nota:<\/strong><\/p><ul data-start=\"5088\" data-end=\"5362\"><li class=\"\" data-start=\"5088\" data-end=\"5225\"><p class=\"\" data-start=\"5090\" data-end=\"5225\">En <strong data-start=\"5093\" data-end=\"5111\">Acci\u00f3n inversa<\/strong>, a <strong data-start=\"5115\" data-end=\"5122\">4 mA<\/strong> La entrada corresponde a una <strong data-start=\"5146\" data-end=\"5154\">100%<\/strong> apertura de la v\u00e1lvula, mientras que una <strong data-start=\"5178\" data-end=\"5186\">20 mA<\/strong> La entrada corresponde a una <strong data-start=\"5210\" data-end=\"5216\">0%<\/strong> apertura.<\/p><\/li><li class=\"\" data-start=\"5226\" data-end=\"5362\"><p class=\"\" data-start=\"5228\" data-end=\"5362\">El controlador servo tiene un nivel de precisi\u00f3n de <strong data-start=\"5274\" data-end=\"5285\">Clase 1<\/strong>, con un error b\u00e1sico de no m\u00e1s de <strong data-start=\"5322\" data-end=\"5329\">\u00b11%<\/strong> y la hist\u00e9resis es menor que <strong data-start=\"5355\" data-end=\"5361\">1%<\/strong>.<\/p><\/li><\/ul><p class=\"\" data-start=\"5364\" data-end=\"5402\"><strong data-start=\"5364\" data-end=\"5402\">Corriente de salida frente a la posici\u00f3n de la v\u00e1lvula:<\/strong><\/p><div class=\"overflow-x-auto contain-inline-size\"><table data-start=\"5404\" data-end=\"5655\"><thead data-start=\"5404\" data-end=\"5465\"><tr data-start=\"5404\" data-end=\"5465\"><th data-start=\"5404\" data-end=\"5419\">Se\u00f1al de entrada<\/th><th data-start=\"5419\" data-end=\"5428\">4 mA<\/th><th data-start=\"5428\" data-end=\"5437\">8 mA<\/th><th data-start=\"5437\" data-end=\"5446\">12 mA<\/th><th data-start=\"5446\" data-end=\"5455\">16 mA<\/th><th data-start=\"5455\" data-end=\"5465\">20 mA<\/th><\/tr><\/thead><tbody data-start=\"5528\" data-end=\"5655\"><tr data-start=\"5528\" data-end=\"5591\"><td>Posici\u00f3n de la v\u00e1lvula<\/td><td>0%<\/td><td>25%<\/td><td>50%<\/td><td>75%<\/td><td>100%<\/td><\/tr><tr data-start=\"5592\" data-end=\"5655\"><td>Corriente de salida<\/td><td>4 mA<\/td><td>8 mA<\/td><td>12 mA<\/td><td>16 mA<\/td><td>20 mA<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d54eb82 elementor-widget elementor-widget-heading\" data-id=\"d54eb82\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">7. Calibraci\u00f3n de la corriente de salida<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-669115e elementor-widget elementor-widget-text-editor\" data-id=\"669115e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"5702\" data-end=\"5963\"><strong data-start=\"5702\" data-end=\"5726\">Calibraci\u00f3n de f\u00e1brica:<\/strong><br data-start=\"5726\" data-end=\"5729\" \/>El controlador del servomotor viene calibrado de f\u00e1brica, por lo que normalmente no se requieren ajustes por parte del usuario. Sin embargo, si la corriente de salida en las posiciones completamente cerrada (4 mA) o completamente abierta (20 mA) se desv\u00eda en m\u00e1s de <strong data-start=\"5926\" data-end=\"5932\">1%<\/strong>Es posible que necesites calibrarlo.<\/p><p class=\"\" data-start=\"5965\" data-end=\"5987\"><strong data-start=\"5965\" data-end=\"5987\">Pasos de calibraci\u00f3n:<\/strong><\/p><ol data-start=\"5988\" data-end=\"6547\"><li class=\"\" data-start=\"5988\" data-end=\"6035\"><p class=\"\" data-start=\"5991\" data-end=\"6035\">Conectar un <strong data-start=\"6001\" data-end=\"6020\">amper\u00edmetro de CC de 20 mA<\/strong> a la salida.<\/p><\/li><li class=\"\" data-start=\"6036\" data-end=\"6095\"><p class=\"\" data-start=\"6039\" data-end=\"6095\">Establecer el <strong data-start=\"6047\" data-end=\"6060\">Interruptor SA<\/strong> a <strong data-start=\"6064\" data-end=\"6069\">2<\/strong> para entrar <strong data-start=\"6079\" data-end=\"6092\">Establecer estado<\/strong>.<\/p><\/li><li class=\"\" data-start=\"6096\" data-end=\"6196\"><p class=\"\" data-start=\"6099\" data-end=\"6196\">Mant\u00e9n pulsado el <strong data-start=\"6118\" data-end=\"6125\">Colocar<\/strong> bot\u00f3n, luego presione simult\u00e1neamente el <strong data-start=\"6164\" data-end=\"6172\">Abierto<\/strong> y <strong data-start=\"6177\" data-end=\"6185\">Cerrar<\/strong> botones.<\/p><\/li><li class=\"\" data-start=\"6197\" data-end=\"6358\"><p class=\"\" data-start=\"6200\" data-end=\"6358\">Cuando <strong data-start=\"6205\" data-end=\"6211\">L2<\/strong> Se iluminan, suelte todos los botones y el sistema entrar\u00e1 <strong data-start=\"6270\" data-end=\"6289\">Calibraci\u00f3n de 4 mA<\/strong>. Ajuste la corriente a <strong data-start=\"6313\" data-end=\"6320\">4 mA<\/strong> usando el <strong data-start=\"6331\" data-end=\"6339\">Abierto<\/strong> y <strong data-start=\"6344\" data-end=\"6352\">Cerrar<\/strong> llaves.<\/p><\/li><li class=\"\" data-start=\"6359\" data-end=\"6547\"><p class=\"\" data-start=\"6362\" data-end=\"6547\">Despu\u00e9s de completar el <strong data-start=\"6383\" data-end=\"6402\">Calibraci\u00f3n de 4 mA<\/strong>, presione y mantenga presionado <strong data-start=\"6419\" data-end=\"6426\">Colocar<\/strong> de nuevo y esperar <strong data-start=\"6446\" data-end=\"6452\">L2<\/strong> para encenderlo. Luego su\u00e9ltalo para entrar <strong data-start=\"6491\" data-end=\"6511\">Calibraci\u00f3n de 20 mA<\/strong> y ajustar la corriente a <strong data-start=\"6538\" data-end=\"6546\">20 mA<\/strong>.<\/p><\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-64cb79a elementor-widget elementor-widget-heading\" data-id=\"64cb79a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">8. Diagn\u00f3stico de fallas y soluci\u00f3n de problemas<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cf7d399 elementor-widget elementor-widget-text-editor\" data-id=\"cf7d399\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"flex max-w-full flex-col flex-grow\"><div class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 whitespace-normal break-words text-start [.text-message+&amp;]:mt-5\" dir=\"auto\" data-message-author-role=\"assistant\" data-message-id=\"1cd8ba4b-b609-46a1-82a1-72b8dd7af669\" data-message-model-slug=\"gpt-4o-mini\"><div class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[3px]\"><div class=\"markdown prose w-full break-words dark:prose-invert light\"><p class=\"\" data-start=\"6603\" data-end=\"6630\"><strong data-start=\"6603\" data-end=\"6630\">Luces indicadoras de aver\u00eda:<\/strong><\/p><ul data-start=\"6631\" data-end=\"7071\"><li class=\"\" data-start=\"6631\" data-end=\"6844\"><p class=\"\" data-start=\"6633\" data-end=\"6709\"><strong data-start=\"6633\" data-end=\"6650\">Se encienden las luces L2:<\/strong><br data-start=\"6650\" data-end=\"6653\" \/>Fallo en la se\u00f1al de entrada: compruebe la tensi\u00f3n de la se\u00f1al de entrada.<\/p><ul data-start=\"6712\" data-end=\"6844\"><li class=\"\" data-start=\"6712\" data-end=\"6841\"><p class=\"\" data-start=\"6714\" data-end=\"6841\">Si el voltaje es anormal (fuera del rango de 0,88-4,4 V), compruebe si hay circuitos abiertos, cortocircuitos o fuentes de se\u00f1al incorrectas.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"6845\" data-end=\"6978\"><p class=\"\" data-start=\"6847\" data-end=\"6978\"><strong data-start=\"6847\" data-end=\"6864\">Se encienden las luces del nivel 3:<\/strong><br data-start=\"6864\" data-end=\"6867\" \/>Fallo en la detecci\u00f3n de posici\u00f3n: compruebe si el potenci\u00f3metro presenta problemas como circuitos abiertos, cortocircuitos o da\u00f1os.<\/p><\/li><li class=\"\" data-start=\"6982\" data-end=\"7071\"><p class=\"\" data-start=\"6984\" data-end=\"7071\"><strong data-start=\"6984\" data-end=\"7001\">Se encienden las luces del nivel 4:<\/strong><br data-start=\"7001\" data-end=\"7004\" \/>Atascamiento mec\u00e1nico: compruebe que no haya atascos en las conexiones del motor ni en el actuador.<\/p><\/li><\/ul><p class=\"\" data-start=\"7073\" data-end=\"7314\"><strong data-start=\"7073\" data-end=\"7103\">Desajuste entre v\u00e1lvula y se\u00f1al:<\/strong><br data-start=\"7103\" data-end=\"7106\" \/>Si el recorrido del actuador no coincide con la se\u00f1al de entrada, o si el actuador no puede completar su recorrido total, puede indicar un problema con el controlador del servomotor o con el circuito del potenci\u00f3metro de ajuste de la zona muerta.<\/p><p class=\"\" data-start=\"7316\" data-end=\"7402\">Para obtener m\u00e1s ayuda, siga los pasos de soluci\u00f3n de problemas que se describen para cada c\u00f3digo de error.<\/p><\/div><\/div><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>1. Installing the Actuator onto the Valve Follow the installation instructions in &#8220;How to Install the Actuator onto the Valve&#8221; to correctly install the actuator on the valve. Confirm normal operation by manually testing the valve movement. 2. Adjusting the Mechanical Limits for Fully Closed Position Use the handwheel to move the valve to the [&hellip;]<\/p>","protected":false},"author":1,"featured_media":10944,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[100],"tags":[53],"class_list":["post-5308","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-how-to-actuator","tag-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/es_mx\/wp-json\/wp\/v2\/posts\/5308","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/es_mx\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/es_mx\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/es_mx\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/es_mx\/wp-json\/wp\/v2\/comments?post=5308"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/es_mx\/wp-json\/wp\/v2\/posts\/5308\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/es_mx\/wp-json\/wp\/v2\/media\/10944"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/es_mx\/wp-json\/wp\/v2\/media?parent=5308"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/es_mx\/wp-json\/wp\/v2\/categories?post=5308"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/es_mx\/wp-json\/wp\/v2\/tags?post=5308"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}