Cómo controlar el actuador DCL a través de Modbus con vaTestTool_DCL.exe

Cómo controlar el actuador DCL a través de Modbus con vaTestTool_DCL.exe

1.Open vaTestTool_DCL-v1.31.exe. 2.The application will popup a “Connect to” dialog to set the target device id and local computer RS232 port parameters as follow. Choose the COM port which connected to the USB-RS485 connector. Select the modbus baud rate (the default baudrate on DCL actuator now is 9600). Click on “CONNECT”button to connect to the […]

¿Cómo elegir un actuador?

Determining Specific Valve Drive Parameters For precise fluid control applications, it is essential to define the final valve drive parameters based on factors such as fluid pressure, media type, and control method. This ensures that the selected electric actuator meets the operational requirements. The following parameters should be determined before finalizing the actuator model: Choose […]

Manual de usuario del actuador DCL con FSR

Actuador DCL con panel de control FSR Conexión P1: Alimentación DC24V + P3: Alimentación DC24V – P5: Entrada 4-20mA – P7: Entrada 4-20mA + P9: Salida 4-20mA – P11: Salida 4-20mA + P2: Entrada ON/OFF COM P4: Entrada ON/OFF abierta P6: Entrada ON/OFF cerrada P8: Salida ON/OFF COM P10: Salida ON/OFF abierta P12: Salida ON/OFF cerrada Botón KO: Se utiliza en el modo de configuración. Pulse este botón para abrir el […]

Manual de aplicación Modbus para actuadores DCL (versión Envision)

Servicio y soporte Los actuadores de la serie DCL son compatibles con el protocolo Modbus-RTU. Consultando este manual de aplicación, puede conectar el actuador DCL a Modbus. Descripción del panel 1. Definición de la interfaz P1: Neutro (N) de 220 VCA P2: Fase (L) de 220 VCA P3: Entrada de 4-20 mA – P4: Entrada de 4-20 mA + P5: Salida de 4-20 mA – P6: Salida de 4-20 mA + […]

Manual de usuario del DC-FB3

El módulo DC-FB3, una vez instalado en el actuador eléctrico DCL, permite controlar la posición de la válvula mediante Modbus-TCP/IP. La instalación se muestra a continuación: 1. Control del actuador eléctrico DCL mediante Modbus-TCP/IP con parámetros predeterminados. El DC-FB3 viene preconfigurado en modo cliente. Utilizando los parámetros predeterminados de MAC, IP, puerta de enlace, servidor y puerto, puede controlar el […]

Manual de usuario del DC-FB1

El DC-FB1 es un convertidor de USB a RS485 que permite la comunicación entre un ordenador y un dispositivo mediante el protocolo RS485. Este manual proporciona los pasos necesarios para poner en marcha el DC-FB1 y permitir la comunicación con dispositivos RS485 desde su ordenador. A continuación, se explica cómo configurarlo: Conexión del DC-FB1 al ordenador 1. Enchufe […]

JB/T 8219—2016 Norma para actuadores eléctricos ordinarios e inteligentes utilizados en sistemas de control de procesos industriales.

Table of Contents Preface 1 Scope 2 Normative References 3 Terms and Definitions 4 Product Classification and Basic Parameters 4.1 Product Classification 4.2 Basic Parameters 5 Basic Functions of Intelligent Actuators 5.1 Display Function 5.2 Parameter Setting Function 5.3 On-Site Configuration Function 5.4 Fault Self-Diagnosis and Alarm Function 5.5 Communication Function 5.6 Other Functions 6 […]

GB/T 3369.1—2008/IEC 60381-1:1982

The standard for the 4-20mA current signal used in electric actuators is as follows: Standard: GB/T 3369.1—2008/IEC 60381-1:1982 Title: Analogue signals for process control systems — Part 1: Direct current signals (IEC 60381-1:1982, IDT) This standard defines the specifications for analog signals, specifically for the use of direct current (DC) signals in process control systems, […]

Solicitud de cotización

Pulse "Enviar" ahora; más adelante le confirmaremos el número de modelo del producto y el distribuidor local, y luego le enviaremos el presupuesto.

WhatsApp

Escanea el código QR para chatear con nuestro ingeniero ahora...

Solicitud de cotización

Pulse "Enviar" ahora; más adelante le confirmaremos el número de modelo del producto y el distribuidor local, y luego le enviaremos el presupuesto.

WhatsApp

Escanea el código QR para chatear con nuestro ingeniero ahora...

Solicitud de cotización

Pulse "Enviar" ahora; más adelante le confirmaremos el número de modelo del producto y el distribuidor local, y luego le enviaremos el presupuesto.

WhatsApp

Escanea el código QR para chatear con nuestro ingeniero ahora...

🤝 Construyamos tu marca juntos

✅ ODM

  • Su logotipo y embalaje
  • Formatos de salida personalizados (4-20 mA, RS485 Modbus, HART, etc.)
  • Cambios en el color o la etiqueta de la carcasa
  • Versiones preparadas para la nube (opcional)

✅ OEM

  • Siga estrictamente su diseño y especificaciones.
  • Confidencialidad absoluta y protección de la propiedad intelectual.
  • Producción de alta calidad a un precio competitivo.
  • Producción en lotes pequeños o a gran escala
  • 🏭 Investigación y desarrollo y fabricación internasDesde la placa de circuito impreso hasta la carcasa, todo bajo un mismo techo.
  • 💬 Soporte multilingüeIngenieros y personal de ventas que hablen inglés.

  • ⚙️ Cantidad mínima de pedido flexible: Apoyo tanto para empresas emergentes como para marcas globales.

  • 🚀 Prototipado rápidoEntrega de muestras en 7-10 días.

 Contáctanos hoy Para solicitar un catálogo de productos o una consulta gratuita.

Solicitud de cotización

Enviar consulta

WhatsApp

Escanea el código QR para chatear con nuestro ingeniero ahora...

Contáctanos

Teléfono

(+86) 130 2633 1611

WhatsApp

Ken Bryan

即时客服图标 | Icono de mensaje en vivo

Chat en el sitio

Haz clic en el icono de la esquina inferior derecha para chatear con nosotros...