Compare parameters between DCL explosion-proof actuators
Model | Ángulo de giro | Par/Tiempo de funcionamiento | Duty Type | Tensión de alimentación | Señal de entrada/salida | Additional Option |
---|---|---|---|---|---|---|
DCL-Ex05 | 0 - 360 ° | 50Nm/20S Opcional con 20Nm/4S 30Nm/10S 50Nm/60S | ON - OFF Modulación Inching - Posicionamiento | DC24V AC24V AC110V AC220V AC380V | 4-20 mA 0-10V Interfaz IO Optional with field bus Modbus-RTU Modbus-ASCII CAN Ethernet | Over torque protection Fail Safe Return Deshumidificación Autobús de campo |
DCL-Ex10 | 0 - 90 ° | 100Nm/30S Opcional con 50Nm/15S 100Nm/60S | ON - OFF Modulación Inching - Posicionamiento | DC24V AC24V AC110V AC220V AC380V | 4-20 mA 0-10V Interfaz IO Optional with field bus Modbus-RTU Modbus-ASCII CAN Ethernet | Over torque protection Fail Safe Return Deshumidificación Autobús de campo |
DCL-Ex20 | 0 - 90 ° | 200Nm/30S Opcional con 100Nm/15S 200Nm/60S | ON - OFF Modulación Inching - Posicionamiento | DC24V AC110V AC220V AC380V | 4-20 mA 0-10V Interfaz IO Optional with field bus Modbus-RTU Modbus-ASCII CAN Ethernet | Over torque protection Fail Safe Return Deshumidificación Autobús de campo |
DCL-Ex40 | 0 - 90 ° | 400Nm/30S Opcional con 200Nm/15S 400Nm/60S | ON - OFF Modulación Inching - Posicionamiento | DC24V AC110V AC220V AC380V | 4-20 mA 0-10V Interfaz IO Optional with field bus Modbus-RTU Modbus-ASCII CAN Ethernet | Over torque protection Fail Safe Return Deshumidificación Autobús de campo |
DCL-Ex60 | 0 - 90 ° | 600Nm/45S | ON - OFF Modulación Inching - Posicionamiento | DC24V AC110V AC220V AC380V | 4-20 mA 0-10V Interfaz IO Optional with field bus Modbus-RTU Modbus-ASCII CAN Ethernet | Over torque protection Fail Safe Return Deshumidificación Autobús de campo |
Recommend actuator to drive a butterfly valve
Recommend actuator to drive a Ball valve
Recommend actuator to drive a ventilation valve
Recommend valve to be driven by DCL explosion-proof actuator
Note: The recommendations in the above table is for reference only in common application scenario, the specific torque needed to drive the valve is depended up on the real application case.
It is recommended to choose an actuator with 1.1-1.3 times of torque than the value that was finalized after evaluation of torque requirement of valve and liquid pressure in the pipe. This would improve the robust performance in most worst case.
View actuators with different torque
50Nm/20S
————————–
Opcional con
20Nm/4S
30Nm/10S
50Nm/60S
100Nm/30S
————————–
Opcional con
50Nm/15S
100Nm/60S
200Nm/30S
————————–
Opcional con
100Nm/15S
200Nm/60S
400Nm/30S
————————–
Opcional con
200Nm/15S
400Nm/60S