{"id":10800,"date":"2025-03-20T01:13:47","date_gmt":"2025-03-20T01:13:47","guid":{"rendered":"https:\/\/dclcontrols.com\/?p=10800"},"modified":"2025-03-23T06:24:09","modified_gmt":"2025-03-23T06:24:09","slug":"how-to-control-dcl-actuator-through-modbus-by-vatesttool_dcl-exe","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/en\/support\/how-to-actuator\/how-to-control-dcl-actuator-through-modbus-by-vatesttool_dcl-exe","title":{"rendered":"How to control DCL actuator through modbus by vaTestTool_DCL.exe"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"10800\" class=\"elementor elementor-10800\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b21a808 e-flex e-con-boxed e-con e-parent\" data-id=\"b21a808\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-829e2a8 elementor-widget elementor-widget-heading\" data-id=\"829e2a8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">1.Open vaTestTool_DCL-v1.31.exe.<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-85a2dc1 elementor-widget elementor-widget-heading\" data-id=\"85a2dc1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">2.The application will popup a \u201cConnect to\u201d dialog to set the target device id and local computer RS232 port parameters as follow.<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-64124c3 elementor-widget elementor-widget-image\" data-id=\"64124c3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/dclcontrols.com\/dam\/support\/an\/images\/connect-to-dialog.webp\" title=\"\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6fc4b4f elementor-widget elementor-widget-text-editor\" data-id=\"6fc4b4f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><i><\/i><em><i>Choose the COM port which connected to the USB-RS485 connector.<\/i><\/em><\/li><li><i><\/i><em><i>Select the modbus baud rate (the default baudrate on DCL actuator now is 9600).<\/i><\/em><\/li><li><i><\/i><em><i>Click on <\/i><\/em><em><i>\u201c<\/i><\/em><em><i>CONNECT<\/i><\/em><em><i>\u201d<\/i><\/em><em><i>button to connect to the actuator.<\/i><\/em><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ae7bcf0 elementor-widget elementor-widget-image\" data-id=\"ae7bcf0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/dclcontrols.com\/dam\/support\/an\/images\/connected-to-dcl-acutator.webp\" title=\"\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bfbf3a6 elementor-widget elementor-widget-heading\" data-id=\"bfbf3a6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">3.Close the \u201cConnect to\u201d windows and now you are in operation windows.<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-92829e4 elementor-widget elementor-widget-image\" data-id=\"92829e4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/dclcontrols.com\/dam\/support\/an\/images\/operation-windwos2.webp\" title=\"\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b62bdce elementor-widget elementor-widget-text-editor\" data-id=\"b62bdce\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><i><\/i><em><i>Now you can click on <\/i><\/em><em><i>\u201c<\/i><\/em><em><i>OPEN\/CLOSE\/STOP<\/i><\/em><em><i>\u201d<\/i><\/em><em><i>button to control the actuator.<\/i><\/em><\/li><li><i><\/i><em><i>Your can input in <\/i><\/em><em><i>\u201c<\/i><\/em><em><i>Set position<\/i><\/em><em><i>\u201d<\/i><\/em><em><i>text frame and then click on <\/i><\/em><em><i>\u201c<\/i><\/em><em><i>SET POS<\/i><\/em><em><i>\u201d<\/i><\/em><em><i>\u00a0button to let actuator drive the valve to the position as you wish.<\/i><\/em><\/li><li><i><\/i><em><i>You can click on <\/i><\/em><em><i>\u201c<\/i><\/em><em><i>4-20mA INPUT<\/i><\/em><em><i>\u201d<\/i><\/em><em><i>to let the actuator to switch to 4-20mA mode in witch the actuator will ignore the modbus command and make the 4-20mA as position input.<\/i><\/em><\/li><li><i><\/i><em><i>You can click on <\/i><\/em><em><i>\u201c<\/i><\/em><em><i>MONITOR<\/i><\/em><em><i>\u201d<\/i><\/em><em><i>button to enable or disable monitoring the real actuator positions.<\/i><\/em><\/li><li><i><\/i><em><i>The 4 indicators on the top right can show the status of 4-20mA input, modbus, actuator availability.<\/i><\/em><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ac373a0 elementor-widget elementor-widget-heading\" data-id=\"ac373a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">4.To change the modbus baud rate and ID of actuator, click on the gear icon on the top left then a \u201cconfig\u201d dialog popup.<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9b28356 elementor-widget elementor-widget-image\" data-id=\"9b28356\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/dclcontrols.com\/dam\/support\/an\/images\/change-modbus-para.webp\" title=\"\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e503bf9 elementor-widget elementor-widget-text-editor\" data-id=\"e503bf9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><i><\/i><em><i>Set the value in <\/i><\/em><em><i>\u201c<\/i><\/em><em><i>Device ID<\/i><\/em><em><i>\u201d<\/i><\/em><em><i>and <\/i><\/em><em><i>\u201c<\/i><\/em><em><i>Baudrate<\/i><\/em><em><i>\u201d<\/i><\/em><em><i>\u00a0in target device group as the current configuration in the actuator.<\/i><\/em><\/li><li><i><\/i><em><i>Input the new parameters as you wish in <\/i><\/em><em><i>\u201c<\/i><\/em><em><i>Set new modbus parameter<\/i><\/em><em><i>\u201d<\/i><\/em><i><\/i><\/li><li><i><\/i><em><i>Click on <\/i><\/em><em><i>\u201c<\/i><\/em><em><i>SET ID<\/i><\/em><em><i>\u201d<\/i><\/em><em><i>to change the ID without changing baud rate.<\/i><\/em><\/li><li><i><\/i><em><i>Click on <\/i><\/em><em><i>\u201c<\/i><\/em><em><i>SET BAUDRATE<\/i><\/em><em><i>\u201d<\/i><\/em><em><i>to change the baud rate without changing ID.<\/i><\/em><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bd88d57 elementor-widget elementor-widget-image\" data-id=\"bd88d57\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/dclcontrols.com\/dam\/support\/an\/images\/change-modbus-para-done.webp\" title=\"\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>1.Open vaTestTool_DCL-v1.31.exe. 2.The application will popup a \u201cConnect to\u201d dialog to set the target device id and local computer RS232 port parameters as follow. Choose the COM port which connected to the USB-RS485 connector. Select the modbus baud rate (the default baudrate on DCL actuator now is 9600). Click on \u201cCONNECT\u201dbutton to connect to the [&hellip;]<\/p>","protected":false},"author":1,"featured_media":10942,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[100],"tags":[53],"class_list":["post-10800","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-how-to-actuator","tag-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/en\/wp-json\/wp\/v2\/posts\/10800","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/en\/wp-json\/wp\/v2\/comments?post=10800"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/en\/wp-json\/wp\/v2\/posts\/10800\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/en\/wp-json\/wp\/v2\/media\/10942"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/en\/wp-json\/wp\/v2\/media?parent=10800"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/en\/wp-json\/wp\/v2\/categories?post=10800"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/en\/wp-json\/wp\/v2\/tags?post=10800"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}