{"id":6033,"date":"2023-08-03T20:44:54","date_gmt":"2023-08-03T12:44:54","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6033"},"modified":"2025-03-27T09:47:56","modified_gmt":"2025-03-27T09:47:56","slug":"dcl-02-on-off-actuator","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/de_ch\/unterstutzung\/herr-aktuator\/dcl-02-ein-aus-stellglied","title":{"rendered":"H\u00e4ufige Fehler und Fehlerbehebung bei DCL-02 EIN-AUS-Stellantrieben"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6033\" class=\"elementor elementor-6033\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-23bbd22 e-con-full e-flex e-con e-parent\" data-id=\"23bbd22\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-add184b e-con-full e-flex e-con e-child\" data-id=\"add184b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ec8fa0c elementor-widget elementor-widget-text-editor\" data-id=\"ec8fa0c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"0\" data-end=\"92\">Diese Anleitung gilt f\u00fcr die Aktuatoren der DCL Ultra-Small Serie, und zwar f\u00fcr die folgenden Modelle:<\/p><ul data-start=\"94\" data-end=\"123\"><li class=\"\" data-start=\"94\" data-end=\"103\"><p class=\"\" data-start=\"96\" data-end=\"103\">DCL-02A<\/p><\/li><li class=\"\" data-start=\"104\" data-end=\"113\"><p class=\"\" data-start=\"106\" data-end=\"113\">DCL-02B<\/p><\/li><li class=\"\" data-start=\"114\" data-end=\"123\"><p class=\"\" data-start=\"116\" data-end=\"123\">DCL-02G<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-69c14e5 elementor-widget elementor-widget-image\" data-id=\"69c14e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"176\" height=\"399\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-02-valve.webp\" class=\"attachment-full size-full wp-image-4861\" alt=\"\u534e\u6613\u7cbe\u5de7\u7cfb\u5217\u6267\u884c\u5668 DCL-02 \u914d\u9600 | Stellventil DCL-02\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b43d346 elementor-widget elementor-widget-heading\" data-id=\"b43d346\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">H\u00e4ufige Fehler und Methoden zur Fehlerbehebung<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e1d44fb elementor-widget elementor-widget-text-editor\" data-id=\"e1d44fb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0<\/p><table><thead><tr><th><strong>Fehler<\/strong><\/th><th><strong>M\u00f6gliche Ursachen<\/strong><\/th><th><strong>Methoden zur Fehlerbehebung<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>Der Aktor \u00f6ffnet oder schlie\u00dft beim ersten Start nicht.<\/strong><\/td><td>1. Falsche Verkabelung<\/td><td>\u00dcberpr\u00fcfen Sie die Verkabelung anhand des Schaltplans des Aktuators.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Falsche Stromversorgung<\/td><td>Stellen Sie sicher, dass die Versorgungsspannung innerhalb von \u00b110% der Nennspannung des Aktuators liegt und der Strom das Dreifache des Nennstroms betr\u00e4gt.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Defekter Steuerschalter oder Relais<\/td><td>Messen Sie die Eingangsspannung am Steueranschluss des Aktuators mit einem Multimeter, um zu \u00fcberpr\u00fcfen, ob sie den Erwartungen entspricht.<\/td><\/tr><tr><td>\u00a0<\/td><td>4. Fehlanpassung des Steuerungssystems<\/td><td>Testen Sie den Aktor mit einem mechanischen Schalter. Funktioniert er normal, \u00fcberpr\u00fcfen Sie die Ausgangslogik des Steuerungssystems.<\/td><\/tr><tr><td>\u00a0<\/td><td>5. Mehrere Aktuatoren oder Aktuatoren und andere Ger\u00e4te, die parallel geschaltet sind<\/td><td>Die Schaltaktoren sollten mit einer Einwegsteuerung arbeiten und nicht parallel geschaltet werden, da dies den Anlaufkondensator beeintr\u00e4chtigt.<\/td><\/tr><tr><td><strong>Der Aktor kann nur \u00f6ffnen oder schlie\u00dfen<\/strong><\/td><td>1. Falsche Verkabelung<\/td><td>\u00dcberpr\u00fcfen Sie die Verkabelung anhand des Schaltplans des Aktuators.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Falsche Einstellung der Nockenwelle f\u00fcr vollst\u00e4ndiges \u00d6ffnen\/Schlie\u00dfen.<\/td><td>Beachten Sie die Anleitung \u201eEinstellen von elektrischen Schaltventilen\u201c und stellen Sie die Nockenpositionen korrekt ein.<\/td><\/tr><tr><td><strong>Der Aktor stoppt mitten in der Bewegung.<\/strong><\/td><td>1. Ventil blockiert<\/td><td>Pr\u00fcfen Sie das Ventil auf Verstopfungen. Beseitigen Sie jegliche Blockaden und versuchen Sie es erneut, nachdem der \u00dcberlastschutz des Stellantriebs abgek\u00fchlt ist.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Feststoffe in der Fl\u00fcssigkeit verursachen Ventilblockade<\/td><td>Pr\u00fcfen Sie die Fl\u00fcssigkeit auf Feststoffpartikel, die Ventilblockaden verursachen. Beseitigen Sie die Blockade und versuchen Sie es erneut, nachdem der \u00dcberlastschutz des Stellantriebs abgek\u00fchlt ist.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Falsche Einstellung des Anschlags f\u00fcr vollst\u00e4ndiges \u00d6ffnen\/Schlie\u00dfen<\/td><td>Beachten Sie die Hinweise in der Anleitung \u201eEinstellen von elektrischen Schaltventilen\u201c und stellen Sie die Anschlagpositionen korrekt ein.<\/td><\/tr><tr><td><strong>Der Aktuator l\u00e4sst sich mit dem Griff nicht drehen.<\/strong><\/td><td>1. Feststoffe in der Fl\u00fcssigkeit verursachen ein Festfressen des Ventils<\/td><td>Pr\u00fcfen Sie das Ventil auf Verstopfungen. Beseitigen Sie die Verstopfung und versuchen Sie es erneut, nachdem der \u00dcberlastschutz des Stellantriebs abgek\u00fchlt ist.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Ventilblockierung<\/td><td>Pr\u00fcfen Sie das Ventil auf Blockierung. Beseitigen Sie die Blockierung und versuchen Sie es erneut, nachdem der \u00dcberlastschutz des Stellantriebs abgek\u00fchlt ist.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. Besch\u00e4digter Aktuator-Untersetzungsmechanismus<\/td><td>Entfernen Sie den Stellantrieb vom Ventil und drehen Sie den Griff. Wenn er sich nicht bewegt, ersetzen Sie den Stellantrieb.<\/td><\/tr><tr><td><strong>Kein Positionsr\u00fcckmeldesignal<\/strong><\/td><td>1. Falsche Verdrahtung am Schalter<\/td><td>\u00dcberpr\u00fcfen Sie die Verkabelung anhand des Schaltplans des Aktuators.<\/td><\/tr><tr><td>\u00a0<\/td><td>2. Falsche Einstellung der Nockenwelle f\u00fcr vollst\u00e4ndiges \u00d6ffnen\/Schlie\u00dfen.<\/td><td>Beachten Sie die Anleitung \u201eEinstellen von elektrischen Schaltventilen\u201c und stellen Sie die Nockenposition korrekt ein.<\/td><\/tr><tr><td>\u00a0<\/td><td>3. \u00dcberstrom, der den Positionsr\u00fcckmeldeschalter besch\u00e4digt.<\/td><td>1. Pr\u00fcfen Sie, ob der Nocken f\u00fcr vollst\u00e4ndiges \u00d6ffnen\/Schlie\u00dfen gem\u00e4\u00df der Anleitung korrekt auf den Positionsr\u00fcckmeldeschalter dr\u00fcckt.<\/td><\/tr><tr><td>\u00a0<\/td><td>\u00a0<\/td><td>2. Pr\u00fcfen Sie, ob der Positionsr\u00fcckkopplungskreis geschlossen ist.<\/td><\/tr><\/tbody><\/table><p>\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d58177d elementor-widget elementor-widget-heading\" data-id=\"d58177d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pr\u00fcfen Sie, ob die Betriebsbedingungen den Parameteranforderungen entsprechen.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60cdda7 elementor-widget elementor-widget-text-editor\" data-id=\"60cdda7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"156\" data-end=\"422\">Elektrische Stellantriebe k\u00f6nnen aufgrund unsachgem\u00e4\u00dfer Verwendung oder Betrieb unter falschen Betriebsbedingungen ausfallen. Bei Einhaltung der in den Produktspezifikationen definierten Betriebsbedingungen ist ein zuverl\u00e4ssiger Betrieb des Stellantriebs \u00fcber einen l\u00e4ngeren Zeitraum ohne Ausfall zu erwarten.<\/p><ul data-start=\"424\" data-end=\"1721\"><li class=\"\" data-start=\"424\" data-end=\"610\"><p class=\"\" data-start=\"426\" data-end=\"610\"><strong data-start=\"426\" data-end=\"445\">Versorgungsspannung:<\/strong> Die Spannung des Netzteils muss innerhalb des Nennbetriebsspannungsbereichs des Aktuators liegen. \u00dcber- oder Unterspannung kann die Lebensdauer des Aktuators verk\u00fcrzen.<\/p><\/li><li class=\"\" data-start=\"614\" data-end=\"840\"><p class=\"\" data-start=\"616\" data-end=\"840\"><strong data-start=\"616\" data-end=\"635\">Versorgungsstrom:<\/strong> Der Anlaufstrom des Motors ist deutlich h\u00f6her als der Nennstrom. Um einen zuverl\u00e4ssigen Betrieb zu gew\u00e4hrleisten, verwenden Sie ein Netzteil, das mindestens das Dreifache des Nennstroms des Aktuators liefern kann.<\/p><\/li><li class=\"\" data-start=\"842\" data-end=\"1035\"><p class=\"\" data-start=\"844\" data-end=\"1035\"><strong data-start=\"844\" data-end=\"860\">Temperatur:<\/strong> Stellen Sie sicher, dass der Stellantrieb innerhalb seines Nenntemperaturbereichs arbeitet. Der Betrieb des Stellantriebs au\u00dferhalb dieses Bereichs kann zu Leistungseinbu\u00dfen, verk\u00fcrzter Lebensdauer und schlie\u00dflich zum Ausfall f\u00fchren.<\/p><\/li><li class=\"\" data-start=\"1037\" data-end=\"1504\"><p class=\"\" data-start=\"1039\" data-end=\"1504\"><strong data-start=\"1039\" data-end=\"1055\">Umfeld:<\/strong> Der DCL-Schaltaktuator ist gem\u00e4\u00df Schutzart IP67 wetterfest und eignet sich daher f\u00fcr Innen- und Au\u00dfenanwendungen. Er bietet Schutz vor Regen und Spritzwasser und tr\u00e4gt so zur Verl\u00e4ngerung der Lebensdauer des Aktuators bei, indem er ihn vor Regen, Schnee, Eis und UV-Strahlung (Sonnenlicht) sch\u00fctzt. In stark korrosiven Umgebungen k\u00f6nnen elektronische Bauteile jedoch vorzeitig ausfallen. Nicht explosionsgesch\u00fctzte Aktuatoren d\u00fcrfen nicht in explosionsgef\u00e4hrdeten Bereichen eingesetzt werden.<\/p><\/li><li class=\"\" data-start=\"1506\" data-end=\"1721\"><p class=\"\" data-start=\"1508\" data-end=\"1721\"><strong data-start=\"1508\" data-end=\"1523\">Arbeitszyklus:<\/strong> Der DCL-Schaltantrieb hat ein Tastverh\u00e4ltnis von 70% (42 Sekunden Betrieb pro Minute, gefolgt von 18 Sekunden Pause). Wird dieses Tastverh\u00e4ltnis \u00fcberschritten, kann der Motor in den \u00dcberhitzungsschutz wechseln.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0273976 elementor-widget elementor-widget-heading\" data-id=\"0273976\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00dcberpr\u00fcfen Sie die Verkabelung des Aktuators.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9df2216 elementor-widget elementor-widget-text-editor\" data-id=\"9df2216\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"45\" data-end=\"186\">Stellen Sie sicher, dass der Aktor gem\u00e4\u00df dem vom Hersteller bereitgestellten Schaltplan korrekt verkabelt ist. Gehen Sie zur \u00dcberpr\u00fcfung der Verkabelung wie folgt vor:<\/p><ol data-start=\"188\" data-end=\"1007\"><li class=\"\" data-start=\"188\" data-end=\"325\"><p class=\"\" data-start=\"191\" data-end=\"209\"><strong data-start=\"191\" data-end=\"208\">Stromversorgung:<\/strong><\/p><ul data-start=\"213\" data-end=\"325\"><li class=\"\" data-start=\"213\" data-end=\"321\"><p class=\"\" data-start=\"215\" data-end=\"321\">Pr\u00fcfen Sie die Stromversorgungsanschl\u00fcsse, um sicherzustellen, dass sie mit der erforderlichen Eingangsspannung und dem Eingangsstrom des Aktuators \u00fcbereinstimmen.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"326\" data-end=\"504\"><p class=\"\" data-start=\"329\" data-end=\"353\"><strong data-start=\"329\" data-end=\"353\">Steuerverbindungen:<\/strong><\/p><ul data-start=\"357\" data-end=\"504\"><li class=\"\" data-start=\"357\" data-end=\"504\"><p class=\"\" data-start=\"359\" data-end=\"504\">Pr\u00fcfen Sie, ob die Eingangs- und Ausgangssteueranschl\u00fcsse fest verbunden und gem\u00e4\u00df dem Verdrahtungsplan des Aktuators korrekt konfiguriert sind.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"506\" data-end=\"707\"><p class=\"\" data-start=\"509\" data-end=\"527\"><strong data-start=\"509\" data-end=\"527\">Signalverdrahtung:<\/strong><\/p><ul data-start=\"531\" data-end=\"707\"><li class=\"\" data-start=\"531\" data-end=\"639\"><p class=\"\" data-start=\"533\" data-end=\"639\">Pr\u00fcfen Sie die Verkabelung auf Steuersignale, z. B. 4-20 mA oder 0-10 V, je nach den Spezifikationen des Aktuators.<\/p><\/li><li class=\"\" data-start=\"643\" data-end=\"707\"><p class=\"\" data-start=\"645\" data-end=\"707\">Pr\u00fcfen Sie, ob keine losen Verbindungen oder Kurzschl\u00fcsse vorliegen.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"709\" data-end=\"823\"><p class=\"\" data-start=\"712\" data-end=\"726\"><strong data-start=\"712\" data-end=\"726\">Erdung:<\/strong><\/p><ul data-start=\"730\" data-end=\"823\"><li class=\"\" data-start=\"730\" data-end=\"823\"><p class=\"\" data-start=\"732\" data-end=\"823\">Stellen Sie sicher, dass der Aktor ordnungsgem\u00e4\u00df geerdet ist, um elektrische St\u00f6rungen oder Besch\u00e4digungen zu vermeiden.<\/p><\/li><\/ul><\/li><li class=\"\" data-start=\"825\" data-end=\"1007\"><p class=\"\" data-start=\"828\" data-end=\"863\"><strong data-start=\"828\" data-end=\"863\">Anschl\u00fcsse an andere Ger\u00e4te:<\/strong><\/p><ul data-start=\"867\" data-end=\"1007\"><li class=\"\" data-start=\"867\" data-end=\"1007\"><p class=\"\" data-start=\"869\" data-end=\"1007\">Wenn der Aktor mit anderen Ger\u00e4ten verbunden ist, stellen Sie sicher, dass diese Verbindungen ebenfalls korrekt sind und keine St\u00f6rungen oder Stromversorgungsprobleme verursachen.<\/p><\/li><\/ul><\/li><\/ol><p class=\"\" data-start=\"1009\" data-end=\"1155\">Wenn die Verkabelung korrekt erscheint, der Aktor aber dennoch nicht funktioniert, sind m\u00f6glicherweise weitere Fehlersuche oder die Unterst\u00fctzung eines Technikers erforderlich.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-84857ae e-flex e-con-boxed e-con e-parent\" data-id=\"84857ae\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cf23cb0 elementor-widget elementor-widget-template\" data-id=\"cf23cb0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"template.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-template\">\n\t\t\t\t\t<div data-elementor-type=\"section\" data-elementor-id=\"10969\" class=\"elementor elementor-10969\" data-elementor-post-type=\"elementor_library\">\n\t\t\t<div class=\"elementor-element elementor-element-d642a8e e-flex e-con-boxed e-con e-parent\" data-id=\"d642a8e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-4dcc388 e-con-full e-flex e-con e-child\" data-id=\"4dcc388\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-09f4232 elementor-widget elementor-widget-heading\" data-id=\"09f4232\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">A - Mit 2 aktiven Endpositionssignalausg\u00e4ngen<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-daf3293 elementor-widget elementor-widget-image\" data-id=\"daf3293\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"341\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-a.webp\" class=\"attachment-full size-full wp-image-4860\" alt=\"DCL ist ein DCL-Ger\u00e4t\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-14e5438 elementor-widget elementor-widget-text-editor\" data-id=\"14e5438\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Steueraktuator zum \u00d6ffnen oder Schlie\u00dfen mit K<\/li><li>Der Ausgangsanschluss der Endposition OPEN\/CLOSE sendet das Ereignis als aktives 220VAC-Signal aus, sobald die Endposition erreicht ist.<\/li><\/ul><p>\u00a0<\/p><p><strong>Verbindungsdetails:<\/strong><\/p><ol><li>Anschluss des Neutralleiters der Wechselstromversorgung AC85-220V an P1.<\/li><li>Schalten Sie die AC85-220V-Leitung auf GESCHLOSSEN (P2), um das Ventil zu schlie\u00dfen.<\/li><li>Schalten Sie die AC85-220V-Leitung auf OPEN(P3), um das Ventil zu \u00f6ffnen.<\/li><li>P5 ist der Endpositionsanschluss OPEN, der eine AC220V-Quelle ausgibt, mit der eine Kontrollleuchte angesteuert werden kann, wenn der Aktor die Endposition offen erreicht hat.<\/li><li>P6 ist der Endpositions-OPEN-Anschluss, der eine AC220V-Quelle ausgibt, mit der eine Kontrollleuchte angesteuert werden kann, wenn der Aktor die Endposition geschlossen erreicht hat.<\/li><li>Schlie\u00dfen Sie die Erde an P7 an.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f1a67a7 e-con-full e-flex e-con e-child\" data-id=\"f1a67a7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a942089 elementor-widget elementor-widget-heading\" data-id=\"a942089\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">B - Mit 2 passiven Endpositionsschaltern<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-766f845 elementor-widget elementor-widget-image\" data-id=\"766f845\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"348\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-b.webp\" class=\"attachment-full size-full wp-image-4858\" alt=\"DCL ist eine B-Version\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-799d994 elementor-widget elementor-widget-text-editor\" data-id=\"799d994\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Steueraktuator zum \u00d6ffnen oder Schlie\u00dfen mit K<\/li><li>Der Ausgangsanschluss der Endposition OPEN\/CLOSE sendet das Ereignis als passives Signal aus, sobald die Endposition erreicht ist.<\/li><\/ul><p>\u00a0<\/p><p><strong>Verbindungsdetails:<\/strong><\/p><ol><li>Anschluss des Neutralleiters der Wechselstromversorgung AC85-220V an P1.<\/li><li>Schalten Sie die AC85-220V-Leitung auf GESCHLOSSEN (P2), um das Ventil zu schlie\u00dfen.<\/li><li>Schalten Sie die AC85-220V-Leitung auf OPEN(P3), um das Ventil zu \u00f6ffnen.<\/li><li>P4 ist der COM-Anschluss f\u00fcr das passive Kontaktsignal der Endposition OPEN\/CLOSE, das normalerweise mit dem Signal GND verbunden ist.<\/li><li>P5 ist der Endpositionsanschluss OPEN, der mit COM verbunden wird, wenn der Aktor die Endposition offen erreicht hat.<\/li><li>P6 ist der Endpositionsanschluss CLOSE, der mit COM verbunden wird, wenn der Aktor die Endposition CLOSE erreicht hat.<\/li><li>Schlie\u00dfen Sie die Erde an P7 an.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-738bf4f e-con-full e-flex e-con e-child\" data-id=\"738bf4f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5a73aaa elementor-widget elementor-widget-heading\" data-id=\"5a73aaa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">G - Gleichstrommotor mit 2 Endschaltern<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8c393f4 elementor-widget elementor-widget-image\" data-id=\"8c393f4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"391\" src=\"https:\/\/dclcontrols.com\/wp-content\/uploads\/2023\/05\/dcl-actuator-interface-diagram-g.webp\" class=\"attachment-full size-full wp-image-4853\" alt=\"DCL ist eine G-Version\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a35d4cf elementor-widget elementor-widget-text-editor\" data-id=\"a35d4cf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Der Stellantrieb wird durch die Richtung der Versorgungsspannung zwischen den Klemmen 1 und 2 zum \u00d6ffnen oder Schlie\u00dfen gesteuert.<\/li><li>Der Ausgangsanschluss der Endposition OPEN\/CLOSE sendet das Ereignis als passives Signal aus, sobald die Endposition erreicht ist.<\/li><\/ul><p>\u00a0<\/p><p><strong>Verbindungsdetails:<\/strong><\/p><ol><li>Durch Anschlie\u00dfen von DC24V+ an P1 und DC24V- an P2 wird das Ventil geschlossen.<\/li><li>Durch Anschlie\u00dfen von DC24V+ an P2 und DC24V- an P1 wird das Ventil geschlossen.<\/li><li>P3 ist der COM-Anschluss f\u00fcr das passive Kontaktsignal der Endposition OPEN\/CLOSE, das normalerweise mit dem Signal GND verbunden ist.<\/li><li>P4 ist der Endpositionsanschluss OPEN, der mit COM verbunden wird, wenn der Aktor die Endposition offen erreicht hat.<\/li><li>P5 ist der Endpositionsanschluss CLOSE, der mit COM verbunden wird, wenn der Aktor die Endposition CLOSE erreicht hat.<\/li><li>Schlie\u00dfen Sie die Erde an P7 an.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ff65758 e-con-full e-flex e-con e-parent\" data-id=\"ff65758\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-d5dc048 e-con-full e-flex e-con e-child\" data-id=\"d5dc048\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-527200f elementor-widget elementor-widget-text-editor\" data-id=\"527200f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Notiz:<\/p><ul><li>Der Schaltkreis im gestrichelten Kasten ist der interne Schaltkreis des Aktuators. Der Schaltkreis au\u00dferhalb des Kastens veranschaulicht die elektrische Verbindung zum Betrieb des Aktuators.<\/li><li>Falls Sie weitere spezielle Anforderungen an die Anschlussschaltung haben, wenden Sie sich bitte an unseren technischen Support.\u00a0<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-002d845 elementor-widget elementor-widget-text-editor\" data-id=\"002d845\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wenn Sie vor Ort eine Fehlersuche durchf\u00fchren, k\u00f6nnen Sie sich jederzeit umgehend an unsere technischen Servicemitarbeiter wenden, um Unterst\u00fctzung bei der Diagnose und Behebung des Problems zu erhalten. <br \/>Kontakttelefonnummer: 13026331611 (Herr Chen)<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Diese Anleitung gilt f\u00fcr die Stellantriebe der DCL Ultra-Small Serie, Modelle: DCL-02A, DCL-02B, DCL-02G. H\u00e4ufige Fehler und deren Behebung: Fehler: Stellantrieb \u00f6ffnet oder schlie\u00dft beim Start nicht. M\u00f6gliche Ursachen: 1. Falsche Verkabelung: \u00dcberpr\u00fcfen Sie die Verkabelung anhand des Schaltplans des Stellantriebs. 2. Falsche Stromversorgung: Stellen Sie sicher, dass [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[103],"tags":[53],"class_list":["post-6033","post","type-post","status-publish","format-standard","hentry","category-mr-actuator","tag-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/de_ch\/wp-json\/wp\/v2\/posts\/6033","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/de_ch\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/de_ch\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/de_ch\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/de_ch\/wp-json\/wp\/v2\/comments?post=6033"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/de_ch\/wp-json\/wp\/v2\/posts\/6033\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/de_ch\/wp-json\/wp\/v2\/media?parent=6033"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/de_ch\/wp-json\/wp\/v2\/categories?post=6033"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/de_ch\/wp-json\/wp\/v2\/tags?post=6033"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}