{"id":6075,"date":"2023-08-10T11:24:32","date_gmt":"2023-08-10T03:24:32","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6075"},"modified":"2025-03-31T08:22:18","modified_gmt":"2025-03-31T08:22:18","slug":"how-24v-switch-actuator-works","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/da_dk\/stotte\/ta-acutator\/how-24v-switch-actuator-works","title":{"rendered":"S\u00e5dan fungerer DC24V ON-OFF-aktuatoren (elektrisk ventil)"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6075\" class=\"elementor elementor-6075\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-05aec29 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"05aec29\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4dc31e3\" data-id=\"4dc31e3\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-11f2047 elementor-widget elementor-widget-text-editor\" data-id=\"11f2047\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone\" src=\"\/wp-content\/uploads\/2023\/05\/dcl-actuator-product-line.webp\" width=\"680\" height=\"586\" \/><\/p><p>When you install a <strong>DCL 24V ON-OFF type electric control valve<\/strong> on a pipeline, you can control it using a relay, ON-OFF control, or PLC (DCS), enabling the opening or shutting off of fluid flow.<\/p><p>This guide explains how the <strong>DCL 24V ON-OFF type electric actuators<\/strong> function using relays, PLCs, or ON-OFF control for valve operation.<\/p><hr \/><h3><strong>Using Relay\/PLC\/DCS to Control DCL Actuators<\/strong><\/h3><p><img decoding=\"async\" class=\"alignnone\" src=\"\/wp-content\/uploads\/2023\/08\/dc24v-switch-actuator-first-step-with-relay.webp\" width=\"800\" height=\"299\" \/><\/p><ul><li><p>When the relay switches the <strong>power (+) line to the &#8220;ON&#8221; input terminal<\/strong> and the <strong>power (-) line to the &#8220;OFF&#8221; input terminal<\/strong>, the actuator <strong>drives the valve open<\/strong>. Once fully open, the actuator stops, and the <strong>electric valve remains open<\/strong>.<\/p><\/li><li><p>When the relay switches the <strong>power (+) line to the &#8220;OFF&#8221; input terminal<\/strong> and the <strong>power (-) line to the &#8220;ON&#8221; input terminal<\/strong>, the actuator <strong>drives the valve closed<\/strong>. Once fully closed, the actuator stops, and the <strong>electric valve remains closed<\/strong>.<\/p><\/li><li><p>If power is lost while the actuator is in operation, the actuator <strong>stops driving<\/strong>, and the <strong>electric valve stays in its current position<\/strong>.<\/p><\/li><li><p>If your actuator is equipped with a <strong>heater and dehumidifier<\/strong>, <strong>keep the power supply on<\/strong> after the actuator reaches the fully open or fully closed position.<\/p><\/li><\/ul><p><strong>Note:<\/strong> The circuit diagram provided illustrates the basic function of an ON-OFF type actuator (electric valve). In practical applications, <strong>fuses, current limiters, and other protective components should be added<\/strong>.<\/p><hr \/><h3><strong>Using Switches to Control DCL Actuators<\/strong><\/h3><p><img decoding=\"async\" class=\"alignnone size-medium\" src=\"\/wp-content\/uploads\/2023\/08\/dc24v-switch-actuator-first-step-with-switch.webp\" alt=\"dc24v-switch-actuator-first-step-with-switch\" width=\"844\" height=\"330\" \/><\/p><ul><li><p>When an <strong>ON-OFF control<\/strong> switches the <strong>power (+) line to the &#8220;ON&#8221; input terminal<\/strong> and the <strong>power (-) line to the &#8220;OFF&#8221; input terminal<\/strong>, the actuator <strong>drives the valve open<\/strong>. Once fully open, the actuator stops, and the <strong>electric valve remains open<\/strong>.<\/p><\/li><li><p>When an <strong>ON-OFF control<\/strong> switches the <strong>power (+) line to the &#8220;OFF&#8221; input terminal<\/strong> and the <strong>power (-) line to the &#8220;ON&#8221; input terminal<\/strong>, the actuator <strong>drives the valve closed<\/strong>. Once fully closed, the actuator stops, and the <strong>electric valve remains closed<\/strong>.<\/p><\/li><li><p>If power is lost while the actuator is in operation, the actuator <strong>stops driving<\/strong>, and the <strong>electric valve stays in its current position<\/strong>.<\/p><\/li><li><p>If your actuator is equipped with a <strong>heater and dehumidifier<\/strong>, <strong>keep the power supply on<\/strong> after the actuator reaches the fully open or fully closed position.<\/p><\/li><\/ul><p><strong>Note:<\/strong> The circuit diagram provided illustrates the basic function of an ON-OFF type actuator (electric valve). In practical applications, <strong>fuses, current limiters, and other protective components should be added<\/strong>.<\/p><hr \/><h3><strong>Electric Valve Status<\/strong><\/h3><ul><li><p><strong>Closed Position<\/strong><\/p><\/li><\/ul><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/wp-content\/uploads\/2023\/08\/vale-closed.webp\" width=\"422\" height=\"388\" \/><\/p><ul><li><p><strong>Fully Open Position<\/strong><\/p><\/li><\/ul><p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium\" src=\"\/wp-content\/uploads\/2023\/08\/vale-open.webp\" width=\"466\" height=\"388\" \/><\/p><p>\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>N\u00e5r du installerer en elektrisk DCL 24V ON-OFF-reguleringsventil p\u00e5 en r\u00f8rledning, kan du styre den ved hj\u00e6lp af et rel\u00e6, en ON-OFF-styring eller en PLC (DCS), der muligg\u00f8r \u00e5bning eller afbrydelse af v\u00e6skestr\u00f8mmen. Denne vejledning forklarer, hvordan de elektriske DCL 24V ON-OFF-aktuatorer fungerer ved hj\u00e6lp af rel\u00e6er, PLC&#039;er eller ON-OFF-styring til ventiler [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[8],"tags":[53,66,62,57,64,52,65],"class_list":["post-6075","post","type-post","status-publish","format-standard","hentry","category-ta-acutator","tag-actuator","tag-explosion-proof-actuator","tag-first-step","tag-general-actuator","tag-modulating-actuator","tag-fast-move-actuator","tag-very-small-actuator-tag"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/da_dk\/wp-json\/wp\/v2\/posts\/6075","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/da_dk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/da_dk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/da_dk\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/da_dk\/wp-json\/wp\/v2\/comments?post=6075"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/da_dk\/wp-json\/wp\/v2\/posts\/6075\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/da_dk\/wp-json\/wp\/v2\/media?parent=6075"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/da_dk\/wp-json\/wp\/v2\/categories?post=6075"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/da_dk\/wp-json\/wp\/v2\/tags?post=6075"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}