{"id":9985,"date":"2025-02-10T03:28:44","date_gmt":"2025-02-10T03:28:44","guid":{"rendered":"https:\/\/dclcontrols.com\/?p=9985"},"modified":"2025-03-28T10:36:19","modified_gmt":"2025-03-28T10:36:19","slug":"fsr-um","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/cs_cz\/podpora\/pohon-um\/fsr-um","title":{"rendered":"U\u017eivatelsk\u00e1 p\u0159\u00edru\u010dka k ak\u010dn\u00edmu \u010dlenu DCL s FSR"},"content":{"rendered":"<p><strong>Pohon DCL s FSR<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"size-medium alignleft\" src=\"https:\/\/dclcontrols.com\/dam\/actuator\/fsr\/images\/dcl-actuator-with-fsr.webp\" width=\"6912\" height=\"5028\" \/><\/p>\n<h5>Ovl\u00e1dac\u00ed panel<\/h5>\n<p><img decoding=\"async\" class=\"size-medium alignleft\" src=\"https:\/\/dclcontrols.com\/dam\/actuator\/fsr\/images\/dcl-actuator-fsr-panel.webp\" width=\"1920\" height=\"1964\" \/><\/p>\n<ul>\n<li><strong>Spojen\u00ed<\/strong>\n<p><strong>P1<\/strong>Nap\u00e1jen\u00ed DC24V +<\/p>\n<p><strong>P3<\/strong>Nap\u00e1jen\u00ed DC24V \u2013<\/p>\n<p><strong>P5<\/strong>Vstup 4\u201320 mA \u2013<\/p>\n<p><strong>P7<\/strong>Vstup 4\u201320 mA +<\/p>\n<p><strong>P9<\/strong>V\u00fdstup 4\u201320 mA \u2013<\/p>\n<p><strong>P11<\/strong>V\u00fdstup 4\u201320 mA +<\/p>\n<p><strong>P2<\/strong>Vstup ZAP\/VYP COM<\/p>\n<p><strong>P4<\/strong>Vstup ZAP\/VYP otev\u0159en\u00fd<\/p>\n<p><strong>P6<\/strong>Zav\u0159en\u00ed vstupu ZAP\/VYP<\/p>\n<p><strong>P8<\/strong>V\u00fdstup ZAP\/VYP COM<\/p>\n<p><strong>P10<\/strong>\uff1aZAP\/VYP V\u00fdstup rozpojen\u00fd<\/p>\n<p><strong>P12<\/strong>\uff1aZAP\/VYP Zav\u0159en\u00ed v\u00fdstupu<\/li>\n<li><strong>Tla\u010d\u00edtko<\/strong>\n<p><strong>Knokaut<\/strong>: Pou\u017e\u00edv\u00e1 se v re\u017eimu nastaven\u00ed. Stisknut\u00edm tohoto tla\u010d\u00edtka otev\u0159ete pohon.<br \/>\nzat\u00edmco jej uvoln\u00edte pro zastaven\u00ed. Sou\u010dasn\u011b stiskn\u011bte tla\u010d\u00edtka \u201eNastavit\u201c a \u201eOtev\u0159\u00edt\u201c pro<br \/>\nnastavte pln\u011b otev\u0159enou polohu.<\/p>\n<p><strong>Kansas City:<\/strong> Pou\u017e\u00edv\u00e1 se v re\u017eimu nastaven\u00ed. Stisknut\u00edm tohoto tla\u010d\u00edtka vypnete pohon.<br \/>\nzat\u00edmco jej uvoln\u00edte pro zastaven\u00ed. Sou\u010dasn\u00fdm stisknut\u00edm tla\u010d\u00edtek \u201eNastavit\u201c a \u201eZav\u0159\u00edt\u201c<br \/>\nnastavte polohu \u00fapln\u00e9ho zav\u0159en\u00ed.<\/p>\n<p><strong>KS:<\/strong> Pou\u017e\u00edv\u00e1 se v re\u017eimu nastaven\u00ed. Toto tla\u010d\u00edtko pou\u017eijte v kombinaci s<br \/>\nostatn\u00edm nakonfigurovat parametry.<\/li>\n<li><strong>P\u0159ep\u00edna\u010d<\/strong>\n<p><strong>Ji\u017en\u00ed Afrika<\/strong>Nastaven\u00ed provozn\u00edho re\u017eimu (v\u00fdchoz\u00ed nastaven\u00ed 1):<\/li>\n<\/ul>\n<blockquote><p><strong>1<\/strong>\u2013Norm\u00e1ln\u00ed modulace <strong>2<\/strong>\u2013Re\u017eim nastaven\u00ed <strong>3<\/strong>\u2013Reverzn\u00ed modulace<\/p><\/blockquote>\n<p><strong>SB<\/strong>Nastaven\u00ed bezpe\u010dnostn\u00ed polohy (v\u00fdchoz\u00ed nastaven\u00ed 1):<\/p>\n<blockquote><p><strong>1<\/strong>\u2013Je\u010fte k pln\u00e9mu otev\u0159en\u00ed <strong>2<\/strong>\u2013Udr\u017eujte pozici <strong>3<\/strong>\u2013Je\u010fte naplno<br \/>\nZav\u0159eno<\/p><\/blockquote>\n<ul>\n<li><strong>Indikace<\/strong>\n<p><strong>L1<\/strong>Zelen\u00e1, indik\u00e1tor nap\u00e1jen\u00ed;<\/p>\n<p><strong>L2<\/strong>\u010cerven\u00e1, chyba vstupn\u00edho sign\u00e1lu, rozsv\u00edt\u00ed se, kdy\u017e je vstupn\u00ed sign\u00e1l p\u0159ekro\u010den<br \/>\nrozsah;<\/p>\n<p><strong>L3<\/strong>\u010cerven\u00e1, chyba potenciometru, sv\u00edt\u00ed, kdy\u017e je potenciometr<br \/>\nabnorm\u00e1ln\u00ed nebo je p\u0159ipojovac\u00ed vodi\u010d p\u0159eru\u0161en\u00fd;<\/p>\n<p><strong>L4<\/strong>\u010cerven\u00e1, chyba zaseknut\u00ed, sv\u00edt\u00ed, kdy\u017e nelze pohon ovl\u00e1dat<br \/>\notev\u0159\u00edt nebo zav\u0159\u00edt.<\/li>\n<\/ul>\n<p><strong>Nastaven\u00ed<\/strong><\/p>\n<blockquote><p>P\u0159epn\u011bte SA na 2 pro vstup do re\u017eimu nastaven\u00ed. Pot\u00e9 m\u016f\u017eete nastavit<br \/>\nrozsah ot\u00e1\u010den\u00ed provozu, nastaven\u00ed bezpe\u010dnostn\u00ed polohy, kalibrace vstupu<br \/>\na v\u00fdstupn\u00ed sign\u00e1l atd.<\/p><\/blockquote>\n<ul>\n<li><strong>Provozn\u00ed rozsah<\/strong>\n<p><strong>Konfigurace pln\u011b zav\u0159en\u00e9 polohy<\/strong>\uff1a<\/li>\n<\/ul>\n<ol>\n<li>Stiskn\u011bte tla\u010d\u00edtko Otev\u0159\u00edt\/Zav\u0159\u00edt pro \u00fapln\u00e9 uzav\u0159en\u00ed ventilu.<br \/>\npozice.<\/li>\n<li>Dr\u017ete tla\u010d\u00edtko Set a pot\u00e9 tla\u010d\u00edtko Shut, dokud se nezapne L2.<br \/>\nasi o 3-4 sekundy pozd\u011bji, co\u017e znamen\u00e1 pln\u011b zav\u0159enou polohu<br \/>\nkonfigurace je hotov\u00e1.<\/li>\n<li>Nyn\u00ed m\u016f\u017eete tato 2 tla\u010d\u00edtka uvolnit.\n<p><strong>Konfigurace pln\u011b otev\u0159en\u00e9 polohy<\/strong>\uff1a<\/li>\n<\/ol>\n<p><!-- --><\/p>\n<ol>\n<li>Stiskn\u011bte tla\u010d\u00edtko Otev\u0159\u00edt\/Zav\u0159\u00edt pro \u00fapln\u00e9 otev\u0159en\u00ed ventilu.<br \/>\npozice.<\/li>\n<li>Dr\u017ete tla\u010d\u00edtko Set a pot\u00e9 tla\u010d\u00edtko Open, dokud se nezapne L2.<br \/>\nasi o 3-4 sekundy pozd\u011bji, co\u017e znamen\u00e1 pln\u011b otev\u0159enou polohu<br \/>\nkonfigurace je hotov\u00e1.<\/li>\n<li>Nyn\u00ed m\u016f\u017eete tato 2 tla\u010d\u00edtka uvolnit.\n<p><em>[Pozn\u00e1mka: Pokud byla pln\u011b otev\u0159en\u00e1 a zav\u0159en\u00e1 poloha nakonfigurov\u00e1na pomoc\u00ed<br \/>\nna stejn\u00e9 pozici bude konfigurace \u00fasp\u011b\u0161n\u011b provedena. Ale<br \/>\nPohon se v modula\u010dn\u00edm re\u017eimu neot\u00e1\u010d\u00ed.]{.underline}<\/em><\/li>\n<\/ol>\n<ul>\n<li><strong>Nastaven\u00ed bezpe\u010dnostn\u00ed polohy<\/strong><\/li>\n<\/ul>\n<p>Nastavte bezpe\u010dnostn\u00ed polohu pomoc\u00ed SB dle pot\u0159eby p\u0159i p\u0159eru\u0161en\u00ed nap\u00e1jen\u00ed<br \/>\nnefunk\u010dn\u00ed nebo byl vstupn\u00ed sign\u00e1l chybn\u00fd.<\/p>\n<ul>\n<li>Oto\u010dte SB do polohy 1, aby pohon pln\u011b otev\u0159el ventil.<br \/>\npozice.<\/li>\n<li>Oto\u010dte SB do polohy 2, aby pohon udr\u017eel aktu\u00e1ln\u00ed polohu ventilu.<\/li>\n<li>Oto\u010dte SB do polohy 3, aby pohon poh\u00e1n\u011bl ventil k \u00fapln\u00e9mu uzav\u0159en\u00ed.<br \/>\npozice.<\/p>\n<p>Tato \u010d\u00e1st konfigurace je obvykle zbyte\u010dn\u00e1, p\u0159ekonfigurujte ji<br \/>\npokud na tom opravdu z\u00e1le\u017e\u00ed.<\/li>\n<\/ul>\n<p><!-- --><\/p>\n<ul>\n<li><strong>Kalibrace v\u00fdstupu 4\u201320 mA<\/strong><\/li>\n<\/ul>\n<ol>\n<li>Oto\u010dte SA na 2<\/li>\n<li>Pro sledov\u00e1n\u00ed proudu p\u0159ipojte k sign\u00e1ln\u00edmu v\u00fdstupu amp\u00e9rmetr.<\/li>\n<li>Dr\u017ete tla\u010d\u00edtko nastaven\u00ed a pot\u00e9 sou\u010dasn\u011b otev\u0159ete a zav\u0159ete, dokud se nesv\u00edt\u00ed L2.<br \/>\nzapnuto, co\u017e znamen\u00e1, \u017ee jste vstoupili do kalibra\u010dn\u00edho re\u017eimu 4mA. Nyn\u00ed m\u016f\u017eete<br \/>\nmohl uvolnit tato 3 tla\u010d\u00edtka.<\/li>\n<li>Stiskn\u011bte tla\u010d\u00edtko Open (zv\u00fd\u0161it) nebo Shut (sn\u00ed\u017eit) pro nastaven\u00ed 4mA.<\/li>\n<li>Dr\u017ete tla\u010d\u00edtko nastaven\u00ed, dokud se L2 nevypne a znovu nezapne, pot\u00e9<br \/>\nUvoln\u011bte tla\u010d\u00edtko pro vstup do kalibrace 20mA.<\/li>\n<li>Stiskn\u011bte tla\u010d\u00edtko Open (zv\u00fd\u0161it) nebo Shut (sn\u00ed\u017eit) pro nastaven\u00ed 20 mA.<\/li>\n<li>Dr\u017ete tla\u010d\u00edtko nastaven\u00ed, dokud se L2 nevypne a znovu nezapne, pot\u00e9<br \/>\nUvoln\u011bte tla\u010d\u00edtko pro dokon\u010den\u00ed procesu kalibrace.<\/li>\n<\/ol>\n<ul>\n<li><strong>Kalibrace vstupu 4\u201320 mA<\/strong><\/li>\n<\/ul>\n<ol>\n<li>Oto\u010dte SA na 2<\/li>\n<li>P\u0159ipojte zdroj proudu 4\u201320 mA k sign\u00e1lov\u00e9mu vstupu pro generov\u00e1n\u00ed<br \/>\nodkaz.<\/li>\n<li>Dr\u017ete tla\u010d\u00edtko Set, dokud neza\u010dne blikat L2, pot\u00e9 tla\u010d\u00edtko Set uvoln\u011bte. Dr\u017ete tla\u010d\u00edtko Open (otev\u0159eno).<br \/>\na sou\u010dasn\u011b vypn\u011bte, dokud L3 neza\u010dne blikat, co\u017e signalizuje<br \/>\nPo vstupu do kalibra\u010dn\u00edho re\u017eimu nyn\u00ed uvoln\u011bte tato 2 tla\u010d\u00edtka.<\/li>\n<li>Generujte 4mA referenci na vstup, dr\u017ete nastavenou hodnotu a pot\u00e9 sepn\u011bte, dokud L4<br \/>\nse rozsv\u00edt\u00ed, co\u017e znamen\u00e1, \u017ee proudov\u00fd vstup byl kalibrov\u00e1n jako<br \/>\nReferen\u010dn\u00ed proud 4 mA. Nyn\u00ed m\u016f\u017eete uvolnit ob\u011b tla\u010d\u00edtka.<\/li>\n<li>Generujte 20mA referenci na vstup, dr\u017ete stisknut\u00e9 a pot\u00e9 zav\u0159en\u00e9, dokud se nep\u0159ipoj\u00ed L4.<br \/>\nse rozsv\u00edt\u00ed, co\u017e zna\u010d\u00ed, \u017ee proudov\u00fd vstup byl kalibrov\u00e1n dle<br \/>\nReferen\u010dn\u00ed proud 20 mA. Nyn\u00ed m\u016f\u017eete uvolnit ob\u011b tla\u010d\u00edtka.<\/li>\n<li>Dr\u017ete stisknut\u00e9 tla\u010d\u00edtko, dokud L3 nep\u0159estane blikat, co\u017e signalizuje prob\u00edhaj\u00edc\u00ed kalibraci.<br \/>\ndokon\u010deno.<\/li>\n<\/ol>\n<p><strong>Za\u010dn\u011bte pou\u017e\u00edvat<\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignleft size-medium\" src=\"https:\/\/dclcontrols.com\/dam\/actuator\/fsr\/images\/dcl-actuator-fsr-plug.webp\" width=\"1920\" height=\"2083\" \/><\/p>\n<ul>\n<li><strong>Modulace s 4-20mA<\/strong><\/li>\n<\/ul>\n<p>Oto\u010den\u00edm SA do polohy 1 spus\u0165te modulaci.<\/p>\n<ul>\n<li>Pohon bude ovl\u00e1dat ventil do specifick\u00e9 polohy, jakmile<br \/>\nP\u0159i\u0159azen vstupn\u00ed sign\u00e1l 4-20mA.<\/li>\n<li>V\u00fdstupn\u00ed sign\u00e1l 4\u201320 mA bude zobrazovat skute\u010dnou polohu ventilu.<br \/>\n\u010das.<\/li>\n<li>\u201eV\u00fdstup ON\/OFF otev\u0159en\u00fd\u201c vyd\u00e1 sign\u00e1l (p\u0159ipojeno k COM), kdy\u017e<br \/>\nventil byl p\u0159esunut do pln\u011b otev\u0159en\u00e9 polohy.<\/li>\n<li>\u201eVypnut\u00ed v\u00fdstupu ZAP\/VYP\u201c vyd\u00e1 sign\u00e1l (p\u0159ipojen\u00ed k COM), kdy\u017e<br \/>\nVentil byl p\u0159esunut do pln\u011b uzav\u0159en\u00e9 polohy.<\/li>\n<li>Pohon p\u0159esune ventil do bezpe\u010dnostn\u00ed polohy, kdy\u017e je dod\u00e1no<br \/>\nDo\u0161lo k v\u00fdpadku nap\u00e1jen\u00ed nebo k chyb\u011b vstupn\u00edho sign\u00e1lu.<\/li>\n<li>Pohon se po p\u0159ipojen\u00ed nap\u00e1jen\u00ed vr\u00e1t\u00ed do modula\u010dn\u00edho re\u017eimu a<br \/>\nvstupn\u00ed sign\u00e1l byl obnoven.<\/p>\n<p><em>[Pozn\u00e1mka: Oto\u010den\u00edm SA do polohy 3 aktivujete obr\u00e1cen\u00fd chod.]<br \/>\nco\u017e znamen\u00e1, \u017ee vstupn\u00ed hodnota 4mA bude p\u0159evedena jako 20mA a 20mA bude<br \/>\np\u0159en\u00e1\u0161eno jako 4mA. Modulace je tedy stejn\u00e1 jako<br \/>\nobr\u00e1cen\u011b.]{.podtr\u017eeno}<\/em><\/p>\n<p><img decoding=\"async\" src=\"media\/image4.png\" alt=\"1714094198309\" \/>{width=\u201d6,720833333333333in\u201d<br \/>\nv\u00fd\u0161ka=\u201d1,0701388888888889 palce\u201d}<\/li>\n<\/ul>\n<p><!-- --><\/p>\n<ul>\n<li><strong>ZAP\/VYP s pasivn\u00edm digit\u00e1ln\u00edm vstupem<\/strong><\/li>\n<\/ul>\n<p>Oto\u010den\u00edm SA do polohy 1 spus\u0165te modulaci.<\/p>\n<ul>\n<li>Pohon uvede ventil do pln\u011b otev\u0159en\u00e9 polohy, kdy\u017e<br \/>\n\u201eV\u00fdstup ZAP\/VYP rozpojen\u00fd\u201c byl aktivn\u00ed (p\u0159ipojen\u00ed k COM).<\/li>\n<li>Pohon uvede ventil do zcela uzav\u0159en\u00e9 polohy, kdy\u017e<br \/>\n\u201eSpojen\u00ed v\u00fdstupu ZAP\/VYP\u201c bylo aktivn\u00ed (p\u0159ipojen\u00ed k COM).<\/li>\n<li>\u201eV\u00fdstup ON\/OFF otev\u0159en\u00fd\u201c vyd\u00e1 sign\u00e1l (p\u0159ipojeno k COM), kdy\u017e<br \/>\nventil byl p\u0159esunut do pln\u011b otev\u0159en\u00e9 polohy.<\/li>\n<li>\u201eVypnut\u00ed v\u00fdstupu ZAP\/VYP\u201c vyd\u00e1 sign\u00e1l (p\u0159ipojen\u00ed k COM), kdy\u017e<br \/>\nVentil byl p\u0159esunut do pln\u011b uzav\u0159en\u00e9 polohy.<\/li>\n<li>V\u00fdstupn\u00ed sign\u00e1l 4\u201320 mA bude zobrazovat skute\u010dnou polohu ventilu.<br \/>\n\u010das.<\/li>\n<li>Pohon p\u0159esune ventil do bezpe\u010dnostn\u00ed polohy, kdy\u017e je dod\u00e1no<br \/>\nmoc byla p\u0159eru\u0161ena.<\/li>\n<li>Pohon se po zapnut\u00ed nap\u00e1jen\u00ed vr\u00e1t\u00ed do modula\u010dn\u00edho re\u017eimu.<br \/>\nzotavil se.<\/li>\n<\/ul>\n<p><!-- --><\/p>\n<ul>\n<li><strong>Modulace s Modbus-RTU\/RS485<\/strong><\/li>\n<\/ul>\n<p>Kontaktujte n\u00e1s pro v\u00edce informac\u00ed\u2026<\/p>\n<p><strong>Indikace poruchy<\/strong><\/p>\n<ul>\n<li><strong>L2: Chyba vstupn\u00edho sign\u00e1lu<\/strong>\n<p>Vstupn\u00ed sign\u00e1l je p\u0159eru\u0161en\u00fd nebo mimo rozsah (&lt;2,5 mA nebo &gt; 21,5 mA)<\/li>\n<li><strong>L3: Chyba m\u011b\u0159en\u00ed polohy<\/strong>\n<p>Potenciometr nebo p\u0159ipojovac\u00ed vodi\u010d je p\u0159eru\u0161en\u00fd<\/li>\n<li><strong>L4: Chyba zaseknut\u00ed<\/strong>\n<p>Ventil se zasekl a pohon nem\u016f\u017ee ventil posunout do polohy<br \/>\no\u010dek\u00e1van\u00e1 pozice.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Pohon DCL s ovl\u00e1dac\u00edm panelem FSR P\u0159ipojen\u00ed P1\uff1aNap\u00e1jen\u00ed DC24V + P3\uff1aNap\u00e1jen\u00ed DC24V \u2013 P5\uff1aVstup 4-20mA \u2013 P7\uff1aVstup 4-20mA + P9\uff1aV\u00fdstup 4-20mA \u2013 P11\uff1aV\u00fdstup 4-20mA + P2\uff1aVstup ZAP\/VYP COM P4\uff1aVstup ZAP\/VYP otev\u0159en\u00fd P6\uff1aVstup ZAP\/VYP zav\u0159en\u00fd P8\uff1aV\u00fdstup ZAP\/VYP COM P10\uff1aV\u00fdstup ZAP\/VYP otev\u0159en\u00fd P12\uff1aV\u00fdstup ZAP\/VYP zav\u0159en\u00fd Tla\u010d\u00edtko KO: Pou\u017e\u00edv\u00e1 se v re\u017eimu nastaven\u00ed. Stisknut\u00edm tohoto tla\u010d\u00edtka otev\u0159ete [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[9],"tags":[],"class_list":["post-9985","post","type-post","status-publish","format-standard","hentry","category-um-actuator"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/cs_cz\/wp-json\/wp\/v2\/posts\/9985","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/cs_cz\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/cs_cz\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/cs_cz\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/cs_cz\/wp-json\/wp\/v2\/comments?post=9985"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/cs_cz\/wp-json\/wp\/v2\/posts\/9985\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/cs_cz\/wp-json\/wp\/v2\/media?parent=9985"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/cs_cz\/wp-json\/wp\/v2\/categories?post=9985"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/cs_cz\/wp-json\/wp\/v2\/tags?post=9985"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}