{"id":6077,"date":"2023-08-10T15:42:35","date_gmt":"2023-08-10T07:42:35","guid":{"rendered":"https:\/\/www.dcl-controls.com\/?p=6077"},"modified":"2025-03-31T08:09:15","modified_gmt":"2025-03-31T08:09:15","slug":"how-actuator-with-bus-works","status":"publish","type":"post","link":"https:\/\/dclcontrols.com\/ar\/%d8%a7%d9%84%d8%af%d8%b9%d9%85\/%d8%aa%d8%a7-%d8%a3%d9%83%d9%88%d8%aa%d8%a7%d8%aa%d9%88%d8%b1\/how-actuator-with-bus-works","title":{"rendered":"\u0643\u064a\u0641\u064a\u0629 \u0639\u0645\u0644 \u0627\u0644\u0645\u0634\u063a\u0644\u0627\u062a \u0630\u0627\u062a \u0648\u0638\u0627\u0626\u0641 \u0627\u0644\u0646\u0627\u0642\u0644 - \u0645\u0648\u062f\u0628\u0648\u0633\u060c \u0643\u0627\u0646\u060c \u0625\u064a\u062b\u0631\u0646\u062a\u060c \u0628\u0631\u0648\u0641\u064a\u0628\u0648\u0633"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6077\" class=\"elementor elementor-6077\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-05aec29 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"05aec29\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4dc31e3\" data-id=\"4dc31e3\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-11f2047 elementor-widget elementor-widget-text-editor\" data-id=\"11f2047\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0When you install a DCL electric control valve with bus functionality on a pipeline, you can control a set of electric control valves through the bus (Modbus, CAN, Ethernet, Profibus) to achieve synchronized control of the valve cluster.<\/p><p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone\" src=\"\/wp-content\/uploads\/2023\/08\/actuator-with-bus-application.webp\" alt=\"Using Bus Control for DCL Actuators\" width=\"1000\" height=\"555\" \/><\/p><ul><li>The control system communicates with the actuator via a bus communication protocol, sending commands to control the valve position. The actuator drives the valve to the specified position based on the bus commands.<\/li><li>If a bus error occurs, the actuator will drive the valve to fully open, fully closed, or maintain the valve position according to the user\u2019s settings during the bus error.<\/li><li>If the power supply to the actuator stops during valve operation, the actuator will stop, and the electric valve will remain in its current position.<\/li><\/ul><p><strong>\u0645\u0644\u0627\u062d\u0638\u0629:<\/strong> The above circuit diagram shows the basic functionality of a switch-type actuator (electric valve). In practical applications, additional protective components such as fuses and current limiters should also be considered.<\/p><p><strong>Three States<\/strong><\/p><figure style=\"width: 422px\" class=\"wp-caption alignnone\"><img decoding=\"async\" src=\"\/dam\/downloads\/user-manual\/vale-closed.webp\" alt=\"Electric Valve Closed\" width=\"422\" height=\"388\" \/><figcaption class=\"wp-caption-text\">Electric Valve Closed<\/figcaption><\/figure><figure style=\"width: 487px\" class=\"wp-caption alignnone\"><img decoding=\"async\" src=\"\/dam\/tech\/images\/vale-opening.webp\" alt=\"Flow Regulation\" width=\"487\" height=\"378\" \/><figcaption class=\"wp-caption-text\">Flow Regulation<\/figcaption><\/figure><figure style=\"width: 466px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" src=\"\/dam\/downloads\/user-manual\/vale-open.webp\" alt=\"Electric Valve Fully Open\" width=\"466\" height=\"388\" \/><figcaption class=\"wp-caption-text\">Electric Valve Fully Open<\/figcaption><\/figure><p>\u00a0<\/p><p>\u00a0<\/p><p><strong>Learn more about<\/strong><\/p><p><a href=\"\/ar\/%d8%a7%d9%84%d8%af%d8%b9%d9%85\/%d8%a3%d9%85-%d8%a7%d9%84%d9%85%d8%b4%d8%ba%d9%90%d9%91%d9%84\/um-sf-zc-modbus\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" src=\"\/dam\/tech\/images\/modbus-rs485.webp\" width=\"269\" height=\"159\" \/><\/a><\/p><p><a href=\"\/ar\/%d8%a7%d9%84%d8%af%d8%b9%d9%85\/%d8%a3%d9%85-%d8%a7%d9%84%d9%85%d8%b4%d8%ba%d9%90%d9%91%d9%84\/um-sf-zc-modbus\/\"><span style=\"text-decoration: underline;\">Control of DCL Electric Actuators via Modbus\/RS485<\/span><\/a><\/p><p>\u00a0<\/p><p><a href=\"\/ar\/%d8%a7%d9%84%d8%af%d8%b9%d9%85\/%d8%a3%d9%85-%d8%a7%d9%84%d9%85%d8%b4%d8%ba%d9%90%d9%91%d9%84\/dc-fb3\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" src=\"\/dam\/tech\/images\/modbus-tcpip.webp\" width=\"249\" height=\"147\" \/><\/a><br \/><a href=\"\/ar\/%d8%a7%d9%84%d8%af%d8%b9%d9%85\/%d8%a3%d9%85-%d8%a7%d9%84%d9%85%d8%b4%d8%ba%d9%90%d9%91%d9%84\/dc-fb3\/\"><span style=\"text-decoration: underline;\">Control of DCL Electric Actuators via Modbus\/TCP-IP<\/span><\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>\u00a0\u0639\u0646\u062f \u062a\u0631\u0643\u064a\u0628 \u0635\u0645\u0627\u0645 \u062a\u062d\u0643\u0645 \u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0645\u0646 \u0646\u0648\u0639 DCL \u0645\u0632\u0648\u062f \u0628\u0648\u0638\u064a\u0641\u0629 \u0646\u0627\u0642\u0644 \u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a \u0639\u0644\u0649 \u062e\u0637 \u0623\u0646\u0627\u0628\u064a\u0628\u060c \u064a\u0645\u0643\u0646\u0643 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0645\u062c\u0645\u0648\u0639\u0629 \u0645\u0646 \u0635\u0645\u0627\u0645\u0627\u062a \u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0639\u0628\u0631 \u0646\u0627\u0642\u0644 \u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a (Modbus\u060c CAN\u060c Ethernet\u060c Profibus) \u0644\u062a\u062d\u0642\u064a\u0642 \u062a\u062d\u0643\u0645 \u0645\u062a\u0632\u0627\u0645\u0646 \u0641\u064a \u0645\u062c\u0645\u0648\u0639\u0629 \u0627\u0644\u0635\u0645\u0627\u0645\u0627\u062a. \u064a\u062a\u0648\u0627\u0635\u0644 \u0646\u0638\u0627\u0645 \u0627\u0644\u062a\u062d\u0643\u0645 \u0645\u0639 \u0627\u0644\u0645\u0634\u063a\u0644 \u0639\u0628\u0631 \u0628\u0631\u0648\u062a\u0648\u0643\u0648\u0644 \u0627\u062a\u0635\u0627\u0644 \u0646\u0627\u0642\u0644 \u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a\u060c \u0648\u064a\u0631\u0633\u0644 \u0623\u0648\u0627\u0645\u0631 \u0644\u0644\u062a\u062d\u0643\u0645 \u0641\u064a [\u2026]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":true,"footnotes":""},"categories":[8],"tags":[53,66,62,57,64,52,65],"class_list":["post-6077","post","type-post","status-publish","format-standard","hentry","category-ta-acutator","tag-actuator","tag-explosion-proof-actuator","tag-first-step","tag-general-actuator","tag-modulating-actuator","tag-fast-move-actuator","tag-very-small-actuator-tag"],"acf":[],"_links":{"self":[{"href":"https:\/\/dclcontrols.com\/ar\/wp-json\/wp\/v2\/posts\/6077","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dclcontrols.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dclcontrols.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dclcontrols.com\/ar\/wp-json\/wp\/v2\/comments?post=6077"}],"version-history":[{"count":0,"href":"https:\/\/dclcontrols.com\/ar\/wp-json\/wp\/v2\/posts\/6077\/revisions"}],"wp:attachment":[{"href":"https:\/\/dclcontrols.com\/ar\/wp-json\/wp\/v2\/media?parent=6077"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dclcontrols.com\/ar\/wp-json\/wp\/v2\/categories?post=6077"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dclcontrols.com\/ar\/wp-json\/wp\/v2\/tags?post=6077"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}